Loading...
HomeMy WebLinkAboutRidge Vent (38) Florida Building Code Online 1/14/21,10:40 AM - i Business ♦ ProfessionalRegulationv BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search b a Product Approval r 4.USER:Public User is- "1.,1 P Product Approval Menu>Product or Application Search>Application List>Application Detail �OFFICEOFTHE FL# FL10758-R8 SECRETARY Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich, PE Validation Checklist- Hardcopy Received Certificate of Independence FL10758_R8_COI_OCR14003.4 2020 FBC Eval Vents final_.pdf Referenced Standard and Year(of Standard) Equivalence of Product Standards https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvldAviteOYO*2bC3zFtrydg9fPhgLACiVmFHfXgoD3ASJQ%3d%3d Page 1 of 3 Florida Building Code Online 1/14/21,10:40 AM Certified By Sections from the Code 1708.2 Product Approval Method Method 2 Option B Date Submitted 08/10/2020 Date Validated 12/16/2020 Date Pending FBC Approval 09/18/2020 Date Approved 12/17/2020 Summary of Products FL# Model, Number or Name Description 10758.1 VentSure 4-Foot Strip Heat and Copolymer plastic low profile attic ridge vents for installation Moisture Ridge Vents in shingle roof systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758_R8_II_OCR14003.4 2020 FBC Eval Vents final_.pdf Approved for use outside HVHZ: Yes Verified By: Zachary R. Priest 74021 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Refer to evaluation report FL10758_R8_AE_OCR14003.4 2020 FBC Eval Vents final__pdf Created by Independent Third Party: Yes 10758.2 VentSure Low Profile Slant Back Galvanized metal roof vent Roof Vent With Exterior Louver Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758_R8_II_OCR14003.4 2020 FBC Eval Vents final_.pdf Approved for use outside HVHZ:Yes Verified By: Zachary R. Priest 74021 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Refer to evaluation report. FL10758_R8_AE_OCR14003.4 2020 FBC Eval Vents final_.pdf Created by Independent Third Party: Yes 10758.3 VentSure Rigid Roll Ridge Vent Ridge Ventilation System Limits of Use Installation Instructions Approved for use in HVHZ: No FL10758_R8_II_OCR14003.4 2020 FBC Eval Vents final__pdf Approved for use outside HVHZ: Yes Verified By: Zachary R. Priest 74021 Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Refer to evaluation report. FL10758_R8_AE_OCR14003.4 2020 FBC Eval Vents final__pdf Created by Independent Third Party: Yes Back Next Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copght 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® ® ® eC heck https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvldAviteOYO*2bC3zFtrydg9fPhgLACiVmFHfXgoD3ASJQ%3d%3d Page 2 of 3 Florida Building Code Online 1/14/21,10:40 AM Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvldAviteOYO*2bC3zFtrydg9fPhgLACiVmFHfXgoD3ASJQ%3d%3d Page 3 of 3 CREEK Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION(2020) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued December 15, 2020 1 Owens Corning Parkway Toledo, OH 43657 (800)438-7465 www.owenscorning.com Quality Assurance: PRI Construction Materials Technologies(QUA9110) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Sections: 1708.2 Properties: Roof Ventilation REFERENCES Entity Report No. Standard Year Architectural Testing, Inc(TST1558) 01-38660.04 TAS 100(A) 1995 Architectural Testing, Inc(TST1558) 01-38660.05 TAS 100(A) 1995 Architectural Testing, Inc(TST1558) C1774.01-109-18 TAS 100(A) 1995 ASTM D 635 2014 ASTM D 1929 2016 ASTM D 2843 2016 PRI Construction Materials Technologies(TST5878) AVIG-005-02-01 ASTM D 635 2014 ASTM D 1929 2016 ASTM D 2843 2016 PRI Construction Materials Technologies(TST5878) AVIG-006-02-01 ASTM G 155 2013 PRI Construction Materials Technologies(TST5878) 0CF-111-02-01 ASTM D 635 2014 ASTM D 1929 2016 ASTM D 2843 2016 PRI Construction Materials Technologies(TST5878) OCF-112-02-01 ASTM G 155 2013 PRI Construction Materials Technologies(TST5878) OCF-116-02-01 TAS 100(A) 1995 PRI Construction Materials Technologies(TST5878) OCF-223-02-01 TAS 100(A) 1995 PRI Construction Materials Technologies(TST5878) OHI-007-02-01 TAS 100(A) 1995 OCR14003.4 FL10758-R8 Page 1 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK OWoof CORNING VentSure® Roof Ventilation TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND APPLICATION VentSure"4-Foot Strip 1-1/4" x 14-7/8" x 48" low-profile attic ridge vent consisting of a two-layer nylon- Heat and Moisture Ridge polyester composite. Available with or without a polyester fabric moisture barrier for Vents: installation in shingle roof systems. ■ 48" 14-7/8" j• r r • r ) Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 to maximum 16/12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 6-inches from the rake edges. Apply a '/4-inch wide bead of ASTM D 4586 roofing cement along the entire length of the outside edges of the vent to seal the vent to the field shingles, taking care to not completely cover the weep slots in the vent. Center the vent over the opening and fasten to the deck using the 11 ga. 2'/z-inch galvanized ring shank nails (shall comply with FBC Section 1506.5) provided with the vent. Fasteners are to be installed on both sides of the vent 1, 12, 24, 36, and 47-inches from the start of each vent piece. Prepare the adjacent vent section by applying the roofing cement along the edges, snap together with fixed vent, and fasten to the deck in the same manner as the first section. