HomeMy WebLinkAboutRevisions -Jo
OFFICE USE ONLY:
DATE FILED: �� J PERMIT#
REVISION FEE: RECEIPT# 4 2�2
"' N
�I I
.E rc- �F'
PLANNING & DEVELOPMENT S IS
BUILDING&CODE REGULATION IV9NV
AVENUE
�_ :--- w ----- - ---- -- � (77ORT PIER E,FL 349 2-5652
FORT PIERCE,FL 3498
462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCATION/SITE �"
ADDRESS: J amC4 I 2
I.
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
I' �
k 1
3. CONTRACTOR INFORMATION:
- STATE of FL REGJCERT.#: UCIE.,COUNTY CERT.#:
BUSINESS NAME: ODDj
QUALIFIERS NAME: II I
ADDRESS: i-
CITY: STATE: L ZIP:
PHONE(DAYTIME): - IPO FAX: ?Z oZ I'I--y L4
4. OWNER/BUILDER INFORMATION:
NAME:
ADDRESS: I!
CITY: STATE: ! ZIP:
PHONE: FAX: G J
5. ARCHITECT/ENGINEER INFORMATION:
i
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX-
�i
Revised 07/22/2014
I
li
I,
I
i
II
i4
�I
Florida Building Code Online• File ( ovyPage 1 of 2
NO
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff i BCIS Site Map Unks Search
Florida
Product Approval
USER:Public User
Product Anproval Menu>Product or Application Search>Application List>Application Detail
e# s�� FL# FL10450-R8
Application Type Revision
Code Version 2014
Application Status Approved
1'I iEE PLANS AND ALL pROPOSED WORK
Comments ARE SUBJECT TO AID CORRECTIO S
Archived I:::.:.1 REQUIRED By FIELD INSPECTORS THAT-
Product Manufacturer Tarco Roofing .. fitl R1.I�I:NECESI'��.1 IH��RDER TO
Address/Phone/Email One Information Way ®itill�lay iyu C 1I� � PLICARL't CODES.
Suite 225 _
Little Rock,AR 72202 `-
(254)913-7750
smohseen@tarcoroofing.com
Authorized Signature Shaik Mohseen l'
smohseen@tarcoroofing'.com
To�II�ION
Technical Representative Shaik Mohseen SAIIT O dITU T .
Address/Phone/Email 2403 Taylors Valley Roald nrvffNN Ef F0 npLL'i -
Belton,TX 76513 LV1T,
(254)913-7750
smohseen@tarcoroofing.corDL ALN�AND
I'�RMIi t�ii T�� ;PT'ON 3�
rD T �t T L r•:L �e.� Z
Quality Assurance Representative Shaik Mohseen N� '"'
Address/Phone/Email 2403 Taylors Valley Road
Belton,TX 78717
(254)939-3775 Ext210
smohseen@tarcoroofing.com
Category Roofing
Subcategory Underlayments
f
Compliance Method Evaluation Report from a Florida Registe led Architect or a Licensed
Florida Professional Engineer
Evaluation Repori. c Id f;
} Y K
Florida Engineer or Architect Name who developed Robert Nieminen tis
the Evaluation Report -
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/13/2017
Validated By John W.Knezevich,PP
66 Validation Checkli ce'
I
Certificate of Independence FL10450 R8 COI 2016' 01 COI Nieminlen.odf
Referenced Standard and Year(of Standard) Standard I Year
ASTM D1970 2009
ASTM D226 2006
ASTM D3909 1997
ASTM D4869 2005
ASTM D6164 2005
ASTM D6380 2003
FM 4474 2004
http://www.floridabuilding.org/pr/Pr�_app dti.aspx?param=wGEVXQwtDqudsDrIH6I4890... 4/24/2017
Florida Building Code Online Page 2 of 2
FRSA/TRI April 2012(041 12) a 2012
TAS 103 { 1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
i
Date Submitted 04/18/2016
Date Validated
Date Pending FBC Approval 04/25/2016
Date Approved 06/08/2016
' I
Summary of Products
FL# Model,Number or Name Description
10450.1 Tarco Roof Underlayments Roof underlayments for use i'n prepared roof assemblies
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL10450 R8 II 2016 04 FINAL ER TARCO IUNDERLAYMENTS FL10450-
Approved for use outside HVHZ:Yes R8.Ddf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure:+N/A/-217.5 Created by Independent Third Party: Yes
Other: 1.)The design pressure herein Evaluation Reports
pertains to one particular bonded FL10450 R8 AE 2016 04 FINAL ER TARCO UNDERLAYMENTS FL10450-
underlayment application for use beneath R8.Odf
adhesive-set tile systems. Refer to ER Section Created by Independent Third Party: Yes
5.6.2 for details,and other bonded
underlayment systems. 2.) Refer to ER
Section 5 for Limits of Use.
