Loading...
HomeMy WebLinkAboutProduct Approval • 'Florida Building Code Online Page 1 of 3 i jA BCIS Home ? Log In User Registration Hot Topics Submit Surcharge i Stats&Facts i Publications i FBC Staff It BCIS Site Map ! L Florida ,q- L Product Approval $ USER: Public User d ,; Product Approval Menu>Product or Application Search>Application List>Application Detail 5 l 1 FL# FL5891-R5 Application Type Revision 1 Code Version 2014 Application Status Approved Comments Archived ❑ Product Manufacturer Therma-Tru Corporation Address/Phone/Email 118 Industrial Drive Edgerton,OH 43517 (419) 298-1740 rickw@rwbldgconsultants.com Authorized Signature Rick Wright rickw@rwbldgconsultants.com Technical Representative Address/Phone/Email i I Quality Assurance Representative Address/Phone/Email Category :Exterior Doors ; Subcategory Swinging Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licen Professional Engineer ® Evaluation Report- Hardcoptly Received 9 Florida Engineer or Architect Name who developed the Lyndon Schmidt, P.E. Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King, P.E. ® Validation Checklist- Hardcopy Received I Certificate of Independence FL5891 R5 COI Certificate of Independence.pdf Referenced Standard and Year(of Standard) Standard I Year SSTD 12 1999 TAS 202 1994 a Equivalence of Product Standards Certified By 0 I Sections from the Code Y ' I I I I http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQ'wtDqu... 5/24/2017 1 Florida Building Code Online Page 2 of 3 i Product Approval Method Method 1 Option D a Date Submitted 06/13/2015 Date Validated 06/28/2015 Date Pending FBC Approval 07/05/2015 Date Approved 08/18/2015 Summary of Products FL# Model,Number or Name Description 5891.1 a. "FiberClassic" 6'8"Impact"Opaque!Fiberglass Single Door(X)Insv Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.1.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports) Other: See INST 5891.1 for Design Pressure Ratings by specific FL5891 R5 AE Eva],5891.1.pdf Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. (For FiberClassic doors,this product approval requires the use of"I" part numbers for these doors, which have been stained or painted within six months of installation.) 5891.2 b. ,'SmoothStar'--' 6'8-"Impact"OpaqueiFiberglass Single Door(X) Insv Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.2.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports{ Other: See INST 5891.2 for Design Pressure Ratings by specific FL5891 R5 AE Eva]!5891.2.pdf Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. (For SmoothStar doors,this product approval requires the use of"I" part numbers for these doors, which have been stained or painted within six months of installation.) 5891.3 c. "ClassicCraft" 6'8 "Impact"Opaque;Fiberglass Single Door(X) Insv Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.3.odf Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.3 for Design Pressure Ratings by specific FL5891 R5 AE Eval 5891.3.pdf Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. 5891.4 d. "FiberClassic" 8'0"Impact"Opaque]Fiberglass Single Door(X)Insv Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.4.odf Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 5891.4 for Design Pressure Ratings by specific FL5891 R5 AE Eva[5891.4.odf Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. (For FiberClassic doors,this product approval requires the use of"Y'part numbers for these doors, ' which have been stained or painted within six months of installation.) 5891.5 e. "SmoothStar" 8'0"Impact"Opaque Fiberglass Single Door(X) Insv Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.5.odf Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other:See INST 5891.5 for Design Pressure Ratings by specific FL5891 R5 AE Evai 5891.5.pdf Model and for any other additional use limitations and Created by Independent Third Party: Yes ► q http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQ'wtDqu... 