HomeMy WebLinkAboutProduct Approval (2) — I i
WIVR "BSI
' P -' .�.: - s.. a'Z�.. ��•E, i�1.� Fi tl33i .m— � ,,�, �_ e
F�OfN!i Depatlmentd BUS Home Log In I User Registration Hot Topics Submit Surcharge Stats&Fads. IPublications FBC Staff j BCIs site Map . Links I Search j
3usincecs r
Prafessinl jProductApproval
�f , USER:Public User
Regulation
7'roduct Aooroval Menu>Product or Anphration Sgorrf >Aopilaxlon List>Application Detail
• tl' FL# FL9777-R7
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived I
Product Manufacturer Owens Corning I
Address/Phone/Email One Owens Corning Parkway
Toledd,OH 43659
(740)404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.keeler@owenscorning.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
i
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report!-Hardcopy Received
I }
Florida Engineer or Architect Name who developed Zachary R. Priest
the Evaluation Report
Florida License PE-74021
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
Validation Checklist- Hardcopy Received
Certificate of Independence F9777 R7 CO �4'I
02 4A FB 2014 Evaluation-Report i"Jeatherlock
Non-HVHZ-final.ndf 'I
CONCEAI.E4 FASTENERS OR ATrACHME"S
Referenced Standard and Year(of Standard) Standard ARE j�,,E11 4ESPON51E1UYV Of THE
97 Cidf'��C4aR OF RECORD 2009
ASTM G 1
i 2005
TAS 103 199S
UL 1897 i 2004
I r
Equivalence of Product Standards
Certified By 011�U
Sections from the Code Lit i
i
I
T I
I
Product Approval Method Method 1 Option D'
Date Submitted 04/19/2016
Date Validated 04/20/2016
Date Pending FBC Approval 04/21/2016
Date Approved 06/08/2016
i
I
Summary of Products
FL# Model,Number or Name Description
9777.1 Weatherlock G Weatherproofing Underiayment
Limits of Use Installation Instructions 'I
Approved for use in HVHZ: No FL9777 R7r I1 OCR14002.4A FBC 2014 Evaluation Repork
Approved for use outside HVHZ:Yes Weatherlock Non-HVIiZ-fifial.odf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other:See evaluation report for,limits of use. Evaluation Reports
FL9777 R71:AE OCR14002.4A FBC 2014 Evaluation Report
Weatherlock Non-HVHZ-final,pdf
Created by Independent Third Party: Yes
_............ .............
_._.:....__�� _ ........- by,Independent
-
9777.2 Weatherlock MAT Waterproofing Underlaymerjt
Limits of Use _ Installation Instructions 'I -T—
Approved for use in HVHZ: No FL9777 R7r II OCR14002.4A FBC 2014 Evaluation Ref)ort
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-fi6al.i3df
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other.See evaluation report for limits of use. Evaluation Reports
FL9777 R7,AE OCR14002.4A FBC 2014 Evaluation Report
Weatherlock Non-HVHZ-fihal.pdf
Created by Independent Third Party: Yes
9777.3 Weatherlock Metal Weatherproofing Underlayment
Limits of Use Installation Instructions _.._....