Back Next
I
I
Contact Us::2601 Blair Stone Road,Tallahassee FIL 32399'Phone:850-487-1824
The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to al public-records request,do not send
electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to
Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if
they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to
supply a personal address,please provide the Department with an email address which can be made'available to the public.l To determine if you are a licensee under
Chapter 455,F.S.,please click here
Product Approval Accepts:
I
Credit Card
Safe
I
I
i
I
i
I
I
http://www.floridabuilding.org/pr/P _app_4tl.aspx?param=wGEVXQwtDqudsDrIH6I4890... 4/24/2017
1 1
C0pY
EXTERIOR RESEARCH &DESIGN, LLC.
��/ 'Certificate of Authorization#9503
TRINI 1 1 ERD 353 CHRISTIAN STREET,UNIT#13
OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Tarco Roofing Evaluation Report 10880.07.08-118
One Information Way,Suite 225 FL10450-118
Little Rock,AR 72202 Dale of Issuance:07/11/2008
Revision 8:04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (20i 4) Florida Building Code
sections noted herein.
DESCRIPTION: Tarco Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
i
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
i
r;N The facsimile seal appearing was authorized by Robert Nieminen,
Robert J.M.Nieminen,P.E. P.E.on04/18/2016.This does not serve as an electronically signed
Florida Registration No.59166,Florida DCAANE1983 �'�cs3 �'.+`
g l Ip, al s I document.Signed,sealed hardmples have been transmitted to the
`\�J1i"• t"tsss p Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity]ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for'permitting or design guidance unless retained
specifically for that purpose.
i
i
OT ERDRINITY
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Tarco, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
i
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind Uplift FM 4474 2004
1507.2.3,1507.3.3,1507.5.3, Physical Properties ASTM D226 2006
1507.7.3,1507.8.3,1507.9.3
1507.2.3,1507.2.8,1507.4.5.1, Physical Properties ASTM D4869 2005
1507.4.5.2,1507.5.3,1507.5.3.2,
1507.7.3,1507.7.3.2,1507.8.3,
1507.8.3.2,1507.9.3,1507.9.3.2
1507.2.4,1507.2.9.2,1507.5.3, Physical Properties ASTM D1970 2009
1507.7.3
1507.2.9.2 Physical Properties ASTM D3909 1997
1507.2.9.2,1507.3.3 Physical Properties ASTM D6380 2003
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) ASTM D6164 T6470.08.07-R1 08/30/2007
ERD(TST6049) FM 4474 T6460.06.07-R1 10/09/2007
ERD(TST6049) ASTM D1970 T30160.08.09 08/14/2009
ERD(TST6049) TAS 103 T33190.08.10 08/06/2010
ERD(TST6049) ASTM D1970 T32530.08.10 08/17/2010
ERD(TST6049) FM 4474 T37610.07.11 06/29/2011
ERD(TST6049) ASTM D3909 T40780.04.12 04/06/2012
ERD(TST6049) ASTM D6380 T40790.04.12 04/06/2012
ERD(TST6049) TAS 103 T35410.04.12 04/18/2012
ERD(TST6049) ASTM D1970 T45250.04.13-R2 04/23/2013
ERD(TST6049) Physical Properties T43930.09.13-R2 09/11/2013
ERD(TST6049) Physical Properties TAR-SC9480.15 07/02/2015
ERD(TST6049) Wind-FM4470/4474 TAR-SC5670.14 12/03/2015
ERD(TST6049) Wind-FM4470/4474 TAR-SC8020.14 12/03/2015
PRI(TST5878) ASTM D1970 BRY-018-02-01 08/11/2003
PRI(TST5878) ASTM D1970 BRY-017-02-01 08/11/2003
PRI(TST5878) ASTM D226 TOT-014-02-02 05/18/2004
PRI(TST5878) ASTM D226 TOT-015-02-02 05/24/2004
PRI(TST5878) ASTM D6380 TOT-029-02-01 07/05/2005
PRI(TST5878) ASTM D4869 TOT-009-02-01 09/14/2004
PRI(TST5878) ASTM D4869 TOT-009-02-02 09/14/2004
PRI(TST5878) ASTM D226 TOT-041-02-01 05/24/2006
Miami-Dade(CER1592) FBC HVHZ Certification 12-0420.02 10/03/2013
Tarco Roofing Adhesive compound Affidavit 12/15/2015
UL,LLC.(QUA9625) Quality Assurance Service Confirmation Exp.10/13/2017
Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-118
Certificate of Authorization#9503 FL10450-RB
Revision 8:04/18/2016
Page 2 of 10
I
i
I
i
TRINITY I ERD
4. PRODUCT DESCRIPTION:
4.1 Self-Adhering Underlayments:
LeakBarrier Fast90 Self-adhering Tile Underlayment is an asphalt-saturated organic felt coated on both
sides with asphalt and surfaced on the top side with mineral granules and on the underside with a self-
adhering compound and release film.
