HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENT 4/14/2021 Florida Building Code Online
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts I Publicatt0. Contact Us II BCIs Slte Map Unks'I Search
F rich -
k ` P.roduct Approval_
USER Pu@Gc,U"
i�issrru'
Product Approval Menu>Product or ARollo 9n Search>Application List
Search Criteria Refine Search,
Code Version 2020 FL# ALL
Application Type ALL Product Manufacturer Soprema,Inc.(Canada)
Category ALL Subcategory ALL
j Application Status ALL Compliance Method ALL
Quality Assurance Entity ALL Quality Assurance Entity Contract Expired ALL
Product Model,Number or Name ALL Product Description ALL
Approved for use in HVHZ ALL Approved for use outside HVHZ ALL
iImpact Resistant ALL Design Pressure ALL
Other ALL
Search Results- llcatlons _
F n= Manufacturer Validated ev Status
FL2569-1121 Revision Soprema,Inc.(Canada) ;John W.Knezevich,PE Approved
History Category:Roofing .(954)772-6224
Subcategory:Underlayments
'•Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary." -
CentaR Us::2601 Blair Stone Road,Tallahassee FL 32390 ph9ne:-850-487-1824
The State of Florida Is an AA/EEO employer.Cooyrlght 2007-2013 State of Florida.::Privacy Statement::Aocessibllity statement::Refund Statement
Under Florida law,emall addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
i mall to this entity.Instead,contact the office by phone or by traditional mall.if you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida statutes,effective October 1,2012,limnsees'llcensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails
provided may be used for official communication with the licensee.However emall addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public To determine If you are a licensee under Chapter 455,F.S.,please dick b_qM.
Product ApIprovpl.Aca ptd:,
Credit Card
Safe
;i
�I
htto�://www.floridabuilding.orgiprfpr_appjst.aspx 1/1
�, rY1eC�gSa�
I .
MEMO etc.
I
Certificate of Authorization#32455
353 Christian Street,Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION ••R
Soprema,Inc. Evaluation Report S18010.06.09-1119
2640 rue Haggerty FL2569-1121
Drummondville,Quebec J2C 5P8 Canada Date of Issuance:06/15/2009
(819)478-2400 Revision 19:12/16/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
( P.E.for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7ei Edition(2020)Florida Building Code sections noted herein.
r_
,.DEscrttPTloN:.;Soprema,Roof Underli yments
LABELING•-Labelin shall be'in accordance`with the re quirements of the Accredited Quality� g_ q ' ty Assurance Agency noted
!; herein and FBC 1507.1.1.
j CONTINUED COMPLIANCE:This Evaluation Report is valid until such time asthe named product(s)changes,the referenced
Quality Assurance or production facility location(s)changes,or Code provisions that relate to the product(s)change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval Number(FL#) preceded by the words"NEMO I etc. Evaluated" may be
displayed In advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its
entirety.
INSPECTION:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or Its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
jPrepared by.-
Robert
'�'�taTA79''?;.Tm; The facsimile seal appearing was authorized by Robert
J.M.Nieminen,P.E. _'.y��.:,.dI�Q..:_�,.
Florida Registration No.59166,Florida DCAANE1983 �s�i�;aa%:E•- Nieminen,P.E.on 12/16/2020.This does not serve as
9 °���M•••�••'q••�, an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved In the approval process of the
product.
S. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC,LLC
i
1
!I
ONEMOJetc.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: U nderlayment
Compliance Statement: Soprema Roof Underlayments,as produced by Soprema,have demonstrated compliance
with the following sections of the 7eh Edition(2020)Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use
set forth herein.
2. STANDARDS'
Section Property Standard Year
1504.3.1 Wind resistance FM4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1,1507.2.4,1507.2.9.2 Material standard ASTM D1970 2015
/R905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2/R905.11.2 Material standard ASTM D6163 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Ent' Examination Reference Date
ERD(TST6049) Wind Resistance 2778.07.05 07/15/2005
ERD(TST6049) ASTM D1970/TAS 110(QC) S31370.03.10-1-R1 04/07/2010
ERD(TST6049) FRSA/TRI 04-12(OH) S11150.05.09-112 10/05/2010
ERD(TST6049) ASTM D1970(OH) S37210.11.11 11/09/2011
ERD(TST6049) ASTM D1970(MS) S37210.12.11 22/01/2011
ERD(TST6049) ASTM D1970(MS) S40540.02.13-1 02/19/2013
ERD(TST6049) FRSA/TRI 04-12(MS) S43530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTM D1970(BC) S44870.04.14-2 04/02/2014
ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH) S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated Weathering SOPC-SC8520.04.14 04/27/2015
ERD(TST6049) Wind Resistance SOPC-SC14045.0S.17-R1 06/07/2017
M-D(CER1592) HVHZ Compliance 18-0329.03 06/28/2018
ICC-ES(EVL2396) 2015 IBC Compliance ESR-1524 03/01/2017
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018
NEMO(TST6049) Wind Resistance 4-SOPC-18-0D3.08.18 08/27/2018
NEMO(TST6049) ASTM D4798/D1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4J-SOPC-I9-SSUDL-04.A 03/12/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 41-SOPC-20-SSUDL-01 12/16/2020
PRI(TST5878) ASTM D1970(MS) SOP-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control MLA File No.R16814 12/10/2015
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
UL,LLC(QUA9625) Quality Control Florida BCIS Current
NEMO ETC,LLC Evaluation Report S38010.06.09-1119
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-1121
soprema Roof Underlayments Revision 19:12/15/2020
Page 2 of 9
*._. NEM0 etc.
