HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 31 Phase 3 Waterstone 2117CRGL
Builder Name: ADAMS HOMES
Street: 8331 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce, FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type41664.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1436.00 ftZ
b. Frame - Wood, Adjacent
R=13.0 228.00 ftZ
3. Number of units, if multiple family 1
c. N/A
R= ftZ
4. Number of Bedrooms 4
d. N/A
R= ftZ
5. Is this a worst case? No
11. Ceiling Types (2195.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2115.00 ftZ
6. Conditioned floor area above grade (ftZ) 2115
b. Knee Wall (Vented)
R=19.0 80.00 ftz
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ftZ
7. Windows(244.1 sqft.) Description Area
12. Ducts
R ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 423
a. U-Factor: Dbl, U=0.33 159.41 ftZ
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 48.56 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEERA6.00
c. U-Factor: Dbl, U=0.33 18.33 ftZ
SHGC: SHGC=0.31
Area Weighted Average Overhang Depth: 5.215 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.266
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftZ
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2115.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2115.00 ftZ
b. Conservation features
b. N/A R= ftZ
None
c. N/A R= ftZ
16. Credits
Pstat
Glass/Floor Area: 0.115 Total Proposed Modified Loads: 61.43
PASS
Total Baseline Loads: 61.96
I hereby certify that the plans ications coveree
this '
ReviN of the plans and
'
calculation are in comp' n o hergy
specifications covered by this
p
"
Code.
calculation indicates compliance
with the Florida Energy Code.
Irfi°jN
PREPARED BY:
Before construction is completed
DATE: n4-16-9rn1 Winn KPomany
this building will be inspected for
compliance with Section 553.908
* '
I hereby certify that this building, as designed, is in compliance
Florida Statutes:
with the Florida E
Cpl7.{p�'L
OWNER/AGENT
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
4/16/2021 11:18 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPI IT RI IMMARV rWF=rW1 ICT OMDr%DT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 31 Phase 3 Waterstone 2 Bedrooms: 4
User Conditioned Area: 2115
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
31 Phase 3
Waterstone
8331 Amalfi Circle
St. Lucie
Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2115 17343
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2115 17343 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 179.5 ft 0
2115 ft2 ----
0.34 0 0.66
ROOF
/
V/ #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2365 ft2 528 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2115 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2115 ft2 0.11
80 ft2 0.11
Wood
Wood
4/16/2021 11:18 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHFCKI IST RFPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar Below
Space
1 E
Exterior
Concrete Block - Int Insul
Main
4.1 41
0
8 0
328.0 ftz
0
0
0.6
0
2 N
Exterior
Concrete Block - Int Insul
Main
4.1 35
0
8 0
280.0 ftz
0
0
0.6
0
3 W
Exterior
Concrete Block - Int Insul
Main
4.1 48
6
8 0
388.0 ftz
0
0
0.6
0
4 S
Exterior
Concrete Block - Int Insul
Main
4.1 55
0
8 0
440.0 ftz
0
0
0.6
0
5 -
Garage
Frame - Wood
Main
13 28
6
8 0
228.0 ftz
0
0.23
0.01
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
N
Insulated
Main
None
.25
3
6 8
20 ftz
2
Wood
Main
None
.25
2
8
6 8
17.8 ftz
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
E
1
Vinyl
Low-E Double
Yes
0.33 0.23
N
6.9 ftz
1 ft 4 in
Oft 11 in
None
Exterior 5
2
N
2
Vinyl
Low-E Double
Yes
0.33 0.31
N
5.0 ftz
8 ft 0 in
0 ft 0 in
None
None
3
N
2
Vinyl
Low-E Double
Yes
0.33 0.21
N
32.4 ftz
1 ft 4 in
Oft 11 in
None
None
4
N
2
Vinyl
Low-E Double
Yes
0.33 0.21
N
16.2 ftz
1 ft 4 in
Oft 11 in
None
Exterior 5
5
N
2
Vinyl
Low-E Double
Yes
0.33 0.31
N
13.3 ftz
8 ft 0 in
3 ft 0 in
None
None
6
W
3
Vinyl
Low-E Double
Yes
0.33 0.23
N
6.9 ftz
1 ft 4 in
Oft 11 in
None
None
7
W
3
Vinyl
Low-E Double
Yes
0.33 0.23
N
16.2 ftz
1 ft 4 in
1 ft 0 in
None
None
8
S
4
Metal
Low-E Double
Yes
0.55 0.7
N
17.8 ftz
11 ft 4 in
1 ft 3 in
None
None
9
S
4
Vinyl
Low-E Double
Yes
0.33 0.23
N
48.6 ftz
1 ft 4 in
Oft 11 in
None
None
10
S
4
Vinyl
Low-E Double
Yes
0.33 0.23
N
64.8 ftz
11 ft 4 in
Oft 11 in
None
Exterior 5
11
E
1
Vinyl
Low-E Double
Yes
0.33 0.23
N
16.2 ftz
1 ft 4 in
Oft 11 in
None
Exterior 5
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
432 ftz
432 ftz
64 ft
8 ft
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000364
2023.3 111.01
208.4
.1276
7
4/16/2021 11:18 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Sing[ HSPF:8.5
34.6 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Sing[ SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
V # Location R-Value Area
---- Return ---
Location Area Leakage Type
Air
Handler
CFM 25
TOT
CFM25
OUT
QN
RLF
HVAC #
Heat Cool
1 Attic 6 423 ft'
Main
105.75 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb Mar
HeatinlX Jan f X Feb Mar
Ventin [ Jan [ Feb XMar
Ceiling Fans:
Jul
f Apr f May JunJul
Apr Ma rj Jun rl
[X] A r [ Ma Jun Jul
Au
AuSep
rj Aug
Se
ri Se
[X]
Oct
Oct
Oct
Nov
Nov
X Nov
Dec
XDec
[ Dec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6 7
8
9
10
11
12
Cooling (WD) AM 78
PM 80
Cooling (WEH) AM 78
PM 78
Heating (WD) AM 66
PM 68
Heating (WEH) AM 66
PM 68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78
78 78 78
78 78 78
78 78 78
66 66 68
68 68 68
66 66 68
68 68 68
78
78
78
78
68
68
68
68
78
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
4/16/2021 11:18 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.31
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted. Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
8331 Amalfi Circle, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1436.00 ft2
b. Frame - Wood, Adjacent
R=13.0
228.00 ft2
1
c. N/A
R=
ft2
4
d. N/A
R=
ft2
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2115.00 ft2
2115
b. Knee Wall (Vented)
R=19.0
80.00 ft2
Area
c. N/A
R=
ft2
159.41 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 423
48.56 ft2
13. Cooling systems
kBtu/hr
Efficiency
18.33 ft2
a. Central Unit
35.0 SEER:16.00
17.78 ft2
14. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
34.6
HSPF:8.50
5.215 ft.
0.266
Area
15. Hot water systems
ft2
a. Electric
Cap: 40 gallons
EF: 0.94
b. Conservation features
Insulation
Area
None
R=0.0
2115.00 ft2
Credits (Performance method)
Pstat
R=
ft2
R=
ft2
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant f a
Builder Signature: l _. Date:
Address of New Home: City/FL Zip:
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
" ""Label required by Section R303.1.3 of the Florida. Building Code, Energy Conservation, if not DEFAULT.
9 4/16/2021 11:18 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1