HomeMy WebLinkAboutShed Design4' I x 4 BRIDGING 2 x 4 BENT (TYP.) 1 x 4 BRIDGING a SEE DETAIL BELOW WINDOW OPENING t (2) 2 x B BEAM (TYP.: 4' ALUMINUM SIDIN( 2 x 4 BOTTOM PLATI 314• PLYWOOD FLOOF. HURRICANE ANCHORS (11.) USE SIMPSON LSTA-18 W/ $14 - 1 6 d NAILS 2 x S SIOERAIL WALL ANCHOR DETAIL SCALE: N.T.S. (2)-2x S STUD ADDED WHEN :R GARAGE DOOR INSTALLED= _2- MAX. WIDTH T- FOR, m ENTRANCE DOORS WIDTH 3', Z a.. & 8' FOR GARAGE DOORS & g DOUBLE DOORS WoW P.T.P. 4 .4 CONNECT FLOOR 'Ir JOISTTO.RUNNER N, SIMPSON HS24� (2).2 x 4 SPRUCE HEADER- • (2)-rXS02 PINE EACH SIDE ,,`,?) 2 x 4 BENT NON LOAD BEARING WHEN GARAGE DOOR INSTALLED 20 CA. - J' x 5" GALV. --- 1 x 4 BRIDGING O BENT (rYP.) Yi NAILED PLATES (2) PER, CONNECTION FOR HEADER 20 GAUGE 7'xSOALV. PRESS ' -- PLATE1 S(2) PER CONNECTION , SIMPSON TP35 PLATE W/ USE Bd COMMON 6 TYPICAL SLOPE AT KNEE �12JOINTOF ) (8) lTd x 1-1/2' NAILS TM2U INTO HEADER W/ (5) �- (2) 2x4 W/ 1/2" PLYWOOD SENT 10d x 3' NAIL 0 EACH SPACER OR 4x4 y2 PIN 1 x 4 BRIDGING 0 BENT (TYP) END SIMPSON. HS-24 W/ 5&5 16d NAILS 0 2x4 FRAME 2x4SENTFRAMES .. f- CONNECTED W110d COMMON ®1'd D.C. TYPE I SECTION THRU HEADER ' SCALE: 1 1 rI = V-T 2. 4 BOTTOM PLATE SEE ATTACHMENT DETAILS 2 x 4-BENT 20 GA. 3" . 5" GALV. • NAILED PLATES (2) PER CONNECTION FOR HEADER FOR INFORMATION NOT SHOWN SEE END ELEVATION USE 8d COMMON ENDELEVATION WITH DOOR TWO SKID MODELS 4.4 #2 PINE. 2x4 NAILED SCALE: 114•=1•d SIMPSON' iP35 PLATE W/ TO BOTTOM W/ (2) p16d '(a) 10d x 1-1/2' NAILS COMMON NAILS 0 IS' O.C. - 2. 4 HEADER THRU INTO HEADER W/ (5) 10d x 3" NAIL 0 EACH SIMPSON HS-24 STRAP - - Is 4 BRIDGING END INTERMEDIATE FRAMES OR 6 2 x4 BENT (TYP.) HEADERS W/ 4&4 16d TYP. SLOPE AT KNEE JOINT OF NAILS 0 2.4 FRAME i�12 BENT I x 4 BRIDGING - TYPE 11 SECTION THRU HEADER i f- 2 x 4 STUD (TYP.) SCALE 1 117 = 1'd SCALE: N.T.S. �•_� llyx % _ < lI..YY m 3W PLYWOOD FLOOR OVER' ` occup=LI-ry / Y (TYP.) 2 x 6 P.T.P. �p10OW irli., SEE ATTACHMENT DETAILS W-wd velocity Fin Ratii.r of Etr<. W-1& � -0 40'' MAX LENGTH 171pMf STA 401 crz Xt 1(a xr �:/� S VARIES"(8'd TO 174n 2•d O.C. MAX. JOIST SPACING Allow• Floor or L'i X �P�O� Dllte rNOR INFORMATION NOT SHOWN SEE END ELEVATION WITH DOOR x ! t� END ELEVATION FOUR SKID MODELS M,.f. SCALE: 114• a 1'd don.comply-iillh d1t t M111fiWMillod Bid. i.d adopted Coda and ISOMETRIC OF SHED Mere to the foB citcrw CS 4. 