-- wrightsoft® Project Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project• • For: THOMAS AND ELIZABETH MONTANA PLM CONSTRUCTION TRANQUILITY BASE LANE, FORT PIENCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Job: Date: Oct 13, 2020 By: Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 16318 Btuh Ducts 3268 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 19586 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Cooling Area (ft2) 1491 1491 Volume (ft3) 15180 15180 Air changes/hour 0.29 0.15 Equiv. AVF (cfm) 74 37 Heating Equipment Summary Make Trade Model AH R I ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.7 kW 19293 Btuh 22 0 800 cfm 0.041 cfm/Btuh 1.00 in H2O 90 OF 75 OF 15 OF M 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 12808 Btuh Ducts 4734 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 16665 Btuh Latent Cooling Equipment Load Sizing Structure 3054 Btuh Ducts 1257 Btuh _ Central vent (0 cfm) 0 Btuh (none) Equipment latent load 4311 Btuh Equipment Total Load (Sen+Lat) 20976 Btuh Req. total capacity at 0.70 SHR 2.0 ton Cooling Equipment Summary Make Trane Trade TRAN E Cond 4TTR40251_1 Coil TEM6AOB24H21++TDR AH R I ref 7567540 Efficiency 13.0 EER, 16 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 800 cfm Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigt hs nft- 2020-Oct-13 16:11:07 •W Right -Suite® Universal 2019 19.0.08 RSUOB101 Page 1 ..\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Cale = MJ8 Front Door faces: S Pro ect Summar Job: -�- wrightsoft® AH� Date: Oct 13, 2020 U2 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Project Information For: THOMAS AND ELIZABETH MONTANA PLM CONSTRUCTION TRANQUILITY BASE LANE, FORT PIENCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17319 Btuh Structure 12882 Btuh Ducts 3025 Btuh Ducts 4386 Btuh Central vent (0 cfm) 0 Btuh 'Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20343 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Btuh Infiltration Equipmenf sensible load 16405 Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3655 Btuh Ducts 1155 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 1242 1242 Equipment latent load 4809 Btuh Volume (ft3) 13620 13620 Air changes/hour 0.35 0.17 Equipment Total Load (Sen+Lat) 21214 Btuh Equiv. AVF (cfm) 79 40 Req. total capacity at 0.70 S H R 2.0 ton Heating Equipment Summary I Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR4025L1 AHRI ref Coil TEM6AOB24H21++TDR AH R I ref 7567540 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 12.1 kW Sensible cooling 16800 Btuh Heating output 41352 Btuh Latent cooling 7200 Btuh Temperature rise 47 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Pi-ii- MrIla +tsoff't- 2020-Oct-13 16:11:07 � � ^ Right -Suite@ Universal 2019 19.0.08 RSU03101 Page 2 ACCA ..\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJ8 Front Door faces: S wrightsoftm Right-J® Worksheet Job: AHU 1 Date: Oct 13, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name AHU 1 HALL 2 Exposed wall 119.6 ft 3.6 ft 3 Room height 10.2 ft 10.0 ft heat/cool 4 Room dimensions 1.0 x 56.5 ft 5 Room area 1491.0 ft2 56.5 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btu ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 0.143 0.580 0.580 0.580 0.143 - n n n n ne 4.00 0.00 16.24 0.00 4.00 2.19 0.00 13.73 0.00 2.19 275 0 48 0 36 227 0 0 0 15 909 0 780 0 62 497 0 659 0 34 0 0 0 0 36 0 0 0 0 15 0 0 0 0 62 0 0 0 0 34 VL(; 2 glazinq, clr low-e 13A-4ocs 2 glazing, clr low-e 0.580 0.143 0.580 ne ` e a 16.24 4.00 0.00 25.14 . 