Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Approved Survey
SYMBOLS: E- = GUY WIRE ANCHOR ® = CABLE TELEVISION BOX E3 = CATCH BASIN s ® = CLEANOUT © = ELECTRIC BOX ❑r - SOUTHERN BELL BOX 0 - MANHOLE " = FIRE HYDRANT ¢c = LIGHT POLE Q POWER POLE 0 = SPRINKLER HEAD ua = WATER VALVE OW = WELL ❑W = WATER METER 6l = WOOD POWER POLE —X — - CHAIN LINK FENCE —GR GUARD RA I L O = SET 5/8" IRON ROD WITH PLASTIC CAP PSM#6330 ABBREVIATIONS: A/C = AIR CONDITIONER (C) — CALCULATED CBS = CONCRETE BLOCK STRUCTURE CMB = COMMISSIONERS' MINUTES BOOK CMH — CONFLICT MANHOLE CNF = COULD NOT FIND CONC = CONCRETE CLF = CHAIN LINK FENCE DE = DRAINAGE EASEMENT DEP = DEPARTMENT OF ENVIRONMENTAL PROTECTION DB = DEED BOOK DIP = DUCTILE IRON PIPE FH - FIRE HYDRANT FND - FOUND FPL — FLORIDA POWER do LIGHT IP = IRON PIPE I = INVERT IRC = IRON ROD WITH PLASTIC CAP LB = LICENSE BUSINESS LS = LICENSE SURVEY (M) = MEASURED MHWL = MEAN HIGH WATER LINE MON = MONUMENT ORB = OFFICIAL RECORD BOOK (P) = PLAT PB = PLAT BOOK PG = PAGE PL = PROPERTY LINE POB = POINT OF BEGINNING POC = POINT OF COMMENCEMENT PRM = PERMANENT REFERENCE MONUMENT R/W - R I GHT—OF—WAY RC = RAISED CURB RCP — REINFORCED CONCRETE PIPE RPB — ROAD PLAT BOOK (S) — SURVEY SLP = STOP LIGHT POLE SMH = SANITARY MANHOLE SBTMH = SOUTHERN BELL TELEPHONE MANHOLE STMH = STORM MANHOLE TB = TRAFFIC BOX TLP = TRAFFIC LIGHT POLE TV = TELEVISION UE = UTILITY EASEMENT WP - WOOD POLE NORTH LINE OF THE NORTEAST 1/4 OF SECTION 26 II � II � LEGAL DESCRIPTION: THE SOUTH 1/2 OF THE SOUTH 1/2 OF THE NORTH 1/2 OF THE NORTHWEST 1/4 OF THE NORTHEAST 1/4 OF SECTION 26, TOWNSHIP 34 SOUTH, RANGE 39 EAST, LESS RIGHT- OF-WAY FOR SEMINOLE ROAD AND CANAL NO. 5. I I I CONTAINING 216.601 SQUARE FEET OR 4.9725 ACRES, MORE OR LESS. I I I I� SURVEY REPORT: 1. THIS IS A BOUNDARY SURVEY AS DEFINED IN CHAPTER 5J-17.050(10)(a-k), FLORIDA ADMINISTRATIVE CODE. 2. SURVEY BASED ON ST. LUCIE COUNTY SECTIONAL DATA AND FOUND MONUMENTATION. 3. LEGAL DESCRIPTION WAS FURNISHED BY CLIENT. 4. BEARING BASIS: S89'56'33"E ALONG THE NORTH LINE OF THE NORTHEAST 1/4 OF SECTION 26, TOWNSHIP 34 SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA. 5. THIS SITE LIES WITHIN FLOOD ZONE "X", ACCORDING TO THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. 12111CO160 J, EFFECTIVE DATE FEBRUARY 16, 2012. 6. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE SURVEYOR AND IS PROVIDED AS A COURTESY. THE FLOOD ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY. 7. THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS NOT SHOWN ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF ST. LUCIE COUNTY. NO SEARCH OF THE PUBLIC RECORDS HAS BEEN PERFORMED BY ALEXANDER J. PIAZZA PSM, INC. 8. THE EXPECTED USE OF THE SUBJECT PROPERTY IS TO OBTAIN A BUILDING PERMIT AND FALLS WITHIN THE SUBURBAN CATEGORY AS CLASSIFIED IN CHAPTER 5J-17.051(15)(b)(ii), FLORIDA ADMINISTRATIVE CODE. ALL FIELD -MEASURED CONTROL MEASUREMENTS EXCEEDED 1:7,500 FEET ACCURACY REQUIREMENTS FOR THIS CLASSIFICATION. 9. ADDITIONS OR DELETIONS TO THE SURVEY MAP OR REPORT BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. 