4 RUNF�C*Vai of this DaLwsLen' C AFt 2YOt Ambmize or App��'MY IJTion From the rcgsii "'S Of ,pk,Lk oink w statc LAWS FLOOR FRAMING PLAN SCALE: 1 fat' = 1'd (TYP.) ' n n If n n it I n to 7 IL In 'h lr-- S'd (Nr (MAX) SIDE ELEVATION WITH DOORS & WINDOWS . SCALE: Or • Pat 2'-0' 2x6 P.T.P. PLATES FOR SHEDS OVER 16' IN LENGTH 3W PLYWOOD FLOORING 4 x 4 RUNNER 2 x 4 BOTTOM PLATE (TYP. ALL AROUND) 2 x S BENT (rYP.) (SEE SIDE WALL ELEVATION) WINDOW / DOOR HEADER 2 x 4 HEADER 2. 4 BEMT (TYP.) 1 x 4 BRIDGING 2x4SILL 2 a 4 BOTTOM PLATE SEE DETAILS FOR .CONNECTION OUTSIDE WIDTHS: W-6', 10'-6', 12'-6'. Nd cc 1129 r � z r, PU P � ®mil 1® Cot cc CL W PO r-1" Q U in zt SINGLE WIDE ARCH W/ OVERHANG SCALE: 114--V-V LLJ 9 LL cpVMU 3 prodUCts in 'Iancd with kt Approval W 0 LLA 3-- r x 7 PRESS PLATES BOTH Q. �3 W ;;R SIDES ALL JOINTS W = LL8 17 C" CO = M .i2'. W LL.t (21 >z *.%: 2.4 CONSTRUCTION 9�-¢M0 Qf ALUMINUM DOOR SKIN ON BACK & BACK DOOR CONSTRUCTION (OPTIONAL) ^ N II L II WIRING DIAGRAM (OPTIONAL ELECTRIC) SCALE: N.T.S. ALL WIRING SHALL BE MC CABLE 14 GA (2) WIRE WIG. ALL METAL BOXES 2' x 2' SQUARE WASHERS 3/8" x 8' FORGED 3/8" . 2' BOLT W/ (2) EYEBOLT aWappASEEH�EE��RS & NUT (A-24 S NAM A-24 STRAP (1,200g UPLIFT) SIMPSON HS-24 (1) 3/8" x 3' (1.200# UPLIFT RATING) EXPANSION BOLT OR WEDGE ANCHOR TA INTO SLAB ® SPACING ~ 4 (PER TABLE-1) SHED W1 SKID ATTACHED ACHORED TO CONCRETE SCALE: 1 1 rS = 1'd (1)'3/8" x 5" (4008 UPLIFT RATING) WEDGE ANCHOR INTO CONCRETE SET UP AND INSTALLATION OF -SINGLE WIDE SHED 0°002 I. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 P.V.C. TO ALLOW FOR 9/10/2003 2/14/2004 MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE. PROPERTY LINE, ETC.` 2. ONCE UNIT IS SQUARE AND THE HIGH SPOT OF THE GROUNDIS ESTABLISHED THE 10/19/2004 BUILDING IS'SLOCKED ON HIGH SPOT AND LEVELED: THE OTHER END ORTHE BUILDING IS 11/05/2004 BROUGHT UP TO' LEVELAND BLOCKED THEN THE CENTER OF THE BUILDING IS BROUGHT UP 12/28/2004 TO LEVEL, BLOCKED, AND THEN SHIMMED::: 03/09/2005 3. AFTER THE BUILDING IS LEVEL. MORE BLOCKS ARE ADDEDTO ACHIEVE THE CORRECT SPACING. d: ANCHOR PLACEMENT IS ESTABLISHED BY WIDTH OF, BUILDING. HOLES ARE GRILLED D I THROUGH THE 2 x 4 BOTTOM PLATE WITH 10 AUGER BRAND THE EYEBOLT 19 FASTENED INTO PLACE_ THE HOLE IS DUO FOR 37 EARTH ANCHOR AND BACK FILLED. THE EYEBOLT BOLT: AND AUGER ANCHORBEATTACHED ntl (f_ 2t CO CRH Erxr S. IF UNIT TO ATTACHED TO CONCRETE sUB, THE BUILDING IS BET ON SLAB SHIMMED Dig APPROVE \\V/ r` OP TO LEVEL A'3R- HOLE IS DRILLED WITH HAMMER DRILL INTO CONCRETE 1-12' OFF RIM i'1 t� ,�{{'i� E 31 J' JOIST. THE EYEBOLT IS FASTENED THROUGH BOTTOM PLATE AND AN 1: BRACKET OR SIMPSON STRAP IS PLACED OVER THE 3Ar WEDGE ANCHOR, A Ire x r BOLT IS THEN FASTENED THROUGH THE EYEBOLT AND V BRACKET: DOCUMENT 9. IF NO FLOOR UNIT BUILDING IS USED, ANCHOR WITH 31W x S• WEDGE ANCHOR CENTERED BETWEEN EVERY WALL STUD. GENERAL NOTE§ 3 SPECIFICATIONS FOR AUGER ANCHORS S 1. Budding anchor shall be "moods'ham.'typa.a30 eblph h.