Loading...
HomeMy WebLinkAboutNotice of Acceptance (2) 8+11,4Mi c5 .'q MiAMi-DADECOUNTY E PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T�786)315-2590 F(786)31525-99 NOTICE OF ACCEPTANCE (NOA) wwwmliaInidade.gov/economy CertainTeed Corporation IS Moores Road Malvern,PA 19355 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (in Miami Dade County)and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ nbay immediately revoke, modify, or P sus end the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Deelcs. 9 LABELING: Each unit shall bear a permanent label with the manufacturer's'name or logo; city, state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there':has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shal I be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, 'Ilorida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. is INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. i This NOA revises NOA 914-0224.03 and consists of pages 1 throughh 42. The submitted documentation was reviewed by Alex Tigera. i NOA No.: 14-0529.02 MIAMI•DAD'COUNTY �' IZ C' �1 Expiration Date: 06/19/18 Approval Date: 09/24/15 Pagel of 42 i I I ROOFING SYSTEM APPROVAL Category: Roofing Sub-Cateeory: Modified Bitumen Material: APP/SBS Deck Type: Wood Maximum Design Pressure: -127.5 psE TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 _ -- Test Product Product Dimensions Specification I,' Description CAll Weather/Empire Base 39 3/8"x 65'10"; ASTM D 4601, Type Asphalt coated,fiberglass reinforced Sheet _ Roll weight: 70 lbs. 11 base sheet. �-- - (2 squares) UL Type G2 Flexiglas Base Sheet 39 3/8"x 98'9'; Roll ASTM D 4601,Type Modified Bitumen coated fiberglass weight: 90 lbs. II base sheet., (3 squares) UL Type G2 Flintlastic Base 20 39 3/s"x 49'6';Roll ASTM D 6163, Modified Bitumen coated fiberglass weight: 90 lbs. Grade S,Type I base sheet. (1.5 squares) Flintglas Ply Sheet Type IV 39 3/s"x 1647'; Roll ASTM D 2178,Type Fiberglass,asphalt impregnated ply sheet. weight: 38 lbs. IV (5 squares) UL Type G I Flintglas Premium Ply Sheet 39 3/8"x 1647';Roll ASTM D 2178,Type Fiberglass,,asphalt impregnated ply Type VI weight: 40 lbs. VI sheet. (5 squares) UL Type GI Flintlastic STA 39 3/s"x 32' 10";Roll ASTM D 6222, Smooth su�faced APP Modified weight: 87 lbs. Grade S, Type I Bitumen mlembrane with non-woven -- _ (1 square) polyester nat reinforcement for torch application'. �~ Flintlastic GTA 39.3/8"-x 32'.10";Roll ASTM D 6222, i. Granule surfaced-APR Modified \` / weight: 105 lbs. Grade G,Type I Bitumen membrane with non-woven _i "` -' (I square) polyester niat reinforcement for torch application,. Flintlastic GTA-FR 39 3/s"x 32' 10";Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G,Type I Bitumen membrane with non-woven (1 square) polyester niat reinforcement for torch appl icatiod. Flintlastic GMS 39 3/8"x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 94 lbs. Grade G,Type I Bitumen membrane with non-woven (1 square) polyester nat reinforcement for mop application. i �MIAMI•DADE C NOA No.: 14-0529.02 OUNTY 1 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 2 of 42 I I I' I i TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic Premium GMS 39'/8"x 32' 10"; Roll ASTM.D 6164, Granule su faced SBS Modified weight: 101 lbs. Grade G,Type E " Bitumen membrane with non-woven (1 square) polyester nilat reinforcement for mop applications Flintlastic FR-P 39'/8"x 32' 10";Roll ASTM D 6164, j' Fire resista it, granule surfaced SBS weight: 101 lbs. Grade G, Type I '' Modified Bitumen Membrane with (1 square) non-woven'polyester mat reinforcement for mop application. Flintlastic Premium FR-P 39'/s"x 32' 10";Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 101 lbs. Grade G, Type 11 Modified Bitumen Membrane with (1 square) non-woven polyester mat I;I reinforcement for mop application. Flintlastic FR Dual Cap 39'/e" x 32' 10"; Roll ASTM D 6162, Granule surfaced SBS modified weight: 103 lbs. Grade G, Type I bitumen membrane with a nonwoven (1 square) polyester/fi'ii berglass composite mat reinforcement for use in cold or mop applications. Flintlastic FR Cap 30 39'/8" x 