4. PRODUCT DESCRIPTION:
Material
Product . Plant(s) Descrlptlon
Standard - -= - -
4.1 Lastobond TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyesterfabric
FRSA/TRI 09-28 surfaced,SBS modified bitumen roof
underlayment
4.2 Tri-Built S/A HTTU ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric
Underlayment FRSA/TRI 09-18 surfaced,SBS modified bitumen roof
underlayment
4.3 Lastobond Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.4 RESISTO SA SMOOTH PLY ASTM D1970 Drummondville,QC 'self-adhering,woven polyethylene surfaced,SBS
40 modified bitumen roof underlayment
4.5 Lastobond Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment _
4.6 Lastobond Pro HT-N ASTM D197o Drummondville,QC self-adhering,woven polyethylene surfaced,SBS
modified bitumen roof underlayment available in
two widths;36 and 45 inch
4.7 Lastobond Pro HT-S ASTM D1970 Drummondville,CSC self-adhering,woven polyethylene surfaced,high
I
temperature,SBS modified bitumen roof
underlayment
4.8 EnviroShield ASTM D1976 Drummondville,QC self-adhering woven polyethylene surfaced,high
temperature,SBS modified bitumen roof
underlayment
4.9 Lastobond 195 ASTM D1970 Gulfport,M5 self-adhering,glass-mat reinforced,sand-
Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.10 Lastobond Eaves ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,sand-
Protection Sheet Wadsworth,OH surfaced,SBS modified bitumen roof
i underlayment
4.11 Lastobond Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Guifport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.12 Lastobond Smooth Seal ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
HT Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.13 Tri-Built Smooth HTS/A ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Underlayment Wadsworth,OH surfaced,SBS modified bitumen roof
underlayment
4.14 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-
Smooth Seal HT Wadsworth,OH surfaced,SBS modified bitumen roof
_ underlayment
4.15 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.16 TRI-BUILT Sand-R SA ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Shingle Underlayment Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
I
�I
NEMO ETC,U.0 Evaluation Report S38010.06.09-R19
Certificate ofAuthoritation#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/1S/2020
Page 3 of 9
I
I
I
17NEMOJetc..,
Material
Product Standard Plant(s) Description
4.17 PrimeSource Grip-Rite ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Eave&Valley Protector Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.18 SRS TopShield ICE& ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
WATER DEFENDER Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.19 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-
Gulfport,MS surfaced,SBS modified bitumen roof
Wadsworth,OH underlayment
4.20 Colphene FR GR ASTM D6163 Gulfport,MS self-adhering,fiberglass reinforced,granule-
Wadsworth,OH surfaced,SB5 modified bitumen roof
underlayment
LIMITATIONS:S.
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report Is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e.,Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 150S for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. if not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBCSection: 15072 1507.3 1507.4&15075 1507.7 1507.8&1507.9
Asphalt pay and concrete Tile Metal. Slate or
Underla ent Mechanical Adhesive- Slate-Type Wood Shakes or
Shingles Attach Set Panels Shingles Shingles Shingles
Yes
Lastobond TU HT,Tri-Built S/A HT TU
Yes Yes Yes Yes Yes Yes polntstrlps,1507.1.1.3/
Underlayment See 5.6.1 R905.LL31
Yes
Lastobond Shield,Pro HT-N,RESISTO SA
SMOOTH PLY 40 Yes No No No No Yes point sR905.1.1.3) .3/
R905.1.1.3)
Yes
Lastobond Shield HT,Pro HT-S Yes No No Yes Yes Yes point strip5,1507.1.1.3/
R905.L1.3)
Yes
EnviroShield Yes No No Yes Yes Yes pant strip5,1507.1.1.3/
R905.1.L3)
Yes
Lastobond Eaves Protection Sheet, Yes No No No No Yes pant strips,1507.1.3.31
Lastobond 195
R905.S.L3j
NEMO ETC,LLC Evaluation Report S18010.06.09-1139
24 5 7-EDITION 2020 FBC NON-HVHZ EVALUATION FL2569-R21
Certificate o Authorization tl3 5 1 }
Soprema Roof Underlayments Revision 19:12/15/2020
Page 4 of 9
i
MEMO etc.
