Loading...
HomeMy WebLinkAboutEngineering i FL06 A ENGINEERING & TESTING, INC. Phone: (866)781-6889 •Fax: (866) 784-8550 mrww.flor daengineeringandtesting.com 250 S.W.13'h Avenue !' Pompano Beach,FL 33069 DATE: 4/07/17 JOB ORDER#: 17-1243 CLIENT: All Area Roofing it ADDRESS: 3921 S.US Highway 1 Fort Pierce,Florida 34982 PROJECT: Palmatier Residence Flat Wood,Non-Insul Ited Roof Deck ADDRESS: 990 Emerald Avenue Fort Pierce,Florida FBC-2014/ASCE 7-10 DESIGN PRESSURE CALCULATIONS I Proiect Information: Height= 8' Exposure: C Basic/Ultimate Wind..Speed: V,dt=170 mph Length= 19' Category: Il Nominal!Wind Speed: Vna=V„lt*0.6 Width= 13' Slope: <7° (asd=all strength design) Parapet Wall: N/A Residential KZ=0.85, Kzt= 1.0, 0.85 I Design Calculations: Velocity Pressure: q=0.00256*KZK�tKdV VelocityPressure ntt : q=0.00256 0.85 1.0 0.85 170 2 53.45 sf ( ) ( )( )( )( ) ] = p Velocity Pressure (asd): q=0.00256(0.85)(1.0)(0.85)(170*,b.6)2] =32.07 psf Width of Pressure Coefficient: 0.1(13') _ . 1.3' 0.4(8') = 3.2' } use: ;3'0" I I Effective Wind Area: <1 Of 2 f For parapet height three feet(T) or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: Internal Pressure Coefficient: 1) GCP1 = -1.0 1) GCPi = j 0.18 2) GCP2 = -1.8 3) GCP3 = -2.8 u v Q �0 Quality 'I A .gsaurartce 4� I • Page 2,4/07/17,Job A#17-1243 All Area Roofing-Palmatier Residence r; FLD A Flat Wood Non Insulated Roof Deck i 990 Emerald Avenue;Fort Pierce,Florida: i r' 1 Design Pressures Based on Vasd: 1) Field PI = 32.07*[(-1.0)—(0.18)] _-37.8 psf 2) Perimeter P2 = 32.07*[(-1.8)—(0.18)] _-63.5 psf 3) Corners P3 = 32.07*[(-2.8)—(0.18)] _-95.6 ps Attachment Requirements Per RAS-117: Based on the requirements of N.O.A. #14-0529.02, pg 23 of 42, System Type E(3), with a maximum design pressure of -52.5psf; the following are our recommended fastening patterns to attach the proposed base sheet to the wood (non-,,insulated) 19/32" or greater plywood or wood plank deck utilizing approved 11 ga. annular ring shank nails and approved tin caps: Field: 8" o.c. @ 4" laps and 3 staggered rows 8" o.c. P I Perimeter: 6" o.c. @ 4" laps and 3 staggered rows 6" o.c. Corners: 6" o.c. @ 4" laps and 5 staggered rows 6" o.c. .l, Notes: Corners and perimeter area dimension shall not be less than a=3'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty(as applicable). All work shall .be in compliance with the local buildIg code product control notice of acceptance and manufacturer specifications and Florida Building Code 2014 Edition. I Wind load calculations based on ASCE 74% FBC 2014'and information provided by client. Client is responsible for verifying ekisting/proposed conditions/decks as it pertains to the above provided prod Jct approval. p , All work shall be inspected by our field engineer I (or authorized representative) or a building department inspector to verify compliance with specifications. ® N Sincerely, �� ��� 'q'y fir° it 0.48202 w Mark A. Mesiaf$ O� P-•awe Florida Engine Florida},eg.Non4 s/ONP��- Certificate of Authonza/t� �ib���23 II �i