HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
1"';
Project Name: MONTANA RES RESIDENCE
Street: TRANQUILITY BASE LANE
City, State, Zip: FORT PIERCE, FL,
Owner: THOMAS AND ELIZABETH MONTANA
Design Location: FL, Fort Pierce
Builder Name: PLM CONSTRUCTION
Permit Office: ST LUCIE COUNTY
Permit Number:
Jurisdiction: ST LUCIE COUNTY
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2808.8 sqft.)
Insulation Area
a. Concrete Block - Int Insul, Exterior
R=4.1 2568.80 ft2
2. Single family or multiple family Single-family
b. Frame - Wood, Adjacent
R=11.0 240.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
10. Ceiling Types (2733.0 sqft.)
R= ft2
Insulation Area
5. Is this a worst case? No
a Roof Deck (Unvented)
R=20.0 2733.00 ft2
6. Conditioned floor area above grade (11112) 2733
b. N/A
R= ft2
c. N/A
R= ft2
Conditioned floor area below grade (W) 0
11. Ducts
R ft2
7. Windows(414.8 sqft.) Description Area
a Sup: Attic, Ret: Attic, AH: Garage
6 130
a. U-Factor: Sgl, U=0.65 192.00 ft2
b. Sup: Attic, Ret: Attic, AH: Attic
6 130
SHGC: SHGC=0.21
12. Cooling systems
kBtu/hr Efficiency
.58 174.33 ft2
b. U-Factor: Sgl, U=0 .58
a Central Unit
24.0 SEER:16.00
SHGC: SHGC=
b. Central Unit
24.0 SEER:16.00
c. U-Factor: Sgl, U=0.69 40.00 ft2
SHGC: SHGC=0.22
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 8.50 ft2
a. Electric Strip Heat
17.0 C00:1.00
SHGC: other (see details)
b. Electric Strip Heat
17.0 COP:1.00
Area Weighted Average Overhang Depth: 8.172 ft.
Area W eighted Average SHGC: 0.225
14. Hot water systems
a. Electric Tankless
Cap: 1 gallons
8. Floor Types ' (2733.0 sqft.) Insulation Area
EF: 0.990
a Slab -On -Grade Edge Insulation R=0.0 2733.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Total Proposed Modified Loads: 90.35
PASS
Glass/Floor Area: 0.152
Total Baseline Loads: 91.55
+
I hereby certify that the plans and specifications covered by
Review of the plans and
O�t$E S7,4?�
this calculation are in compliance with the Florida Energy
specifications covered by this
.y , ; . Off,
Code.
calculation indicates compliance
with the Florida Energy Code.
ti rr+++r ='"- -sr"l°,•°`� ��
PREPARE Y:
�-
Before construction is completed
1;1ij�►
DATE: 14- 2
this building will be inspected for
compliance with Section 553.908
* =}
I hereby certify that this building, as designed, is in compliance
Florida Statutes.,
c�`t
COD S
with the Florida Energy Code.
OWNER/AG T
BUILDING OFFICIAL:
DATE: a2
DATE:
4
._, - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure
qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
10/13/2020 4:09 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
MONTANA RES RESIDENCE
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2733
Lot #
Owner Name:
THOMAS AND ELIZABETH
M
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
PLM CONSTRUCTION
Rotate Angle:
0
Street:
TRANQUILITY BASE L
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
ST LUCIE COUNTY
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
AHU 1
1492
15190
2
AHU 2
1241
13609
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
MASTER BEDROO
315
3465 No
0
1
1
Yes
Yes
Yes
2
M TOILET
30
300 No
0
1
Yes
Yes
Yes
3
M BATH
246
2460 No
0
1
Yes
Yes
Yes
4
M HALL
40
400 No
0
1
No
Yes
Yes
5
M WIC
168
1680 No
0
1
Yes
Yes
Yes
6
FOYER
90
1080 No
0
1
Yes
Yes
Yes
7
LAUNDRY RM
130
1300 No
0
1
Yes
Yes
Yes
8
GREAT RM
352
4224 No
0
1
Yes
Yes
Yes
9
PANTRY
30
300 No
0
1
No
Yes
Yes
10
KITCHEN/NOOK
452
4520 Yes
0
1
Yes
Yes
Yes
11
ENTRY WAY
78
780 No
0
1
No
Yes
Yes
12
BEDROOM 2
169
1690 No
0.
