Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENT 4/14/2021 Florida Building Code Online BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts I Publicatt0. Contact Us II BCIs Slte Map Unks'I Search F rich - k ` P.roduct Approval_ USER Pu@Gc,U" i�issrru' Product Approval Menu>Product or ARollo 9n Search>Application List Search Criteria Refine Search, Code Version 2020 FL# ALL Application Type ALL Product Manufacturer Soprema,Inc.(Canada) Category ALL Subcategory ALL j Application Status ALL Compliance Method ALL Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL Product Model,Number or Name ALL Product Description ALL Approved for use in HVHZ ALL Approved for use outside HVHZ ALL iImpact Resistant ALL Design Pressure ALL Other ALL Search Results- llcatlons _ F n= Manufacturer Validated ev Status FL2569-1121 Revision Soprema,Inc.(Canada) ;John W.Knezevich,PE Approved History Category:Roofing .(954)772-6224 Subcategory:Underlayments '•Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary." - CentaR Us::2601 Blair Stone Road,Tallahassee FL 32390 ph9ne:-850-487-1824 The State of Florida Is an AA/EEO employer.Cooyrlght 2007-2013 State of Florida.::Privacy Statement::Aocessibllity statement::Refund Statement Under Florida law,emall addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic i mall to this entity.Instead,contact the office by phone or by traditional mall.if you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida statutes,effective October 1,2012,limnsees'llcensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However emall addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public To determine If you are a licensee under Chapter 455,F.S.,please dick b_qM. Product ApIprovpl.Aca ptd:, Credit Card Safe ;i �I htto�://www.floridabuilding.orgiprfpr_appjst.aspx 1/1 �, rY1eC�gSa� I . MEMO etc. I Certificate of Authorization#32455 353 Christian Street,Unit#13 Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION ••R Soprema,Inc. Evaluation Report S18010.06.09-1119 2640 rue Haggerty FL2569-1121 Drummondville,Quebec J2C 5P8 Canada Date of Issuance:06/15/2009 (819)478-2400 Revision 19:12/16/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, ( P.E.for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7ei Edition(2020)Florida Building Code sections noted herein. r_ ,.DEscrttPTloN:.;Soprema,Roof Underli yments LABELING•-Labelin shall be'in accordance`with the re quirements of the Accredited Quality� g_ q ' ty Assurance Agency noted !; herein and FBC 1507.1.1. j CONTINUED COMPLIANCE:This Evaluation Report is valid until such time asthe named product(s)changes,the referenced Quality Assurance or production facility location(s)changes,or Code provisions that relate to the product(s)change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Florida Product Approval Number(FL#) preceded by the words"NEMO I etc. Evaluated" may be displayed In advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or Its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 9. jPrepared by.- Robert '�'�taTA79''?;.Tm; The facsimile seal appearing was authorized by Robert J.M.Nieminen,P.E. _'.y��.:,.dI�Q..:_�,. Florida Registration No.59166,Florida DCAANE1983 �s�i�;aa%:E•- Nieminen,P.E.on 12/16/2020.This does not serve as 9 °���M•••�••'q••�, an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved In the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC,LLC i 1 !I ONEMOJetc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: U nderlayment Compliance Statement: Soprema Roof Underlayments,as produced by Soprema,have demonstrated compliance with the following sections of the 7eh Edition(2020)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS' Section Property Standard Year 1504.3.1 Wind resistance FM4474 2011 1504.3.1 Wind resistance UL 1897 2015 1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015 /R905.1.1,R905.2.8.2 1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018 1507.11.2/R905.11.2 Material standard ASTM D6163 2015 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Ent' Examination Reference Date ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD(TST6049) ASTM D1970/TAS 110(QC) S31370.03.10-1-R1 04/07/2010 ERD(TST6049) FRSA/TRI 04-12(OH) S11150.05.09-112 10/05/2010 ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011 ERD(TST6049) ASTM D1970(MS) S37210.12.11 22/01/2011 ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013 ERD(TST6049) FRSA/TRI 04-12(MS) S43530.02.14-1-R1 02/21/2014 ERD(TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014 ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014 ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014 ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014 ERD(TST6049) ASTM D1970(OH) S40540.10.14 10/31/2014 ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015 ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015 ERD(TST6049) Wind Resistance SOPC-SC14045.0S.17-R1 06/07/2017 M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018 ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017 NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018 NEMO(TST6049) Wind Resistance 4-SOPC-18-0D3.08.18 08/27/2018 NEMO(TST6049) ASTM D4798/D1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019 NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020 NEMO(TST6049) Peel adhesion(existing underlayments) 4J-SOPC-I9-SSUDL-04.A 03/12/2020 NEMO(TST6049) Peel adhesion(existing underlayments) 41-SOPC-20-SSUDL-01 12/16/2020 PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013 Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL,LLC(QUA9625) Quality Control MLA File No.R16814 12/10/2015 UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019 UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020 UL,LLC(QUA9625) Quality Control Florida BCIS Current NEMO ETC,LLC Evaluation Report S38010.06.09-1119 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1121 soprema Roof Underlayments Revision 19:12/15/2020 Page 2 of 9 *._. NEM0 etc. 4. PRODUCT DESCRIPTION: Material Product . Plant(s) Descrlptlon Standard - -= - - 4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyesterfabric FRSA/TRI 09-28 surfaced,SBS modified bitumen roof underlayment 4.2 Tri-Built S/A HTTU ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric Underlayment FRSA/TRI 09-18 surfaced,SBS modified bitumen roof underlayment 4.3 Lastobond Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available in two widths;36 and 45 inch 4.4 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC 'self-adhering,woven polyethylene surfaced,SBS 40 modified bitumen roof underlayment 4.5 Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment _ 4.6 Lastobond Pro HT-N ASTM D197o Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified bitumen roof underlayment available in two widths;36 and 45 inch 4.7 Lastobond Pro HT-S ASTM D1970 Drummondville,CSC self-adhering,woven polyethylene surfaced,high I temperature,SBS modified bitumen roof underlayment 4.8 EnviroShield ASTM D1976 Drummondville,QC self-adhering woven polyethylene surfaced,high temperature,SBS modified bitumen roof underlayment 4.9 Lastobond 195 ASTM D1970 Gulfport,M5 self-adhering,glass-mat reinforced,sand- Wadsworth,OH surfaced,SBS modified bitumen roof underlayment 4.10 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand- Protection Sheet Wadsworth,OH surfaced,SBS modified bitumen roof i underlayment 4.11 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- Guifport,MS surfaced,SBS modified bitumen roof Wadsworth,OH underlayment 4.12 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film- HT Wadsworth,OH surfaced,SBS modified bitumen roof underlayment 4.13 Tri-Built Smooth HTS/A ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film- Underlayment Wadsworth,OH surfaced,SBS modified bitumen roof underlayment 4.14 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film- Smooth Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof _ underlayment 4.15 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- Gulfport,MS surfaced,SBS modified bitumen roof Wadsworth,OH underlayment 4.16 TRI-BUILT Sand-R SA ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- Shingle Underlayment Gulfport,MS surfaced,SBS modified bitumen roof Wadsworth,OH underlayment I �I NEMO ETC,U.0 Evaluation Report S38010.06.09-R19 Certificate ofAuthoritation#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21 Soprema Roof Underlayments Revision 19:12/1S/2020 Page 3 of 9 I I I 17NEMOJetc.., Material Product Standard Plant(s) Description 4.17 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- Eave&Valley Protector Gulfport,MS surfaced,SBS modified bitumen roof Wadsworth,OH underlayment 4.18 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- WATER DEFENDER Gulfport,MS surfaced,SBS modified bitumen roof Wadsworth,OH underlayment 4.19 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand- Gulfport,MS surfaced,SBS modified bitumen roof Wadsworth,OH underlayment 4.20 Colphene FR GR ASTM D6163 Gulfport,MS self-adhering,fiberglass reinforced,granule- Wadsworth,OH surfaced,SB5 modified bitumen roof underlayment LIMITATIONS:S. 