LeakBarrier MS300 Ice and Water Armor is a self-adhering, glass mat reinforced, mineral surfaced, SBS
modified roof underlayment.
LeakBarrier PS200HT Ice and Water Armor is a self-adhering, glass mat reinforced, fabric surfaced, SBS
modified roof underlayment.
LeakBarrier PS200M0 Ice and Water Armor is a self-adhering; glass mat reinforced, smooth poly film
surfaced,SBS modified roof underlayment.
LeakBarrier NR500"T is a self-adhering,plastic film surfaced,modified underlayment.
LeakBarrier SS400 Ice and Water Armor is a self-adheringl' fiberglass reinforced, smooth surfaced
modified underlayment.
4.2 Mechanically Fastened Underlavments:
Tarco 15 is an ASTM D226 Type I,15 lb asphalt-saturated organic!felt
Tarco 30 is an ASTM D226 Type II,30 lb asphalt-saturated organicc felt
Tarco NO 30 is an ASTM D4869 Type II asphalt-saturated organiclfelt
LeakBarrier EasyLay is an asphalt-coated polyester fabric roof Underlayment.
4.3 Mechanically Fastened and/or Bonded Underlavments:
Fiberglass Mineral Surfaced Roll Roofing is an ASTM D3909, glass-fiber-reinforced, asphalt-coated,
granule surfaced underlayment used as a valley liner.
ASTM Organic Mineral Surface Tile Underlayment is an ASTM D6380, Class M asphalt-saturated organic
roll roofing sheet.
® i
LeakBarrier EasyMopTM'SBS is a polyester reinforced,SBS modified bitumen roofing underlayment.
4.4 Mechanically Fastened Base Sheets:
LeakBarrier EasyLay UDL 15 consists of a woven-polymeric scrim with a textured fabric on the top
surface. Within this Evaluation Report, it is used as a base sheet in multi-ply Underlayment systems. See
FBC File No.FL16884 use as a stand-alone roof underlayment. '
LeakBarrier EasyLay UDL Basic consists of a woven-polymeric scrim with a textured fabric on the top
surface. Within this Evaluation Report, it is used as a base sheet in multi-ply underlayment systems. See
FBC File No.FL16884 use as a stand-alone roof underlayment.
LeakBarrier EasyLay UDL 50 consists of a woven-polymeric scrim with a non-woven fabric on the top
surface and a rubberized polymeric coating on the back surfaced Within this Evaluation Report, it is used
as a base sheet in multi-ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof
underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
�i
I
i
Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-118
Certificate ofAutharization#9503 F1.10450-118
Revision 8:04/18/2016
Page 3 of 10
r
li'
TRINITY ER®
5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof ci vering.
