HomeMy WebLinkAboutEnergy Coden
1
FORM R405-2020
FLORIDA ENERGY. EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation = Residential Performance Method
Project Name: Lot 16 Phase 3 Waterstone 2265 ATGGL
Builder Name:. ADAMS HOMES
Street: 8336 Amalfi Circle
Permit Office:
City, State, Zip: Port Saint Lucie, FL , 34952
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO. INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type$1994'.2 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul,.Exterior
R=4.1 1378.30 ft2
b. Frame - Wood, Exterior
R=13.0 407.83 ft2
3. Number of units, if multiple family 1
c. Frame -. Wood, Adjacent
R=13.0 208.00 ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2357.0 sqft.)
Insulation Area
-a. Under Attic (Vented)
R=30.0 2277.00 ft}
6. Conditioned floor area above grade-(ft2) 2277
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(273.9 sqft.) : Description Area
12. Ducts
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
a. U-Factor: gbl, U=0.33 :154.00 ft2
SHGC: SHGC=0.23: .
b. U-Factor: Dbl, U=0.33 66.00 ft.2
13. Cooling systems
:kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 -35.56 ft2
SHGC: SHGCng
Area Weighted Average Overhang Depth: 5.043 ft.
D
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: - 0.292
a . Electric Heat Pump
34.6 HSPF:8.50 '
.8. Skylights :Area
o. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric..
Cap: 40 gallons
9. Floor Types . (2277.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft2
b: Conservation features
b. N/A R= ft2
None
c. N/A -R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 63:00
Glass/Floor Area: 0.120
PASS
Total Baseline Loads: 66.97
/�1�7
I hereby certify that the plans a ?IpA06tigns covered.
Revie f the plans and
this, calculation are in compli a and rgy
specifications covered by this
B0.
Code.
calculation indicates compliance
with the'Florida Energy Code.
PREPARED BY: .:.
Before construction is completed
r
DATE: 04-19-9091 Winn KPnmany
this building will be inspected for
comoliance with Section 553.908
I herebycertify that this building, as designed, is in compliance
fy 9, 9
Florida Statutes.
with the Florida er Co
OWNER/AGE
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handierunit manufacturer that -the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
= -;Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST RFPC)RT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 16 Phase 3 Waterstone 2 Bedrooms: 4
User Conditioned Area: 2277
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Lot Information
16-3
Waterstone
8336 Amalfi Circle
St. Lucie
Port Saint Lucie ,
FL , 34952
CLIMATE
/
V Design Location
Design Temp
TMY Sit 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2277 20493
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2277 20493 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0
2277 ft2 ----
0.35 0 0.65
ROOF
/
V/ #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2546 ft2 570 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2277 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown 2277 ft2 0.11
Main 19 Double Batt 80 ft2 0.11
Wood
Wood
4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
i
FORM R405-2020 INPUT SIIMMARY CI-IFCKI IAT RFP(IPT
n
WALLS
I
Adjacent
Space
Cavity
Width
Height
Sheathing Framing Solar Below
1 W
Exterior
Frame - Wood
Main
13
10
2
8 0
81.3 ftz
0
0.23 0.6
0
2 W
Exterior
Concrete Block - Int Insul
Main
4.1
38
7
10 0
385.8 ftz
i
0
0 0.6
0
3 S
Exterior
Frame - Wood
Main
13
4
6
10 0
45.0 ftz
0
0.23 0.6
0
4 S
Exterior
Concrete Block - Int Insul
Main
4.1
28
6
10 0
285.0 ftz
i
0 i
0 0.6
0
5 E
Exterior
Frame - Wood
Main
13
6
9
8 0
54.0 ftz
0 i
0.23 0.6
0
6 E
Exterior
Concrete Block - Int Insul
Main
4.1
50
3
8 0
402.0 ftz
0
0 0.6
0
7 NE
Exterior
Frame - Wood
Main
13
3
10
10 0
38.3 ftz
0
0.23 0.6
0
8 NE
Exterior
Concrete Block - Int Insul
Main
4.1
0
5
10 0
4.2 ftz
0
0 0.6
0
9 N
Exterior
Frame - Wood
Main
13
18
11
10 0
189.2 ftz
0 I
0.23 0.6
0
10 N
Exterior
Concrete Block - Int Insul
Main
4.1
37
8
8 0
301.3 ftz
i
0
0 0.6
0
11 -
Garage
Framel- Wood
Main
13
26
0
8 0
208.0 ftz
0
0.23 0.01
0
DOORS
I
#
Ornt
Door Type
Space
Storms
U-Value
Width j
Height
Area
Ft
In i
Ft In
1
S
Insulated
Main
None
.25
3
6 8
20 ftz
2
Wood
Main
None
.25
2
8
6 8
17.8 ftz
3
E
Insulated
Main
None
.25
2
I
8!
