HomeMy WebLinkAboutCertification for Design Load Compliancei
Planning & Development Services Department
Building & Code Regulations Division
° 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553�
Certification for Design Load Compliance
Project Name: HUMPHREY POST REPLACEMENT
Project Address: 358 NOTLEM DR.
i
Permit #: Occupancy Type: R Construction Type: V
INSTRUCTIONS FOR USE: 1
• This certification must be completed, signed, and sealed by the design professional of record.
i
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the' following:
o New Residences (single or multi -family) I
o Residential Addition la 19
COPY
o Any accessory structure requiring a building permit FILL
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural) elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
,DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code 2014 Edition with 20 Supplements using ASCE 7-10
y 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X 11 III IV Exposure Category: _ B X C D
4. Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width: 5 ft
S. Mean Roof Height: 10 ft Roof Pitch: o.5 :12 Parapet: N/A ft 1
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
16.0 16.0 16.0 33.6 33 �6 N/A
Zone 1: _33.6 Zone 2: _56.3 Zone 3: -84.7 Zone 4: -36.4 Zone 5: -44.9 Garage: N/A
7. Design Loads: Floor: 40 PSF Roof/Dead: 5 1 PSF Roof/Live: 20 Balcony: _ N/A ISF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specificati11 ons have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
i
County: I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified: —
- `- - Paul Welch P.E. f 29945 / 5115
' - - Print Name Cert # & Co. Cert Auth.
5/23/2C
Sig-*ature, Date,And-Seal
Paul Welch Inc.
1984 S.W. Biltmo
St. Suite $114 Port St. Lucie, FL
Company Name & Address
LCCDV Form # 020-12 Revised 3/15/12 (JS) �