Loading...
HomeMy WebLinkAboutProduct Approval (2) 602017 In.rida Building Code Online COD --i �y�u�+ ��} SSG. 'Y'°'W L.. x• (p � #'P � ��+R p`, 4',•".'� �+L.a: "'+��3 ;ate C � +`t+ � � � 1 BCIS Home I Log In User Registration Hot Topla I Submit Surcharge I Stats&Facts Publications I FBC Staff I BCIS Site Map I Links I Search dNr mProduct A roval %7.: USER:Public Approval Product Approval Menu>Product or Application Search>Application List>Application Detail I Application Type New Code Version 2014 1 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. d Comments Archived I Product Manufacturer Elixir Door and Metal Company Address/Phone/Email 1215 Pope Drive 1 Douglas, GA 31533 f (912)493-2215 ryarberry@elixirdmc.com Authorized Signature Randall Yarberry 1 ryarberry@elixirdmc.com �' 9 Technical Representative PTC Product Design Group Address/Phone/Email PO Box 520775 Longwood,FL 32752 (321)690-1788 J info@ptc-corp.com Quality Assurance Representative Address/Phone/Email I Category Exterior Doors Subcategory Swinging Exterior Door Assemblies I! Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By American Architectural Manufacturers Association h 9 Referenced Standard and Year(of Standard) Standard I Year ASTM E330 2002 Equivalence of Product Standards Certified By l� Product Approval Method Method 1 Option A i Date Submitted 08/26/2015 Date Validated 09/O1/2015 httpsl/www.floridabLilding.orglpr/pr app dU.aspx?param=wGEVXQwtDquTluhTgK2p/o2bd3Rp/o2bp/o2bNco2fgOsPmbLDVuklgzgTipp/o2fpQ36HZQp/o3dp/o3d 1/5 6/9/2017 Florida Building Code Online i Date Pending FBC Ap�I Date Approved 09/07/2015 Summary of Products Go to Page Page 1/2 f� i FL* Model,Number or Name Description 17996.1 Series 202-20S Steel Door Series 202-20S Steel O.S. Door w/Vertical Slider Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17996 RO'C CAC EXR 202 20S Vertical Slider ASTM E330 Approved for use outside HVHZ:Yes plus5Ldf d Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure:+30/-30 12/03/2018 Other: Installation'Instructions FL17996 RO II ELIX0034 Rev A Series 202-20S SS.odf Verified By:.Robert J.Amoruso, PE FL PE No.49752 Created by Independent Third Party: Yes Evaluation Reports FL17Q96 Rn AE PER 1642 Rev3 415-0705 ss.odf Created by lIndependent Third Party: Yes 17996.2 Series 230 W9 Steel Door Series 230 W9 Steel O.S. Door w/Cottage Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17996 RO C CAC EXR 230 W9 Cottage ASTM E330 Approved for use outside HVHZ:Yes PIusS,ndf l { Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure:+30/-30 12/03/2018 Other: Installation Instructions FL17996 RO II ELIX0033 Rev A Series 230 W9 SS Ddf Verified By: Robert J.Amoruso, PE FL PE No.49752 Created by.IndependentThlyd Party: Yes Evaluation Reports { FL17996 RO AE PER 1642 Rev3 415-0705 ss.ndf Created by Independent Thi Party: Yes 17996.3 Series 402-14 Vinyl Steel Out-Swinging Regular Door- 14"xl4"Window Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17996 RO C CAC EXR 462-14 E330 olus5,Pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 09/14/2020 Design Pressure: +40/-40 Installation Instructions i Other: FL17996 RO II ELIX0050 RE-V-A OS MODEL 402-14 ss.odf Verified By: Robert J.Amoruso, PE FL PE No.49752 Created by,Independent Third Party: Yes Evaluation Reports i FL17996 RO AE PER 1953iRevla 415-0705 ss.odf Created by Independent Third Party: Yes 17996.4 Series 402-20S Vinyl Steel,Out-swinging Regular Door-20"slider window Limits of Use Certification Agency Cert&cate Approved for use in HVHZ: No FL17996 RO C CAC EXR 462-20S E330 oll,s5.odf Approved for use outside HVHZ:Yes Quality Assurance Contrat Expiration Date Impact Resistant:No 09/14/2020 Design Pressure: +40/-45 Installation Instructions Other: FL17996 RO H ELIX0051 REV-A OS MODEL 402-20S ss.odf Verified By: Robert J.Amoruso, PE FL PE No.49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 RO AE PER 1951 Revia 415-0705 ss.odf Created by Independent Tliird Party: Yes I'. 