HomeMy WebLinkAboutAPPROVED FL17678_R7_AE_DRX15001.7 2020 FBC APENDIX B PAGE 1-8a CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 1 of 5 Page 1 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7TH EDITION (2020)
Manufacturer: DREXEL METALS, INC. Issued August 9, 2020
1234 Gardiner Lane
Louisville, KY 40213
(502) 716-7143
www.drexmet.com
Manufacturing: Drexel Metals Association of Regional Manufacturers (DM-ARM)
Quality Assurance: Architectural Testing, Inc., an Intertek Company (QUA1844)
SCOPE
Category: Roofing
Subcategory: Metal Roofing
Code Sections: 1504.3
Properties: Wind Resistance
REFERENCES
Entity Report No. Standard Year
Architectural Testing (TST1558) 56840.02-122-18 TAS 100 1995
Architectural Testing (TST1558) 58389.01-122-44 UL 580 2006
Architectural Testing (TST1558) 58459.01-122-44 UL 580 2006
Architectural Testing (TST1558) 58461.01-122-44 TAS 125 2003
Architectural Testing (TST1558) 82776.01-109-44 UL 580
UL 1897
2006
2012
Architectural Testing (TST1558) 82784.01-109-44 UL 580
UL 1897
2006
2012
Architectural Testing (TST1558) 83296.01-109-44 UL 580
UL 1897
2006
2012
Architectural Testing, Inc (an Intertek Company) (TST1527) H3245.01-450-18 TAS 125 2003
Architectural Testing, Inc (an Intertek Company) (TST1527) H9058.02-450-18 TAS 125 2003
Architectural Testing, Inc (an Intertek Company) (TST1527) H9058.01-450-18 TAS 125 2003
Architectural Testing, Inc (an Intertek Company) (TST1527) I3391.01-450-44 UL 580 2006
Force Engineering & Testing (TST5328) 178-0054T-12 UL 580
UL 1897
2006
2012
Force Engineering & Testing (TST5328) 178-0055T-12 UL 580
UL 1897
2006
2012
Hurricane Test Laboratory (TST1527) 0287-0209-07 TAS 125 2003
Hurricane Test Laboratory (TST1527) 0287-0308-07 TAS 125 2003
Hurricane Test Laboratory (TST1527) 0287-0311-07 TAS 125 2003
Hurricane Test Laboratory (TST1527) 0287-0313-07 TAS 125 2003
Hurricane Test Laboratory (TST1527) 0287-0512-07 TAS 125 2003
Hurricane Test Laboratory (TST1527) 0287-0706-07 TAS 125 2003
PRI Construction Materials Technologies (TST5878) VLS-005-02-01 ASTM B 117
TAS 110
2016
2000
PRI Construction Materials Technologies (TST5878) VLS-004-02-01 ASTM G 155
TAS 110
2013
2000
PRI Construction Materials Technologies (TST5878) DMC-004-02-01 TAS 125 2003
PRI Construction Materials Technologies (TST5878) DMC-005-02-01 TAS 125 2003
PRI Construction Materials Technologies (TST5878) DMC-006-02-01 TAS 125 2003
PRI Construction Materials Technologies (TST5878) DMC-007-02-01 TAS 100 1995
PRI Construction Materials Technologies (TST5878) DMC-008-02-01 TAS 100 1995
PRI Construction Materials Technologies (TST5878) DMC-009-02-01 TAS 100 1995
PRI Construction Materials Technologies (TST5878) DMC-014-02-01 TAS 125 2003
PRI Construction Materials Technologies (TST5878) DMC-016-02-01 TAS 100 1995
PRI Construction Materials Technologies (TST5878) DMC-017-02-01 Rev 1 UL 580
UL 1897
2006
2012
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 2 of 5 Page 2 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
Entity Report No. Standard Year
PRI Construction Materials Technologies (TST5878) DMC-018-02-01 UL 580
UL 1897
2006
2012
PRI Construction Materials Technologies (TST5878) DMC-024-02-01 UL 580
UL 1897
2006
2012
PRI Construction Materials Technologies (TST5878) DMC-033-02-01.1 UL 580
UL 1897
2006
2012
PRI Construction Materials Technologies (TST5878) DMC-037-02-01 UL 580
UL 1897
2006
2012
PRI Construction Materials Technologies (TST5878) DMC-037-02-02 UL 580
UL 1897
2006
2012
PRI Construction Materials Technologies (TST5878) DMC-038-02-01 UL 580
UL 1897
2006
2012
PRODUCT DESCRIPTION
DMC 100NS Profile: 1 in. snap lock seam; Max.16 in. coverage
Description: Non-structural, snap lock standing seam roof panel with integral perorated nail
strip
Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
DMC 150SL Profile: 1.5 in. snap lock seam; Max. 16 in. coverage
Description: Non-structural, snap lock standing seam roof panel
Material: Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 3 of 5 Page 3 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
DMC 150SS Profile: 1.5 in. mechanical seam; Max. 16 in. coverage
Description: Non-structural, mechanical lock standing seam roof panel
Material: Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 16 ksi; Shall
conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90; F y = min.