Approved for use in HVHZ:No FL9777 R7 It OCR14002.4A FBC 2014 Evaluation Report
Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure:N/A Created by Independent Tird Party: Yes
Other.See evaluation report for limits of use. Evaluation Reports
FI-9777 R7 AE OCR1 A-FBC 2014 Evaluation Report
Weatherlock Non-HVHZ-final odf
Created by Independent Third Party: Yes
9777.4 Weatherlock Metal Weatherproofing Underlaynient
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL9777 R7 It OCR14002 4B FBC 2014 Evaluation Report
Approved for use outside HVHZ: No Weatherlock Metal HVHZ-hnal.ndf
Impact Resistant:N/A Verified By: Zachary R. Priest PE-74021
Design Pressure:N/A Created by Independent Third Party: Yes
Other.See evaluation report for limits of use. Evaluation Reports
FL9777 R7 AE OCR14002.'I B FBC 2014 Evaluation Report
Weatherlock Metal HVHZ-final.ndf
Created by Independent Third Party: Yes
9777.5 Weatherlock Specialty Tile&Metal Weatherproofing Underlayrnent
Limits of Use Installation Instructions —_--___
Approved for use in HVHZ:No FL9777 R7 II OCR14002 J FBC n14 Fvdjuation Refit
Approved for use outside HVHZ:Yes Weatherlock Non-HVti7_-fihal.pdf
Impact Resistant: N/A Verified By: Zachary R. Priest 74021
Design Pressure: +0/-105 Created by Independent Tlilyd Party: Yes
Other:See evaluation report for limits of use. Evaluation Reports
FL9777 R7 AE OCR14002'I4A FBC 2014 Evaluation Re for
Weatherlock Non-HVHZ-fl,nal.pdf
Created by Independent Third Party: Yes
Q:ch Next
Contact Us;; 1940 North Monroe Street Tallahassee Ft,32M Phone:85Q-487-'1ft24
The State of Florida is an AA/EEO employer.Convrinht 2007-2013 State of Florida,::PrivaN Statement::Acresslbllity Statement::Refund Statement
i
J\J
r
Certificate of Authorization No. 29824
CREEK 17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)480-3421
EVALUATION REPORT FLORIDA'BUILDING CODE 5T"EDITION(2014)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued April 19, 2016
1 Owens Corning Parkway
Toledo,OH 43657
(806)438-7465
www.owens66rning.com
I
I
Manufacturing Location: Brentwood,NH
Quality Assurance: UL LLC(QUA9625)
SCOPE
Category: Roofing
Subcategory: Underlayments
Code Sections: 1504.3.1,1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3,i1507.4.5, 1507.4.5.2, 1507.5.3,
1507.5.3.2, 1507.7.3. 1507.7.3.2
Properties: Physical properties
REFERENCES
I'
Enti Report No. Standard Year
PRI Construction Materials Technologies(TST6049) NEI-039-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) NEI-042-02-01 REV2 ASTM D 1976 2009
PRI Construction Materials Technologies(TST6049) NEI-045-02-01 :TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST6049) NEI-053-02-01 TAS 103 1995
PRI Construction Materials Technologies(TST6049) NEI-053-02-01 ASTM G 155 2005a
PRI Construction Materials Technologies(TST6049) NEI-093-02-02 IASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) OCF-213-02-01 ASTM D 1623 2009
PRI Construction Materials Technologies(TST6049) OCF-237-02-01 UL 1897 2004
PRI Construction Materials Technologies(TST5878) OCF-252-02-01 'ASTM D 4798 2001
PRI Construction Materials Technologies(TST6049) OCF-252-02-01 ASTM D 1970 2009
PRI Construction Materials Technologies(TST5878) OCF-253-02-02 !ASTM D 1970 2009
PRI Construction Materials Technologies(TST6049) OCF-272-02-01 TAS 103 1995
PRODUCT DESCRIPTION AND LIMITS OF USE
WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive underlayment constructed from SBS
modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq,rolls with nominal dimensions of 3-ft x'l66.7-ft.
WeatherLock@ G is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock@ Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-
sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions
of 3-ft x 66.7-ft.
I
WeatherLock@ Mat is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
OCR14002.4A FL9777-R7 Page 1 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration fdr which this report is valid.
This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not
specifically addressed herein.
I I
G OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLockO Self-Seating Ice&Water Barriers
TECHNICAL SERVICES*LLC p ff
WeatherLock@ Metal .WeatherLock®.Metal is an ASTM D 1970 self-adhesive underlayment constructed from
SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The
product is supplied in 2.0 sq.rolls with nominal dimensions of.3-ft x 66.7-ft.
WeatherLock@ Metal is permitted to be used with mechanics lly Fastened asphalt
shingles, metal roof panels or shingles, wood shakes or shingles, and slate rooting as
prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 90
days.
WeatherLock@ WeatherLock@,Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile&Metal constructed from SBS Modified asphalt and surfacgd with a non-woven polyester fabric.
