HomeMy WebLinkAboutNotice of Acceptance0 41, MIAMI�❑AU>= c DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) GAF 1 Campus Drive Parsippany, NJ 07054 MiAMi-DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (7 I6) 315-2590 F (786) 315-2599 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of con documentation submitted has been reviewed and accepted by Miami -Dade County RER - Pro used in Miami Dade County and other areas where allowed by the Authority Having Jurisdict This NOA shall not be valid after the expiration date stated below. The Miami -Dade Cot Section (in Miami Dade County) and/or the AHJ (in areas other than Miami` Dade County have this product or material tested for quality assurance purposes. if this product or ntateri the accepted manner, the manufacturer will incur the expense of such testing and the A' revoke, modify, or suspend the use of such product or material within their jurisdiction. REF revoke this acceptance, if it is determined by Miami -Dade County Product Control Section material fails to meet the requirements of the applicable building code. truction materials. The uct Control Section to be )n (AHJ). ity Product Control reserve the right to 1 fails to perform in J may immediately reserves the right to that this product or This product is approved as described herein, and has been designed to comply:with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Timberline HD°, Timberline° Natural Shadow, Timberline° American Harvest', and Fortitude"I Shingles LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, dity, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise' noted herein. RENEWAL of this NOA shall be considered after a renewal application has seen filed and illere has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there l as been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety, INSPECTION: A copy of this entire NOA shall be provided to the user by the man, shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA # 14-1022.20 and consists of pages 1 through 6. The submitted documentation was reviewed by Alex Tigera. C or its distributors and NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 1 of 6 �j ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Asphalt Shingles Materials: Laminate Deck Tyne: Wood i SCOPE This approves GAF Timberline HDI, Timberline® Natural Shadow®, Timberline American' Harvest°, and FortitudeTm Shingles as manufactured by GAF as described in this Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Product Description GAF Timberline HDI Manufacturing Locations #1, 2, 3, 4, 5, 6, 7 GAF Timberline Natural Shadow@ Manufacturing Locations #1, 2, 3, 4, 5, 6, 7 GAF Timberline' American Harvest® Manufacturing Locations #2, 4, 5, 6 GAF FortitudeT"' Manufacturing Locations #1, 4 MANUFACTURING LOCATIOI\ 1. Tampa, FL 2. Michigan City, IN 3. Baltimore, MD 4. Myerstown, PA 5. Ennis, TX 6. Tuscaloosa, AL 7. Dallas, TX 13 '/4" x 39 3/8 13 '/4" x 39 3/e' 13 '/4" x 39 3/8 13 '/4'* x 39 3/8" Specifications TAS 110 Fiberglass reinforced heavy weight asphalt roof shingle, with a laminate profile TAS 110 Fiberglass reinforced heavy weight asphalt roof shingle, with a Laminate profile i TAS 110 Fiberglass reinforced heavy weight asphalt roof shingle, with a Laminate profile TAS 110 Fiberglass reinforced heavy weight asphalt roof shingle, with a laminate profile i NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 2 of 6 0 is EVIDENCE SUBMITTED Test Agency Underwriters Laboratories,LLC Underwriters Laboratories, Inc. Underwriters Laboratories, Inc Underwriters Laboratories, Inc Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. PRI Asphalt Technologies, .Inc. Underwriters Laboratories, Inc. PRI Asphalt Technologies, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Center for Applied Engineering Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Underwriters Laboratories, Inc. Center for Applied Engineering PRI Asphalt Technologies, Inc. PRI Asphalt Technologies, Inc. PRI Asphalt Technologies, inc.. PRI Asphalt Technologies, Inc. PRI Asphalt Technologies, Inc. LIMITATIONS Test Identifier ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 ASTM D3462 TAS 107 TAS 107 TAS 107 TAS 107 TAS 107 TAS 107 TAS 107 TAS 100 TAS 100 TAS 100 TAS 100 TAS 100 TAS-100 4787344101 11 CA48924 l OCA21994 IOCA28717 05CA47541 06CA31580 6AF-101-02-( 06NK05159 GAF-098-02-( 02NK41809 03NK26444 257989 O INK45803 06NK05159 04NK04273 05CA42840 02NK4181 1 03CA35209 04CA 13850 1. 257989 IGAF-044-02-1 'GAF-098-02-I GAF-101-02-1 GAF-1 16-02-1 ELK-083-02-I 'ELK-085 ELK-086 ELK-087 ELK-088 ELK-107 ELK-108 ELK-109 1. Fire classification is not part of this acceptance; refer to a current Approved Roof fire ratings of this product. I' 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with and Rule 61 G20-3 of the Florida Administrative Code. in Date 07/25/16 10/24/1 1 04/22/ 1 1 07/26/11 11/10/06 11 /30/06 11 /02/05 08/09/06 Z 11 /08/05 08/ 1 1 /02 10/ 17/03 05/13/97 04/ 13/94 08/09/06. 02/20/04 1 111 1105 11/11/02 10/ 17/03 08/30/04 04/01 /97 1 01/13/04 1 11 /08/05 1 11 /09/05 2 03/23/06 1 10/16/02 1 10/15/02 1 10/ 14/02 1 10/24/02 1 10/21 /02 1 10/16/02 1 10/09/03 1 10/09/03 1 10/09/03 Materials Directory for Florida Building Code NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 3 of 6 1 INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions.;I 4. Exposure and course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail '13% attached. i LABELING Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. y BUILDING PERMIT REQUIREMENTS 1. Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable evaluate the installation of this system. in order to properly NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 4 of 6 iP 17" OFF 0 11" OFF 6" OFF FULL DBTAIL A COURSI LAYOUT DECK FULL 4th 2nd 5th 1st NOA No.: 16-0811.11 Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 5 of 6 S DETAIL B OVERALL DIMENSIONS AND NAILING PATTERN 39-3/8" f — 14-1 /2" -17-1 /2" 14-1 /2" - 17 !'!1 /2" (368-445mm) (368-445mm) ail guide line i� 6-1/2" - 9-1/2" 6-1/2" - 9-1/2" 5 3/4"-6-114" 11 (185 - 2itmm) (I65. 3a1mm) 1 3—, � /4 —� —� i (146mm - 159mm) v2' -- 2-t2" from bottom of shingle (13-B4 elf seal adhesive on back „ ENHANCED NAILING PATTERN - six nails per shingle* • required by some local codes and required for enhanced wind coverage on certain products. See limited warranty for details. ' I I These shingles MUST be nailed a nominal 6" (152mm) from bottom of of shingle, above the cut outs, as shown. Nails must not be exposed. ' I - I END OF THIS ACCEPTANCE i , I MIAMI•DADE COUNTY NOA No.: 16-0811.11 � ! Expiration Date: 02/21/22 Approval Date: 02/09/17 Page 6 of 6 ' I