1
1
Yes
Yes
Yes
13
WIC 2
15
150 No
0
1
No
Yes
Yes
14
BATH 2
50
500 No
0
1
Yes
Yes
Yes
15
BEDROOM 3
169
1690 No
0
1
1
Yes _
Yes
Yes
16
CLST 3
18
180 No
0
1
Yes
Yes
Yes
17
BATH 3
54
540 No
0
1
Yes
Yes
Yes
18
THEATER
270
2970 No
0
1
Yes
Yes
Yes
19
HALL
57
570 No
0
1
Yes
Yes
Yes
10/13/2020 4:09 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO
45 ft
0
315 ft2
____
1
0
0
2 Slab -On -Grade Edge Insulation
M TOILET
5 ft
0
30 ft2
----
1
0
0
3 Slab -On -Grade Edge Insulation
M BATH
14 ft
0
246 ft2
----
1
0
0
4SIab-On-Grade Edge Insulation
M HALL
1 ft
0
40 ft2
----
1
0
0
5 Slab -On -Grade Edge Insulation
M W IC
34 ft
0
168 ft2
____
1
0
0
6 Slab -On -Grade Edge Insulation
FOYER
9 ft
0
90 ft2
----
1
0
0
7 Slab -On -Grade Edge Insulation
LAUNDRY RM
8 ft
0
130 ft2
----
1
0
0
8SIab-On-Grade Edge Insulation
GREAT RM
16 ft
0
352 ft2
_---
1
0
0
9 Slab -On -Grade Edge Insulation
PANTRY
1 ft
0
30 ft2
----
1
0
0
10SIab-On-Grade Edge Insulation
KITCHEN/NOOK
21 ft
0
452 ft2
----
1
0
0
11SIab-On-Grade Edge Insulation
ENTRY WAY
1 ft
0
78 ft2
----
1
0
0
12Slab-On-Grade Edge Insulation
BEDROOM'2
13 ft
0
169 ft2
----
1
0
0
13SIab-On-Grade Edge Insulation
WIC 2
1 ft
0
15 ft2
____
1
0
0
14SIab-On-Grade Edge Insulation
BATH 2
5 ft
0
50 ft2
____
1
0
0
15SIab-On-Grade Edge Insulation
BEDROOM 3
13 ft
0
169 ft2
__--
1
0
0
16SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
18 ft2
----
1
0
0
17SIab-On-Grade Edge Insulation
BATH 3
6 ft
0
54 ft2
----
1
0
0
18Slab-On-Grade Edge Insulation
THEATER
48 ft
0
270 ft2
----
1
0
0
19SIab-On-Grade Edge Insulation
HALL
3.6 ft
0
57 ft2
----
1
0
0
ROOF
/
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
v # Type Materials Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip Composition shingles 3057 ft2
0 ft2 Medium
N
0.4 No 0.9
No
20
26.6
ATTIC
V # Type
Ventilation
Vent
Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0 2733 ft2
N N
10/13/2020 4:09 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Unvented) MASTER BEDRO,
0
Blown
315 ft2
0.1
Wood
2
Under Attic (Unvented) M TOILET
0
Blown
30 ft2
0.1
Wood
3
Under Attic (Unvented) M BATH
0
Blown
246 ft2
0.1
Wood
4
Under Attic (Unvented) M HALL
0
Blown
40 ft2
0.1
Wood
5
Under Attic (Unvented) M W IC
0
Blown
168 ft2
0.1
Wood
6
Under Attic (Unvented) FOYER
0
Blown
90 ft2
0.1
Wood
7
Under Attic (Unvented) LAUNDRY RM
0
Blown
130 ft2
0.1
Wood
8
Under Attic (Unvented) GREAT RM
0
Blown
352 ft2
0.1
Wood
9
Under Attic (Unvented) PANTRY
0
Blown
30 ft2
0.1
Wood
10
Under Attic (Unvented) KITCHEN/NOOK
0
Blown
452 ft2
0.1
Wood
11
Under Attic (Unvented) ENTRY WAY
0
Blown
78 ft2
0.1
Wood
12
Under Attic (Unvented) BEDROOM 2
0
Blown
169 ft2
0.1
Wood
13
Under Attic (Unvented) WIC 2
0
Blown
15 ft2
0.1
Wood
14
Under Attic (Unvented) BATH 2
0
Blown
50 ft2
0.1
Wood
15
Under Attic (Unvented) BEDROOM 3
0
Blown