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 11 ga. 2'/z-inch galvanized ring shank roofing nails (shall comply with FBC Section 1506.5) provided with the vent or as directed by the shingle manufacturer's installation instructions. Allowable Roof Coverings: Asphalt shingles OCR14003.4 FL10758-R8 Page 2 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK OWoof CORNING VentSure® Roof Ventilation TECHNICAL SERVICES, LLC VentSure"Low Profile 18"x 24"x 2-3/16"(32"x 23"flange base)static off-ridge vent composed of ASTM Slant Back Roof Vent A653 galvanized steel (available with painted finish). Material shall conform with with Exterior Louver: FBC Section 1507.4.3. 37' ------ I J — T r -�T „ iQP BOTT wa.� 7-xrr' byY �1 LACE f RiCHT Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 3:12 Installation Height: Maximum 33-ft Attachment Method: Cut an 11 x 11-inch hole through wood sheathing only approximately 18-inches from the ridge. Apply 1/4-inch thick by 3-inch wide bed of ASTM D 4586 roofing cement around inner and outer flange. Place vent directly over the hole, ensuring the vent sits flat on the roof. Fasten vent 4-inches o.c. and 1-inch from outside edge of flange with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring %minch penetration through wood deck (Minimum 18 nails per vent). Install baffle in '/4-inch bed of ASTM D 4586 roofing cement and secure with minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) spaced 8-inches o.c. (total of (3) nails) while ensuring %-inch penetration through wood deck. Seal all nails and vent flange with ASTM D 4586 roofing cement. Allowable Roof Coverings: Asphalt shingles OCR14003.4 FL10758-R8 Page 3 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK OWoof CORNING VentSure® Roof Ventilation TECHNICAL SERVICES, LLC VentSure"Rigid Roll 5/8"x 11-1/4"x 20' attic ridge vent composed of high density polypropylene with a Ridge Vent: spun-bond polypropylene fabric. zo' i7p � Deck Type: Roof deck shall be constructed of closely fitted sheathing for new or existing construction. Roof deck shall be designed and installed in accordance with FBC requirements. Roof slope: Minimum 2:12 to maximum 20:12 Installation Height: Maximum 60-ft Attachment Method: Cut a 2-inch opening (1-inch on each side of the ridge) centered in the deck at the ridge for ventilation. The slot shall terminate approximately 12-inches from the rake edges. Apply a continuous bead of polyurethane adhesive sealant along the entire length of the outside edges of the vent to seal the vent to the field shingles. Center the vent over the opening and fasten the vent 24-inches o.c. to the deck using minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5), ensuring%-inch penetration through wood deck. Fasten the ridge shingles over the vent to the deck on the marked "shingle nail line" with two (2) minimum 12 ga. ring shank roofing nails (shall comply with FBC Section 1506.5) or as directed by the shingle manufacturer's installation instructions, ensuring%-inch penetration through wood deck. Outside edges of the shingles shall be sealed with flashing cement. Allowable Roof Coverings: Asphalt shingles LIMITATIONS 1) This report is not for use in the HVHZ. 2) Fire Classification is outside the scope of this evaluation. 3) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 4) Owens Corning vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 6) Installation of the roof assembly is outside the scope of this evaluation. 7) Owens Corning vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. 8) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. OCR14003.4 FL10758-R8 Page 4 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK OWoof CORNING VentSure® Roof Ventilation TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020)as evidenced in the referenced documents submitted by the named manufacturer. ttttJ111111111 2020. 12. 15 ` %G�PFtY R.•pRi�,�i •.•�,\C•E•N S�• 13:59:34 o 74021 N Digitally signetl by ZacM1ary R.Pneat -05 STATE O F �/ - '00' O••. z/ ������`•'c< O R k O P�N�� Zachary R. Priest, P.E. Florida No. �NA� Organization No.lon ANE9641021 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest,P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. END OF REPORT OCR14003.4 FL10758-R8 Page 5 of 5 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.