2.19 0.00 21 254 0 0 206 0 336 825 0 520 451, 0 21 0 0 0 0 0 336 0 0 520 0 0 2 glazing, cir low-e 2 glazing,, clr low-e a 0.580 0.580 a ° e 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 01 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, 0.580 0.580 0.580 a s s 16.24 0.00 0.00 31.76 0.00 0.00 48 80 0 0 70 0 780 280 0 1525 153 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 2 glazing, clr low-e 0.580 0.580 s s 16.24 0.00 13.73 0.00 10 0 20 0 162 0 137 0 0 0 0 0 0 0 0 0 yJ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e C 0.143 0.580 0.580 w w w 4.00 16.24 16.24 2.19 . 31.76 31.76 599 . 18 30 551 0 0 2206 292 487 1206 572 953 0 0 0 0 0 0 0 0 0 0 0 0 1{-�( C 16X19-0ad 0.408 1.59 1.37 1491 1491 2364 2040 57 57 90 77 F 22A-tph ' ., 1.358 38.02 0.00 1491 120 4547 0 57 4 136 0 6 c) AED excursion 0 -32 Envelope loss/gain 14029 8745 623 598 12 a) Infiltration 2289 613 66 18 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 3450 0 Subtotal (lines 6 to 13) 16318 12808 689 616 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 -689 -616 14 Subtotal 16318 12808 0 0 15 Duct loads 20% 37% 3268 4734 20% 379/. 0 0 Total room load 19586 17542 0 0 Air required (cfm) 800 800 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -:- wrlghtsoTt 2020-Oct-13 16:11:07 Right -Suite@ Universal 2019 19.0.08 RSU08101 Page 1 ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJ8 Front Door faces: S -- wrightsoft Right-J® Worksheet Job: AHU 1 Date: Oct 13, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 3 THEATER 2 Exposed wall 6.0 ft 48.0 ft 3 Room height 10.0 ft heat/cool 11.0 ft heat/cool 4 Room dimensions 6.0 x 9.0 ft 1.0 x 270.0 ft 5 Room area 54.0 ft2 270.0 ft2 Ty Construction number U-value (Btuh/ft2-OF) Or HTM (Btu hlft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 0.580 0.580 "n In In 4.06 0.00 16.24 2.19 0.00 13.73 0 0 0 0 0 0 0 0 0 0 0 0 165 0 0 165 0 0 661 0 0 361 0 0 11 2 glazing, cir low-e 13A-4ocs 0.580 0.143 n ne 0.00 4.00 0.00 2.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W I--G 2 glazing, clr low-e 13A-4ocs 2 glazing, cir low-e 0.580 0.143 0.560 , ne a a 16.24 4.00 0.00 25.14 2.19 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 154 0 0 154 0 0 617 0 0 337 0 2 glazing, clr low-e 2glazing, cir low-e 2 glazing,-'cir low-e 13A-4ocs 2 glazing, clr low-e 0.580 0.580 0.560 0.143 0.580 a a a s s 0:00 0.00 16.24 4.00 0.00 0.00 0.00 31.76 2.19 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 yyJJ 2 glazing, clr low-e 2 glazing, clr low-e 0.580 0.580 s s 16.24 0.00 13.73 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A-4ocs 2 glazing, clrlow-e 2 glazing, cir low-e 0.143 0.580 0.580 w w w 4.00 16.24 16.24 2.19 31.76 31.76 60 9 0 51 0 0 204 146 0 112 286 0 209 0 0 209 0 0 837 0 0 457 0 0 C 16X19-Oad 0.408 1.59 1.37 54 54 86 74 270 270 428 369 F 22A-tph 1.358 38.02 0.00 54 6 228 0 270 48 1825 0 6 c) AED excursion 96 -149 Envelope loss/gain 664 567 4367 1376 12 a) Infiltration 110 30 971 260 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 1200 Subtotal (lines 6 to 13) 775 597 5339 2836 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 245 157 174 156 14 Subtotal 1019 753 5513 2992 15 Duct loads 201% 37% 204 278 20% 371/6 1104 1106 Total room load 1223 1032T 6617 4098 Air required (cfm) 50 47 270 187 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. wr1gF2tsoft- 2020-Oct-13 16:11:07 Right -Suite@) Universal 2019 19:0.08 RSU08101 Page 2 Aeuk ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJ8 Front Door faces: S + wrightsoft Right-J® Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Oct 13, 2020 By: 1 Room name CLST 3 BEDROOM 3 2 3 Exposed wall Room height 2.0 ft 10.0 ft heat/cool 13.0 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 