Loading...
HomeMy WebLinkAboutProduct Approval (2) — I i WIVR "BSI ' P -' .�.: - s.. a'Z�.. ��•E, i�1.� Fi tl33i .m— � ,,�, �_ e F�OfN!i Depatlmentd BUS Home Log In I User Registration Hot Topics Submit Surcharge Stats&Fads. IPublications FBC Staff j BCIs site Map . Links I Search j 3usincecs r Prafessinl jProductApproval �f , USER:Public User Regulation 7'roduct Aooroval Menu>Product or Anphration Sgorrf >Aopilaxlon List>Application Detail • tl' FL# FL9777-R7 Application Type Revision Code Version 2014 Application Status Approved Comments Archived I Product Manufacturer Owens Corning I Address/Phone/Email One Owens Corning Parkway Toledd,OH 43659 (740)404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Address/Phone/Email Quality Assurance Representative i Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report!-Hardcopy Received I } Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020 Validated By Locke Bowden Validation Checklist- Hardcopy Received Certificate of Independence F9777 R7 CO �4'I 02 4A FB 2014 Evaluation-Report i"Jeatherlock Non-HVHZ-final.ndf 'I CONCEAI.E4 FASTENERS OR ATrACHME"S Referenced Standard and Year(of Standard) Standard ARE j�,,E11 4ESPON51E1UYV Of THE 97 Cidf'��C4aR OF RECORD 2009 ASTM G 1 i 2005 TAS 103 199S UL 1897 i 2004 I r Equivalence of Product Standards Certified By 011�U Sections from the Code Lit i i I T I I Product Approval Method Method 1 Option D' Date Submitted 04/19/2016 Date Validated 04/20/2016 Date Pending FBC Approval 04/21/2016 Date Approved 06/08/2016 i I Summary of Products FL# Model,Number or Name Description 9777.1 Weatherlock G Weatherproofing Underiayment Limits of Use Installation Instructions 'I Approved for use in HVHZ: No FL9777 R7r I1 OCR14002.4A FBC 2014 Evaluation Repork Approved for use outside HVHZ:Yes Weatherlock Non-HVIiZ-fifial.odf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party: Yes Other:See evaluation report for,limits of use. Evaluation Reports FL9777 R71:AE OCR14002.4A FBC 2014 Evaluation Report Weatherlock Non-HVHZ-final,pdf Created by Independent Third Party: Yes _............ ............. _._.:....__�� _ ........- by,Independent - 9777.2 Weatherlock MAT Waterproofing Underlaymerjt Limits of Use _ Installation Instructions 'I -T— Approved for use in HVHZ: No FL9777 R7r II OCR14002.4A FBC 2014 Evaluation Ref)ort Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-fi6al.i3df Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure:N/A Created by Independent Third Party: Yes Other.See evaluation report for limits of use. Evaluation Reports FL9777 R7,AE OCR14002.4A FBC 2014 Evaluation Report Weatherlock Non-HVHZ-fihal.pdf Created by Independent Third Party: Yes 9777.3 Weatherlock Metal Weatherproofing Underlayment Limits of Use Installation Instructions _.._.... Approved for use in HVHZ:No FL9777 R7 It OCR14002.4A FBC 2014 Evaluation Report Approved for use outside HVHZ:Yes Weatherlock Non-HVHZ-final.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure:N/A Created by Independent Tird Party: Yes Other.See evaluation report for limits of use. Evaluation Reports FI-9777 R7 AE OCR1 A-FBC 2014 Evaluation Report Weatherlock Non-HVHZ-final odf Created by Independent Third Party: Yes 9777.4 Weatherlock Metal Weatherproofing Underlaynient Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL9777 R7 It OCR14002 4B FBC 2014 Evaluation Report Approved for use outside HVHZ: No Weatherlock Metal HVHZ-hnal.ndf Impact Resistant:N/A Verified By: Zachary R. Priest PE-74021 Design Pressure:N/A Created by Independent Third Party: Yes Other.See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCR14002.'I B FBC 2014 Evaluation Report Weatherlock Metal HVHZ-final.ndf Created by Independent Third Party: Yes 9777.5 Weatherlock Specialty Tile&Metal Weatherproofing Underlayrnent Limits of Use Installation Instructions —_--___ Approved for use in HVHZ:No FL9777 R7 II OCR14002 J FBC n14 Fvdjuation Refit Approved for use outside HVHZ:Yes Weatherlock Non-HVti7_-fihal.pdf Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: +0/-105 Created by Independent Tlilyd Party: Yes Other:See evaluation report for limits of use. Evaluation Reports FL9777 R7 AE OCR14002'I4A FBC 2014 Evaluation Re for Weatherlock Non-HVHZ-fl,nal.pdf Created by Independent Third Party: Yes Q:ch Next Contact Us;; 1940 North Monroe Street Tallahassee Ft,32M Phone:85Q-487-'1ft24 The State of Florida is an AA/EEO employer.Convrinht 2007-2013 State of Florida,::PrivaN Statement::Acresslbllity Statement::Refund Statement i J\J r Certificate of Authorization No. 29824 CREEK 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA'BUILDING CODE 5T"EDITION(2014) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued April 19, 2016 1 Owens Corning Parkway Toledo,OH 43657 (806)438-7465 www.owens66rning.com I I Manufacturing Location: Brentwood,NH Quality Assurance: UL LLC(QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1,1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3,i1507.4.5, 1507.4.5.2, 1507.5.3, 1507.5.3.2, 1507.7.3. 1507.7.3.2 Properties: Physical properties REFERENCES I' Enti Report No. Standard Year PRI Construction Materials Technologies(TST6049) NEI-039-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) NEI-042-02-01 REV2 ASTM D 1976 2009 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 :TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-045-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST6049) NEI-053-02-01 TAS 103 1995 PRI Construction Materials Technologies(TST6049) NEI-053-02-01 ASTM G 155 2005a PRI Construction Materials Technologies(TST6049) NEI-093-02-02 IASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) OCF-213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies(TST6049) OCF-237-02-01 UL 1897 2004 PRI Construction Materials Technologies(TST5878) OCF-252-02-01 'ASTM D 4798 2001 PRI Construction Materials Technologies(TST6049) OCF-252-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies(TST5878) OCF-253-02-02 !ASTM D 1970 2009 PRI Construction Materials Technologies(TST6049) OCF-272-02-01 TAS 103 1995 PRODUCT DESCRIPTION AND LIMITS OF USE WeatherLock@ G WeatherLock@ G is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq,rolls with nominal dimensions of 3-ft x'l66.7-ft. WeatherLock@ G is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock@ Mat WeatherLock@ Mat is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ft x 66.7-ft. I WeatherLock@ Mat is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.4A FL9777-R7 Page 1 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration fdr which this report is valid. This evaluation report does not express nor imply warranty, installation,recommended use,or other product attributes that are not specifically addressed herein. I I G OWENS CORNING ROOFING AND ASPHALT LLC WeatherLockO Self-Seating Ice&Water Barriers TECHNICAL SERVICES*LLC p ff WeatherLock@ Metal .WeatherLock®.Metal is an ASTM D 1970 self-adhesive underlayment constructed from SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq.rolls with nominal dimensions of.3-ft x 66.7-ft. WeatherLock@ Metal is permitted to be used with mechanics lly Fastened asphalt shingles, metal roof panels or shingles, wood shakes or shingles, and slate rooting as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock@ WeatherLock@,Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile&Metal constructed from SBS Modified asphalt and surfacgd with a non-woven polyester fabric. The product is supplied in 2.14 sq.rolls with nominal dimensions of 3-ft x 71.3-ft. i WeatherLock@ Specialty Tile&Metal is permitted to be used with mechanically fastened asphalt shingles, clay or concrete tile, metal roof i panels or shingles, wood shakes or shingles, and slate roofing as prescribed in the FBC. WeatherLock@ Specialty Tile & Metal is permitted to be used with adhered clay or concrete the roofing using either 3MTh4 2-Component Foam Roof Tile Adhesive AH-160 (3M Company) or TiLE BOND Roof Tile Adhesive(The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used,;with clay or concrete tile installations without battens.. Tile shall be stored on battens to;t•roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. PRODUCT APPL1cAmN Min.Roof Slope: 2:12 or in accordance in with FBC Application: Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the,underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment shall be installed with the release backer removed and pressed firmly into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3"side laps and minimum 6" end laps staggered 6-ft. from preceding l course. End laps for WeatherLock@ Specialty Tile &Metal shall be pririled with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to nail the underlayment 18-inches on-center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). WeatherLock@ Specialty Tile & Metal shall 'be back nailed when installed on roof slopes greater than$:12. For valley applications, the roll shall be applied centered along the valley prior to installing the underlayment at the eave. For eave protection, thle underlayment should extend to a point 24-inches inside the exterior wall' The underlayment shall be installed over metal drip edge at the eave, and under the drip edge at the rake or valley pan when used as a valley liner. Alternately, it is permissible to install the underlayment under the drip edge in accordance Section 1507.2.9.3. Min.Application 40°F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. OCR14002.4A FL9777-R7 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation,recommended use,or other proeluct attributes that are not specifically addressed herein. r CREEKo E E K OWENS CORNING ROOFING AND ASPHALT LLC 1 111 WeatherlLock(@ Self-Sealing Ice&Water Barriers TECHNICAL SERVICES, LL'C WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9. Underlavment System N6.1 Roof Deck: Min. 15/32-inch CDX plywood attached to wood supports spaced a maximum 24"o.c. Underlayment: Weatherl-ock® Specialty Tile & Metal shall be applied, in accordance with manufacturer's installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The applied underlayment,shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -105 psf Pressure: GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report,the FBC,and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall.prevail. b 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the F6C requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The underlayment may be used as described in other current FBC protluct approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for, a.given underlayment shall meet or exceed the design wind loads determined for the roof assembly. . I I 11) All products listed in this report shall be manufactured under a quality a Rule 61 G20-3. ssurance program in compliance with I, I i I I i OCR14002AA FL9777-R7 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughobt the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended use, or other product attributes that are not specifically addressed herein. i ' OWENS CORNING ROOFING AND ASPHALT LLC CREEK WeatherLock@ Self-Sealing Ice&Water Barriers TECHNICAL.SERVICES, LLC I COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.S have demonstrated compliance with the Florida Building Code e'Edition(2014)as evidenced in the referenced documents submitted by4he named manufacturer. R.• 2 16.04.19 E"'SF � . � -' No 74021 { . r 1: . ~ uVWWaWnravY0.f.w,, .r` -041001 +� STATE OF t w` %�T••.A- Zachary R.Priest,P.E. R 1 p' O```. Florida�Registration No. 74021 Organization No.ANE9641 rr►lul►1]►► i CERTIFICATION OF INDEPENDENCE CREEK Technical Services,LLC does not have,nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. I CREEK Technical Services,LLC is not owned,operated,or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E.does not have, nor will acquire,a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have,nor will acquire,a financial interest in any other eritity involved in the approval process of the product. I i r I' V �I END OF REPORT �I �I i i OCR14002.4A FL9777-R7 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty,installation, recommended Ipse,or other product attributes that are not specifically addressed herein. li