The product is supplied in 2.14 sq.rolls with nominal dimensions of 3-ft x 71.3-ft.
i
WeatherLock@ Specialty Tile&Metal is permitted to be used with mechanically fastened
asphalt shingles, clay or concrete tile, metal roof i panels or shingles, wood shakes or
shingles, and slate roofing as prescribed in the FBC. WeatherLock@ Specialty Tile &
Metal is permitted to be used with adhered clay or concrete the roofing using either 3MTh4
2-Component Foam Roof Tile Adhesive AH-160 (3M Company) or TiLE BOND Roof
Tile Adhesive(The Dow Chemical Company). Exposure on the roof deck shall be limited
to a maximum 90 days.
The maximum roof slope shall be 6:12 when used,;with clay or concrete tile installations
without battens.. Tile shall be stored on battens to;t•roof slopes greater than 6:12. Tiles
shall not be stacked greater 10 tiles per stack.
PRODUCT APPL1cAmN
Min.Roof Slope: 2:12 or in accordance in with FBC
Application: Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the,underlayment shall be unrolled and
allowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmly
into place to ensure complete contact with the deck. The underlayment shall be installed
with the roll length parallel to the eave, starting at the eave, and with minimum 3"side
laps and minimum 6" end laps staggered 6-ft. from preceding l course. End laps for
WeatherLock@ Specialty Tile &Metal shall be pririled with ASTM D 41 primer or sealed
with asphalt roof cement a minimum of 3-4 inches across the width of the lap.
It is permissible to nail the underlayment 18-inches on-center as needed (nails shall be
installed perpendicular to deck with the nail heads flush to the top surface of the
underlayment). WeatherLock@ Specialty Tile & Metal shall 'be back nailed when
installed on roof slopes greater than$:12.
For valley applications, the roll shall be applied centered along the valley prior to
installing the underlayment at the eave. For eave protection, thle underlayment should
extend to a point 24-inches inside the exterior wall'
The underlayment shall be installed over metal drip edge at the eave, and under the drip
edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible
to install the underlayment under the drip edge in accordance Section 1507.2.9.3.
Min.Application 40°F; Contact the manufacturer when installing at temperatures below the minimum
Temperature: application temperature.
OCR14002.4A FL9777-R7 Page 2 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation,recommended use,or other proeluct attributes that are not
specifically addressed herein.
r
CREEKo E E K OWENS CORNING ROOFING AND ASPHALT LLC
1 111 WeatherlLock(@ Self-Sealing Ice&Water Barriers
TECHNICAL SERVICES, LL'C
WIND RESISTANCE
The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9.
Underlavment System N6.1
Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c.
Underlayment: Weatherl-ock® Specialty Tile & Metal shall be applied, in accordance with
manufacturer's installation instructions to the fastened deck and backnailed along the
selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through
optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied
underlayment,shall be rolled with a minimum 751b steel roller immediately following
application.
Maximum Design -105 psf
Pressure:
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall.prevail. b
4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the F6C requirements.
6) All side lap seams shall be installed to shed water from the deck.
7) The underlayment may be used as described in other current FBC protluct approval documents.
8) Design wind load pressures shall be determined for components and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding.
10) Maximum Design Pressures for, a.given underlayment shall meet or exceed the design wind loads
determined for the roof assembly. . I I
11) All products listed in this report shall be manufactured under a quality a
Rule 61 G20-3. ssurance program in compliance with
I,
I
i
I
I
i
OCR14002AA FL9777-R7 Page 3 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughobt the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not
specifically addressed herein.
i '
OWENS CORNING ROOFING AND ASPHALT LLC
CREEK WeatherLock@ Self-Sealing Ice&Water Barriers
TECHNICAL.SERVICES, LLC
I
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.S have demonstrated compliance with the Florida Building
Code e'Edition(2014)as evidenced in the referenced documents submitted by4he named manufacturer.
R.• 2 16.04.19
E"'SF � .
� -'
No 74021 { .
r 1: . ~ uVWWaWnravY0.f.w,,
.r` -041001
+� STATE OF t w`
%�T••.A- Zachary R.Priest,P.E.
R 1 p' O```. Florida�Registration No. 74021
Organization No.ANE9641
rr►lul►1]►►
i
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing
products under this evaluation.
I
CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other eritity involved in the approval process of the
product.
I
i
r
I'
V
�I
END OF REPORT
�I
�I
i
i
OCR14002.4A FL9777-R7 Page 4 of 4
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,installation, recommended Ipse,or other product attributes that are not
specifically addressed herein.
li