10. THIS SURVEY IS PREPARED ONLY FOR THE PARTIES LISTED BELOW AND IS NOT ASSIGNABLE. PREPARED FOR: LINDA M. WEIR CARL H. SCHMIDT 11. a COPYRIGHT 2017 BY ALEXANDER J. PIAZZA PSM, INC. HE SKETCH OF SURVEY AND SURVEY REPORT COMPRISE THE COMPLETE SURVEY. THIS SURVEY IS NOT VALID UNLESS THE SKETCH AND REPORT ACCOMPANY EACH OTHER. REPRODUCTIONS OF THIS SURVEY ARE NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER EMPLOYED BY ALEXANDER J. PIAZZA PSM, INC. ALEXANDER J. PIAZZA PSM, INC. DATE OF FIELD SURVEY: 6-23-17 J DATE OF SURVEY: 6-23-17 ALEXANDE ZZA�'%'c' PROFESSIONAL SURVEYOR AND MAPPER FLORIDA CERTIFICATE No. 6330 DATE: I:iawoffill%1A N89'56'33"W 1296.53' (BEARING BASE) NOT PLATTED N8956'33'W 1358.53' S8956'33E 1358.53' S89'S8'33'E 1296.53' 126 S n o 0 �I I� 3 � I8 i n1m o m m ml S89'45'04'E 1297.89' _ S89'45'04'E 1357.99' S89'45'04'E 1357.89' NE 1/4 /4 — — — SECTION 26 1 n Ig $ IX 3 3 � $� V 18 N I I N8933'36'W 1359.26' N8933736-W 1359.26' SECTION BREAKDOWN SCALE=1 "=500' FI ALEXANDER J. PIAZZA PSM, INC. Surveying " Mapping • Consulting 619 SW E3iltmore Street Port St. Lucie, Florida 34983 Phone: (772) 340-7770 U*7280 Fax: (772) 340-2250 BOUNDARY SURVEY 3520 SEMINOLE ROAD SEC 26, TWP 34S, RGE 39E AS PREPARED FOR LINDA M. WEIR 9 I 0 L7 R ff JUN 2 6 2ft `A` 7E of mm rfOlrr. , LOCATION MAP NOT TO SCALE CAD K:\BUILDERS\DWG2017\17-2885 REF FLO CJM / AJP FB• 41 PG. 44 JOB 17-2885 OFF CJM / AJP DATE 6-23-17 CKD AJP SHEET 1 OF 1 DWG D-763 K:API'1LDERS\DWG201;;- j 7-2885.dwg, 61' "2017 1:37:45 PM SYMBOLS: = GUY WIRE ANCHOR © = CABLE TELEVISION BOX O = CATCH BASIN ® = CLEANOUT Q = ELECTRIC BOX ❑1' = SOUTHERN BELL BOX 0 = MANHOLE = FIRE HYDRANT { = LIGHT POLE I I I Q = POWER POLE 0 = SPRINKLER HEAD I I I ua = WATER VALVE QW = WELL ❑W = WATER METER 'R = WOOD POWER POLE —X — = CHAIN LINK FENCE —GR —= GUARD RA I L O = SET 5/8" IRON ROD WITH PLASTIC CAP PSM#6330 ABBREVIATIONS: A/C = AIR CONDITIONER (C) = CALCULATED CBS = CONCRETE BLOCK STRUCTURE CMB = COMMISSIONERS' MINUTES BOOK CMH = CONFLICT MANHOLE CNF = COULD NOT FIND CONC = CONCRETE CLF = CHAIN LINK FENCE DE = DRAINAGE EASEMENT DEP = DEPARTMENT OF ENVIRONMENTAL PROTECTION DB = DEED BOOK DIP = DUCTILE IRON PIPE FH = FIRE HYDRANT FND = FOUND FPL = FLORIDA POWER & LIGHT IP = IRON PIPE INV = INVERT IRC = IRON ROD WITH PLASTIC CAP LB = LICENSE BUSINESS LS = LICENSE SURVEY (M) = MEASURED MHWL = MEAN HIGH WATER LINE MON = MONUMENT ORB = OFFICIAL RECORD BOOK (P) = PLAT PB = PLAT BOOK PG - PAGE PL = PROPERTY LINE POB = POINT OF BEGINNING POO = POINT OF COMMENCEMENT PRM = PERMANENT REFERENCE MONUMENT R/W = RIGHT-OF-WAY RC = RAISED CURB RCP = REINFORCED CONCRETE PIPE RPB = ROAD PLAT BOOK (S) = SURVEY SLP = STOP LIGHT POLE SMH = SANITARY MANHOLE SBTMH = SOUTHERN BELL TELEPHONE MANHOLE STMH = STORM MANHOLE TB = TRAFFIC BOX TLP = TRAFFIC LIGHT POLE TV = TELEVISION UE = UTILITY EASEMENT WP = WOOD POLE NORTH LINE OF THE NORTEAST 1/4 OF SECTION 26 LEGAL DESCRIPTION: THE SOUTH 1/2 OF THE SOUTH 1/2 OF THE NORTH 1/2 OF THE NORTHWEST 1/4 OF THE NORTHEAST 