HomeMy WebLinkAboutNotice of Acceptance0
41,
MIAMI�❑AU>=
c
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NOA)
GAF
1 Campus Drive
Parsippany, NJ 07054
MiAMi-DADS COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (7 I6) 315-2590 F (786) 315-2599
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of con
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Pro
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdict
This NOA shall not be valid after the expiration date stated below. The Miami -Dade Cot
Section (in Miami Dade County) and/or the AHJ (in areas other than Miami` Dade County
have this product or material tested for quality assurance purposes. if this product or ntateri
the accepted manner, the manufacturer will incur the expense of such testing and the A'
revoke, modify, or suspend the use of such product or material within their jurisdiction. REF
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section
material fails to meet the requirements of the applicable building code.
truction materials. The
uct Control Section to be
)n (AHJ).
ity Product Control
reserve the right to
1 fails to perform in
J may immediately
reserves the right to
that this product or
This product is approved as described herein, and has been designed to comply:with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD°, Timberline° Natural Shadow, Timberline° American Harvest', and
Fortitude"I Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, dity, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise' noted herein.
RENEWAL of this NOA shall be considered after a renewal application has seen filed and illere has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there l as been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety,
INSPECTION: A copy of this entire NOA shall be provided to the user by the man,
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA # 14-1022.20 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera. C
or its distributors and
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 1 of 6
�j
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Asphalt Shingles
Materials: Laminate
Deck Tyne: Wood
i
SCOPE
This approves GAF Timberline HDI, Timberline® Natural Shadow®, Timberline American' Harvest°, and
FortitudeTm Shingles as manufactured by GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test Product Description
GAF Timberline HDI
Manufacturing
Locations #1, 2, 3, 4, 5, 6, 7
GAF Timberline Natural
Shadow@
Manufacturing
Locations #1, 2, 3, 4, 5, 6, 7
GAF Timberline' American
Harvest®
Manufacturing
Locations #2, 4, 5, 6
GAF FortitudeT"'
Manufacturing
Locations #1, 4
MANUFACTURING LOCATIOI\
1. Tampa, FL
2. Michigan City, IN
3. Baltimore, MD
4. Myerstown, PA
5. Ennis, TX
6. Tuscaloosa, AL
7. Dallas, TX
13 '/4" x 39 3/8
13 '/4" x 39 3/e'
13 '/4" x 39 3/8
13 '/4'* x 39 3/8"
Specifications
TAS 110 Fiberglass reinforced heavy weight asphalt
roof shingle, with a laminate profile
TAS 110 Fiberglass reinforced heavy weight asphalt
roof shingle, with a Laminate profile
i
TAS 110 Fiberglass reinforced heavy weight asphalt
roof shingle, with a Laminate profile
TAS 110 Fiberglass reinforced heavy weight asphalt
roof shingle, with a laminate profile
i
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 2 of 6
0
is
EVIDENCE SUBMITTED
Test Agency
Underwriters Laboratories,LLC
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc
Underwriters Laboratories, Inc
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc.
PRI Asphalt Technologies, .Inc.
Underwriters Laboratories, Inc.
PRI Asphalt Technologies, Inc.
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc.
Center for Applied Engineering
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc.
Underwriters Laboratories, Inc.
Center for Applied Engineering
PRI Asphalt Technologies, Inc.
PRI Asphalt Technologies, Inc.
PRI Asphalt Technologies, inc..
PRI Asphalt Technologies, Inc.
PRI Asphalt Technologies, Inc.
LIMITATIONS
Test Identifier
ASTM D3462
ASTM D3462
ASTM D3462
ASTM D3462
ASTM D3462
ASTM D3462
ASTM D3462
ASTM D3462
ASTM D3462
ASTM D3462
ASTM D3462
ASTM D3462
TAS 107
TAS 107
TAS 107
TAS 107
TAS 107
TAS 107
TAS 107
TAS 100
TAS 100
TAS 100
TAS 100
TAS 100
TAS-100
4787344101
11 CA48924
l OCA21994
IOCA28717
05CA47541
06CA31580
6AF-101-02-(
06NK05159
GAF-098-02-(
02NK41809
03NK26444
257989
O INK45803
06NK05159
04NK04273
05CA42840
02NK4181 1
03CA35209
04CA 13850
1. 257989
IGAF-044-02-1
'GAF-098-02-I
GAF-101-02-1
GAF-1 16-02-1
ELK-083-02-I
'ELK-085
ELK-086
ELK-087
ELK-088
ELK-107
ELK-108
ELK-109
1. Fire classification is not part of this acceptance; refer to a current Approved Roof
fire ratings of this product. I'
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with
and Rule 61 G20-3 of the Florida Administrative Code.
in Date
07/25/16
10/24/1 1
04/22/ 1 1
07/26/11
11/10/06
11 /30/06
11 /02/05
08/09/06
Z 11 /08/05
08/ 1 1 /02
10/ 17/03
05/13/97
04/ 13/94
08/09/06.
02/20/04
1 111 1105
11/11/02
10/ 17/03
08/30/04
04/01 /97
1 01/13/04
1 11 /08/05
1 11 /09/05
2 03/23/06
1 10/16/02
1 10/15/02
1 10/ 14/02
1 10/24/02
1 10/21 /02
1 10/16/02
1 10/09/03
1 10/09/03
1 10/09/03
Materials Directory for
Florida Building Code
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 3 of 6
1
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.;I
4. Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail '13% attached.
i
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade
County Product Control Seal as shown below. y
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable
evaluate the installation of this system.
in order to properly
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 4 of 6
iP
17" OFF
0
11" OFF
6" OFF
FULL
DBTAIL A
COURSI LAYOUT
DECK
FULL
4th
2nd
5th
1st
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 5 of 6
S
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
39-3/8"
f — 14-1 /2" -17-1 /2" 14-1 /2" - 17 !'!1 /2"
(368-445mm) (368-445mm) ail guide line
i� 6-1/2" - 9-1/2" 6-1/2" - 9-1/2" 5 3/4"-6-114"
11 (185 - 2itmm) (I65. 3a1mm)
1 3—, � /4 —� —� i (146mm - 159mm)
v2' -- 2-t2" from bottom of shingle
(13-B4
elf seal
adhesive
on back
„
ENHANCED NAILING PATTERN - six nails per shingle*
• required by some local codes and required for enhanced wind coverage on certain products.
See limited warranty for details.
' I
I
These shingles MUST be nailed a nominal 6" (152mm) from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
' I -
I
END OF THIS ACCEPTANCE
i
,
I
MIAMI•DADE COUNTY NOA No.: 16-0811.11
� ! Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 6 of 6
' I