9 17996.5 Series 407 Vinyl Steel,Out-swinging Regular Door-Blank(no window) ((( Limits of Use Certification Agency Certificate 1 Approved for use in HVHZ:No FL17996 RO C CAC EXR 407 E330 olus5.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 09/14/2020 Design Pressure: +40/-45 Installation Instructions Other: FL17996 RO II ELIX0052 REV-A OS MODEL 407 ss.ndf Verified By: Robert J.Amoruso, PE FL PE No.49752 Created by Independent Third Party: Yes \ Evaluation Reports FL17996 RO AE PER 1951 Revia 415-0705 ss.odf Created by Independent Third Party:Yes I. I 17996.6 Series 430 W9 Vinyl Steel Out-swinging Ri gular Door-9-Cite Window(1'S" x 3'0") I, u httpsJ/www.floridabuilding.orglpr/pr app dtl.aspx?param=wGEVXQwtDquTluhTgK2%2bd3R%2b%2bN°/a2fl3gQsPmbLDVuk9zgTip%2fpQ36HZQ%3d%3d 215 1 i; 1 9 f 6/9/2017 Finrida Buildtng Code Online Limits of Use Certification^bcncy Certificate Approved for use in HVHZ:No FL17996 RO C CAC EXR 430-W9 E330 DlusS odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 09/14/2020Ii Design Pressure:+33/-40 Installation Instructions Other: FI 17996 RO H ELIX0053 REV-A OS MODEL 430-W9 ss.odf Verified By. Robert J. Amoruso, PE FL PE No.49752 Created by lindependentThir'd Party:Yes Evaluation Reports FL17996 Rn of PER 1951 Revla 415-0705 ss.odf Created.by Independent Third Party: Yes 17996.7 Series 6400 W9 Cottage Series 6400-W9 Non-Impact Inswing Painted Steel Door w/Storm Door Limits of Use Certification Agency Certifcate Approved for use in HVHZ:No FL17996 RO C CAC EXR 64bD E330 olusS,Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 09/16/2014 Design Pressure:+66/-56 Installation Instructions Other: FL17996 RO II ELIX0056 Rev-A IS MODEL 6400-W9 WITH. STORM DOOR ss.odf Verified By: Robert I.Amoruso,PE FL PE No.49752 Created by:Independent Third Party: Yes Evaluation Reports I FL17996 RO AE PER 1954 Rev2 415-0705 ss.odf Created by;,IndependentThird Party: Yes i 17996.8 Series 7500 Oval Series 7500 Non-Impact Inswing Vinyl Laminated Steel Door w/Adjustable Threshold i Limits of Use Certification Agency Certifcate 11 Approved for use in HVHZ:No FL17996 RO C CAC EXR 7500 Oval 21 adiustabie threshold Approved for use outside HVHZ:Yes E330 plus5:odf I Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure:+34/-50 09/17/2019 Other: Installation Instructions EL17996 RO II ELiX0055 Rev-A IS MODEL 7500 OVAL 21 WITH ADJUSTABLE THRFESHOLD ss.odf Verified By: Robert J.Amoruso, PE FL PE No.49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 RO AE PER 1955 Rev2 415-0705 ss.odf Created by Independent Third Party: Yes i 17996.9 Series 7500 Oval Series 7500 Non-Impact Inswing Vinyl Laminated Steel Door w/Storm Door and PVC Jambs Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17996 RO C CAC EXR 7500 Oval 23 E330 olusS.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 09/16/2019 Design Pressure:+50/-50 Installation Instructions Other: FL17996 RO iI ELIX0060 Rev-A IS MODEL STR 7500 23 OVAL WITH STORM DOOR ss.Ddf Verified By: Roberti. Amoruso, PE FL PE No.49752 Created by Independent T61rd Party: Yes Evaluation Reports FL17996 RO AE PER 1955 Rev2 415-0705 ss.Ddf Created by Independent Tiiird Party: Yes 17996.10 Series 8400 W9 Cottage Series 8400-W9 Non-Impact Oval Inswing Vinyl Laminated Steel Door'w/Storm Door Limits of Use Certification Agency Certificate Approved for use In HVHZ: No FL17996 RO C CAC EXR 8400 E330 nlus5.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 09/16/2019 Design Pressure:+50/-50 Installation Instructions Other: FL17996 RO II ELIX0057 Rev-A IS MODEL 8400-W9 OVAL WITH STORM DOOR ss.ndf� Verified By: Robert 3.Amoruso, PE FL PE No.49752 Created by Independent Third Party: Yes Evaluation Reports R-17996 RO AE PER I Rev2 415-0705 ss.odf Created by Independent Third Party:Yes 17996.11 Series 9000 Series 9000 Non-Impact Inswing Vinyl Laminated Steel Door W/Storm Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17996 RO C CAC EXR 9000 50 E330 olusS.