50 ksi; Shall conform with FBC Section 1507.4.3
Material: Min. 0.027 in. Zinc; Fy = min. 16 ksi; Shall conform with FBC Section 1507.4.3
DMC 175S Profile: 1.75 in. snap lock seam; Max. 18 in. coverage
Description: Non-structural, snap lock standing seam roof panel
Material: Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 24 ksi; Shall
conform with FBC Section 1507.4.3
Min. 0.040-inch Fluropon® coated ASTM B209 aluminum (Fy = min. 20 ksi); Shall
conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
DMC 200S Profile: 2 in. mechanical seam; Max. 16 in. coverage
Description: Non-structural, mechanical lock standing seam roof panel
Material: Min. 0.040 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 20 ksi; Shall
conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507.4.3
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 4 of 5 Page 4 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
DMC 450 Profile: 1.5 in. snap lock seam; Max. 16 in. coverage
Description: Non-structural, snap lock standing seam roof panel with concealed clip
Material: Min. 24 ga. ASTM A792 or ASTM A653; Fy = min. 50 ksi; Shall conform with FBC
Section 1507.4.3
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 24 ksi; Shall
conform with FBC Section 1507.4.3
DMC 5V Profile: 3/8 in. ribs; Min. 21 in., Max. 24 in. coverage
Description: Non-structural, through fastened roof panel
Material: Min. 26 ga. Fluropon® coated ASTM A792 or ASTM A653 G90 ; Fy = min. 50 ksi;
Shall conform with FBC Section 1507.4.3
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 23 ksi; Shall
conform with FBC Section 1507.4.3
DMC
Corrugated
Profile: 1/2 in. corrugation; 21 in. coverage
Description: Non-structural, through fastened roof panel
Material: Min. 26 ga. Fluropon® coated ASTM A792 or ASTM A653 G90 ; Fy = min. 40 ksi;
Shall conform with FBC Section 1507.4.3
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 19 ksi; Shall
conform with FBC Section 1507.4.3
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 5 of 5 Page 5 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
LIMITATIONS
1.Fire classification is not within the scope of this evaluation.
2.This report is not for use in the HVHZ.
3.The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4.Roof slope shall be in accordance with FBC Section 1507.4.2.
5.Reroofing shall be in accordance with FBC Section 1511.
6.Installation of the evaluated products shall comply with this report, the FBC and the manufacturer’s
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
7.All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7th Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer.
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1)APPENDIX A – Installation (12 pages)
2)APPENDIX B – Approved Roof Systems (8 pages)
3)APPENDIX C – Design Wind Loads (4 pages)
2020.08.09
15:00:49
-04'00'
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 1 of 12 Page 1 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
INSTALLATION
Note - Refer to the APPROVED ROOF SYSTEMS section of this report for specific installation details of a selected system.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Component Product Installation Detail
Fasteners
#9-15 HWH wood screw
with sealing washer
Shall penetrate through the sheathing a minimum 3/8 in. Must be corrosion
resistant in accordance with FBC section 1507.4.4.
#10-14 HWH wood screw
with sealing washer
#10-15 HWH wood
screws with dual threads
and sealing washer
#10-13 PH wood screw
#10-16 DP3 PH self-
drilling screw Shall penetrate through the top rib of the steel deck a minimum 3/4 in. Must be
corrosion resistant in accordance with FBC section 1507.4.4. #14-13 DP1 PH self-
drilling screw
Bearing Plates 18 ga. Bearing Plate
Clips
DMC 150SL Clip
24 ga. in-seam clip
24 ga. DMC 150SS Clip
24 ga. SS in-seam clip
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 2 of 12 Page 2 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
Component Product Installation Detail
Clips (Cont’d)
24 ga. DMC 150SS Fixed
Clip
24 ga. in-seam clip
26 ga. DMC 150SS Fixed
Clip
26 ga. in-seam clip
22 ga. DMC 150SS Clip
22 ga. SS in-seam clip
22 ga. DMC 150SS Fixed
Clip
22 ga. in-seam clip
DMC 150SS Butterfly
Clip
22 ga. base; 24 ga. butterfly in-seam clip
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 3 of 12 Page 3 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
Component Product Installation Detail
Clips (Cont’d)
DMC 150SS Continuous
Butterfly Clip
22 ga. base; 24 ga. butterfly in-seam clip
DMC 150SS Utility
Floating Clip
26 ga. in-seam clip
DMC 175S UL Clip
18 ga. in-seam clip
DMC 200S Clip
22 ga. SS in-seam clip
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 4 of 12 Page 4 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
Component Product Installation Detail
Clips (Cont’d)
DMC 200S Butterfly Clip
18 ga. base; 22 ga. butterfly in-seam clip; 4.5 in. length
DMC 200S Continuous
Butterfly Clip
18 ga. base; 22 ga. butterfly in-seam clip; 120 in. length; top slider 12 in. o.c.