� eye aupel anolon mwWasturod byStyle Croat of Fro.manL OH. Mo durum .mwabh uplift 2,00011or quimlent. . 2. Anchoring system to groundpar beat building code (by d.rd r), Loeb ..he. per Table 4 through the bomm plate. 3: Ancrom shell ha placed through the bottom PI•V and floor system, Table.l, •Shed Ancorin4 to. Concrete;Slob. Table 2 Runner SpacingAF Shed Widt . #4] II1t Sid! ' oG eAnchor-Soodn Si 14'-W , 200 a / UP 4'd Ai7d . 24001 LF I I Od. - 200111ILF I a'd '0 B'd'- 180//LF TS' Shed Widl X1 X2 X3 _ 14'd 1'-10 lrI, r G-fir 12'd 7•6.117 Bill 19d - Bd g eat . (.� -.- ` TD61-e 3 Su ort_.Eociing_P..ad-Spacing for-Runner-Blocking-For-Smgle`or-'Double-Double" `-K L. \ Shed Description Pod End Pod Side Runne Pad Type Interior Pad Side Runne Pad Type ize l T e.' LW -- PL � End Pad Max S ocin / 74' SW 0 4.,3 3 to 3- 5 B- 1936 It or 111 1879 II or III 4 2 `D_to 3 - 8 0'-- -1435 ^ ", 1 1640 _ _. I 12 SW 6.00 - 4 U -10..3 - • 5--4- - _ _2558 It or III 2558$ o or III . \110. I SW - 5.00 4 m to 3- 6-0.2400 II or III 24001 II or -III-- ' Nobs. 1. Pad spacing is end to center of pad. 2. Pads other than end pads. spacing is center to venter. 1 use a.. s acina for interior -runner. T e Pad Dimensions. Max. Load Material I r x 8' x 1S ' .1,778 • coner.t. bock usl' e.m.m & and erbl II • - 4' x e• x ,e• 1 3.5000 -rate block ue' anent& •ard mht III 1 lrx14 1 3.950/ JASSphurtipad.. SLAB - l.ea wxnn an runner ._. - SLAB AT SPACING Bu.d on 2,000 PSF •Iowa6U ad Drouun. Sal promo xMl be wrifi.tl by 6eW Demromebrtest or aads lab report. Geek w.h (PER TABLE 1) an0lnurBsollpmsunhhsstran2,000PSF. NOTCH OR COUNTER SINK Nobs:._ BOLT THRU 2 x 4 1. Hallow or silid concrete blocks may be stacked an pads for high sets up to 48max. with out 1-1/2- MINr, reinforcing.. 2. Pads required _og.a ,•_12' & 14' wide sheds only. t 2 x 4 BOTTOM PLATE ® aD1e_4o Anchor"Spacing"Of_AV4er Type Anchors For Single-31fide3 0 NAILED TO 2 x 6 BASE 4 'a• 30 Eye A er Anchor cr 30 CD Coral Anchor O 0 N 11 �y N SHED WITH FLOOR REMOVED ANCHORED TO CONCRETE 4 cai W SCALE: 1-1/2" = 1'-0' iQ. 0 SIMPSON MS-24 TYPE I OR II CONCRETE PAD W/ BLOCKING AS REQUIRED 11i x r FORGED EYE BOLT :SHED W/ SKID A'17ACHED STRAP DETAIL SCALE: 1M' • t'd SINGLE HEL'IX.AUGER-ANCROR7 SEE TABLE 4 FOR SPACING SCALE: N.T.S. Shed Siz LW U I�Tt PL End Anchor Nax. Intenor Soacin _ ,1'd 7.oD 243 _ _�-,dta.3.4"✓ __-�-T ,•�-�a - tTd': S-:OD 20B' idle 3'd tad--s:otr- iT4 1db3•d ta-0• e'd 4.00 ' 139 1 d l0 3'd 7T4T FORGED EYE BOLT OR 1/2" Table 4b Anchor Spacing Of Auger Type Anchors For Double Wide Sheds Eye Au V ?J THREADED ROD W/ 30 er,AnUor •• ,�S•j 2" X 2" WASHER & NUT CAPACITY) Shed Siz LW Uplift PL 20d . 