5.5 Allowable roof covers applied atop Tarco underlayments are follows:
TABLE 1: ROOF COVER OPTIONS l
Underlayment Asphalt Wood Shakes
Nail-On Tile Foam-On Tile Metal I Slate
Shingles &Shingles
LeakBarrier Fast90 Yes Yes Yes No Yes Yes
See 5.5.2
LeakBarrier MS300 Yes No No No Yes Yes
LeakBarrierPS200"r Yes Yes Yes Yes Yes Yes
See 5.5.2
LeakBarrier PS200mu Yes No No Yes Yes Yes
Yes
LeakBarrier NR500"T Yes No No (No copper or Yes Yes
zinc)
LeakBarrier SS400 Yes No No No Yes Yes
Yes Yes
LeakBarrier EasyLay Yes (as base sheet in (as base sheet in Yes Yes Yes
multi-ply system) multi-ply system)
LeakBarrier EasyLay Yes Yes
UDL 15,UDL Basic or Yes Yes Yes Yes
(See FL16884) (as base sheet in (as base sheet in (See FL16884) (See FL16884) (See FL16884)
UDL50 multi-ply system) multi-ply system)
Tarco 15 Yes No No Yes Yes No
Yes Yes
Tarco 30 Yes (as base sheet in (as base sheet in Yes Yes Yes
multi-ply system) multi-ply system)
Tarco NO 30 Yes No No Yes Yes Yes
(double layer) (double layer) (double layer) (double layer)
Fiberglass Mineral Yes
Surfaced Roll Roofing Valley Liner per No No No No No
1507.2.9.2(2)
ASTM Organic Mineral
Surface Tile Yes Yes Yes No Yes Yes
Underlayment See 5.5.2
LeakBarrier EasyMop Yes Yes Yes No Yes Yes
SBS See 5.5.2
I
5.5.1 Tarco 15,Tarco 30,Tarco NO 30 and EasyLay may be used as a mechanically attached base layer followed
by a LeakBarrier self-adhering top layer or asphalt-applied ASTM Organic Mineral Surface Tile
Underlayment or LeakBarrier EasyMop SBS with allowable roof If
noted above for the respective top
layer underlayments. d
5.5.2 "Foam-On Tile" is limited to use of 3M 2-Comp9nent Foam Roof Tile Adhesive AH-160 (FL6332)
applications unless tensile adhesion./ long term aging data from an accredited testing laboratory is
provided.
II
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R8
Certificate of Authorization#9503 FL10450-RB
Revision 8:04/18/2016
Page 4 of 30
I
I,
i
QOTRINITY ERD
5.6 Allowable Substrates:
5.6.1 LeakBarrier self-adhering direct-bond to deck:
➢ New untreated plywood (unprimed or primed with ASTM D41 primer);
➢ Existing plywood(unprimed or primed with ASTM D41 prirr'er);
➢ New or existing OSB(unprimed or primed with ASTM D41 primer);
➢ Structural concrete(unprimed or primed with ASTM D41 primer).
Note: Tarco does not require priming of new or existing plywood or OSB sheathing. New or existing
plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of LeakBarrier
membranes.
ASTM Organic Mineral Surface Tile Underlayment or LeakBarrierl'EasyMOp SBS Direct-Bond to Deck:
➢ ASTM D41 primed structural concrete.
Note:Refer to 5.6.4 for uplift limitations associated with direct-deck underlayment installations where the
overlying roof cover is foam-on tile roofing.
5.6.2 Bond to Mechanically Attached Base Sheet:
LeakBarrier self-adhered to:
➢ ASTM D226,Type I or II felt;
➢ ASTM D4869 felt;
➢ LeakBarrier EasyLay, LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier
EasyLay UDL 50.
r
ASTM Organic Mineral Surface Tile Underlayment or LeakBarrierl;EasyMop SBS in hot asphalt to:
➢ ASTM D226,Type I or II felt;
➢ ASTM D4601,Type II base sheet.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems,base layer shall be attached
per minimum requirements of FRSA/TRI April 2012(04-12).
5.6.3 LeakBarrier Self-Adhering Bond to Other Substrate Types:
➢ ASTM D41 primed metal (flashing metal,valley metal,etc.)
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on tile systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in, foam-on tile applications.
Maximum Design Pressure is the result of testing for wind load desistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied).Refer to FBC 1609 for determination of design wind loads.
5.6.4.1 Maximum Design Pressure=-75.0 psf:
r
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ
Primer: (Optional)ASTM D41
Base Ply: (Optional)LeakBarrier PS200"'u,self-adhered.
Underlayment: LeakBarrier PS200"T,self-adhered.
I'
5.6.4.2 Maximum Design Pressure=-120.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ
Primer: (Optional)ASTM D41 P
Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200""u or LeakBarrier EasyBase,
rolled into place to create continuous bond
Base Ply: (Optional)LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
I
i
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-R8
Certificate of Authorization 1i9503 p I FL10450-R8
Revision 8:04/18/2016
Page 5 of 10
�i
I
I'
r
0
I
TRINITY(ER®
5.6.4.3 Maximum Design Pressure=-217.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: (Optional)ASTM D41
Base Ply: (Optional)LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
5.6.4.4 All other direct-deck, adhered Tarco underlayment systems',,beneath foam-on tile systems carry a
Maximum Design Pressure of-45 psf.