169 ft2
0.1
Wood
16
Under Attic (Unvented) CLST 3
0
Blown
18 ft2
0.1
Wood
17
Under Attic (Unvented) BATH 3
0
Blown
54 ft2
0.1
Wood
18
Under Attic (Unvented) THEATER
0
Blown
270 ft2
0.1
Wood
19
Under Attic (Unvented) HALL
0
Blown
57 ft2
0.1
Wood
WALLS
Adjacent
Cavi ty
Width
Height
Sheathing Framing
Solar
Below
Space
Ft In
Ft
In
Area
R-Value
Eractann
Ahsor
rrqrle%
1
N
Exterior Concrete Block - Int InsuMASTER BE
4.1
-le
16
0 11
0
176.0 ft2
0
0
0.4
0
2
E
Exterior Concrete Block - Int InsuMASTER BE
4.1
19
0 11
0
209.0 ft2
0
0
0.4
0
3
W
Exterior Concrete Block - Int InsuMASTER BE
4.1
10
0 11
0
110.0 ft2
0
0
0.4
0
4
E
Exterior Concrete Block - Int Insul M TOILET
4.1
5
0 10
0
50.0 ft2
0
0
0.4
0
5
E
Exterior Concrete Block - Int Insul M BATH
4.1
14
0 10
0
140.0 ft2
0
0
0.4
0
6
E
Exterior Concrete Block- Int Insul M W IC
4.1
9
0 10
0
90.0 ft2
0
0
0.4
0
7
S
Exterior Concrete Block - Int Insul M W IC
4.1
20
0 10
0
200.0 ft2
0
0
0.4
0
8
W
Exterior Concrete Block- Int Insul M W IC
4.1
5
0 10
0
50.0 ft2
0
0
0.4
0
9
S
Exterior Concrete Block - Int Insul FOYER
4.1
9
0 12
0
108.0 ft2
0
0
0.4
0
10
S
Exterior Concrete Block - Int InsuLAUNDRY R
4.1
8
0 10
0
80.0 ft2
0
0
0.4
0
11
S
Garage Frame - Wood LAUNDRY R
11
5
0 10
0
50.0 ftz
0
0.1
0.4
0
12
N
Exterior Concrete Block - Int InsuIGREAT RM
4.1
16
0 12
0
192.0 ft2
0
0
0.4
0
13
N
Exterior Concrete Block - Int InsdKITCHEN/NO
4.1
11
0 10
0
110.0 ft2
0
0
0.4
0
14
E
Exterior Concrete Block - Int InsUKITCHEN/NO
4.1
10
0 10
0
100.0 ft2
0
0
0.4
0
15
S
Garage Frame - Wood ENTRY WAY
11
6
0 10
0
60.0 ft2
0
0.1
0.4
0
16
W
Exterior Concrete Block - Int InsuBEDROOM 2
4.1
13
0 10
0
130.0 ft2
0
0
0.4
0
17
S
Garage Frame - Wood BEDROOM 2
11
13
0 10
0
130.0 ft2
0
0.1
0.4
0
18
W
Exterior Concrete Block - Int Insul BATH 2
4.1
5
0 10
0
50.0 ft2
0
0
0.4
0
19
W
Exterior Concrete Block - Int InsuBEDROOM 3
4.1
13
0 10
0
130.0 ft2
0
0
0.4
0
20
W
Exterior Concrete Block - Int Insul CLST 3
4.1
2
0 10
0
20.0 ft2
0
0
0.4
0
21
W
Exterior Concrete Block - Int Insul BATH 3
4.1
6
0 10
0
60.0 ft2
0
0
0.4
0
10/13/2020 4:09 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 7
FORM R4ns-9n17 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Below
Space
h_lp Et
In Et
In
Area
R-Vqllle Fraction
Absor
22 N
Exterior Concrete Block - Int Insul THEATER 4.1 15
0 11
0
165.0 ft2
0
0 0.4
0
23 E
Exterior Concrete Block - Int Insul THEATER 4.1 14
0 11
0
154.0 ft2
0
0 0.4
0
24 W
Exterior Concrete Block - Int Insul THEATER 4.1 19
0 11
0
209.0 ft2
0
0 0.4
0
25 NE
Exterior Concrete Block - Int Insul HALL
4.1 3
7 10
0
35.8 ft2
0
0 0.4
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
v #
Ornt ID Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1 Metal
Low-E Single
Yes
0.69 0.22
Y
40.0 ft2
1 it 6 in
1 ft 4 in
None
None
2
E 2 Metal
Low-E Single
Yes
0.58 0.24
Y
20.0 ft2