DMC 450 Clip
24 ga. in-seam clip
DMC 450SS Clip
24 ga. SS in-seam clip
Sealants Bostik 70-05A Shall be applied in continuous beads along the seam Bostik Chem-Calk 915
Fastening Details
Nomenclature Attachment
DMC 100NS Standard
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 5 of 12 Page 5 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 100NS Enhanced
DMC 150SL Standard
DMC 150SS Continuous
Butterfly
DMC 150SS Butterfly
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 6 of 12 Page 6 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 150SS #14 Butterfly
DMC 150SS Fixed - 90
DMC 150SS #14 Fixed -
90
(2) #14-13 DP1, PH Screws per clip; Clip installed over 18 ga. bearing plate
DMC 150SS Standard (Al)
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 7 of 12 Page 7 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 150SS Fixed
Enhanced - 90
DMC 150SS Fixed
Enhanced - 180
DMC 150SS Enhanced (Al)
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 8 of 12 Page 8 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 150SS Zinc
DMC 175S #10 Standard
DMC 175S #10 Enhanced
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 9 of 12 Page 9 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 175S #14 Standard
DMC 200S Butterfly
DMC 200S Butterfly (Steel)
Use 18 ga. bearing plate over polyisocyanurate insulation
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 10 of 12 Page 10 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 200S Continuous
Butterfly (Steel)
Use 18 ga. bearing plate over polyisocyanurate insulation
DMC 200S Fixed
DMC 200S Fixed
Enhanced
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 11 of 12 Page 11 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 450 Standard
DMC 450SS Standard
DMC 5V Standard
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 12 of 12 Page 12 of 29
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for whi ch this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that a re not
specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX A
Fastening Details
Nomenclature Attachment
DMC 5V #10 Standard
DMC 5V Pan Fastening
DMC Corrugated
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 1 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX B
APPROVED ROOF SYSTEMS
The following notes shall be observed when using the assembly tables below.
1. Maximum Design Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1504.9.
2. Refer to LIMITATIONS and sections of this evaluation when using the table(s) below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on-center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system.
5. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy = min.40 ksi) Wide Rib Deck (Type WR)
conforming to ANSI/SDI-RD1.0 & FBC.
6. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span-Rated plywood
sheathing at maximum 24-inch span.
Roof System Numbers and Definitions
100NS-W# DMC 100NS over Wood Deck (New or Existing)
150SL-W# DMC 150SL over Wood Deck (New or Existing)
150SS-S# DMC 150SS over Steel Deck (New or Existing)
150SS-W# DMC 150SS over Wood Deck (New or Existing)
175S-S# DMC 175S over Steel Deck (New or Existing)
175S-W# DMC 175S over Wood Deck (new or Existing)
200S-S# DMC 200S over Steel Deck (New or Existing)
200S-W# DMC 200S over Wood Deck (New or Existing)
450-W# DMC 450 over Wood Deck (New or Existing)
5V-W# DMC 5V over Wood Deck (New or Existing)
COR-W# DMC Corrugated over Wood Deck (New or Existing)
Approved Systems for DMC 100NS over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
100NS-W1 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 100NS
Max. 16-inch wide DMC 100NS Standard attachment
with fastener spaced 10.5 in. o.c. -97.5
100NS-W2 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 100NS
Max. 16-inch wide DMC 100NS Standard attachment
with fasteners spaced 5.25 in. o.c. -120
100NS-W3 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 100NS
Max. 16-inch wide DMC 100NS Enhanced attachment
with fasteners spaced 5.25 in. o.c. -135
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 2 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX B
Approved Systems for DMC 150SL over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
150SL-W1 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 150SL
Max. 16-inch wide DMC 150SL Standard attachment
with clips spaced 16 in. o.c. -52.5
Approved Systems for DMC 150SS over Steel Deck (New or Existing)
System
No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
150SS-S1 Min. 22 ga.
Type B,
Grade 80 Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide DMC 150SS #14 Butterfly attachment
with clips spaced 36 in. o.c. -41.7
150SS-S2 Min. 22 ga.
Type B,
Grade 80 Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
Approved ASTM D
1970 underlayment 24 ga. DMC 150SS
Max. 16-inch wide DMC 150SS #14 Fixed - 90 attachment
with clips spaced 16 in. o.c. -71
150SS-S3
Min. 22 ga.
Type B,
Grade 80 Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide DMC 150SS #14 Butterfly attachment
with clips spaced 24 in. o.c. -92.4
150SS-S4
Min. 22 ga.
Type B,
Grade 80 Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide DMC 150SS #14 Butterfly attachment
with clips spaced 18 in. o.c. -117.8
150SS-S5
Min. 22 ga.
Type B,
Grade 80 Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide DMC 150SS #14 Butterfly attachment
with clips spaced 12 in. o.c. -143.1
150SS-S6
Min. 22 ga.
Type B,
Grade 80 Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide DMC 150SS #14 Butterfly attachment
with clips spaced 6 in. o.c. -168.5
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 3 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX B
Approved Systems for DMC 150SS over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf)
150SS-W1 Min. 15/32
CDX plywood
OPTIONAL
Versashield Solo
Approved ASTM D
1970 underlayment
0.027” (0.7mm) Zinc DMC
150SS
Max. 15.7-inch wide
180° seam
DMC150SS Zinc attachment
with DMC 150SS Utility Floating Clips
spaced 18 in. o.c.
-78.5
150SS-W2 Min. 15/32
CDX plywood
OPTIONAL
Versashield Solo
Approved ASTM D
1970 underlayment
0.027” (0.7mm) Zinc DMC
150SS
Max. 15.7-inch wide
180° seam
DMC150SS Zinc attachment
with DMC 150SS Utility Floating Clips
spaced 6 in. o.c.
-86
150SS-W3 Min. 15/32
CDX plywood
OPTIONAL
Versashield Solo
Approved ASTM D
1970 underlayment
0.027” (0.7mm) Zinc DMC
150SS
Max. 15.7-inch wide
180° seam
DMC150SS Zinc attachment
with 26 ga. DMC 150SS Fixed Clips spaced
18 in. o.c.