5.6.4.5 Maximum Design Pressure=-45.0 psf*:
Deck: Min.15/32-inch plywood to meet project requirements to.satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay UDL 15,LeakBarrier EasyLay UDLI-Basic or LeakBarrier EasyLay UDL 50(48"wide
rolls);See FBC FL16884.
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6"o.c.at the 4-inch wide side laps and 8"o.c.at three(3)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier PS200Mu,self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
5.6.4.6 Maximum Design Pressure=-60.0 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 7"o.c.at the 4-inch wide side laps and 7"o.c.at three(3)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier P5200mu,self-adhered 1
Underlayment: LeakBarrier PS200"T,self-adhered.
5.6.4.7 Maximum Design Pressure=-60.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay UDL 15,LeakBarrier EasyLay UDLIBasic or LeakBarrier EasyLay UDL 50(48"wide
rolls);See FBC FL16884. C
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6"o.c.at the 4-inch wide side laps and 6"o.c.at four('4)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier P5200mu,self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
5.6.4.8 Maximum Design Pressure=-82.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay
Fasteners: Simplex MAXX Cap Fasteners p
Spacing: 8"o.c.at the 4-inch wide side laps and 8"o.c.at four(4)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier PS200mu,self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
5.6.4.9 Maximum Design Pressure=-120.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay V
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 4"o.c.at the 4-inch wide side laps and 4"o.c.at four(4)equally spaced,staggered center rows.
Base Ply: (Optional)LeakBarrier PS200Mc,self-adhered
Underlayment: LeakBarrier PS200"T,self-adhered.
I
Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-R8
Certificate ofAuthorization#9503 FL10450-R8
Revision 8:04/18/2016
Page 6 of 10
I
• . • \ 1
• 1./
TRINITY ERD
5.6.4.10 For mechanically attached base sheet in a multi-ply system,the maximum design pressure for the selected
assembly shall,at a minimum, meet or exceed the Zone 1 design pressure determined in accordance with
FRSA/TRI April 2012(04-12),Appendix A,Table 1A or FBC 1609. Zones 2 and 3 shall employ an attachment
density designed by a qualified design professional to resist the elevated pressure criteria. Commonly
used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1. Assemblies above marked with an
asterisk*carry the limitations set forth in Section 2.2.1.5.1(a)of FM LPDS 1-29 for Zone 2/3 enhancements.
5.7 Exposure Limitations:
LeakBarrier EasyLay, FAST 90,ASTM Organic Mineral Surface Tile Underlaymenit and LeakBarrier EasyMop
SBS shall not be left exposed for longer than 180-days after installation.
LeakBarrier PS200"T shall not be left exposed for longer than 120=days after installation.
LeakBarrier MS300, NR500"T, PS200""" or SS400 shall not be left exposed for, longer than 30-days after
installation.
Tarco 15, Tarco 30 and Tarco NO 30 shall be covered as soon as possible after installation; exposure for
more than 24 hours after installation could adversely affect performance.
6. INSTALLATION:
6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and primed the substrate(ifjapplicable).
6_3 LeakBarrier®Fast90®Self-Adhering Tile Underlayment:
6.3.1 EasyLay shall be installed in compliance with the requirements for 90# felt�underlayment (except the
product is self-adhered)in FBC Sections 1507 for the type of prepared roof cove i ring to be installed.
6.3.2 Non-Tile Applications: i
Cut the Fast90 roll into 12'to 16'sections for workability and allow to relax prior to application.
Chalk a plumb line 36"from all outside perimeters;then chalk plumb lines 32" apart, upslope to the ridge
line.
Membrane Application:
➢ Place a full width piece of Fast90 on the prepared substrate, parallel to the eave edge of the roof,with
the selvedge edge positioned upslope and in-line with the 15t chalk line.
➢ Fold back half the sheet and remove the exposed release film, taking care not to displace the
membrane
➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles
and ridges,and repeat for the other half of the sheet.
➢ Remove selvage release film,if present,and install capped or tin tagged nails 6"o.c. in the center of the
selvedge edge.
➢ Install the subsequent sheets in the same manner,with upslope selvedge edges in-line with chalk lines,
with 4"side laps and 8"end laps.
➢ Seal all 8" end laps 1/16"thick application of asphalt plastic cement and stagger all end laps minimum
36".