1 it 6 in
1 ft 4 in
None
None
3
E 4 Metal
Low-E Single
Yes
0.58 0.24
Y
6.0 ft2
1 ft 6 in
1 it 4 in
None
None
4
E 5 Metal
Low-E Single
Yes
0.58 0.24
Y
5.0 ft2
1 ft 6 in
1 it 4 in
None
None
5
E 5 Metal
Low-E Single
Yes
0.58 0.24
Y
6.0 ft2
1 ft 6 in
1 it 4 in
None
None
6
S 7 Metal
Low-E Single
Yes
0.58 0.24
Y
10.0 ft2
1 it 6 in
1 ft 4 in
None
None
7
S 9 Metal
Low-E Single
Yes
0.45 0.26
Y
8.5 ft2
6 it 6 in
1 it 4 in
None
None
8
S 9 Metal
Low-E Single
Yes
0.58 0.24
Y
48.0 ft2
6 it 6 in
1 ft 4 in
None
None
9
S 10 Metal
Low-E Single
Yes
0.58 0.24
Y
10.0 ft2
1 it 6 in
1 ft 4 in
None
None
10
N 12 Metal
Low-E Single
Yes
0.65 0.21
Y
96.0 ft2
10 it 6 in'
1 ft 4 in
None
None
11
N 13 Metal
Low-E Single
Yes
0.65 0.21
Y
48.0 ft2
10 it 6 in
1 ft 4 in
None
None
12
E 14 Metal
Low-E Single
Yes
0.65 0.21
Y
48.0 ft2
20 it 6 in
1 ft 4 in
None
None
13
W 16 Metal
Low-E Single
Yes
0.58 0.24
Y
15.0 ft2
1 it 6 in
1 ft 4 in
None
None
14
W 18 Metal
Low-E Single
Yes
0.58 0.24
Y
9.0 ft2
1 it 6 in
1 it 4 in
None
None
15
W 19 Metal
Low-E Single
Yes
0.58 0.24
Y
15.0 ft2
1 it 6 in
1 ft 4 in
None
None
16
W 21 Metal
Low-E Single
Yes
0.58 0.24
Y
9.0 ft2
1 ft 6 in
1 it 4 in
None
None
17
NE 25 Metal
Low-E Single
Yes
0.58 0.24
Y
21.3 ft2
14 ft_6 in
1 it 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
1008 ft2
1008 ft2
24 it
10 it
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 W holehouse Proposed ACH(50)
.000335
2399.9 131.75
247.78
.1295
5
HEATING SYSTEM
#
System Type
Subtype
Speed
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1
17
kBtu/hr
1
sys#1
2
Electric Strip Heat/
None
COP:1
17 kBtu/hr
2
sys#2
10/13/2020 4:09 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 7
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
. Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Single SEER: 16
24 kBtu/hr
720 cfm 0.8
1
sys#1
2 Central Unit/
Split
Single SEER: 16
24 kBtu/hr
720 cfm 0.8
2
sys#2
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt Conservation
1 Electric Tankless
Garage
0.99 1 gal
55.1 gal
120 deg None
SOLAR HOT WATER SYSTEM
FSEC
I
Collector Storage
Cert # Company Name
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25 CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT QN
RLF
Heat Cool
1 Attic 6 130 ft2
Attic
13 ft2 Default Leakage
Garage
(Default) c(Default) c
1 1
2 Attic 6 130 ft2
Attic
13 ft2 Default Leakage
Attic
(Default) c(Default) c
2 2
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan Feb [[ ]] Mar
Apr
Ma X Jun X Jul
X Au
X] Se [ Oct
Nov
Dec
HeatinX� JanX� Feb [X] Mar
APr
May Jun Jul
Au4
] SeP [ Oct
Nov
Dec
VentingJan Feb [[XX]] Mar
[
l
Apr
[ May [ Jun [ Jul
l l l
[ Aug
t
[ ] Se [ Oct X
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2
3
4 5 6
7
8 9 10
11
12
Cooling (W D) AM 78
78
78
78 78 78
78
78 80, 80
80
80
PM 80
80
80
80 78 78