2.0 x 9.0 ft 18.0 ftz 13.0 x 13.0 ft 169.0 ftz Ty Construction number U-value (Btuh/ftz°F) Or HTM (Btuh/ft2) Area (ftz) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ 13A-flocs 2 glazing, clr low-e 2 glazing, cir low-e 0.143 0.580 0.580 n n, n 4:00 0.00 16.24 2.19 0.00 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, cU low-e 13A-4ocs 2glazinq, clr,low-e 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low-9 2 glazing, clr low-e 2 glazing, cir low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 16X19-0ad 0.580 0.143 0.580 0.143 0.580 0.580 10.580 0.580 0.143 0.580 0.580 0.580 0.143 0.580 0:580 0.408 n ne ne a a a a e`' s s s s w w w 0.00 4.00 16.24 4.00 0.00 10.00 0.00 16.24 4.00 0.00 16.24 0.00 4.00 16.24 16.24 1.59 0.00 2.19 25.14 2.19 0.00 . 0.00 0.00 31.76 2.19 0.00 13.73 0.00 2.19 31.76 31.76 1.37 0 0 0 0 0 0 0 0 0 0 0 0 20 0 0 18 0 0 0 0 0 0 0 0 0 0 0 0 20 0 0 18 0 0 0 0 0 0 0 0 0 0 i 0 0 80 0 0 29 0 0 0 0 0 0 0 0 0 0 0 0 44 0 0 25 0 0 0 0 0 0 0 0 0 0 0 0 130 0 15 169 0 0 0 0 0 0 0 0 0 0 0 0 115 0 0 169 0 0 0 0 0 0 0 0 0 0 0 0 460 0 244 268 0 0 0 0 0 0 0 0 0 0 0 0 252 0 476 231 N13A-4ocs C F 22A-tph 1.358 38.02 •0.00 18 2 76 0 169 13 494 0 6 c) AED excursion -4 135 Envelope loss/gain 185 64 1466 1095 12 a) Infiltration b) Room ventilation 37 0 10 0 239 0 64 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 250 Subtotal (lines 6 to 13) 221 74 1706 1409 Less extemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 -221 0 0 -74 0 0 200 1906 0 117 1526 15 Duct loads 20% 37% 0 0 20% 37% 382 564 Total room load 0 0 2287 2089 Air required (cfm) 0 0 1 931 95 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -FJA- 2020-Oct-1316:11:07 Right -Suite@ Universal 2019 19.0.08 RSU08101 Page 3 ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJ8 Front Door faces: S -}- wrightsoft Right-J® Worksheet Job: AHU 1 Date: Oct 13, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH 2 WIC 2 2 3 Eposed wall Room height 5.0 ft 10.0 ft heat/cool 0 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 5.0 x 10.0 ft 50.0 ftz 5.0 x 3.0 ft 15.0 ftz Ty Construction LI-value Or HTM Area (ft2) Load Area (ftz) Load number (Btuh/ftz°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VIl 13A-4ocs 2 glazing, cir low-e 2 glazing, clr:low-e ". 0:143 0.580 0.580 n ri , n 4.00 0.00 16.24 . 2.19 0.00 13.73 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 Ili-�LG;' 11 2 glazing, cir low-e 13A-4ocs 0.580 0.143 n no 0.00 4.00 0.00 2.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1LJ L 2 alazinq, cir low-e 13A-4ocs 2 glazing, cir low-e 0.580 0.143 0.580 ne a a 16.24 4.00 0.00 25.14 2.19 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -( 2 glazing, cir low-9 2 glazing, cir low-e 0.580 0.580 a a 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e ` s 2 glazing, cir low-e 2 glazing, 0.580 0.143 0.580 a s s 16.24 0.00 0.00 31.76 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, cir low-e 0.580 0.580 s s 16.24 0.00 13.73 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1al 13A-4ocs 2 glazing, cir low-e 2 glazing, cir low-e 0.143 0.580 0:580 w w w 4.00 16.24 16.24 2.19 31.76 31.76 50 9 . 