32' 1.0";Roll ASTM D 6163, Fire resistant, granule surfaced SBS weight: 86 lbs. Grade G, Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop application's. Flintlastic FR Cap 30 T 39-3/8"x 32' 10";Roll ASTM D 6163, Granule surfaced SBS Modified weight: 100 lbs. Grade G, Type I Bitumen membrane with fiberglass (1 square) mat reinforcement for torch application'1. Flintlastic Base 20 T 39-3/8"x 33'; Roll ASTM D 6163, Modified Bitumen, coated fiberglass Weight: 81 lbs. Grade S,Type I base sheet for torch application. - - — -,(I-square)- - Flintlastic FR Cap 30 CoolStar 39'/8"x 32' 10";Roll ASTM D 6163, �„ Fire resistant, granule surfaced SBS weight: 88 lbs. Grade G,Type 1 Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop application!Is. Covered with reflective �! CoolStar Gloating. Flintlastic FR Cap 30 T 39'/s"x 32' 10";Roll ASTM D 6163, Fire resistant, granule surfaced SBS CoolStar weight: 102 lbs. Grade G,Type I I, Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar mating. j i NOA No.: 14-0529.02 MIAMI•DADE COUNTY Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 3 of 42 I I I TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED By APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic GTA CoolStar 39 3/8"x 32' 10";Roll ASTM D 6222, Granule su ifaced APP Modified weight: 106 lbs. Grade G, Type I Bitumen membrane with non-woven (I square) polyester n'at reinforcement for torch application;. Covered with reflective CoolStar Coating. Flintlastic GTA-FR CoolStar 39 3/8" x 32' 10";Roll ASTM D 6222, Granule surfaced APP Modified weight: 106 lbs. Grade G, Type i Bitumen membrane with non-woven (1 square) polyester mat reinforcement for torch applicatiorrl Covered with reflective CoolStar Coating. Flintlastic GMS CoolStar 39 3/8"x 32' 10";Roll ASTM D 6164, Granule surfaced SBS Modified weight: 97 lbs. Grade G,Type I membrane with non-woven 'I, Bitumen (1 square) polyester mat reinforcement for mop applicatioiil Covered with reflective CoolStar Coating. Flintlastic Premium GMS 39 3/g"x 32' 10"; Roll ASTM D 6164, Granule sulrfaced SBS Modified CoolStar weight:103 lbs. Grade G,Type II Bitumen membrane with non-woven (1 square) polyester Brat reinforcement for mop applicationl. Covered with reflective CoolStar Coating. Flintlastic FR-P CoolStar 39 3/s"x 32' 10";Roll ASTM.D 6164, Fire resistant, granule surfaced SBS weight: 103 lbs. Grade G, Type I Modified Bitumen Membrane with (1 square) non-woven polyester mat reinforcein,nt for mop application. Covered with reflective CoolStar Coating. Flintlastic Premium FR-P 39 3/s"x 32' 10"; Roll ASTM D 6164, Fire resistant, granule surfaced SBS CoolStar weight: 103 lbs. Grade G,Type II Modified Bitumen Membrane with jj (1 square) non-woven polyester mat reinforcer dent for mop application. Covered with-reflective CoolStar Coating. Flintlastic Ultra Poly SMS 39 3/8"x 32' 10'; Roll ASTM D 6164, Smooth surfaced SBS Modified Base Sheet weight: 90 lbs. (1 Grade S,Type I Bitumen Membrane with non-woven squares) polyester I fiat reinforcement for mop I applications. Glasbase Base Sheet 36" x 98' 9';Roll ASTM D 4601, Type Asphalt coated,fiberglass base sheet. weight: 75 lbs. 11, (3 squares) UL Type G2 !I. r i QMIAMI•DADE COUNTY NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 i Page 4 of 42 I TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLIC NT: TABLE 1 Test Product Product Dimensions Specification Description Flintlastic Poly SMS Base 39 3/8"x 64'3";Roll ASTM D 4601, Modified Bitumen coated polyester Sheet weight: 90 lbs. Grade S, Type it base sheet. (2 squares) UL Type G2 Yosemite Venting Base Sheet 39 3/8"x 32'10';Roll ASTM D 3909 ! Mineral Surfaced fiberglass reinforced weight: 85 lbs. ASTM D 4897,Type buffer sheet. (1 square) II UL Type G3 Flintlastic APP Base T 39 3/8"x 65' 4";Roll ASTM D 6509 Modified Bitumen coated fiberglass weight: 100 lbs. base sheet. (2 squares) Flintlastic Ultra Glass SA 39 3/8"x 33'1 1';Roll ASTM D 1970 I;; Self-adhering, fiberglass reinforced, weight: 73 lbs. SBS modified bitumen base/ply sheet. (1 square) Black DiamondTM Base Sheet 36"x 68'7";Roll ASTM D 1970 ' Self-adhering fiberglass reinforced weight: 78 lbs. modified bitumen base sheet (2 squares) ' APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) FlintBoard ISO Polyisocyanurate foam insulation Ce`rtainTeed Corporation FlintBoardH ISO Polyisocyanurate foam insulation CertainTeed Corp. ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp. High Density Wood Fiberboard Wood fiber insulation board Generic Perlite Insulation Perlite insulation board Generic DensDeck,DensDeck Prime Water resistant gypsum board t Georgia Pacific Gypsum LLC H-Shield Polyisocyanurate foam insulation Hunter Panels LLC ENRGY 3 Polyisocyanurate foam insulation Johns Manville Corp. ENRGY 3 25 PSI Polyisocyanurate foam insulation Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate foam insulation RMax Operating, LLC SECUROCK Gypsum-Fiber Roof Board homogenous fiber reinforced USG Corp. d i I I NOA No.: 14-0529.02 MIAMI•DADE COUNTY Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 5 of 42 I i i I APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Trufast#12 DP Fastener Insulation fastener for wood various Ali ten loh, Brinell &Co.U.S., and steel decks Inc. 2. Trufast 3"Metal Galvalume steel plate Y"round Altenloh,Brinch &Co.U.S., Insulation Plate Inc. 3. FlintFast#12 Coated,carbon steel screw various CertainTeed Corp. 4. FlintFast 3"Insulation Galvalume AZ50 steel plate Y,round CertainTeed Corp. Plate 5. FlintFast#14 Insulation fastener for wood various CertainTeed Corp. and steel decks ! 6. Simplex MAXX Cap Polymer fastner 1" long Simplex Nails,Inc. 7. OMG#12 Standard Insulation fastener for wood various OMG,Inc. Roofgrip and steel. 8. OMG 3"Galvanized Steel Galvalume stress plate 3"round ! OMG,Inc. r Plates 9. Trufast#14 HD Fastener Insulation fastener for wood various Altenloh,Brinell &Co.U.S., and steel decks Inc. 10. OMG Heavy Duty Insulation and membrane VArious j OMG, Inc. fastener 11. OMG 3 in.Round Metal Galvalume AZ50 steel plate 3';,round OMG, Inc. Plates 12. AccutTrac Hextra Carbon steel fastener Various OMG,Inc. 13. AccuTrac Plates Galvalume stress plate. 3"square OMG,Inc. 14. AccuTrac Flat Bottom A2-SS aluminized steel plate 3"square OMG, Inc. Plates i 'I i I i I f' j NOA No.: 14-0529.02 MIAM-DADE COUNTY I Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 6 of 42 p '� I • APPROVED SURFACING/COATING OPTIONS: TABLE 4 Chosen components must be applied according to manufacturer's application instructions.Any coating,listed below,used as a surfacing,must be listed within a current NOA. System Number Manufacturer Application 1. Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at 60 lbs/sq. 2. Generic Slag applied at 300 lbs/sq.,adhered with flood coat of asphalt at 60 Ibs/sq. 3. Karnak Corp. Karnak(497 AF)Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. i 4. CertainTeed Corp. FlintCoat A-150 applied at an applicatiol rate of 1.5 gal/sq. 5. Gardner Asphalt Corp. APOC 4212 Fibered Aluminum Roof Coping applied at an application rate of 1.5 gal/sq. 6. Gardner Asphalt Corp. APOC#400 Sunbrite applied at an application rate of 3 gal./sq. i I I i j I i NOA No.: 14-0529.02 QI- MIAMMMADEOUNTY Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 7 of 42 i i EVIDENCE SUBMITTED: Test Aeeney/Identifier Name Report Date 0 Factory Mutual Research Corp. FM 4470 i 3Y8A1.AM 03/23/96 FM 4470 OD3A3.A1v1 04/04/97 FM 4470 2DOAO.A1Vi 12/23/98 FM 4470 1 D7A4.AM 1 1/09/98 FM 4470 3039046� 06/15/10 FM 4470 3048520 09/19/13 Underwriters Laboratories,Inc. UL 790 R1 1656; 01/11/13 United States Testing Company ASTM D 5147 97457-4 06/03/88 ASTM D 5147 97-457-2R 12/02/87 Momentum Technologies,Inc. ASTM D 4601 AX31 G8D 09/05/08 ASTM D6164 AX31 G81f 06/05/09 ASTM D6222 AX31 G8G 06/05/09 it ASTM D 3909/D 4897 AX31 G8C 09/05/08 TrinitylERD TAS 114(J) 3504.06.01I 1 06/05/01 TAS 114(J) 3507.08.99L 1 04/18/01 TAS 117 (B) 3503.10.0.E 10/10/06 TAS 117(B) 06490.04.07�R 1 06/27/07 TAS 114 (H) Letter ! 