➢ Roll the entire surface with a weighted roller,paying particular attention to side laps,end laps and eave
/rake areas to ensure a complete bond.
6.3.4 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Wait a minimum of 24 hours prior to loading roof tiles.
Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-118
Certificate of Authorization#9503 FL10450-R8
Revision 8:04/18/2016
Page 7 of 10
i
II �
I,
TRINITY�ER®
All tiles shall be staged four tiles perpendicular to slope,six tiles on top,parallel to slope; not to exceed 10
tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12I!for lugged tiles. If tiles are to be left in a
staged condition for more than 30 days,tiles shall be staged two tiles perpendicular to slope,four tiles on
top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for
lugged tiles.
At roof pitch in excess of those noted above, the tiles shall be(staged behind a nominal 1 x 2 horizontal
batten.
6.4 LeakBarrier®MS300,PS200"T.PS200Mc.NR500"T or SS400 Ice and Water Armor:
6.4.1 MS 300, PS200"T, PS200MU, NR500"T or SS400 shall be installed!in compliance with the requirements for
ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.4.2 Non-Tile Applications:
Cut MS 300, PS200"T, PS200mu, NR500"T or SS400 to manageable sections and allow to relax prior to
application.
Membrane Application:
➢ Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend
approximately 3/8"over the eave and rake with the selvedge edge positioned upslope.
➢ Fold back the upslope half of the sheet and remove the exposed release film taking care not to displace
the membrane
➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles
and ridges
➢ Apply a 1/16" thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3"
onto the deck surface.
➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the
substrate from the centerline out. I;
➢ Seal all 6" end laps with a 1/16" thick application of asphalt plastic cement and stagger all end laps
minimum 36". 1 JI
➢ Remove selvage release film, if present,and install second and subsequent courses in a similar manner.
➢ Install capped or tin-tagged nails 6"o.c.along the centerline of the laps.
➢ At all T-joints,where an end-lap and the next overlapping course intersect,apply a bead of roofing laps
cement before the overlapping course is laid.
➢ Roll the entire surface with a weighted roller,paying particular attention to side laps,end laps and eave
/rake areas to ensure a complete bond.
6.4.3 Tile Applications(PS200"T only): I'
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Wait a minimum of 24 hours prior to loading roof tiles.
All tiles shall be staged four tiles perpendicular to slope,six tiles on top,parallel to slope; not to exceed 10
tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a
staged condition for more than 30 days,tiles shall be staged two tiles perpendiicular to slope,four tiles on
top, parallel to slope; not to exceed 6 tiles total to a maximum rpof pitch of 5:12 for flat tiles and 6:12 for
lugged tiles.
At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal
batten.
I
I
Exterior Research and Design,I.I.C. Evaluation Report 10880.07.08-118
Certificate ofAuthorizotion#9503 I FL10450-118
Revision 8:04/18/2016
Page 8 of 10
I
TRINFY II ERD
I
6.4.4 Multi-Ply Underlavment Systems:
LeakBarrier® SS400 Ice and Water Armor followed by LeakBarrier® SS400 Ice and Water Armor(direct-to-
deck per 5.6.1 or over mechanically attached base sheet per 5.6 J2)is allowable ifor use under mechanically
attached prepared roof systems. Limits of use are those associated with the top-layer material. This is not
a requirement,but is allowable if a multi-ply underlayment system is desired.
6.5 Tarco 15 and 30:
6.5.1 Tarco 15 and 30 shall be installed in compliance with the requirements for ASTM D226, Type I and II
underlayments,respectively,in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.5.2 Non-Tile Applications:
Reference is made to the current edition of the NRCA Steep-slope Roofing Manual.
6.5.3 Tile Applications,base laver in multi-ply system(Tarco 30 only):
Reference is made to FRSA/TRI April 2012(04-12)Installation Manual and Table 1 herein.
6_6 Tarco NO 30•
6.6.1 Tarco NO 30 shall be installed in compliance with the requirements for ASTM D4869,Type II underlayment
in FBC Sections 1507 for the type of prepared roof covering to be installed; 1507.4.5.2 (1), 1507.5.3.2 (1),
1507.7.3.2(1), 1507.8.3.2(1)or 1507.9.3.2(1).
6.7 LeakBarrier EasyLay:
6.7.1 EasyLay shall be installed in compliance with the requirements for ASTM D226,Type I or II underlayment in
FBC Sections 1507 for the type of prepared roof covering to be installed.