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report Is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 150S for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FBCSection: 15072 1507.3 1507.4&15075 1507.7 1507.8&1507.9 Asphalt pay and concrete Tile Metal. Slate or Underla ent Mechanical Adhesive- Slate-Type Wood Shakes or Shingles Attach Set Panels Shingles Shingles Shingles Yes Lastobond TU HT,Tri-Built S/A HT TU Yes Yes Yes Yes Yes Yes polntstrlps,1507.1.1.3/ Underlayment See 5.6.1 R905.LL31 Yes Lastobond Shield,Pro HT-N,RESISTO SA SMOOTH PLY 40 Yes No No No No Yes point sR905.1.1.3) .3/ R905.1.1.3) Yes Lastobond Shield HT,Pro HT-S Yes No No Yes Yes Yes point strip5,1507.1.1.3/ R905.L1.3) Yes EnviroShield Yes No No Yes Yes Yes pant strip5,1507.1.1.3/ R905.1.L3) Yes Lastobond Eaves Protection Sheet, Yes No No No No Yes pant strips,1507.1.3.31 Lastobond 195 R905.S.L3j NEMO ETC,LLC Evaluation Report S18010.06.09-1139 24 5 7-EDITION 2020 FBC NON-HVHZ EVALUATION FL2569-R21 Certificate o Authorization tl3 5 1 } Soprema Roof Underlayments Revision 19:12/15/2020 Page 4 of 9 i MEMO etc. TABLE 1: ROOF COVER OPTIONS FBCSecYhna, _-'=7.2 °15079 15074&25075 - 15077 1S&..8Ai507.9 -- Wood Shakes or Mechanital Adhes(ve•••I Asphalt Clay and concrete Tile __ Metal Slate or Underla ent = Shingles Panels F 1shingles. 'Slate-Type Shingles Attach set' shingles Lastobond ECU,RESISTo LB1236,Till- BUILT Sand-R SA Shingle Underlayment, Yes Grip-R(te Eave&Valley Protector, Yes No No No No Yes point strips,1507.1.1.3/ TopShield ICE&WATER DEFENDER, RWS.U.3) RESISTO LB1244 Lastobond Smooth Seal HT,Tri-Built Yes Smooth HT S/A Underlayment,Grip-Rite Yes No No Yes i Yes Yes point subs.1507.1.1.3/ Smooth Seal HT Rsos.1.131 Yes ColpheneFRGR Yes Yes No No No Yes point strips,ssoz1.13/ R905.1.1.3) 5.6.1 Adhesive-set the is limited to use of the following Approved underlayment/tile-adhesive combinations. TABLE 1A:ALLOWABLE TILE ADHESIVE UNDER_LAYMENT COMBINAiiONSi - Underiayment Adhesive Florida Product Approvals Lastobond TU HT,Tri-Built S/A Dupont`Tile Bondm Roof Tile Adhesive" FL22525 _ HT TU Underlayment ICP Adhesives and Sealants"Polyset®AH-160" _FL6332 5.7 Allowable.Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates(designed to meet wind loads for project) Underlayment Application,; ' .' - _ Type. Primer Material(s) I Lastobond Shield,Lastobond Pra (Optional)ASTM HT-N,RESISTO SA SMOOTH PLY Deck/ D41,Elastocol Stick, plywood,OSB or Southern Yellow Pine 40,Lastobond Shield HT, sheathing Elastocol Stick Zero ($YP) Lastobond Pro HT-S, ASTM D41 structural concrete EnviroShield,Lastobond TU HT, Tri-Built S/A HT TU Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum- Underlayment,Lastobond Eaves Stick Zero Fiber Roof Board Protection Sheet,Lastobond 195, self- Lastobond ECO,RESISTO LB1236, TRI-BUILT Sand-R SA Shingle adhering I Underlayment,Grip-Rite Eave& Valley Protector,TopShield ICE& Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra- WATER DEFENDER,RESISTO Stick Zero G LB1244,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A Underlayment or Grip-Rite Smooth Seal HT Deck/ (Optional)ASTM D41 plywood sheathing self- ASTM D41 structural concrete Colphene FIR GR (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum- adhering Insulation Stick Zero Fiber Roof Board Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra- Stick Zero G 1 Refer to The Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLC Evaluation Report S18010.06.09-Ri9 Certificate of Authorisation#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21 Soprema Roof Underlayments Revision 19:12115/2020 Page 5 of 9 lip 1' WhAol etc. f TABLE 2- SUBsTRATE OPTiohs FOR ADHERED UNDERLAYMENTS Substrates(designed to meet wind load`s for project) Underlayment Application - Type Primer - _- Material(s) Lastobond TU HT,Tri-Built S/A HT 'TU Underlayment,RESISTO LB1236,TRI-BUILT Sand-R SA 6 Existing sand-surfaced,glass-fiber surfaced, self- Existing RESISTO EXTERIOR I Shingle Underlayment,Grip-Rite adhering substrate PRIMER mineral-surfaced or film-surfaced roof Eave&Valley Protector or 1 underlayment' TopShield ICE&WATER DEFENDER "Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT,Tri-Built S/A HT TU Underlayment,RESiSTO LB1236,TRi-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE& WATER DEFENDER self-adhering underlayments,contact RESISTO technical support. 5.7.1 Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. 5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB priorto installation of the self-adhering underlayment 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions,but—for mechanically attached base sheets-not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A, Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein(for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the critical(highest)design pressure determined in accordance with FBC 2609 or FBC Residential Chapter 3. #1 Maximum Desikri Pressure=-45.0 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT,Tri-Built S/A HTTU Underlayment,self-adhered. #2 Maximum Design Pressure=-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol Stick Zero Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered. NEMO