-86
150SS-W4 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 0.032” Al DMC 150SS
Max. 16-inch wide
180° seam
DMC 150SS Standard (Al) attachment
with clips spaced 16 in. o.c. -90
150SS-W5 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide
90° seam
DMC 150SS Fixed - 90 attachment
with clips spaced 16 in. o.c. -90
150SS-W6 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide
180° seam
DMC 150SS Butterfly attachment
with clips spaced 16 in. o.c. -99.25
150SS-W7 Min. 15/32
CDX plywood
OPTIONAL
Versashield Solo
Approved ASTM D
1970 underlayment
0.027” (0.7mm) Zinc DMC
150SS
Max. 15.7-inch wide
180° seam
DMC150SS Zinc attachment
with 26 ga. DMC 150SS Fixed Clips spaced
9 in. o.c.
-108.5
150SS-W8 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide
180° seam
DMC 150SS Continuous Butterfly
attachment with fasteners spaced 12 in. o.c. -114.25
150SS-W9 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide
Min. 90° seam
DMC 150SS Fixed Enhanced - 90
attachment
with clips spaced 12 in. o.c. -150
150SS-W10 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 150SS
Max. 16-inch wide
Min. 180° seam
DMC 150SS Fixed Enhanced - 180
attachment
with clips spaced 8 in. o.c. -165
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 4 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX B
Approved Systems for DMC 150SS over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP (psf)
150SS-W11 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 0.032” Al DMC 150SS
Max. 16-inch wide
180° seam
DMC 150SS Enhanced (Al) attachment
with clips spaced 8 in. o.c. -180
Approved Systems for DMC 175S over Steel Deck (New or Existing)
System
No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
175S-S1 Min. 22 ga.
Type B Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 24 ga. DMC 175S
Max. 18-inch wide DMC 175S #14 Standard attachment
with clips spaced 36 in. o.c. -60
175S-S2 Min. 22 ga.
Type B Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 0.040” Al DMC 175S
Max. 17.5-inch wide DMC 175S #14 Standard attachment
with clips spaced 18 in. o.c. -88
175S-S3 Min. 22 ga.
Type B Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 24 ga. DMC 175S
Max. 18-inch wide DMC 175S #14 Standard attachment
with clips spaced 6 in. o.c. -105
175S-S4 Min. 22 ga.
Type B Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 0.040” Al DMC 175S
Max. 17.5-inch wide DMC 175S #14 Standard attachment
with clips spaced 12 in. o.c. -129.25
Approved Systems for DMC 175S over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
175S-W1 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 0.032” Al DMC 175S
Max. 18-inch wide DMC 175S #10 Standard attachment
with clips spaced 24 in. o.c. -52.5
175S-W2 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 0.032” Al DMC 175S
Max. 18-inch wide DMC 175S #10 Standard attachment
with clips spaced 18 in. o.c. -59.4
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 5 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX B
Approved Systems for DMC 175S over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
175S-W3 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 0.032” Al DMC 175S
Max. 18-inch wide DMC 175S #10 Standard attachment
with clips spaced 12 in. o.c. -66.4
175S-W4 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 0.032” Al DMC 175S
Max. 18-inch wide DMC 175S #10 Standard attachment
with clips spaced 8 in. o.c. -71
175S-W5 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo Approved ASTM D 1970 underlayment 0.032” Al DMC 175S
Max. 18-inch wide DMC 175S #10 Enhanced attachment
with clips spaced 12 in. o.c. -71
175S-W6 Min. 15/32
CDX plywood -
ASTM D 226, Type II roofing felt attached per
1518.2.1 with nails and tin caps per 1517.5
followed by Metshield High-Temp
Underlayment self-adhered to felt
0.032” Al DMC 175S
Max. 18-inch wide
DMC 175S #10 Standard attachment
with clips spaced 24 in. o.c. -74.75
175S-W7 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 0.032” Al DMC 175S
Max. 14-inch wide DMC 175S #10 Standard attachment
with clips spaced 12 in. o.c. -82.5
175S-W8 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 24 ga. DMC 175S
Max. 18-inch wide DMC 175S #10 Standard attachment
with clips spaced 16 in. o.c. -84.25
175S-W9 Min. 19/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 24 ga. DMC 175S
Max. 16-inch wide DMC 175S #10 Standard attachment
with clips spaced 25 in. o.c. -97.5
175S-W10 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 0.040” Al DMC 175S
Max. 17.5-inch wide DMC 175S #10 Standard attachment
with clips spaced 18 in. o.c. -106.75
175S-W11 Min. 15/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 24 ga. DMC 175S
Max. 18-inch wide DMC 175S #10 Standard attachment
with clips spaced 8 in. o.c. -121.75
175S-W12 Min. 15/32
CDX plywood -
ASTM D 226, Type II roofing felt attached per
1518.2.1 with nails and tin caps per 1517.5
followed by Metshield High-Temp
Underlayment self-adhered to felt
0.032” Al DMC 175S
Max. 18-inch wide
DMC 175S #10 Standard attachment
with clips spaced 6 in. o.c. -131
175S-W13 Min. 19/32
CDX plywood
OPTIONAL
Versashield
Solo As required per FBC 24 ga. DMC 175S
Max. 16-inch wide DMC 175S #10 Standard attachment
with clips spaced 8 in. o.c. -135
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 6 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX B
Approved Systems for DMC 200S over Steel Deck (New or Existing)
System
No. Deck Fire Barrier Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
200S-S1 Min. 22 ga.