10.0V 401 End Anchor•• Max. Interior S ocin -.11, 1. 5'd' .� . (2.000 + UPLFT Load width of uplifton runner. " v W J Q SEE STRAP DETAIL Loostion of end .uger ar slab anchor: r Anchor spacing example: 30' sugar or 3Ar x 2414• expansion hobs. ,7+ 1 /2" x 2' BOLT W/ (2) WASHERS & NUT (2,000 + SHEAR Nobs: All +•1 CAPACITY) 1.A Anchor spacing is based on 3 second wind gust at 150 MPH per 'C'. �A 4/J GRADE ASCE 7-98. Category Importance. Factor 0.77. Enclose Building. N.LP.C. 0.18. y 2. All measurements listed above are center to center of anchon. 13 3. The minimum number of auger anchors is (4). (1) 0 each corner of pJ Z shed for sheds less in length than the maximum. 4. The minimum edge distance for expansion bolts is 8 diameters or 5" q for 3/8' expansion bolts. 5. Anchors shall be on side walls except when shed is placed next to �1 aw fIl i m w w $ fisting building, m which anchors can be placed on and walls as close to C ` W es os possible. 'p r x 7 GALV. WASHER FORGED EYE BOLT OR 1/2' THREADED ROD 1 rr COUPLING t fr x 1 Ifr BOLT W1(2) WASHERS (2.OW/ • SHEAR CAPACITY) 1?.4'FORGED EYE BOLT 30- HURRICANE ANCHOR ftb CORAL EYE AUGER ANCHOR SHED DESIGN LOAD RE DIRE E 6 S. .roa..� for the 2004 Bulldln Ca 0. S Bads filledPnrFn y Cis- ''ee�11 N qz • o.wise(Kz)(txtXKtl)(y t par ASCE 7-e0 (� •�i" Ks • 0.89 Espawn C; Kzt =1.0 Kd n0.93:I.0.77tV=150 MPH qz =3204 PSF W a qc x 0.e5 • 27.24 PSF I hereby cMINj that I hen roW.wM tlwr Dhm abrrp win al the building mahrhio and tt cempaaNa ua.d in tin memderxwng mtn. Ywd.. The m.bri.Y and mmporuma eitlar Mn Florida Produce Approval.. required by Florida Building Commhormr Ruh (Chapter W a R 9B•72) of w.ia rarulyzfd u4bp Ina Rational Method.nd Alowxbio 9tn.• D.elpn. AO mabrhY � � c . and wmponeitls txunDy with the 2001 & 2004 Florida Building Code tot a 150 MPH what v.bcxy, eaaio and pbwun o17/:T4 PSF, I = 0.77, Encased Building, Expowro'C•, and C N.I.P.C. = Qt&., Root LM Load • 20 PSF, Roof Dnd Lxrad • 3 PSF, Flacr'N. lased = : 6 PSF, Floor Dead Load = s PSF. W i � a YaY1 Mfid Fora Retaliating Sptana Roof Wall ° NIA Compmsnts w 31 ze a gaddrtq Opa1Q1 (EHaativa) Prwaoava (f'SIF) 1 ;1 Zone Wind Area + - Zone Wind Arec + - 10 to 29 10 31 34 1 m n n 4 20 30 32 so 14 2e so -3 31 Zone that Area + - Zone Wind Area - 70 19 � 10 3r a2 21163 20 77 SS 5 20 sD u n so 2e 3s j �.t Lawrence E. Bennett, P.E. #16644 a/ t