ETC,LLC Evaluation Report S18010.06.09-R19 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21 Soprema Roof Underlayments Revision 29:12/15/2020 Page 6 of 9 I 't NEMo,,16tc.. #3 .Maximum Deslsn Pressure=-120.0 asf: Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer. (Optional)RESISTO EXTERIOR PRIMER j Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered. Underlayment: Lastobond TU HT,Tri-Built S/A HTTU Underlayment,self-adhered. #4 Maximum Design Pressure=-150.0 usf: Deck: Min.15/32-inch APA-rated BCX plywood(may be Installed C-side up)to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)RESISTO'EXTERIOR PRIMER Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered. #5 All other direct-deck, adhered underlayment systems beneath file roof systems carry a Maximum Design Pressure of-45 psf. 5.8.3.2 Mechanically-Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #6 Maximum Des_ien_Pressure=-60.0 W. beck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6- inch o.c.at the 4-inch laps and 6-Inch o.c.in three(3),equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered 5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings,underlayment attachment shall be in accordance with the manufacturer's Installation instructions and attachment of the insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product Approval. 5.9 Exposure Limitations: TABLE.3 El(POSURE WiTATioNS Underlayment Prepared Roof Cover ' Maidmum Installation Type Exposure(days) Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,RESISTO LB1236,TRI- Mechanically BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector,TopShleld ICE 30 &WATER DEFENDER or RESISTO LB1244 attached Lastobond TU HT,Tri-Built S/A HT TU Underlayment Adhesive-set tile roof 30 system Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Mechanically Lastobond Pro HT-S,EnviroShield,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A attached 90 Underlayment or Grip-Rite Smooth Seal HT Lastobond TU HT,Tri-Built S/A HT TU Underlayment or Colphene FR GR Mechanically 180 attached I� NEMO ETC,LLC Evaluation Report S18010.06A&R19 Certificate of Authorization#32455 7-EDITION 12020)FBC NON-HVHZ EVALUATION F1.2569-1121 Soprema Roof Underlayments Revision 19.32/15/2020 Page 7 of 9 it i i NFM.o 1 etc: 5.10 Tile Sliapa`s_a Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4:TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS. _ Underlayment Tile Profile Staging Method Maximum Slope Flat Max.30-tile stack 6.12 Lugged Max.10-tile stack 5:12 Max.10-tile stack(bottom 2-tile stack shall be inverted, 6:12 followed by 8 tiles high on slope,as shown below) Lastobond TU HT,Tri -- Built S/A HT TU Underlayment Lugged Colphene FR GR Flat Max.10-tile stack 5:12 Lugged Max.SO-tile stack 6:12 6. INSTALLATION: 6.1 Soprema Roof Uriderlayments shall be installed in accordance with Soprema published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application,and prime the substrate(if applicable). 6.2.1 Installation of RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE&WATER DEFENDER self-adhering underlayment in a reroof(tear-off)application atop an existing underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE &WATER DEFENDER self-adhering underlayments,contact RESISTO technical support. 6.3 Lastobond TU HT, Tri-Built S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield,Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A Underlayment,Grip-Rite Smooth Seal HT, RESISTO L61236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley Protector,TopShield ICE&WATER DEFENDER,RESISTO L61244 or Colphene FR GR: 6.3.1 Non-Tile Applications: Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type 11 felt the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. MEMO ETC,LLC Evaluation Report S38010.06.09-R39 Certificate a/Authorizatton#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21 Soprema Roof Underlayments Revision 19:12/15/2020 Page 8 of 9 INEnno etc. 6.3.2 Tile Applications: Limited to Lastobond TU HT,Tri-Built S/A HTTU Underlayment or Colphene FIR GR. Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida High .Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation Instructions. Refer to Section S.8.3 herein for attachment limitations. Refer to Table 4 herein for the staging limitations. I' 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. a. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G10r3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: ji UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com -END OF EVALUATION REPORT- 'I I I i I I I i i� i MEMO ETC,LLC Evaluation Report S18010.06.09-1119 Certificate ofAuthorization#32455 7-EDITION(2020)FBC NON•HVHZ EVALUATION FL2569-1121 Soprenta Roof Underlayments Revision 19:12/15/2020 Page 9 of 9