Type B Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 24 ga. DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Butterfly (Steel) attachment
with clips spaced 24 in. o.c. -88
200S-S2 Min. 22 ga.
Type B Steel As required None As required per FBC 24 ga. DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Butterfly (Steel) attachment
with clips spaced 24 in. o.c. -91.75
200S-S3 Min. 22 ga.
Type B Steel As required Min. 1 in. Approved
polyisocyanurate
insulation board
As required per FBC 24 ga. DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Continuous Butterfly (Steel)
attachment with clips spaced 12 in. o.c. -121.75
200S-S4 Min. 22 ga.
Type B Steel As required None As required per FBC 24 ga. DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Continuous Butterfly (Steel)
attachment with clips spaced 12 in. o.c. -151.75
Approved Systems for DMC 200S over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
200S-W1 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Butterfly attachment
with clips spaced 24 in. o.c. -67.5
200S-W2 Min. 15/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 0.040” Al DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Butterfly attachment
with clips spaced 24 in. o.c. -75
200S-W3 Min. 19/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 0.040” Al DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Fixed attachment
with clips spaced 16 in. o.c. -105
200S-W4 Min. 19/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 0.040” Al DMC 200S
Max. 16-inch wide
180° seam
DMC 200S Fixed Enhanced attachment
with clips spaced 8 in. o.c. -180
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 7 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX B
Approved Systems for DMC 450 over Wood Deck (New or Existing)
System
No. Deck Fire Barrier Underlayment Roof Panel Panel Attachment MDP
(psf)
450-W1 Min. 19/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 450
Max. 16-inch wide
DMC 450 Standard attachment
with clips spaced 24 in. o.c. -30
450-W2 Min. 15/32
CDX plywood
OPTIONAL
Versashield Solo As required per FBC 0.032” Al DMC 450
Max. 16-inch wide
DMC 450SS Standard attachment
with clips spaced 16 in. o.c. -45
450-W3 Min. 19/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 450
Max. 16-inch wide DMC 450 Standard attachment
with clips spaced 15.5 in. o.c. -67.5
450-W4 Min. 15/32
CDX plywood
OPTIONAL
Versashield Solo As required per FBC 0.032” Al DMC 450
Max. 16-inch wide
DMC 450SS Standard attachment
with clips spaced 6 in. o.c. -75
450-W5 Min. 19/32
CDX plywood OPTIONAL
Versashield Solo As required per FBC 24 ga. DMC 450
Max. 16-inch wide DMC 450 Standard attachment
with clips spaced 6 in. o.c. -82.5
Approved Systems for DMC 5V over Wood Deck (New or Existing)
System
No. Deck Fire Barrier/
Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
5V-W1 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation
ASTM D 226, Type II roofing felt attached per
1518.2.1 with nails and tin caps per 1517.5
followed by Metshield High-Temp
Underlayment self-adhered to felt
0.032” Al DMC 5V
Min. 21-inch to
Max. 24-inch
coverage
DMC 5V #10 Standard attachment
with #10-14 HWH wood screws with
sealing washers spaced 18 in. o.c.
-56
5V-W2 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC
26 ga. DMC 5V
Min. 21-inch to
Max. 24-inch
coverage
DMC 5V Standard attachment
with #9-15 HWH wood screws with
sealing washers spaced 16 in. o.c. -60
5V-W3 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation
ASTM D 226, Type II roofing felt attached per
1518.2.1 with nails and tin caps per 1517.5
followed by Metshield High-Temp
Underlayment self-adhered to felt
26 ga. DMC 5V
Min. 21-inch to
Max. 24-inch
coverage
DMC 5V #10 Standard attachment
with #10-14 HWH wood screws with
sealing washers spaced 24 in. o.c.
-71
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 8 of 8
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX B
Approved Systems for DMC 5V over Wood Deck (New or Existing)
System
No. Deck Fire Barrier/
Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
5V-W4 Min. 7/16 OSB
plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC
26 ga. DMC 5V
Min. 21-inch to
Max. 24-inch
coverage
DMC 5V Pan Fastening attachment
with #10-14 HWH wood screws with
sealing washers spaced 16 in. o.c.
-75
5V-W5 Min. 7/16 OSB
plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC
26 ga. DMC 5V
Min. 21-inch to
Max. 24-inch
coverage
DMC 5V Pan Fastening attachment
with #10-14 HWH wood screws with
sealing washers spaced 8 in. o.c.
-112.5
5V-W6 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC
26 ga. DMC 5V
Min. 21-inch to
Max. 24-inch
coverage
DMC 5V Standard attachment
with #9-15 HWH wood screws with
sealing washers spaced 8 in. o.c. -121.75
5V-W7 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation
ASTM D 226, Type II roofing felt attached per
1518.2.1 with nails and tin caps per 1517.5
followed by Metshield High-Temp
Underlayment self-adhered to felt
26 ga. DMC 5V or
0.032” Al DMC 5V
Min. 21-inch to
Max. 24-inch
coverage
DMC 5V #10 Standard attachment
with #10-14 HWH wood screws with
sealing washers spaced 6 in. o.c.