0 41 0 0 164 146 0 90 286 .0 0 0 ' 0 0 0 0 0 0 0 0 0 0 C 16X19-0ad 0.408 1.59 1.37 50 50 79 68 15 15 24 21 F - 22A-tph 1.358 38.02 0.00 50 5 190 0 15 0 0 0 6 c) AED excursion 90 1 Envelope loss/gain 580 534 24 19 12 a) Infiltration 92 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 150 0 Subtotal (lines 6 to 13) 672 708 24 19 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 1 Subtotal 672 708 24 19 15 Duct loads 20% 379% 135 262 201/6 371% 5 7 Total room load 806 970 29 27 1 Air required (cfm) 33 44 1 1 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Of&- wrigFVt C'r*- 2020-Oct-1316:11:07 " Right -Suite® Universal 2019 19.0.08 RSU08101 Page 4 ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJ8 Front Door faces: S -- wrightsoftm Right-J® Worksheet Job: AHU 1 Date: Oct 13, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 ENTRYWAY 2 3 Eposed wall Room height 13.0 ft 10.0 ft heat/cool 0 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 13.0 x 13.0 ft 169.0 ftz 13.0 x 6.0 ft 78.0 ft2 Ty Construction number Ul-value (Btuh/ftz°F) Or HTM (Btuh/ftz) Area (ftz) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 2 glazing, clr low-e 2 glazing, clr'low-e 0.143 0:580 0:580 n -n n 4.00 0.00 16.24 2.19 , r 0.00' 13.73 0 0 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, cir low-e 13A-4ocs 2 glazing, cir low-e 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-9 2 glazing, clr low-e 2 glazing, clr low-e 13A-flocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, cir low-e 2 glazing,.cir low-e 16X19-Oad 22A-tph 0.580 0.143 0.580 0.143 0.580 0.580 0.580 0'580 0.143 0.580 0.580 0.580 0.143 0.580 0.5,80 0.408 1.358 n ne ne a . e a a a s s s s w w w 0.00 4.00 16.24 4.00 0.00 0.00 &00 16.24 4.00 0.00 16.24 0.00 4.00 16.24 16.24 1.59 38.02 0.00 2.19 25.14 2.19 0.00 0.00 0.00 31.76 2.19 0.00 13.73 0.00 2.19 31.76 31.76 1.37 0.00 0 0 0 0 0 0 0 0 0 0 0 0 130 0 15 169 169 0 0 0 0 0 0 0 0 0 0 0 0 115 0 0 169 13 0 0 0 0 0 0 0 0 0 0 0 0 460 0 244 268 494 0 0 0 0 0 0 0 0 0 0 0 0 252 0 476 231 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 78 78 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 78 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 124 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 107 0 V)J I--G 1-=-G W IL--GG C F 6 c) AED excursion 130 -5 Envelope loss/gain 1466 1090 124 101 12 a) Infiltration 239 64 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 350 0 Subtotal (lines 6 to 13) 1706 1504 124 101 Less edemal load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 50 1756 41 1545 -124 0 -101 0 15 Duct loads 20% 371% 352 571 201% 379/6 0 0 Total room load Air required (cfm) 2107 86 2116 96 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrlghtw4MV*- 2020-Oct-13 16:11:07 ""' "' Right -Suite® Universal 2019 19.0.08 RSU08101 Page 5 ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJ8 Front Door faces: S -+ wrightsoft Right-J® Worksheet Job: AHU 1 Date: Oct 13, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN/NOOK PANTRY 2 3 Exposed wall Room height 21.0 ft 10.0 ft heat/cool 0 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 451.5 ft 451.5 ft2 3.0 x 10.0 ft 30.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftz°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vh13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 0.143 0.580 0.580 n n n 4.00 0.00 16.24 2.19 0.00 13.73 110 0 48 62 0 0 248 0 780 136 0 659 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing, clr low-e 13A-4ocs 2 alazinq• clr low-e 13A-4ocs 2glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e ocs 2 glazing, clr low-e 2 glazing, 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, clrlow-e 2 glazing, clr low-e 16X19-0ad 22A-tph r 0.580 0.143 0.580 0.143 0.580 0.580 0.580 0:580 0.143 0.580 0.580 0.580 0.143 0.580 0.580 0.408 1.358 n ne ne a a a a a s s s s w w w 0.00 4.00 16.24 4.00 0.00 0.00 0.00 16.24 4.00 0.00 16.24 0.00 4.00 16.24 16.24 1.59 38.02 0.00 2.19 25.14 2;19 0.00 0.00 0.00 31.76 2. 0.0000 13.73 0.00 2.19 31.76 31.76 1.37 0.00 -0 0 0 100 0 0 0 48 0 0 0 0 0 0 0 452 452 0 0 0 52 0 0 0 0 0 0 0 0 0 0 0 452 21 0 0 0 208 0 0 0. 