5/24/2017 Florida Building Code Online Page 3 of 3 installation instructions. (For SmoothStar doors,this product approval requires the use of"I"part numbers for these doors, which have been stained or painted within six months of y installation.) 5891.6 f. "ClassicCraft" 8'0"Impact"Opaque IFiberglass Single Door(X)Insv Outswing Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL5891 R5 II Inst 5891.6.odf Approved for use outside HVHZ:Yes Verified By: Lyndon Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports. Other: See INST 5891.6 for Design Pressure Ratings by specific FL5891 R5 AE Eva] 5891.6.pdf Model and for any other additional use limitations and Created by Independent Third Party: Yes installation instructions. Back Next r Contact Us:: 2601 Blair Stone Road.Tallahassee FL 32399 Phond 850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. :: Privacy Statement::Accessibility Statement::Refun Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records reques electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.13E Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department H address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public n not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To dE are a licensee under Chapter 455,F.S.,please click h&e. Product Approval Accepts: 1� W1 CL"K, = I ....._............__.._......................._................. Credit Card Safe I 6 I r ] I i a 0 I http://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDqu... 5/24/2017 1 YI t 41 THERMANTRU 37.59"MAX.O.A. FRAME WIDTH (a* d •••...THERMA TRU DOORS '�>''• . I IS INDUSTRIAL DR., EDGERTON, OH 43517 PANEL WIDTH ''' ///4flifrs�P�10 o mz' O V c Z 0=U 3 101F X68 mda� "SMOOTH STAR" ® ® E tiz FIRERCRASS SINGLE DOOR In NSW►NG/OUTSWIN Z p J "IMPA s �o z ly a-J m •�{ W D 0- W to GENERAL NOTES m O w 1. This product has been evaluated and is in compliance with the 5th Edition(2014)Florida Building o e Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone"(HVHZ). a a 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base J material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product complies with Section 3 1609.1.2 of the FBC and does not require-an impact resistant covering.This product meets missile $a level"D"and excludes Wind Zone 4 as defined in ASTM E1996 and Section 1609,1.2.2 of the FBC. to o 9 4. For 2x stud framing construction,anchoring of these units shall be the some as that shown for 2x G N buck masonry construction. o o 5. Site conditions that deviate from the details of this drawing require further engineering analysis a N by a licensed engineer or registered architect. TABLE Of CONTENTS -SHEET N"`DESCRIPTION s 1 Typical elevations,design pressures&general notes ,.OVERALL.- DE31GN PRESSURE(PSF) o 0 2 Door panel details SWING FRAME- 3 Horzontal cross sections DIMENSION- PC?SRIVE NEGATIVE •.. DATE: 4123108 Z 4 Vertical cross sections scAe N.T.S. INSWING 37.59"x 82.19" +67.0 .67.0 0 5 Buck and frame anchoring-2X buck masonry construction M.BY. AL m r 6 Frame anchoring-1 X buck masonry construction cn.Dr: LFS 3 7 Bill of Materials&Components OITTSWING 37.59"x 80.69" +67.0 -67.0 DnAW N5 r+D.: FL-5891.2sl 0 SHEET 1 OF 7 N R'\Oients\Therma Tru PERMANENT\Florida!Prod=Ap7' -\FL-5891\Drawings\Cur=AFL-589Ldwg,22 d » e o0 v ® ® NIJ I o= -•ru er GA7 T2- m O N MX-1 P7 nJ 30 0 _'O m n 0 70 n I � 0 y syts - 0.88" I _ O0 (- A i S A I? m s tl A PP I 4 P I M P C � T A n o _ N _ O N �•��Y'J �e'.T .