Loading...
HomeMy WebLinkAboutEnergy Coden 1 FORM R405-2020 FLORIDA ENERGY. EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation = Residential Performance Method Project Name: Lot 16 Phase 3 Waterstone 2265 ATGGL Builder Name:. ADAMS HOMES Street: 8336 Amalfi Circle Permit Office: City, State, Zip: Port Saint Lucie, FL , 34952 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO. INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1994'.2 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul,.Exterior R=4.1 1378.30 ft2 b. Frame - Wood, Exterior R=13.0 407.83 ft2 3. Number of units, if multiple family 1 c. Frame -. Wood, Adjacent R=13.0 208.00 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2357.0 sqft.) Insulation Area -a. Under Attic (Vented) R=30.0 2277.00 ft} 6. Conditioned floor area above grade-(ft2) 2277 b. Knee Wall (Vented) R=19.0 80.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(273.9 sqft.) : Description Area 12. Ducts R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 456.2 a. U-Factor: gbl, U=0.33 :154.00 ft2 SHGC: SHGC=0.23: . b. U-Factor: Dbl, U=0.33 66.00 ft.2 13. Cooling systems :kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 -35.56 ft2 SHGC: SHGCng Area Weighted Average Overhang Depth: 5.043 ft. D 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: - 0.292 a . Electric Heat Pump 34.6 HSPF:8.50 ' .8. Skylights :Area o. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric.. Cap: 40 gallons 9. Floor Types . (2277.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft2 b: Conservation features b. N/A R= ft2 None c. N/A -R= ft2 16. Credits Pstat Total Proposed Modified Loads: 63:00 Glass/Floor Area: 0.120 PASS Total Baseline Loads: 66.97 /�1�7 I hereby certify that the plans a ?IpA06tigns covered. Revie f the plans and this, calculation are in compli a and rgy specifications covered by this B0. Code. calculation indicates compliance with the'Florida Energy Code. PREPARED BY: .:. Before construction is completed r DATE: 04-19-9091 Winn KPnmany this building will be inspected for comoliance with Section 553.908 I herebycertify that this building, as designed, is in compliance fy 9, 9 Florida Statutes. with the Florida er Co OWNER/AGE BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handierunit manufacturer that -the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. = -;Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST RFPC)RT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 16 Phase 3 Waterstone 2 Bedrooms: 4 User Conditioned Area: 2277 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Lot Information 16-3 Waterstone 8336 Amalfi Circle St. Lucie Port Saint Lucie , FL , 34952 CLIMATE / V Design Location Design Temp TMY Sit 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2277 20493 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2277 20493 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0 2277 ft2 ---- 0.35 0 0.65 ROOF / V/ # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Barr Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or Shed Composition shingles 2546 ft2 570 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2277 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown 2277 ft2 0.11 Main 19 Double Batt 80 ft2 0.11 Wood Wood 4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 i FORM R405-2020 INPUT SIIMMARY CI-IFCKI IAT RFP(IPT n WALLS I Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 W Exterior Frame - Wood Main 13 10 2 8 0 81.3 ftz 0 0.23 0.6 0 2 W Exterior Concrete Block - Int Insul Main 4.1 38 7 10 0 385.8 ftz i 0 0 0.6 0 3 S Exterior Frame - Wood Main 13 4 6 10 0 45.0 ftz 0 0.23 0.6 0 4 S Exterior Concrete Block - Int Insul Main 4.1 28 6 10 0 285.0 ftz i 0 i 0 0.6 0 5 E Exterior Frame - Wood Main 13 6 9 8 0 54.0 ftz 0 i 0.23 0.6 0 6 E Exterior Concrete Block - Int Insul Main 4.1 50 3 8 0 402.0 ftz 0 0 0.6 0 7 NE Exterior Frame - Wood Main 13 3 10 10 0 38.3 ftz 0 0.23 0.6 0 8 NE Exterior Concrete Block - Int Insul Main 4.1 0 5 10 0 4.2 ftz 0 0 0.6 0 9 N Exterior Frame - Wood Main 13 18 11 10 0 189.2 ftz 0 I 0.23 0.6 0 10 N Exterior Concrete Block - Int Insul Main 4.1 37 8 8 0 301.3 ftz i 0 0 0.6 0 11 - Garage Framel- Wood Main 13 26 0 8 0 208.0 ftz 0 0.23 0.01 0 DOORS I # Ornt Door Type Space Storms U-Value Width j Height Area Ft In i Ft In 1 S Insulated Main None .25 3 6 8 20 ftz 2 Wood Main None .25 2 8 6 8 17.8 ftz 3 E Insulated Main None .25 2 I 8! 