TABLE 1: ROOF COVER OPTIONS
FBCSecYhna, _-'=7.2 °15079 15074&25075 - 15077 1S&..8Ai507.9
--
Wood Shakes or
Mechanital Adhes(ve•••I
Asphalt Clay and concrete Tile __ Metal Slate or
Underla ent =
Shingles Panels F 1shingles. 'Slate-Type Shingles
Attach set' shingles
Lastobond ECU,RESISTo LB1236,Till-
BUILT Sand-R SA Shingle Underlayment, Yes
Grip-R(te Eave&Valley Protector, Yes No No No No Yes point strips,1507.1.1.3/
TopShield ICE&WATER DEFENDER, RWS.U.3)
RESISTO LB1244
Lastobond Smooth Seal HT,Tri-Built Yes
Smooth HT S/A Underlayment,Grip-Rite Yes No No Yes i Yes Yes
point subs.1507.1.1.3/
Smooth Seal HT Rsos.1.131
Yes
ColpheneFRGR Yes Yes No No No Yes point strips,ssoz1.13/
R905.1.1.3)
5.6.1 Adhesive-set the is limited to use of the following Approved underlayment/tile-adhesive combinations.
TABLE 1A:ALLOWABLE TILE ADHESIVE UNDER_LAYMENT COMBINAiiONSi -
Underiayment Adhesive Florida Product Approvals
Lastobond TU HT,Tri-Built S/A Dupont`Tile Bondm Roof Tile Adhesive" FL22525 _
HT TU Underlayment ICP Adhesives and Sealants"Polyset®AH-160" _FL6332
5.7 Allowable.Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates(designed to meet wind loads for project)
Underlayment Application,; ' .' -
_ Type. Primer Material(s)
I Lastobond Shield,Lastobond Pra (Optional)ASTM
HT-N,RESISTO SA SMOOTH PLY Deck/ D41,Elastocol Stick, plywood,OSB or Southern Yellow Pine
40,Lastobond Shield HT, sheathing Elastocol Stick Zero ($YP)
Lastobond Pro HT-S, ASTM D41 structural concrete
EnviroShield,Lastobond TU HT,
Tri-Built S/A HT TU Insulation (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
Underlayment,Lastobond Eaves Stick Zero Fiber Roof Board
Protection Sheet,Lastobond 195, self-
Lastobond ECO,RESISTO LB1236,
TRI-BUILT Sand-R SA Shingle adhering
I
Underlayment,Grip-Rite Eave&
Valley Protector,TopShield ICE& Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra-
WATER DEFENDER,RESISTO Stick Zero G
LB1244,Lastobond Smooth Seal
HT,Tri-Built Smooth HT S/A
Underlayment or Grip-Rite
Smooth Seal HT
Deck/ (Optional)ASTM D41 plywood
sheathing
self- ASTM D41 structural concrete
Colphene FIR GR (Optional)Elastocol Dens Deck Prime or SECUROCK Gypsum-
adhering Insulation Stick Zero Fiber Roof Board
Base Sheet (Optional)Elastocol ASTM D226,Type II felt or Modified Sopra-
Stick Zero G
1 Refer to The Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report S18010.06.09-Ri9
Certificate of Authorisation#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12115/2020
Page 5 of 9
lip
1'
WhAol etc.
f TABLE 2- SUBsTRATE OPTiohs FOR ADHERED UNDERLAYMENTS
Substrates(designed to meet wind load`s for project)
Underlayment Application -
Type Primer - _- Material(s)
Lastobond TU HT,Tri-Built S/A HT
'TU Underlayment,RESISTO
LB1236,TRI-BUILT Sand-R SA 6 Existing sand-surfaced,glass-fiber surfaced,
self- Existing RESISTO EXTERIOR I
Shingle Underlayment,Grip-Rite adhering substrate PRIMER mineral-surfaced or film-surfaced roof
Eave&Valley Protector or 1 underlayment'
TopShield ICE&WATER
DEFENDER
"Final acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive Lastobond TU HT,Tri-Built S/A HT
TU Underlayment,RESiSTO LB1236,TRi-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE&
WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick,Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue-and-groove board decking be covered with plywood or OSB priorto installation of the
self-adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but—for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,
Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein(for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 2609 or FBC Residential Chapter 3.
#1 Maximum Desikri Pressure=-45.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)Elastocol Stick,Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Built S/A HTTU Underlayment,self-adhered.