6.7.2 Re-fasten any loose decking panels, and check for protruding nal:il heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application.
6.7.3 Non-Tile Applications:
Place a full width section of EasyLay,parallel to the eave edge ofi'the roof and unroll 2 to 3 feet with the lay
lines facing up, and position to the edge of the eave and rake. Install a few fasteners at the top, near the
rake, and roll out the sheet to a manageable length. Pull, straighten and align the sheet so that any
wrinkles are eliminated and the sheet is even with the eave edge,. Fasten with 3/8"headed roofing nails or
1" capped (plastic or metal) nails, driven by hand or pneumatically,spaced 6" o.c. at all laps in the center
of the seam area,and two staggered rows fastened 12"o.c. in the field of the sheet. Install nails such that
the head of the nail is flush with the surface, without cutting into the surface. Fasten from the top to
avoid walking or kneeling on unsecured sheet. Continue to thIe end of the sIubstrate and fasten down.
Align the next roll over the preceding sheet so as to form a minimum 4", water-shedding lap, and install
per instructions above. Apply subsequent sheets in the same manner, with minimum 4" water-shedding
laps and minimum 8"end-laps,which are staggered minimum 36"fro the preceding course.
For double layer applications, follow the instructions noted above, but using a minimum 19", water-
shedding side lap.
Allow for minimum 6"up the vertical transitions and minimum 6 over hips and ridges.
At valleys,first install a vertical length of EasyLay down the center of the valley,then start at the low point
and work to the high point, rolling the membrane from the center outward in each direction, ensuring no
wrinkles or tears. Covered with valley-metal or other valley lining material in accordance with NRCA
recommendations.
Apply a thin coat of asphalt plastic cement to waterproof areas where any cuts or tears have occurred.
11
Seams or joints that require adhesive or sealant can be treated with high qualii plastic cement(asbestos
free).
Exterior Research and Design,LLC. Evaluation Report 30880.07.08-118
Certificate of Authorization#9503 FL10450-118
Revision 8:04/18/2016
Page 9 of 10
0
TRINITY I ERD
6.7.4 Tile Applications,base laver in multi-ply system:
Reference is made to FRSA/TRI April 2012(04-12) Installation Manual and Table 1 herein.
6.8 ASTM Organic Mineral Surface Tile Underlavment:
6.8.1 Shall be installed in compliance with the requirements for ASTM D6380, Class M sheets in FBC Sections
1507 for the type of prepared roof covering to be installed.
I
6.8.2 Non-Tile Applications:
Reference is made to the current edition of the NRCA Steep-slope Roofing Manual and ARMA
recommendations for installing shingle underlayments and flashings.
6.8.3 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be
loaded and staged in a manner that prevents tile slippage and/or;;damage to the;underlayment.
6_9 LeakBarrier'"'EasyMop SBS:
6.9.1 Shall be installed in compliance with current Tarco published installation requirements, subject to the
limitations herein.
6.9.2 Non-Tile Applications:
For mechanically attached applications: Secure LeakBarrier EasyMop SBS using 3/8-inch headed roofing
nails or 1-inch diameter cap-nails spaced 9-inch o.c.within the 4-inch wide side laps and 12-inch o.c.in two
(2) equally spaced, staggered center rows in the center of the sheet. End-laps shall be minimum 6-inch
wide, and offset end-laps minimum 3-feet from course to course. Seal end laps in accordance with Tarco
requirements.
For bonded applications: Fully adhere LeakBarrier EasyMop SBS in hot-asphalt to the substrates noted in
Section 5.5. Side laps shall be minimum 4-inch and end-laps minimum 6-inch wide, and offset end-laps
minimum 3-feet from course to course. Side and end-laps shall be fully adhered in a complete mopping of
hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. Consult Tarco
instructions regarding back-nailing requirements.
6.9.3 Tile Applications:
Refer to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein; Tile shall be loaded and
staged in a manner that prevents tile slippage and/or damage to the underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly aevaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered,for F.A.C. Rule 61G20-3 QA requirements
9. QUALITY ASSURANCE ENTITY:
UL, LLC.—QUA9625;(847)664-3281
-END OF EVALUATION REPORT-
i
i
i
Exterior Research and Design,LLC. Evaluation Report 10880.07.08-118
Certificate of Authorization#9503 FL30450-118
Revision 8:04/18/2016
Page 10 of 30
i