04/05/06 TAS 114 3533.01.0,E 01/06/06 TAS 114 3521.07.104 07/29/04 TAS 117 (B)/ASTM D 6862 C8500SC.11.07 1 1/30/07 TAS 114 C8370.08.08 08/19/08 ASTM Physical Properties C I O080.09.0$-R4 03/25/10 ASTM D6164/D4798 C31410.01.11-2 01/10/11 ASTM D4601 C40050.09.12-1 09/28/12 ASTM D1970 C40050.09.12-2 09/28/12 ASTM D5147/D4798 C31410.10.10-R 1 1 1/01/12 ASTM D5147/D4798 C31410.01.1 ILI-R1 1 1/01/12 ASTM D1876 C35460.0511 1 06/16/1 1 ASTM D1.876,TAS 114 (H), C42110.08�12 - 08/13/1.2 TAS 117 (B) FM 4474/TAS 1 14 09670.08�.12 08/20/12 TAS 117B j C35500.02111 02/09/11 ASTM D4798 C31410.01.11-2A-R 1 02/21/13 ASTM D4798 C31410.12!1 13 12/05/13 ASTM D6222 "C40050.12.13-R1 12/31/13 TAS 117, TAS 114 C30310.12.0J-Rl 03/07/14 ASTM D1876,TAS 114(H), 'I C45620.03,14 03/27/14 FM 4474 ASTM D1876,TAS 114(H), d C47320.03.1!4-R1 04/01/15 FM 4474 I PRI Construction Materials ASTM D6163 CTC-032-02-01 01/22/08 Technologies LLC ASTM D6163 CTC-066-02-01 08/09/1 1 ASTM D6222 CTC-070-02-01 08/09/1 1 i MIAMI•DADE CO NOA No.: 14-0529.02 UNTY Expiration Date: 06/19/18 9' Approval Date: 09/24/15 Page 8 of 42 I I EVIDENCE SUBMITTED: !; Test Agency/Idcntifier Name Report Date ASTM D6164/D4798 CTC-093-02-01 08/09/11 ASTM D2178 CTC-122-02'01 03/13/12 ASTM D2178 CTC-123-02-01 03/13/12 ASTM D4601 CTC-127-02"01 03/13/12 ASTM D6163 CTC-128-02-01 06/1 1/12 ASTM D6163 CTC-129-02'�Ol 06/11/12 ASTM D6164 CTC-132-02:01 06/11/12 ASTM D6164 CTC-162-02-01 05/09/13 ASTM D6164 CTC-161-021 01 05/09/13 ASTM D6162 CTC-183-02-O1 10/02/13 ASTM D6164 CTC-190-02-01 12/02/13 ASTM D 1970 CTC-199-02�01 01/22/14 I I I I i aI I I i I �I I II i I I H I li' E I' NOA No.: 14-0529.02 =lAADS CouNTY Expiration Date: 06/19/18 I Approval roval Date: 09/24/15 Page 9 of 42 t � I I I i I i I Membrane Type: APP Modified i Deck Type 1I: Wood,Non-Insulated Deck Description: 19/32" or greater plywood or wood plank System Type E(3): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet,Flexiglas Base Sheet,Flintlastic Poly SMS Base Sheet,Flintlastic Ultra Poly SMS Base Sheet,Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fastening: Base sheet shall be lapped 4" and fastened with I I ga. annular ring slunk nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply Sheet: One ply of All Weather/Empire Base Sheet,Flintlastic'Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet,Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one ni-o or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self-adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Membrane: Flintlastic GTA, lintlastic GTA CoolStar,Flintlastic TA-FR or Flintlastic GTA-FR CoolStar tore i a sere to base/ply sheet. Surfacing: Any of the approved surfacing/coating options listed in Table 4. (Optional) I Maximum Design -52.5 psf. (See General Limitation#7) Pressure: ' I I I ' I i i i i I I !` f I i' I !� NOA No.: 14-0529.02 CMIAM-DADMMOUNTY Expiration Date: 06/19/18 Approval Date: 09/24/15 j Page 23 of 42 'il WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing',Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a frill mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the tap layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in 'approved asphalt, panel size shall be 4'x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all appilications over,closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet,shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip;mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of-45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force(F')value of 275 Ibf., as tested in compliance with Testing Application Standard TAS 105. if the,fastener value, as field-tested,are below 275 Ibf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within 1 specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer,Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the witil"drawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 1 17. 1 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA,General Limitation#9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile,-and/or flashing termination designs shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones(i.e. field, perimeters, and corners).Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA,General Limitation#7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 14-0529.02 MIAMI•DADE COUNTY Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 42 of 42 I. i