6 8
17.8 ftz
WINDOWS
i
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V # Ornt ID
Frame Panes NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 W
1
Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ftz
23 ft 0 in
0 ft 9 in
Drapes/blinds
None
2 W
2
Vinyl Low-E Double
Yes
0.33
0.23
N
30.0 ftz
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
3 S
3
Vinyl Low-E Double
Yes
0.33
0.31
N
5.0 ftz
7 ft 8 in
0 ft 6 in
None
None
4 S
4
Vinyl Low-E Double
Yes
0.33
0.31
N
13.3 ftZ
7 ft 8 in
2 ft 10 in
None
None
5 S
4
Vinyl Low-E Double
Yes
0.33
0.21
N
30.0 ft'
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
6 S
4
Vinyl Low-E Double
Yes
0.33
0.21
N
36.0 ftz
1 ft 0 in
2 ft 10 in I
Drapes/blinds
Exterior 5
7 E
6
Vinyl Low-E Double
Yes
0.33
0.23
N
9.0 ft'
1 ft 0 in
0 ft 10 in i
Drapes/blinds
Exterior 5
8 E
6
Vinyl Low-E Double
Yes
0.33
0.23
N
15.0 ft'
1 ft 0 in
0 ft 10 in i
Drapes/blinds
Exterior 5
9 NE 7
Vinyl Low-E Double
Yes
0.33
0.23
N
12.5 ftz
11 ft 0 in
0 ft 4 in
Drapes/blinds
Exterior 5
10 N
9
Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ftz
9 ft 4 in
0 ft 9 in
Drapes/blinds
None
11 N
9
Vinyl Low-E Double
Yes
0.33
0.23
N
12.5 ftz
6 ft 8 in
0 ft 4 in
Drapes/blinds
Exterior 5
12 N
9
Vinyl Low-E Double
Yes
0.33
0.23
N
30.0 ft'
9 ft 4 in
0 ft 4 in
Drapes/blinds
Exterior 5
13 N
10
Vinyl Low-E Double
Yes
0.33
0.23
N
45.0 ftz
1 ft 0 in
0 ft 10 in i
Drapes/blinds
Exterior 5
4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
I
FORM R405-2020 INPUT SUMMARY CHFCKI IST RFPnRT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
617 ftz
617 ftz
64 ft 9 ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.0004
2390.9 131.17 246.26 .1324 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.5 34.6 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 35 kBtu/hr cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
V #
---- Supply ----
Location R-Value Area
---- Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 456.2 ft
Main
114.05 Default Leakage Main (Default) (Default)
1 1
4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
r.
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan
Heating f X� Jan
]Feb
�X] Feb
Mar
Mar
A r
f Apr
f
Ma
May
Jun
Jun
rl
Jul
Jul
rl
Au
Au
rl
Se
SeP
rl
Oct
Oct
Nov
Nov
Dec
Dec
Ventin [ l Jan
] Feb
X Mar
[X] A r
[
Ma
Jun
Jul
Aug
Se
[X] Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
1
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE
LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE
INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
8336 Amalfi Circle, Port Saint Lucie, FL, 34952
1. New construction or existing New (From Plans)
10. Wall Type and Insulation
Insulation Area
2: Single family or multiple family. Detached
a. Concrete Block : Int Insul, Exterior
R=4.1 1378.30 ftz
b. Frame - Wood, Exterior
R=13.0 407.83 ftz
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=13.0 208.00 ftz
4. Number of Bedrooms 4
d. N/A
R= ftz
5.. Is this a worst case? No
11. Ceiling Type and insulation level
Insulation Area
a. Under Attic (Vented)
R=30.0 MT00. ftz
6. Conditioned floor area (ftz) 2277
b. Knee Wall (Vented)
R=19.0 80.00 ftz .
7. Windows- Description Area
c. N/A
R= ft z .
a. U-Factor: bbl, U=0.33 154.00 ftz
12. Ducts, location & insulation level
R ftz
: a. Sup: Attic, Ret: Main, AH: Main
6 456.2
SHGC: SHGC=0.23.
b. U-Factor: Dbl, 0=0.33 66.60 ft?
SHGC: . SHGC=0.21
13. Cooling systems
kBtu/hr Efficiency
c. U-Factor: Dbl, U=0.55 35.56 ftz
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.70
d. U-Factor: other (see,details) 18.33 ftz
SHGC: other (see details)
14. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
34.6 HSPF:8.50
Area Weighted Average Overhang Depth: 5.043 ft.
Area Weighted Average SHGC: 0.292
8. Skylights Description Area
15. Hot water systems
a. U-Factor(AVG): N/A ffz aa.
Electric
Cap: 40 gallonsEF:0.94
SHGC(AVG): N/A
b. Conservation features:
9. Floor Types Insulation Area
None
a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ftz
Credits (Performance method)
Pstat
b. N/A R= ftz
c. N/A R= ftz
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be.completed
based on installed Code compliant features.
Builder Signature ��� Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy. Conservation, if not DEFAULT.
4/19/2021 10:52 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1