-206
Approved Systems for DMC Corrugated over Wood Deck (New or Existing)
System
No. Deck Fire Barrier/
Insulation Underlayment Roof Panel Panel Attachment MDP
(psf)
COR-W1 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC 0.032” Al DMC Corrugated
Max. 21-inch coverage
DMC 5V Corrugated attachment
with #10-15 HWH wood screws with dual threads
and sealing washer spaced 36 in. o.c. -60
COR-W2 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC 26 ga. DMC Corrugated
Max. 21-inch coverage
DMC 5V Corrugated attachment
with #10-15 HWH wood screws with dual threads
and sealing washer spaced 36 in. o.c.
-60
COR-W3 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation
As required per FBC 0.032” Al DMC Corrugated
Max. 21-inch coverage
DMC 5V Corrugated attachment
with #10-15 HWH wood screws with dual threads
and sealing washer spaced 12 in. o.c.
-135
COR-W4 Min. 15/32
CDX plywood
OPTIONAL
Approved fire barrier
or insulation As required per FBC 26 ga. DMC Corrugated
Max. 21-inch coverage
DMC 5V Corrugated attachment
with #10-15 HWH wood screws with dual threads
and sealing washer spaced 12 in. o.c. -150
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX C
DESIGN WIND LOADS
The following tables provide design wind loads for components and cladding in accordance with Section 1609 of the FBC and ASCE 7-16 under the following
provisions:
1. Wind speeds for risk category I, II, III, and IV buildings shall be as defined in Section 1609 of the FBC.
2. Exposure B, C, and D shall be as defined in section 1609 of the FBC.
3. Design wind load provided only for gable/hip roofs with roof slopes between 2:12 and 6.1:12
4. All calculations are based on an effective wind area of 10-ft2 or less.
5. Topographic factors such as escarpments or hills have been excluded from the analysis
6. Overhangs have been excluded from the analysis.
7. Wind directionality factor, Kd = 0.85
8. Vult is shown in the tables below. Design wind loads are calculated using Vasd = Vult√0.6 per 1609.3.1.
9. Zone 2 is inclusive of Zone 2e, Zone 2n, and Zone 2r
10. Zone 3 is inclusive of Zone 3e and Zone 3r
11. Projects with mean roof heights greater than 60-ft shall be evaluated by a licensed design professional
12. Zones 1, 2, and 3 shall be defined as shown below. Dimension “a” shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever
is smaller, but not less than either 4% of the least horizontal dimension or 3ft
Gable Hip
.
a a a
3 3 a
2 2 1
2 3
a 3
2
a
3
2
2 3
3
1 2
2 3
a a
a
a
a
3
3 2
2
1
1
2 2 1
a
2 2 1
3
3
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX C
Gable/Hip Roofs in Exposure B (Roof slope between 2:12 and 12:12)
Building Type Zone
Mean
Roof
Height (ft)
Basic Wind Speed (mph)
120 130 140 150 160 170 180 190 200
Enclosed/
Partially Open
1
20 -25.4 -29.8 -34.6 -39.7 -45.2 -51.0 -57.2 -63.7 -70.6
25 -27.5 -32.2 -37.4 -42.9 -48.8 -55.1 -61.8 -68.8 -76.3
30 -28.7 -33.7 -39.1 -44.8 -51.0 -57.6 -64.6 -71.9 -79.7
40 -31.2 -36.6 -42.4 -48.7 -55.4 -62.5 -70.1 -78.1 -86.5
50 -33.2 -39.0 -45.2 -51.9 -59.0 -66.6 -74.7 -83.2 -92.2
60 -34.8 -40.9 -47.4 -54.4 -61.9 -69.9 -78.4 -87.3 -96.8
2
20 -37.1 -43.5 -50.5 -57.9 -65.9 -74.4 -83.4 -92.9 -103.0
25 -40.1 -47.0 -54.5 -62.6 -71.2 -80.4 -90.1 -100.4 -111.3
30 -41.9 -49.1 -57.0 -65.4 -74.4 -84.0 -94.2 -104.9 -116.3
40 -45.4 -53.3 -61.9 -71.0 -80.8 -91.2 -102.2 -113.9 -126.2
50 -48.4 -56.8 -65.9 -75.7 -86.1 -97.2 -109.0 -121.4 -134.5
60 -30.0 -35.3 -40.9 -46.9 -53.4 -60.3 -67.6 -75.3 -83.5
3
20 -44.1 -51.7 -60.0 -68.8 -78.3 -88.4 -99.1 -110.5 -122.4
25 -47.6 -55.9 -64.8 -74.4 -84.7 -95.6 -107.1 -119.4 -132.3
30 -49.8 -58.4 -67.7 -77.7 -88.4 -99.8 -111.9 -124.7 -138.2
40 -54.0 -63.4 -73.5 -84.4 -96.0 -108.4 -121.5 -135.4 -150.0
50 -57.6 -67.6 -78.4 -90.0 -102.3 -115.5 -129.5 -144.3 -159.9
60 -60.4 -70.9 -82.2 -94.4 -107.4 -121.2 -135.9 -151.4 -167.8