78
78 78 78
78
78
Cooling (W EH) AM 78
78
78
78 78 78
78
78 80 80
80
80
PM 80
80
80
80 78 78
78
78 78 78
78
78
Heating (W D) AM 65
65
65
65 65 65
65
68 68 68
68
68
PM 68
68
68
68 68 68
68
68 68 68
68
68
Heating (WEH) AM 65
65
65
65 65 65
65
68 68 68
68
68
PM 68
68
68
68 68 68
68
68 68 68
68
68
=
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
GREAT ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
AHU CLST
Default(8 Ibs/sq.ft.
ft2
ft
0.3
HALLWAY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLST 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8lbs/sq.ft.
ft2
ft
0.3
LIVING ROOM
10/13/2020 4:09 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 7
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
ft2 ft 0.3
BATH 3
Default(8 Ibs/sq.ft.
ft2 ft 0.3
M BATH
Default(8 Ibs/sq.ft.
ft2 ft 0.3
M W IC
Default(8 Ibs/sq.ft.
ft2 ft 0.3
MASTER BEDROO
Default(8 Ibs/s .ft.
ft2 ft 0.3
UTILITY ROOM
10/13/2020 4:09 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 7 of 7
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location varies
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 3 13. Cooling system: Capacity 48.0
a) Split system SEER 16.0
5. Is this a worst case? (yes/no) 5. No b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 2733 d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.620
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.225
c) Area 7c. 414.8
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
10131. 11.0
10132.
11 a. 0.0
11 b.-
1 1c.
11 d. No
14. Heating system: Capacity 34.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
c) Electric resistance COP 1.0
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.99
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b) Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
f) Programmable thermostat No
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature Date: /01o2a2 "010-
Address of New Home: TRANQUILITY BASE LANE City/FL Zip: FORT PIERCE FL
10/13/2020 4:09:39 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name:
MONTANA RES RESIDENCE Builder Name: PLM CONSTRUCTION
Street:
TRANQUILITY BASE LANE Permit Office:
ST LUCIE COUNTY
City, State, Zip:
FORT PIERCE, FL, Permit Number:
Y
Owner:
THOMAS AND ELIZABETH MONTANA Jurisdiction:
ST LUCIE COUNTY
w
Design Location:
FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in andropped g
ed ceilin /soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be sealed.
shall be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottorr
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring a
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. in audmon, inspection of iog waiis snaii be in accordance witrn the provisions of IGG-400.
10/13/2020 4:09 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1