HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY. CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
Lot 117 Block 5 Waterstone 1635 BGL
Street:
5330 San Benedetto Place
City, State, Zip:
Fort Pierce , FL , 34951
Owner:
Design Location:
FL, ST LUCIE CO INTL
Builder Name:: ADAM HOMES
Permit Office:
Permit Number:
Jurisdiction: 661000
County: St. Lucie (Florida Climate Zone 2 )
1; New construction or existing -
New.(From Plans)
10. Wall Type01573.5 sqft.)
Insulation Area
2. Single family or multiple family,
Detached
a.. Concrete Block - Int lnsul, Exterior
R=4.1 1399.30 ftZ
3. Number of units, if multiple family .
1
b. Frame - Wood, Adjacent
R=13.0 174.22 ftz
c. N/A
R= ftZ
4. Number of Bedrooms
4
d. N%A
R=: ftZ
5. Is this a worst case?
No
11: Ceiling Types (1675.0 sqft.)
Insulation (Area
a. Under Attic (Vented)
R=30.0 1635.00 ftZ
6. Conditioned floor area above grade (ftZ)
1635
b. Knee Wall (Vented)
R=19.0 40.00 ftZ
Conditioned floor area below grade (ftZ)
0
c. N/A
R= {{2
7: Windows(204.8 sqft.) Description
Area
12. Ducts
R ftZ
a. U-Factor: Dbl, U=0.33
152.55 ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 327
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
18.33 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.31
a. Central Unit
28.4 SEER:'15.00
c. U-Factor: Dbl, U=0.55
17.78 ftZ
0
SHGC: SHrhang
Area Weighted Average Overhang Depth: 4.273 ft.
14Heating systems
. n9 y
kBtu/hr Efficiency
Y
Area Weighted Average SHGC:
0.276
a. Electric Heat Pump
28.2 HSPF:8.50
8. Skylights
Area
c. U-Factor:(AVG) N/A
ftZ
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons.. .
llons
9. Floor Types (1635.0 sgft.)
Insulation Area
EF:
a. Slab -On -Grade Edge Insulation
R=0.0 1635.00 ftZ
b: Conservation features
b. N/A
R= ftZ
None
c. N/A
R= ftZ
16. Credits
Pstat
Glass/Floor Area: 0.125 .
Total Proposed Modified Loads: 155.54
PASS
Total Baseline
Loads: 55.80
I hereby certify that the plans a' ations covered by..+ ffl'
this: calculation are in corhpli e t e o idr'rgy
Code.
PREPARED BY:
DATE: n4-1s-)n91 n,,hhi t<eonnany .. .
I hereby certify that this building as designed, is in compliance
with the Florida C�
OWNER/AG .
DATE:
Revie-ftf the plans and
specifications covered by this
calculation indicates compliance
with the:Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house.
4/16/2021 1:19 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020 Compli oftw 7 Page 1 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 117 Block 5 Waterstone 1 Bedrooms: 4
User Conditioned Area: 1635
Total Stories: 1
1 Worst Case: No
ADAM HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
117-5
Waterstone
5330 San Benedetto PI
St. Lucie
Fort Pierce ,
FL , 34951
CLIMATE
/
V Design Location
Design Temp
T Y Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degre Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1635 15859.5
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1635 15859.5 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0
1635 ft2 ----
0.29 0 0.71
ROOF
/
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1828 ft2 408 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1635 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
1635 ft2 0.11
40 ft2 0.11
Wood
Wood
4/16/2021 1:19 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software - Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHF['KI ISRT RFPnRT
WALLS
Adjacent Space
Cavity Width Height
-
Sheathing Framing Solar Below
o
1 NE
Exterior Concrete Block - Int Insul Main
4.1 43 1 8
11
384.2 ft'
0
0 0.6
0
2 NW
Exterior Concrete Block - Int Insul Main
4.1 17 1 10
8
182.2 ft'
0
0 0.6
0
3 SW
Exterior Concrete Block - Int Insul Main
4.1 45 5 10
8
484.4 ft'
0
0 0.6
0
4 SE
Exterior Concrete Block - Int Insul Main
4.1 32 8 10
8
348.4 ft'
0
0 0.6
0
5 -
