;wee FL# FL12192-R3
Application Type Revision
Code Version 2014
Application Status Approved
*Approv PR.Approvals by DBPR shall be reviewed and ratified
e POC and/or the Commission if necessary.
i
• Comments
Archived
Product Manufacturer KAYCAN LTD
Address/Phone/Email 1 Memorial Drive
Richford,VT 05476
(406)553-6818 Ext 0
alex.jovanovic@kpprodu m
Authorized Signature x
alex.jovanovic@kpproduets.com
Technical Representative Joe Lundine
Address/Phone/Email 402 Boyer St
Williston,VT 05495
(662)252-9991
joe.lundine@kpproducts.com
Quality Assurance Representative Joe Lundine
Address/Phone/Email 402 Boyer St
Williston,VT 05495
(662)2U--9991—_
u ndine@kpprodurts:com
Category Panel Walls
Subcategory Siding
Compliance Method Evaluation Report from a Product Evaluation Entity
Evaluation Entity ICC Evaluation Service,L'LC
Quality Assurance Entity Architectural Testing,Inc.
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Robert J.Amoruso,P.E.
�V Validation Checklist '-Hardcopy Received
Certificate of Independence FL12192 R3 COI ICC Certificate of Independence pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D3679 2009
Equivalence of Product Standards
Certified By
Sections from the Code
I
i
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquk24AUC%2f... 9/22/2015
Horida.Building Code Online Page 3 of 4
I
Approved for use outside HVHZ:Yes Verified By: ICC Evaluation Service,LLC
Impact Resistant:N/A Created by Independent Third'iParty:
Design Pressure: +70/-70 Evaluation Repo rts
' Other:Installed only on exterior walls over solid sheathing FL12192 R31AE ESR-1495 adf
capable of withstanding the design wind loads.Must be
installed as per the manufacturers installation Instructions.
12192.8 Newport Single 6-1/2"IHorizontal
Limits of Use Installation Instructions
' Approved for use in HVHZ:No FL12192 R3 III Kaycan Installation.odf
Approved for use outside HVHZ:Yes Verified By: ICC Evaluation Service, LLC
Impact Resistant,N/A Created by Independent Third Party:
Design Pressure:+70/-70 Evaluation Reports
Other:Installed only on exterior walls over solid sheathing FL12192 R3 AE ESR-1495,odf
capable of withstanding the design wind loads.Must be
installed as per the manufacturers installation instructions.
12192.9 Ocean Park Bevel Double 4 1/2'(Horizontal
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL12192 R3 II Kavcan Installation.odf
Approved for use outside HVHZ:Yes Verified By: ICC Evaluation Service,LLC
Impact Resistant:N/A Created by Independent Third Party:
Design Pressure:+70/-70 Evaluation Reports
Other:Installed only on exterior walls over solid sheathing FL12192 R31 AE E5R-1495.odf
capable of withstanding the design wind loads.Must be
installed as per the manufacturers installation instructions.
12192.10 Ocean Park Cove Double 4-1/2j Horizontal
Limits of Use installation Instructions
Approved for use in HVHZ:No FL12192 R31 iI Kavcan Installation odf
Approved for use outside HVHZ:Yes Verified By: ICC Evaluation Service,LLC
Impact Resistant:N/A Created by Independent Third Party:
Design Pressure:+70/-70 Evaluation Reports
Other:Installed only on exterior walls over solid sheathing FL12192 R3;AE ESR-1495.odf
capable of withstanding the design wind loads.Must be i
installed as per the manufacturers installation Instructions.
i
12192.11 Platinum Series D-4 Double 4"Horizontal
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL12192 R3 II Kay-can Installation.odf
Approved for use outside HVHZ:Yes Verified By: ICC Evaluation Service,LLC
Impact Resistant: N/A Created by Independent Third Party:
Design Pressure: +70/-70 Evaluation Reports
Other:Installed only on exterior walls over solid sheathing FL12192 R3 AE ESR-1495.odf
capable of withstanding the design wind loads.Must be
installed as per the manufacturers installation instructions.
12192.12 Platinum Series D-4 Dutch Lap Double 4"Horizontal Dutch Lap
Limits of Use Installation Instructions I
Approved for use in HVHZ:No FL12192 R3�1 II Kavcan Installatlon.odf
Approved for use outside HVHZ:Yes Verified By: ICC Evaluation Service,LLC
Impact Resistant:N/A Created by Independent Third Party:
Design Pressure: +70/-70 Evaluation Reports
Other:Installed only on exterior walls over solid sheathing FL12192 R3 AE ESR-1495.odf
capable of withstanding the design wind loads.Must be
installed as per the manufacturers installation instructions. 1
12192.13 Platinum Series T-3 Triple 3"Horizontal
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL12192 R3 II Kavcan InstaIlation.odf
Approved for use outside HVHZ:Yes Verified By: ICC Evaluation Service,LLC
Impact Resistant:N/A Created by Independent Third Party:
Design Pressure:+70/-70 Evaluation Reports
Other:Installed only on exterior walls over solid sheathing FL12192 R3 AE ESR-1495.odf
capable of withstanding the design wind loads.Must be
installed as per the manufacturers installation instructions.
i
12192.14 Prova Double 4-1/2'Horizontal I
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL12192 R3 II Kavcan Installation.odf
Approved for use outside HVHZ:Yes Verified By: ICC Evaluation Service,LLC
Impact Resistant:N/A Created by Independent Third Party:
Design Pressure:+70/-70 Evaluation Repo
Other:Installed only on exterior walls over solid sheathing FL12192 R3 AE-
capable of withstanding the design wind loads.Must be
installed as per the manufacturers installation instructions.
12192.15 Sierra Double 4-1/2"Horizontal
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVX;QwtDquk24AUC%2f... 9/22/2015
I
Fastener Choices
' Use aluminum, galvanized steel, or other corrosion-resistant nails, staples,
or screws when installing vinyl siding. Aluminum trim pieces require alu-,
minum or stainless steel fasteners. All fasteners roust be able to penetrate
not less than 3/4" into framing or furring (Fig. 15). (Review your local building
codes for variations that may apply to specific geographic areas.)
I
Nails
Nail heads should be 5/16" minimum in diameter. Shank should be 1/8" in
diameter (Fig. 15).
(IScrew 'Fasteners
as eners can be used if the screws do not restrict the normal expan-
sion and contraction movement of the vinyl siding panel on the wall. Screws
must be centered in the slot with a minimum 1/32" space between the screw
head and the vinyl. Screws must be able to penetrate not less than 3/4 into
framing or furrin an
■ Size #8, truss head or pan head.
® Corrosion-resistant, self-tapping sheet metal type.
Figure 15.
I
t_ /81 minimum u�
3/4" 3/4" 314"
- > d E-
� Fastener- Fastener _ _l:_ �--
4- Fastener � � . ; ,
Vinyl Siding !_ _ E-----Vinyl Siding
vinyl Siding Wood Lap
Siding
Wood WOOd Fan Fold Block or;11 _
Framing Framing (foam under- ' Concrete - Furring Strip
Plywood or 055 layment) (min.3/4")
Sheathing '
Original - -
New Construction Reeiding Over Block or Concrete
13
i
l
a.
t
'yam
r _
„
f
s
Ink
' s
dupe} � �E
It
!k'
r�
,.
r
r
��, � � � A ter; - -- h ai�• . � -
r.
-
• 1
a
r