6 8 17.8 ftz WINDOWS i Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ftz 23 ft 0 in 0 ft 9 in Drapes/blinds None 2 W 2 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ftz 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 S 3 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ftz 7 ft 8 in 0 ft 6 in None None 4 S 4 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ftZ 7 ft 8 in 2 ft 10 in None None 5 S 4 Vinyl Low-E Double Yes 0.33 0.21 N 30.0 ft' 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 6 S 4 Vinyl Low-E Double Yes 0.33 0.21 N 36.0 ftz 1 ft 0 in 2 ft 10 in I Drapes/blinds Exterior 5 7 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.0 ft' 1 ft 0 in 0 ft 10 in i Drapes/blinds Exterior 5 8 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 15.0 ft' 1 ft 0 in 0 ft 10 in i Drapes/blinds Exterior 5 9 NE 7 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ftz 11 ft 0 in 0 ft 4 in Drapes/blinds Exterior 5 10 N 9 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ftz 9 ft 4 in 0 ft 9 in Drapes/blinds None 11 N 9 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ftz 6 ft 8 in 0 ft 4 in Drapes/blinds Exterior 5 12 N 9 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft' 9 ft 4 in 0 ft 4 in Drapes/blinds Exterior 5 13 N 10 Vinyl Low-E Double Yes 0.33 0.23 N 45.0 ftz 1 ft 0 in 0 ft 10 in i Drapes/blinds Exterior 5 4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 I FORM R405-2020 INPUT SUMMARY CHFCKI IST RFPnRT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 617 ftz 617 ftz 64 ft 9 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2390.9 131.17 246.26 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # ---- Supply ---- Location R-Value Area ---- Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 456.2 ft Main 114.05 Default Leakage Main (Default) (Default) 1 1 4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 r. FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Heating f X� Jan ]Feb �X] Feb Mar Mar A r f Apr f Ma May Jun Jun rl Jul Jul rl Au Au rl Se SeP rl Oct Oct Nov Nov Dec Dec Ventin [ l Jan ] Feb X Mar [X] A r [ Ma Jun Jul Aug Se [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz 0 ft 0.3 Main 4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. 8336 Amalfi Circle, Port Saint Lucie, FL, 34952 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2: Single family or multiple family. Detached a. Concrete Block : Int Insul, Exterior R=4.1 1378.30 ftz b. Frame - Wood, Exterior R=13.0 407.83 ftz 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=13.0 208.00 ftz 4. Number of Bedrooms 4 d. N/A R= ftz 5.. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 MT00. ftz 6. Conditioned floor area (ftz) 2277 b. Knee Wall (Vented) R=19.0 80.00 ftz . 7. Windows- Description Area c. N/A R= ft z . a. U-Factor: bbl, U=0.33 154.00 ftz 12. Ducts, location & insulation level R ftz : a. Sup: Attic, Ret: Main, AH: Main 6 456.2 SHGC: SHGC=0.23. b. U-Factor: Dbl, 0=0.33 66.60 ft? SHGC: . SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 35.56 ftz a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.70 d. U-Factor: other (see,details) 18.33 ftz SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average Overhang Depth: 5.043 ft. Area Weighted Average SHGC: 0.292 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ffz aa. Electric Cap: 40 gallonsEF:0.94 SHGC(AVG): N/A b. Conservation features: 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ftz Credits (Performance method) Pstat b. N/A R= ftz c. N/A R= ftz I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be.completed based on installed Code compliant features. Builder Signature ��� Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy. Conservation, if not DEFAULT. 4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1