1/4 OF SECTION 26, TOWNSHIP 34 SOUTH, RANGE 39 EAST, LESS RIGHT- OF-WAY FOR SEMINOLE ROAD AND CANAL NO. 5. CONTAINING 216,601 SQUARE FEET OR 4.9725 ACRES, MORE OR LESS N89.56'33"W 1296.53' (BEARING BASE) NOT PLATTED I I I I I I I I I e..111•f I I 4'dm1 d SURVEY REPORT: IAIFi,SE7iBACKPIEQ, 1. THIS IS A BOUNDARY SURVEY AS DEFINED IN CHAPTER 5J-17.050(10)(a-k), FLORIDA ADMINISTRATIVE CODE. _ FRONT �}r--- 2. SURVEY BASED ON ST. LUCIE COUNTY SECTIONAL DATA AND FOUND MONUMENTATION. SIDES -- 3. LEGAL DESCRIPTION WAS FURNISHED BY CLIENT. GNRSIDES I REAR 4. BEARING BASIS: S89.56'33"E ALONG THE NORTH LINE OF THE NORTHEAST 1/4 OF SECTION 26, TOWNSHIP SOUTH, RANGE 39 EAST, ST. LUCIE COUNTY, FLORIDA.N. LN34 5. THIS SITE LIES WITHIN FLOOD ZONE "X", ACCORDING TO THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL NO. 12111CO160 J, EFFECTIVE DATE FEBRUARY 16. 2012. 6. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE SURVEYOR AND IS PROVIDED AS A COURTESY. THE FLOOD ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY. 7. THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS NOT SHOWN ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF ST. LUCIE COUNTY. NO SEARCH OF THE PUBLIC RECORDS HAS BEEN PERFORMED BY ALEXANDER J. PIAZZA PSM, INC. 8. THE EXPECTED USE OF THE SUBJECT PROPERTY IS TO OBTAIN A BUILDING PERMIT AND FALLS WITHIN THE SUBURBAN CATEGORY AS CLASSIFIED IN CHAPTER 5J-17.051(15)(b)(ii), FLORIDA ADMINISTRATIVE CODE. ALL FIELD -MEASURED CONTROL MEASUREMENTS EXCEEDED 1:7,500 FEET ACCURACY REQUIREMENTS FOR THIS CLASSIFICATION. 9. ADDITIONS OR DELETIONS TO THE SURVEY MAP OR REPORT BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. 10. THIS SURVEY IS PREPARED ONLY FOR THE PARTIES LISTED BELOW AND IS NOT ASSIGNABLE. PREPARED FOR: LINDA M. WEIR CARL H. SCHMIDT 11. @ COPYRIGHT 2017 BY ALEXANDER J. PIAZZA PSM, INC. HE SKETCH OF SURVEY AND SURVEY REPORT COMPRISE THE COMPLETE SURVEY. THIS SURVEY IS NOT VALID UNLESS THE SKETCH AND REPORT ACCOMPANY EACH OTHER. REPRODUCTIONS OF THIS SURVEY ARE NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER EMPLOYED BY ALEXANDER J. PIAZZA PSM, INC. ALE/.ANDER J, PIAZZA PSM, INC. r DATE OF FIELD SURVEY: 3-01-17 l DATE OF SURVEY: 3-01-17 ?�' eer —k- ALEXANDER J. PYECZZA PROFESSIONAL SURVEYC)P, AND MAPPER FLORIDA CERTIFICATE No. 6330 DATE: REVISIONS: m N8956'33•W 1358.53' S89'S6'33•E 1356.5Y 23 24 S89:; '33"E 1296.53' — 26 25 l; n n $ 3I I� �8 z � of m m m ml S89'45'04•E 1297.89' _ S8945'04•E 1357.89' s69'45.04•E 1357.89' NE 114 — — — SECTION 26 I 0 2 = Ix 3 8I X Ig I z I N89'33'36•W 1359.26• N89'33'36•W 1359.26• SECTION BREAKDOWN SCALE=1 "=500' ALEXANDER J. PIAZZA PSM, INC. BOUNDARY q1l VEY Surveying Mapping Consulting 3520 SEMINOLE ROAD 61S SW i , street SEC 26TWP 34a, RGE 39E Port St. Luccie,, FloridaFlr34983 AS PREPARED FOR (772) 340-7770 LW2W Fax: (772) 340-2250 LINDA M. WEIR N89'56'33"W 1356.53' 'R a J a 0 z r .. KA LOCATION MAP NOT TO SCALE CAD K:\BUILDERS\DWG2017\17-2885 REF FLO CJM / AJP FB• 41 PG. 44 JOB 17 2885 OFF CJM / AJP DATE 3-01-17 CKD AJP SHEET i OF 1 DWG D-756 i