� PRODUCT: oxllmmh Prepares BY- EASEOf " THERMA-7RU Lyndon F. Schmidt �i� AXORID¢•' '•.. ... FIBERGLASS DOOR P•F- No. 43409 "44?bNAL Oda o ? N BUILDING CONSULTANTS. I74b. T -s w[NO 1 28/151 UPDATE TO 5TH ED. 2014 FBC LFS PART OR ASSEMBLY: to p6 17 121 REVISED TO 2010 FBC JK DOOR PANEL DETAILS P.O. Box 230. Volrico. FL 33595 DATE BY Phone No.: 813.659.9197 REVISIONS FBPE CA No. 9813 ®21309 R.W.BUILOWs(1pN1aU1.TANTe iINC• , f (1 ( •1 • t 4 4 tn E ® ® INTERIOR 1p �'�•, l �D;n v y 2 m4v ZOZU 1 21 a u° 9 aW O m r N m D..IL 17 4 , 2 EXTERIOR 3 o 3E o z N 0 3 40 7 , 8 GY 3 B 3 J �o E 20 C A � � a Wd W OVf 1-1/4"MIN. D ` a cc, K 3 4 erne.(TrP.) " of o m ° 4 4 �3�HORIZONTAL CROSS SECTION L o C 3 Shownw/IX sub-buck a a ° 27 40 9 10 m ° INTERIOR INTERIOR 10 v a La LA a C ° N U v d fi o g ° N EXTERIOR EXTERIOR a o 7 40 7 _•?m---�- m V g z J °v ° K a Dare: 4123108 i 20 SCALE: N.T.S.. 9 1-1l4"MIN. B C 8 DWG.Sr: AL m' r EMB,(Tye.) E cNK.ar: LFS 3 1-1/4"MIN. DFAWINo ao.: � � HORIZONTAL CROSS SECTION 3 —__HORIZONTAL CROSS SECTION Eptg,(ryp,J F1-5891.2 0 Inswing configuration 3 Inswing confgurotion a - VET 3 of 7 l7 d as B _ °� o zoZc�i m ` a r 40 40 19 7 19 7 o H o z 8 INTERIOR EXTERIOR 8 zo 0 INTERIOR EXTERIOR � `w^ 1�VERTICAL CROSS SECTION 2 VERTICAL CROSS SECTION ~m 4 Inswing configuration 4 Shownw/IX sub-buck 0 o ~ C o a a 3 �pCY viO,+ INTERIOR EXTERIOR a EXTERIOR INTERIOR N U o cn 5 40 32 8 4 N w a. . 7 33 18 0 IL 40 el N^Q J Gn p ° e ° N^z a C � Dare: 4123108 i scm: N.T.S. e VERTICAL CROSS SECTION 4 VERTICAL CROSS SECTION DWG.BY.' AL m' q Inswing configuration q Outswing configuration cHK.BY.. LFS 3 OPAMNO Ma R FL-5891.2 'a N SHEET_�L OF 7 d ............ ••% 10 to d@ S E n z ozm m o MASONRY TYP.HEAD& MASONRY 9 d`o a OPENING JAMBS OPENING \ `� 'm a a a 4 a0 z Sa FRAME cop K No TYP,HEAD& d JAMBS u+w o z -O `y=z zo �¢u 2X BUCK r O 2X BUCK r �� 2 W x ai Ol ID cm In U a O ~ o 0. a m m v cbv z BUCK ANCHORING _ STRIKE JAMB FRAME ANCHORING HINGEJAMS o ti a Masonry 2X buck construction G CONCRETE ANCHOR NOTES: Q o 1.Concrete anchor locations at the comers may be adjusted to maintain the min. W o edge distance to mortarjoints. o .�2 Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to — RE maintain the min,edge distance to mortar joints,additional concrete anchors may be required to ensure the'MAX.ON CENTER"dimension are not exceeded. 9" 3._Concrete onchortable:—___�— ANCHOR ANCHOR, M(N MIN CLEARANCE 'MIN CLEARANCE \~° ' TO MASONRY TO ADJACENT 10 = TYPE SIZE: EMBEDMENT EDGE ANCNOB 10 N'z u DATE, 4123108 z TAPCON® 1/4" 1.1/4" 2 4" scaE, N.T.S. ° DWG.By: AL m ELCO ®ULTRACON 1/4" 1.1/4" 1" 4" , DNK.BY. LFS 3 y E W DRAWING NO. WOOD SCREW INSTALLATION NOTES: : Cm 1.Maintain a minimum 5/8"edge distance,I"end distance,&I"o.c.spacing HINGE DETAIL LATCH 6 DEADBOLT DETAIL FL-5891,2 w of wood screws to prevent the splitting of wood. ss. 5 Dr 7 0 y .......... fiz n r4fill w n m Z • � ii vcv.. • 0 v a C=U c E m m u n MASONRY ` H g 5 d L OPENING \ e a m d a \V' o`_ J Y FRAME z TYP.HEAD 8. L3 27 0 G c mo T-- JAMBS O o c� I BUCK O s LATCH&DEADBOLT DETAIL o O F- 4. •� a a �m m IT a' u c N U STRIKE JAMB - FRAME ANCHORING HINGE JAMB z Masonry IX buck construct' o N CONCRETE ANCHOR NOTES: i, Concrete anchor locations at the comers may be adjusted to maintain the min. W edge distance to mortar joints. i L7 2. Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to q a - maintain the min.edge distance to mortar joints,additional concrete anchors M may be required to ensure the"MAX ON CENTER"dimension are not exceeded._ w 3. Concrete onchor table -- — _ 10 ANCHOR ANC..HOR MIN:CLEARANCE: MIN CLEARANCE 10 O MIN TO MASONRY' 1.6 ADIACENL' a z TYPE: SIZE EMBEDMENT' HOR., DarD: 4123108 i TAPCON® 1/4, 1.1/4" 2" 4" scALE: N.T.S. 9 mG.Br, AL m ~ TAPCON® 3/16, 1.1/4" 3" 1-1/2" NINGEDETAI! �•en LFS 3 DRAVANO NO.t aaalll WOOD SCREW INSTALLATION NOTES: m 1.Maintain a minimum 518"edge distance,1"end distance,&1"o.c,spacing FL-5891.2 0 6 of wood screws to prevent the splitting of wood, sHEE-r 6 or 7 " 6