780 0 0 0 0 0 0 0 716 799 0 0 0 114 0 0 0 1525 0 0 0 0 0 0 0 618 0 0 0 0 0 0 .0 0 0 0 0 0 0 0 0 0 30 30 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 30 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 48 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 41 0 W I--(; VtJ C F 6 c) AED excursion -222 -2 Envelope loss/gain 3530 2829 48 39 12 a) Infiltration 386 103 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 1300 0 0 0 Subtotal (lines 6 to 13) 3916 4232 48 39 Less external load 0 0 0 0 Less transfer 0 0 0 0 14 Redistribution Subtotal 315 4231 280 4512 12 59 10 49 15 Duct loads 1 20% 37% 847 1668 20% 37% 12 18 Total room load Air required (cfm) 1 5079 207 6180 71 1 3 66 3 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -F1- wr1aft soft- 2020-Oct-13 16:11:07 CZ5ilk Right -Suite@ Universal 2019 19.0.08 RSU08101 Page 6 ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJ8 Front Door faces: S -- wrightsoft Right-J® Worksheet Job: AHU 1 Date: Oct 13, 2020 By: QUICK CALCS, INC. • 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY RM 2 3 Exposed wall Room height 8;0 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 13.0 ft 130.0 ftz Ty Construction number U-value (Btuh/ftz°F) Or HTM (Btuh/ft2) Area (ftz) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 y�J--L 13A floc$ ;. 2,glazing clrlow a 2_glazing '910ow e 2 glazing, cirlow-e 2 glazing, cir low-e 13A-flocs _ ° " 2'gla7ing„clr low"e. 2 glazing,"cirlow-e 2'glazing, cfclow-e 2 glaring, cir low-e 13A-4ocs 2 glazing, cir low-e 2 glazing, clr low-e 2 glazing, cir low a 13A flocs "" 2glazing, clrlowe , 2 glazing, ch_low-e 16X19-0ad 22A-tph 0;143 0.580 . 0:5� 0.580 0.143 0.580 -''0.143 �0:580 0:580 0.143 0.580 0.580 0.580 0.143 0.880 0.580 0.408 1.358 °,n" . n - n";u, n ne , ne ' e,, e .,e, " e s s s s w : w- "w T` - '400 0.00 16 2¢ 0:o0 4.00 16.24 "` 4 00 "0:00 ` -0.00 '. =°. 0.00 16.24 4.00 0.00 16.24 0.00 4.00 16.24 16.24 1.59 ,. 38:02 ° 219 0.00 �13.73 0.00 2:19 25.14 2.19 r 0:00 ; " 0.00 0.00 ' 31.76 2.19 0.00 13.73 0.00 2.19 31.76 31.76 1.87 400 °" ' - 0 • , 0 0 : 0 0 0 ° ,., . 0 °` 0 : 0 0 0 80 0 10 0 0 , 0 0 130 130 0 0 0 0 0 0 0 - 0 0 '0. 0 70 0 10 0 0 0 0 130 8 0 0 0 0 0 0 0 .0 0 � 0 0 280 0 162 0 0 0 0 206 304 0 0 0 0" 0 0 .0 0 0 0 ' 0 153 0 137 0 ' ` 0 0 .0 178 : 0 " ._. ` E--C' I_ C VLG13A-4ocs C F 6 c) AED excursion -35 Envelope loss/gain 953 433 12 a) Infiltration 147 39 b) Room ventilation 0 0 - 13 Internal gains: Occupants @ 230 Appliances/other 0 0 200 Subtotal (lines 6 to 13) 1100 672 Less external load 0 0 14 15 Less transfer Redistribution Subtotal Duct loads 201% 371% 0 39 1139 228 0 32 704 260 Total room load Air required (cfm) 1367 56 964 44 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. C wrlghlsoTt" 2020-Oct-1316:11:07 Right -Suite@) Universal 2019 19.0.08 RSU08101 Page 7 ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Cale = MJ8 Front Door faces: S +�- wrightsoftRight-J® Worksheet Job: AHU 2 Date: Oct 13, 2020 By: QUICK CALCS, INC. • 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fax: 772-466-6796 Email: QUICKCALCS @AOL. COM 1 2 3 4 5 Room name Fposed wall Room height Room dimensions Room area AHU 2 123.0 ft 11.0 ft 1242.0 ft2 M TOILET 5.0 ft 10.0 ft heat/cool 5.0 x 6.0 ft 30.