Partially
Enclosed
1
20 -29.7 -34.9 -40.5 -46.5 -52.8 -59.7 -66.9 -74.5 -82.6
25 -32.1 -37.7 -43.7 -50.2 -57.1 -64.5 -72.3 -80.5 -89.2
30 -33.6 -39.4 -45.7 -52.4 -59.7 -67.4 -75.5 -84.1 -93.2
40 -36.4 -42.8 -49.6 -56.9 -64.8 -73.1 -82.0 -91.3 -101.2
50 -38.8 -45.6 -52.9 -60.7 -69.0 -77.9 -87.4 -97.4 -107.9
60 -40.8 -47.8 -55.5 -63.7 -72.4 -81.8 -91.7 -102.2 -113.2
2
20 -41.4 -48.6 -56.3 -64.7 -73.6 -83.1 -93.1 -103.7 -115.0
25 -44.7 -52.5 -60.9 -69.9 -79.5 -89.8 -100.6 -112.1 -124.2
30 -46.7 -54.8 -63.6 -73.0 -83.1 -93.8 -105.1 -117.1 -129.8
40 -50.7 -59.5 -69.0 -79.3 -90.2 -101.8 -114.1 -127.2 -140.9
50 -54.1 -63.4 -73.6 -84.5 -96.1 -108.5 -121.6 -135.5 -150.2
60 -56.7 -66.6 -77.2 -88.6 -100.9 -113.9 -127.6 -142.2 -157.6
3
20 -48.4 -56.8 -65.8 -75.6 -86.0 -97.1 -108.8 -121.3 -134.4
25 -52.3 -61.4 -71.2 -81.7 -92.9 -104.9 -117.6 -131.1 -145.2
30 -54.6 -64.1 -74.3 -85.3 -97.1 -109.6 -122.9 -136.9 -151.7
40 -59.3 -69.6 -80.7 -92.7 -105.4 -119.0 -133.4 -148.7 -164.7
50 -63.2 -74.2 -86.0 -98.8 -112.4 -126.8 -142.2 -158.4 -175.6
60 -66.3 -77.8 -90.3 -103.6 -117.9 -133.1 -149.2 -166.3 -184.2
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX C
Gable/Hip Roofs in Exposure C (Roof slope between 2:12 and 12:12)
Building Type Zone
Mean
Roof
Height (ft)
Basic Wind Speed (mph)
120 130 140 150 160 170 180 190 200
Enclosed/
Partially Open
1
20 -36.9 -43.3 -50.2 -57.6 -65.6 -74.0 -83.0 -92.5 -102.5
25 -38.5 -45.2 -52.4 -60.2 -68.5 -77.3 -86.7 -96.6 -107.0
30 -40.2 -47.1 -54.7 -62.8 -71.4 -80.6 -90.4 -100.7 -111.6
40 -42.6 -50.0 -58.0 -66.6 -75.8 -85.6 -95.9 -106.9 -118.4
50 -44.7 -52.4 -60.8 -69.8 -79.4 -89.7 -100.5 -112.0 -124.1
60 -46.3 -54.4 -63.0 -72.4 -82.3 -93.0 -104.2 -116.1 -128.7
2
20 -53.8 -63.2 -73.2 -84.1 -95.7 -108.0 -121.1 -134.9 -149.5
25 -56.2 -66.0 -76.5 -87.8 -99.9 -112.8 -126.5 -140.9 -156.1
30 -58.6 -68.8 -79.8 -91.6 -104.2 -117.6 -131.8 -146.9 -162.8
40 -62.2 -73.0 -84.6 -97.2 -110.5 -124.8 -139.9 -155.9 -172.7
50 -65.2 -76.5 -88.7 -101.8 -115.9 -130.8 -146.6 -163.4 -181.0
60 -67.6 -79.3 -92.0 -105.6 -120.1 -135.6 -152.0 -169.4 -187.7
3
20 -64.0 -75.1 -87.1 -99.9 -113.7 -128.4 -143.9 -160.3 -177.7
25 -66.8 -78.4 -90.9 -104.4 -118.8 -134.1 -150.3 -167.5 -185.6
30 -69.7 -81.7 -94.8 -108.8 -123.8 -139.8 -156.7 -174.6 -193.5
40 -73.9 -86.7 -100.6 -115.5 -131.4 -148.3 -166.3 -185.3 -205.3
50 -77.5 -90.9 -105.4 -121.0 -137.7 -155.5 -174.3 -194.2 -215.2
60 -80.3 -94.3 -109.3 -125.5 -142.8 -161.2 -180.7 -201.3 -223.1
Partially
Enclosed
1
20 -43.2 -50.6 -58.7 -67.4 -76.7 -86.6 -97.1 -108.2 -119.9
25 -45.1 -52.9 -61.3 -70.4 -80.1 -90.4 -101.4 -113.0 -125.2
30 -47.0 -55.1 -64.0 -73.4 -83.5 -94.3 -105.7 -117.8 -130.5
40 -49.9 -58.5 -67.9 -77.9 -88.6 -100.1 -112.2 -125.0 -138.5
50 -52.3 -61.3 -71.1 -81.7 -92.9 -104.9 -117.6 -131.0 -145.2
60 -54.2 -63.6 -73.7 -84.7 -96.3 -108.7 -121.9 -135.8 -150.5
2
20 -60.1 -70.5 -81.8 -93.9 -106.8 -120.6 -135.2 -150.6 -166.9
25 -62.7 -73.6 -85.4 -98.0 -111.5 -125.9 -141.2 -157.3 -174.3
30 -65.4 -76.8 -89.0 -102.2 -116.3 -131.3 -147.2 -164.0 -181.7
40 -69.4 -81.5 -94.5 -108.5 -123.4 -139.3 -156.2 -174.0 -192.8
50 -72.8 -85.4 -99.0 -113.7 -129.3 -146.0 -163.7 -182.4 -202.1
60 -75.4 -88.5 -102.7 -117.8 -134.1 -151.4 -169.7 -189.1 -209.5
3
20 -70.2 -82.4 -95.6 -109.7 -124.8 -140.9 -158.0 -176.0 -195.1
25 -73.3 -86.1 -99.8 -114.6 -130.4 -147.2 -165.0 -183.9 -203.7
30 -76.5 -89.7 -104.1 -119.5 -135.9 -153.5 -172.0 -191.7 -212.4
40 -81.1 -95.2 -110.5 -126.8 -144.3 -162.9 -182.6 -203.4 -225.4
50 -85.0 -99.8 -115.8 -132.9 -151.2 -170.7 -191.4 -213.2 -236.2
60 -88.2 -103.5 -120.0 -137.8 -156.7 -177.0 -198.4 -221.0 -244.9
A CREEK
Technical Services, LLC
DRX15001.7 FL17678-R7 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is v alid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.