Garage Frame - Wood Main
13 16 4 10
8
174.2 ftZ
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
NW Insulated Main
None
.25
3
6 9
20.3 ftZ
2
- Wood Main
None
.25
I 2
8
6 8
17.8 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V/ #
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
NE 1 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ftZ
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
2
NW 2 Vinyl Low-E Double Yes
0.33 0.31 N
5.0 ft'
6 ft 9 in
2 ft 6 in
Drapes/blinds
None
3
NW 2 Vinyl Low-E Double Yes
0.33 0.21 N
16.2 ft'
1 ft 5 in
0 ft 10 in
Drapes/blinds
None
4
NW 2 Vinyl Low-E Double Yes
0.33 0.31 N
13.3 ftz
6 ft 9 in
4 ft 0 in
Drapes/blinds
None
5
SW 3 Vinyl Low-E Double Yes
0.33 0.23 N
6.9 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
6
SW 3 Vinyl Low-E Double Yes
0.33 0.23 N
64.8 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
7
SE 4 Metal Low-E Double Yes
0.55 0.7 N
17.8 ft'
11 ft 4 in
1 ft 0 in
Drapes/blinds
None
8
SE 4 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft'
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
9
SE 4 Vinyl Low-E Double Yes
0.33 0.23 N
32.4 ft'
11 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
400 ft' 400 ft'
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000431 1850.3 101.51 190.58
.1365
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
4/16/2021 1:19 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
/ ---- Supply ----
---- Return ---
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 327 ft'
Main
81.75 ft Proposed Qn
Main
--- cfm
65.4 cfm 0.04 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb
Heating f X� Jan f X� Feb
Mar
Mar
f
A r
APr f
Jul
Jun Jul
Ma X Jun ri
May I
u
Mug Aug
Se
SeP
ri
Oct
Oct
Nov
Nov
Dec
DecVenting
[ Jan [ Feb
XMar
[
A r [
Ma Jun Jul
Se
[X)
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
PM
78
78
78
78
78
78 78 78
78
78
78
78
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
PM
66
68
66
68
66
68
66 66 68
68
68
68
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
PM
66
66
66
66 66 68
68
68
68
68
68
68
68
68
68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft'
0 ft
0.3
Main
4/16/2021 1:19 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
`1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
5330 San Benedetto Place, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
3. Number of units, if multiple family
1
c. N/A
4I Number of Bedrooms
4
d. N/A
11. Ceiling Type and insulation level
5. Is this a worst case?
No
a: Under Attic (Vented)
6. Conditioned floor area (ft2)
1635
b. Knee Wall (Vented)
7. Windows- Description
Area
c. N/A
a. U-Factor: Dbl, U=0.33
152.55 ft2
12. Ducts, location & insulation level
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
b. 0-Factor: Dbl, U=0,33 _
18.33 ft;
SHGC: SHGC=0.31
13. Cooling systems
C. U-Factor: Dbl, U=0.55
17.78 ft2
a. Central Unit
SHGC: SHGC=0.70
d. U-Factor: other (see details)
16.1.9 ft2
SHGC: . other (see details)
14. Heating systems
Area Weighted Average Overhang Depth:
4.273 ft.
a. Electric Heat Pump
Area Weighted Average SHGC:
0.276
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2
a. Electric
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
_ Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1635.00 ft2
Credits (Performance method)
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder SignatDate:
Address of New Home:
City/FL Zip:
Insulation
Area
R=4.1
1399.30 ft2
R=13.0
174.22 W .
R=
ft2
R=,
ft2
Insulation
Area
R=30.0
'1636.00 ft2
R=19.0
40.00 ft2 .
R=
ft2
R ft2
6 327
kBtu/hr Efficiency
28.4 SEER:15.00
kBtu/hr Efficiency
28.2 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat -
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/16/2021 1:19 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1