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr law-6 13A-4ocs 2 glazinq, clr low-e 13A=4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ods 2 glazing, clr low-e 2 glazing, clr low-9 16X19-0ad 22A-tph 0.143 0.580 0.580 0.580 0.143 0.580 0.143 0.580 0.580 0.580 0.580 0.143 0.580 0.580 0.580 0.143 0.580 0.580 0.408 1.358 n n , n n ' ne ne a a a a a s s s s w w w 4.00 16.24 0.00 16.24 0.00 0.00 4.00 16.24 16.24 16.24 0.00 4.00 16.24 16.24 16.24 4.00 0.00 0.00 1.59 38.02 2.19 13.73 0.00 13.73 0.00 0.00 2.19 31.76 31.76 31.76 0:00 2.19 13.73 13.73 13.73 2.19 0.00 0.00 1.37 0.00 368 40 0 96 0 0 489 5 12 20 0 308 8 10 48 160 0 0 1242 1242 232 0 0 0 0 0 452 0 0 0 0 242 17 20 96 160 0 0 1242 123 929 650 0 1559 0 0 1810 81 195 325 0 967 136 162 780 641 0 0 1969 4677 508 549 0 1318 0 0 989 159 381 635 0 529 115 137 659 350 0 0 1699 0 0 0 0 0 0 0 50 0 6 0 0 0 0 0 0 0 0 0 30 30 0 0 0 0 0 0 44 0 0 0 0 0 0 0 0 0 0 0 30 5 0 0 0 0 0 0 176 0 97 0 0 0 0 0 0 0 0 0 48 190 0 0 0 0 0 0 96 0 191 0 0 0 0 0 0 0 0 0 41 0 W L--G --G �-G C F 6 c) AED excursion 0 8 Envelope loss/gain 14881 8029 511 336 12 a) Infiltration b) Room ventilation 2438 0 653 0 92 0 25 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 4200 0 0 0 Subtotal (lines 6 to 13) 17319 12882 603 361 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 17% 34% 0 0 0 17319 3025 0 0 0 12882 4386 17% 34%l 0 0 0 603 105 0 0 0 361 123 Total room load Air required (cfm) 20343 800 17268 800 1 709 1 28 483 22 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -Ork- 2020-Oct-13 16:11:07 "" - """-" Right -Suite@ Universal 2019 19.0.08 RSU08101 Page 8 ACC....\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJ8 Front Door faces: S +I+ wrightsoftm Right-J® Worksheet Job: AHU 2 Date: Oct 13, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M BATH M HALL 2 3 Exposed wall Room height 14.0 ft 10.0 ft heat/cool 0 ft 10.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 246.0 ft 246.0 ft2 10.0 x 4.0 ft 40.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftz°F) (Btuh/ft2) or perimeter (ft) (Etuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 U�J 13A-4ocs 2 glazing, cir Isla-e 2 glazing, cir low-e 0.143 0.580 0.580 n n n 4.00 '16.24 0.00 2.19 13.73 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I��------EGG 11 2 glazing, clr low-e 0.580 0.143 n ne 16.24 0.00 13.73 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 VEG13A-4ocs 2 glazinq, clr low-e 13A-4ocs 0.580 0:143 ne a 0.00 4.00 0.00 2.19 0 140 0 129 0 517 0 282 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.580 a 16.24 31.76 5 0 81 159 0 0 0 0 2 glazing, cir low-e 2 glazing, clr low-e 0.580 0.580 a a 16.24 16.24 31.76 31.76 6 0 0 0 97 0 191 0 0 0 0 0 0 0 0 0 2 glazing, clr low-e 13A-2gla4ocs 2 glazing, cir low-e 0.580 0.580 0.580 a s s 0.00 4.24 16.24 0.00 2.73 13.73 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, cir low-9 0.580 0.580 0.143 0.580 0.580 s s w w . w 16.24 16.24 4.00 0.00 0.00 13.73 13.73 2.19 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1N C 16X19-Oad 0.408 1.59 1.37 246 246 390 337 40 40 63 55 F 22A-tph 1.358 38.02 0.00 246 14 532 0 40 0 0 0 6 c) AED excursion 8 0 Envelope loss/gain 1618 976 63 55 12 a) Infiltration 258 69 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1875 1045 63 55 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 32 27 -63 -55 14 Subtotal 1907 1072 0 0 15 Duct loads 17 % 341% 333 365 17% 34% 0 0 Total room load 2240 1437 0 0 Air required (cfm) 88 67 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ,9 - wrtgF�tsoT�® 2020-Oct-13 16:11:07 �� """ "" " Right -Suite@ Universal 2019 19.0.08 RSU08101 Page 9 ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJB Front Door faces: S -1- wrightsoft Right-J® Worksheet Job: AHU 2 Date: Oct 13, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name M WIC FOYER 2 3 Exposed wall Room height 34.0 ft 10.0 ft heat/cool 9.0 ft 12.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 168.0 ft 168.0 ftz 10.0 x 9.0 ft 90.0 ftz Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btu h/ft2) Area (ftz) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 2 glazing 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-9 . 