DREXEL METALS, INC.
Metal Roofing
APPENDIX C
Gable/Hip Roofs in Exposure D (Roof slope between 2:12 and 12:12)
Building Type Zone
Mean
Roof
Height (ft)
Basic Wind Speed (mph)
120 130 140 150 160 170 180 190 200
Enclosed/
Partially Open
1
20 -44.3 -52.0 -60.3 -69.2 -78.7 -88.8 -99.6 -111.0 -123.0
25 -45.9 -53.9 -62.5 -71.7 -81.6 -92.1 -103.3 -115.1 -127.5
30 -47.5 -55.8 -64.7 -74.3 -84.5 -95.4 -107.0 -119.2 -132.1
40 -50.0 -58.7 -68.1 -78.1 -88.9 -100.4 -112.5 -125.4 -138.9
50 -52.1 -61.1 -70.9 -81.3 -92.5 -104.5 -117.1 -130.5 -144.6
60 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.1
2
20 -64.6 -75.8 -87.9 -100.9 -114.8 -129.6 -145.3 -161.9 -179.4
25 -67.0 -78.6 -91.1 -104.6 -119.0 -134.4 -150.7 -167.9 -186.0
30 -69.4 -81.4 -94.4 -108.4 -123.3 -139.2 -156.0 -173.9 -192.6
40 -72.9 -85.6 -99.3 -114.0 -129.7 -146.4 -164.1 -182.9 -202.6
50 -75.9 -89.1 -103.3 -118.6 -135.0 -152.4 -170.8 -190.4 -210.9
60 -78.3 -91.9 -106.6 -122.4 -139.2 -157.2 -176.2 -196.3 -217.6
3
20 -76.8 -90.1 -104.5 -119.9 -136.5 -154.0 -172.7 -192.4 -213.2
25 -79.6 -93.4 -108.3 -124.4 -141.5 -159.7 -179.1 -199.5 -221.1
30 -82.4 -96.8 -112.2 -128.8 -146.6 -165.4 -185.5 -206.7 -229.0
40 -86.7 -101.8 -118.0 -135.5 -154.1 -174.0 -195.1 -217.4 -240.8
50 -90.3 -105.9 -122.8 -141.0 -160.5 -181.1 -203.1 -226.3 -250.7
60 -93.1 -109.3 -126.7 -145.5 -165.5 -186.8 -209.5 -233.4 -258.6
Partially
Enclosed
1
20 -51.8 -60.8 -70.5 -80.9 -92.1 -103.9 -116.5 -129.8 -143.8
25 -53.7 -63.0 -73.1 -83.9 -95.5 -107.8 -120.8 -134.6 -149.2
30 -55.6 -65.3 -75.7 -86.9 -98.9 -111.6 -125.1 -139.4 -154.5
40 -58.5 -68.7 -79.6 -91.4 -104.0 -117.4 -131.6 -146.6 -162.5
50 -60.9 -71.5 -82.9 -95.1 -108.2 -122.2 -137.0 -152.6 -169.1
60 -62.8 -73.7 -85.5 -98.1 -111.7 -126.0 -141.3 -157.5 -174.5
2
20 -72.1 -84.6 -98.1 -112.6 -128.2 -144.7 -162.2 -180.7 -200.2
25 -74.8 -87.7 -101.7 -116.8 -132.9 -150.0 -168.2 -187.4 -207.6
30 -77.4 -90.9 -105.4 -121.0 -137.6 -155.4 -174.2 -194.1 -215.1
40 -81.4 -95.6 -110.8 -127.2 -144.8 -163.4 -183.2 -204.1 -226.2
50 -84.8 -99.5 -115.4 -132.4 -150.7 -170.1 -190.7 -212.5 -235.5
60 -87.4 -102.6 -119.0 -136.6 -155.4 -175.5 -196.7 -219.2 -242.9
3
20 -84.3 -98.9 -114.7 -131.7 -149.8 -169.1 -189.6 -211.3 -234.1
25 -87.4 -102.6 -118.9 -136.5 -155.4 -175.4 -196.6 -219.1 -242.7
30 -90.5 -106.2 -123.2 -141.4 -160.9 -181.6 -203.6 -226.9 -251.4
40 -95.2 -111.7 -129.6 -148.7 -169.2 -191.0 -214.2 -238.6 -264.4
50 -99.1 -116.3 -134.9 -154.8 -176.2 -198.9 -223.0 -248.4 -275.2
60 -102.2 -120.0 -139.1 -159.7 -181.7 -205.1 -230.0 -256.2 -283.9