#2 Maximum Design Pressure=-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
NEMO ETC,LLC Evaluation Report S18010.06.09-R19
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 29:12/15/2020
Page 6 of 9
I
't
NEMo,,16tc..
#3 .Maximum Deslsn Pressure=-120.0 asf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer. (Optional)RESISTO EXTERIOR PRIMER
j Base Ply: RESISTO SA SMOOTH PLY 40,self-adhered.
Underlayment: Lastobond TU HT,Tri-Built S/A HTTU Underlayment,self-adhered.
#4 Maximum Design Pressure=-150.0 usf:
Deck: Min.15/32-inch APA-rated BCX plywood(may be Installed C-side up)to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional)RESISTO'EXTERIOR PRIMER
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered.
#5 All other direct-deck, adhered underlayment systems beneath file roof systems carry a Maximum Design
Pressure of-45 psf.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk*carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Des_ien_Pressure=-60.0 W.
beck: Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps(FBC 1517.5.2)spaced 6-
inch o.c.at the 4-inch laps and 6-Inch o.c.in three(3),equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT,Tri-Built S/A HT TU Underlayment,self-adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings,underlayment
attachment shall be in accordance with the manufacturer's Installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE.3 El(POSURE WiTATioNS
Underlayment Prepared Roof Cover ' Maidmum
Installation Type Exposure(days)
Lastobond Eaves Protection Sheet,Lastobond 195,Lastobond Eco,RESISTO LB1236,TRI- Mechanically
BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector,TopShleld ICE 30
&WATER DEFENDER or RESISTO LB1244 attached
Lastobond TU HT,Tri-Built S/A HT TU Underlayment Adhesive-set tile roof 30
system
Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT, Mechanically
Lastobond Pro HT-S,EnviroShield,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A attached 90
Underlayment or Grip-Rite Smooth Seal HT
Lastobond TU HT,Tri-Built S/A HT TU Underlayment or Colphene FR GR Mechanically 180
attached
I�
NEMO ETC,LLC Evaluation Report S18010.06A&R19
Certificate of Authorization#32455 7-EDITION 12020)FBC NON-HVHZ EVALUATION F1.2569-1121
Soprema Roof Underlayments Revision 19.32/15/2020
Page 7 of 9
it
i
i
NFM.o 1 etc:
5.10 Tile Sliapa`s_a Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4:TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS. _
Underlayment Tile Profile Staging Method Maximum Slope
Flat Max.30-tile stack 6.12
Lugged Max.10-tile stack 5:12
Max.10-tile stack(bottom 2-tile stack shall be inverted, 6:12
followed by 8 tiles high on slope,as shown below)
Lastobond TU HT,Tri --
Built S/A HT TU
Underlayment Lugged
Colphene FR GR Flat Max.10-tile stack 5:12
Lugged Max.SO-tile stack 6:12
6. INSTALLATION:
6.1 Soprema Roof Uriderlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.2.1 Installation of RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or
TopShield ICE&WATER DEFENDER self-adhering underlayment in a reroof(tear-off)application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof(tear-off)installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO LB1236,TRI-BUILT Sand-R SA Shingle Underlayment,Grip-Rite Eave&Valley Protector or TopShield ICE
&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
6.3 Lastobond TU HT, Tri-Built S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40,Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield,Lastobond Eaves Protection Sheet,
Lastobond 195,Lastobond Eco,Lastobond Smooth Seal HT,Tri-Built Smooth HT S/A Underlayment,Grip-Rite
Smooth Seal HT, RESISTO L61236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip-Rite Eave & Valley
Protector,TopShield ICE&WATER DEFENDER,RESISTO L61244 or Colphene FR GR:
6.3.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type 11 felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
MEMO ETC,LLC Evaluation Report S38010.06.09-R39
Certificate a/Authorizatton#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL2569-R21
Soprema Roof Underlayments Revision 19:12/15/2020
Page 8 of 9
INEnno etc.
6.3.2 Tile Applications:
Limited to Lastobond TU HT,Tri-Built S/A HTTU Underlayment or Colphene FIR GR.
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida
High .Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
Instructions.
Refer to Section S.8.3 herein for attachment limitations.
Refer to Table 4 herein for the staging limitations.
I' 7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
a. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G10r3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY ASSURANCE ENTITY:
ji
UL,LLC—QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
'I
I
I
i
I
I
I
i
i�
i
MEMO ETC,LLC Evaluation Report S18010.06.09-1119
Certificate ofAuthorization#32455 7-EDITION(2020)FBC NON•HVHZ EVALUATION FL2569-1121
Soprenta Roof Underlayments Revision 19:12/15/2020