13A-4ocs 2 glazing. clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 0.580 `0:580 0.580 0.580 0.143 0.580 0.143 0.580 0.580 0.580 n n n n ne ne a a a "e 6.24 16.24 0.00 16.24 0.00 0.00 4.00 16.24 16.24 16.24 2.19 13.73 0.00 13.73 0.00 0.00 219 31.76 31.76 31.76 0 0 0 0 0 0 90 0 0 0 0 � 0' 0 0 0 0 90 0 0 0 0 0 0 0 0 0 360 0 0 0 0 0 0 0 0 0 197 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 W �( 2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing; clr low-e 2 glazing, clr low-e 16X19-0ad 22A-tph 0.580 0.143 0.580 0.580 0.580 0.143 0.560 0.580 0.408 1.358 a s s s s w w w 0.00 4.00 16.24 16.24 16.24 4.00 0.00 0.00 1.59 38.02 0.00 2.19 13.73 13.73 13.73 2.19 0.00 0.00 1.37 0.00 0 200 0 10 0 50 0 0 168 168 0 190 0 10 0 50 0 0 168 34 0 761 0 162 0 200 0 0 266 1293 0 416 0 137 0 109 0 0 230 0 0 108 8 0 48 0 0 0 90 90 0 52 8 0 48 0 0 0 90 9 0 207 136 0 780 0 0 0 143 342 0 113 115 0 659 0 0 0 123 0 yJ LI-�G C F l 6 c) AED excursion -5 11 Envelope loss/gain 3043 1084 1607 1021 12 a) Infiltration b) Room ventilation 626 0 168 0 199 0 53 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 700 1000 Subtotal (lines 6 to 13) 3668 1951 1806 2074 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 3668 0 0 1951 0 0 1806 0 0 2074 15 Duct loads 171/6 349/6 641 664 17% 34 % 315 706 Total room load Air required (cfm) 1 1 4309 169 2616 121 2122 831 2781 129 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. t Aa- wrtghtsoltw 2020-Oct-1316:11:07 .'ZuA Right -Suite@ Universal 2019 19.0.08 RSU08101 Page 10 ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJ8 Front Door faces: S wrightsof-r Right-JO Worksheet Job: AHU 2 Date: Oct 13, 2020 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name GREAT RM MASTER BEDROOM 2 3 E)posed wall Room height 16.0 ft 12.0 ft heat/cool 45.0 ft 11.0 ft heat/cool 4 5 Room dimensions Room area 22.0 x 16.0 ft 352.0 ft2 1.0 x 316.0 ft 316.0 ft2 Ty Construction number U-value (Btuh/ftz°F) Or HTM (Btu ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 --G 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, ,clr low-e 13A-4ocs 2 glazinq, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing; clr low-e 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing, 2 glazing, clr low-e 2 glazing, clr low-e 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 16X19-Oad 22A-tph 0.143 0.580 0.580 0:580 0.143 0.580 0.143 0.580 0.580 0.580 0.580 0.580 0.580 0.580 0.580 0.143 0.580 0.580 0.408 1.358 n n In in ne _ ne a a a a a s s s s w w w 4.00 16.24 0.00 16.24 0.00 0.00 4.00 16.24 16.24 16.24 0.00 16.24 6.24 16.24 16.24 4.00 0.00 0.00 1.59 38.02 2.19 13.73 0.00 13.73 0.00 0.00 2.19 31.76 31.76 31.76 0.00 3.73 13.73 13.73 13.73 2.19 0.00 0.00 1.37 0.00 192 0 0 96 0 0 0 0 0 0 0 0 0 0 0 0 0 0 352 352 96 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 352 16 ' 384 0 0 1559 0 0 0 0 0 0 0 0 0 0 0 0 0 0 558 608 210 0 0 1318 0 0 0 0 0 0 0 0 0 0 0 0 0 0 482 0 176 40 0 0. 0 0 209 0 0 20 0 0 0 0 0 110 0 0 316 316 136 0 0 0 0 0 189 0 0 0 0 0 0 0 0 110 0 0 316 45 545 650 0 0 0 0 757 0 0 325 0 0 0 0 0 440 0 0 501 1711 298 549 0 0 0 0 414 0 0 635 0 0 0 0 0 241 0 0 432 0 tE-�G Imo; yJ C F 6 c) AED excursion -10 -11 Envelope loss/gain 3110 2000 4928 2558 12 a) Infiltration 353 95 911 244 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 1500 0 0 1000 Subtotal (lines 6 to 13) 3463 3594 5839 3802 Less wdemal load 0 0 0 0 14 15 Less transfer Redistribution Subtotal Duct loads 17% 341% 0 23 3486 609 0 19 3614 1231 17% 34% 0 9 5848 1021 0 8 3810 1297 Total room load Air required (cfm) 4095 161 4844 224 6869 270 5107 237 Calculations approved by ACCA to meet all requirements rof Manual J 8th Ed. -FW 2020-Oct-13 16:11:07 " Right -Suite@ Universal 2019 19.0.08 RSU06101 Page 11 ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJ8 Front Door faces: S -t+ wrightsoft® Duct System Summary AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM iLroject intormation For: THOMAS AND ELIZABETH MONTANA, PLM CONSTRUCTION TRANQUILITY BASE LANE, FORT PIERCE, FL Job: Date: Oct 13, 2020 By: r Heating Cooling External static pressure 1.00 in H2O 1.00 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 1.00 in H2O 1.00 in H2O Supply / return available pressure 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O Lowest friction rate 1.000 in/100ft 1.000 in/100ft Actual air flow 800 cfm _ 800 cfm Total effective length (TEL) 213 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 c 970 33 44 1.000 6.0 Ox 0 VIFx 18.4 115.0 sti BATH 3 h 1223 50 47 1.000 6.0 Ox 0 VIFx 52.2 155.0 sty BEDROOM 2 c 2116 86 96 1.000 7.0 Ox0 VIFx 16.1 115.0 sti BEDROOM 3 c 2089 93 95 1.000 7.0 Ox 0 VIFx 32.8 135.0 st4 KITCHEN/NOOK c 3090 104 141 1.000 8.0 Ox 0 VIFx 35.6 135.0 st4 KITCHEN/NOOK-A c 3090 104 141 1.000 8.0 Ox0 VIFx 34.9 135.0 st4 LAUNDRY RM h 1367 56 44 1.000 6.0 Ox 0 VIFx 22.3 115.0 sti PANTRY c 66 3 3 1.000 4.0 Ox0 VIFx 42.6 135.0 st4 THEATER h 3309 135 93 1.000 7.0 Ox0 VIFx 58.2 155.0 sty THEATER -A h 3309 135 93 1.000 7.0 Ox0 VIFx 48.8 155.0 st5 WIC 2 c 27 1 1 1.000 4.0 Ox0 VIFx 16.0 115.0 sti Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st5 Peak AVF 320 234 1.000 725 9.0 0 x 0 VinlFlx st4 st4 Peak AVF 624 614 1.000 794 12.0 0 x 0. VinlFlx sti sti Peak AVF 800 800 1.000 748 14.0 0 x 0 VinlFlx ' wrightmoft® 2020-Oct-13 16:11:15 CWIeNI.e.Mire U +wryfnmp M Right -Suite@ Universal 2019 19.0.08 RSU08101 Page 1 ...\MONTANA TRANQUILITY LN REVISION 10 13 20:rup Calc = MJ8 Front Door faces: S Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb2 Ox 0 800 800 0 0 1 0 0 Ox 0 V IFx - wrightsoft® ,.,r.� o.e*••.•..�� r Right -Suite® Universal 201919.0.08 RSU08101 ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Calc = MJ8 Front Door faces: S 2020-Oct-13 16:11:15 Page 2 wrightsoft® Duct System Summary AHU 2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466.6796 Email: QUICKCALCSQAOL.COM Project Information For: THOMAS AND ELIZABETH MONTANA, PLM CONSTRUCTION TRANQUILITY BASE LANE, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 800 cfm 140 ft Job: Date: Oct 13, 2020 9y: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 800 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk FOYER C 2781 83 129 1.000 7.0 Ox 0 VIFx 12.5 115.0 st2 GREATRM c 2422 81 112 1.000 7.0 Ox0 VIFx 16.5 115.0 st3 GREAT RM-A c 2422 81 112 1.000 7.0 Ox 0 VIFx 20.3 115.0 st3 M BATH h 2240 88 67 1.000 6.0 Ox0 VIFx 11.8 115.0 st2 •TOILET h 709 28 22 1.000 5.0 Ox0 VIFx 23.4 115.0 st3 • WIC h 2155 85 61 1.000 6.0 Ox0 VIFx 9.9 115.0 st2 M WIC -A h 2155 .85 61 1.000 6.0 Ox0 VIFx 13.9 115.0 st2 MASTER BEDROOM h 3435 135 118 1.000 7.0 Ox 0 VIFx 25.2 115.0 st3 MASTER BED ROOM -A h 3435 135 118 1 1.000 7.0 Ox0 VIFx 16.5 115.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 341 317 1.000 772 9.0 0 x 0 VinlFlx st3 Peak AVF 459 483 1.000 615 12.0 0 x 0 VInIFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in). Stud/Joist Opening (in) Duct Matl Trunk rbi Ox 0 800 800 0 0 0 0 Ox 0 VIFx 1- Wr1�917tSOft® Right -Suite® Universal 2019 19.0.08 RSU08101 ...\MONTANA TRANQUILITY LN REVISION 10 13 20.rup Cale = MJ8 Front Door faces 2020-Oct-13 16:11:15 Page 3 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.