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date htt J/www.fl�idabuildin or ps g. g/pripr app_dU.aspx7param=wGEVXQwtDquTluhTgK2%2bd3R%2b%2bN%2f"usrmULLJVUKgzgTip%2fpQ36HZQ%3d%3d 315 � 1 6/9/2017 Fldrida Building Code Online Impact Resistant:0 09/16/2019 Design Pressure: +50/-50 Installation Instructions Other: FL3799'A' RO'II E 0058 RevI A IS BLANK 9000 DOOR W. STORM DOOR' ss ndf Verified By:,Robert J.Amorus o, PE FL PE No.49752 Created by Independent Third Party:Yes Evaluation Reports FL17996 110l'AE PER 1954 Rev2 415-0705 ss.odf Created by Independent Third Party: Yes i 17996.12 Series 9400 Cottage Series 9400-W9 Non-Impact Inswing Vinyl Laminated Steel Door w/Storm Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17996 Rol!C CAC EXR 9460 E330 olus5.odf Approved for use outside HVHZ:Yes Quality Assurance Contrac Expiration Date Impact Resistant:No 09/16/2019 Design Pressure:+50/-50 Installation'Instructions Other: FL17996 1101,II ELIX0059 Rev-A IS MODEL 9400-W9 COTTAGE W. STORM DOOR ss.0df Verified By:,.Robert J.Amoruso, PE FL PE No.49752 Created by;Independent Third Party: Yes Evaluation Reports i FL17996 RO At PER 1954 Rev2 415-0705 ss.Ddf Created by Independent Third Party: Yes p 7 17996.13 Series AFIF7N Series AFIF7N Non-Impact IS Fiberglass Door 'Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17996 Rd C CAC EXR AFIF7N E330 DIus5.odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 09/14/2010 11I Design Pressure:+38/-38 Installation Instructions Other: FL17996 RO II EMOO40 AFIF7N-BFIF7N RevA SS.odf Verified By: Robert J.Amoruso, PE FL PE No.49752 Created by!Independent Third Party: Yes Ro Evaluation Reports FI17996 AE DER 1952 Rev2 415-0705 ss.pdf Created by,Independent Third Party: Yes 17996.14 Series AFOF7N Series AF0F7N Non-Impact OS Fiberglass.Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17996 RO C CAC EXR AFOF7N E330 alus5:ndf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 09/14/2019 Design Pressure:+38/-38 Installation Instructions q Other: Ft 17U96j RO II ELIX0042 AFOF7N-BFOF7N RevA ss odf Verified By: Robert J.Amoruso, PE FL PE No.49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 '0 AE PER 1952 Rev2 415-0705 ss odf Created by Independent Third Party:Yes 17996.15 Series AVIF7N Series AV07N Non-ImpactlS Steel Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:No Fl 17996 ROC CAC EXR AVIF7N E330 Dius5.0df Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 04/05/2020 I Design Pressure: +25/-25 Installation Instructions d Other: FL17996 RO II ELIX0047 AVIF7N-BVIF7N RevA ss.pdf Verified By: Robert J.Amoruso, PE FL PE No.49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 RO AE PER 1953 Rev2 415-0705 ss.odf Created by Independent Third Party: Yes 17996.16 Series AVOF7N Series AVOF7N Non-Impact OS Steel Doors Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL17996 RO C CAC EXR AVOF7N E330 olus5 odf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 04/06/2020 Design Pressure: +21/-21 Installation Instructionsi Other: FL17996 RO II EUX0048 AVOF7N-BVOF7N RevA ss Ddf Verified By: Robert J. Amoruso, PE FL PE No.49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 RO AE PER 1953 Rev2 415-0705 ss.ndf Created by Independent Third Party:Yes 17996.17 Series BFIF7N Series BFIF7N Non-ImpactiIS Fiberglass Door I https:/Avww.floridabuilding.org/pr/pr app d.aspx?param=wGE\IXQwtDquTluhTgK2%2bd3R°/alb%2bN%2fMosPmbLDVuk9zgTip%2fpQ36HZQ%3d%3d 4/5 I 619/2017 Florida Building Code Online Limits of Use • Certification j)I— cy Certificate Approved for use in HVHZ:No FL17996 RO I C CAC EXR 5FIF7N F330 DIUSS.Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 09/15/2019 Design Pressure:+38/-38 Installation Instructions Other: FL17996 RO'II ELIX0040 AFIF7N-BFIF7N RevA SS Ddf Verified By:,Robert 1.Amoruso,PE FL PE No.49752 Created by Independent Third Party: Yes Evaluation Reports 1, FL17996 RO:AE PER 1952 Rev2 415-0705 s5.0df Created by Independent Third Party: Yes [ 3 17996.18 Series BFIF7S Series BFIF7S Non-Impact ISI Fiberglass French Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17996 RO C CAC EXR BFIF7S E330 DlusS Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 09/15/2019, Design Pressure:+38/-38 Installation Instructions Other: F117Q96 RO II ELIX0046 BFIF7S RevA ss.odf Verified By: Robert].Amoruso,PE FL PE No. 49752 Created bylIndependentThird Party: Yes Evaluation Reports I FL17996 RO AE PER 1952 Rev2 415-0705_ss.0df Created byj�independent Third Party: Yes 17996.19 Series BFOF7N Series BFOF7N Non-Impact OS Fiberglass Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17996 R6 C CAC EXR BOOM E330 plus5 Ddf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 04/06/2020 1 Design Pressure: +30/-30 Installation Instructions u Other: FI 17996 Rh IT EI IX0042 AFOF7N-BFOF7N RevA ss.Ddf Verified By: Robert].Amoruso, PE FL PE No.49752 Created by'Independent Third Party: Yes Evaluation;Reports FLI 996 RO AE PER 1952 Rev2 415 0705 ss Ddf Created by Independent Third Party: Yes i 17996.20 Series BVI63S Series BVI63S Non-Impact Single Inswing Door w/Fixed l ite Insert and Outswing Storm Door Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17996 RO C CAC EXR BVI63S E330 plus5.adf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 12/17/2021 Design Pressure: +65/-65 Installation Instructions Other: FI 17996 RO II ELIX0061 BVI63S RevA ss odf Verified By: Robert].Amoruso, PE FL PE No.49752 Created by IndependentTliird Party: Yes Evaluation Reports FL17996 RO AE PER 2244 Rev2 415-0705 ss.Ddf Created by Independent Ttilyd Party: Yes Go to Page 110 Page 1/2 11� Sack PJext I d Contact Us;;2601 Dlalr Stone Road,Tallahassee FL 31399 Phone:BSO-487-1824 The State of Florida is an WEED employer.Copyright 2007-2013 State of Florida. ::Privacv Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275(li,Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However'emall addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick here.I f Product Approval Accepts: Credit Card Safe https./A ww.ficridabuilding.orgtpr/pr app dtl.aspx?param=wGEVXQwtDquTluhTgK2p/g2bd3Ra/a2bg/a2bN`/`l 8MOsPmbLDVukgzgTipp/*2fpQ36HZQ*/o3da/a3d 515 I r ELIXIR DOOR & METAL COO a MODEL 407 NON-IMPACT OUTSWING VINYL LAMINATED STEEL DOOR INSTALLATION ANCHORAGE DRAWING GENERAL NOTES: INSTALLATION NOTES: Or 1--•+ PRODUCT ANCHORAGE SHOWN HEREIN IS DESIGNED S.IN AREAS WHERE WNDSORNE DEBRIS PROTECTION 1.ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH S.MINIMUM FJNBEDMENTAND EDGE DISTANCE EXCLUDE U N �COMPLY WITH THE CURRENT EDITION OFTHE REQUIREMENTS EXIST.USE OF AN IMPACT PROTECTIVE ANCHOR LOCATION. WALL FINISHES.INCLUDING BUT NOT LIMITED TO O 0 11 JRIDA BUILDING CODE(FBC)EXCLUDING HIGH SYSTEM COMPLYING WITH THE FBC REQUIREMENTS FOR STUCCO,FOAM,BRICK VENEER AND SIDING. N x O _ _ VELOCITY.HURRICANE ZONE AND THE DESIGN WINDBORNE DEBRIS REGIONS IS MANDATORY FOR THE Z THE INSTALLATION ANCHORS AT THE SPACINGS SHOWN F-� O J PRESSURE(8)STATED HEREIN.- - - —PRODUCT - -- - - - --ARETHE MINIMUM NUMBER OF ANCHORS AND MAXIMUM G.INSTALLATION ANCHORS SHALL BE INSTALLED IN � Z O W SPACINGS TO BE USED FOR PRODUCT INSTALLATION ACCORDANCE WITH ANCHOR MANUFACTURER'S - _ L�-- -�_- ------ --- 0 0 6 es 1e.THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED 6.FRAME MATERIAU ALUMINUM ALLOY 60B3-T6 INSTALLATION INSTRUCTIONS AND ANCHORS SHALL 0 =C) UPON SIGNED AND SEALED TEST REPORT DALLAS DOOR PANEL MATERIAL.OB MIL VINYL LAMINATED 3.SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS W LASORATORIES,INC.044278 AND ASSOCIATED GALVANIZED STEEL015'SKIN W/URETHANE FOAM CORE WITH LOAD BEARING SHIM(S).MAXIMUM ALLOWABLE THAN THE MINIMUM STRENGTH SPECIFIED IN THE � [~7 O_j O N LABORATORY STAMPED DRAWINGS. SHIM SIZE OF 114INCH.SHIM WHERE SPACE OF 111E INCH 'ANCHOR SCHEDULE'THIS SHEET. U W F F r Q 7.DESIGNATIONS•X'STAND FOR THE FOLLOWING: OR GREATER OCCURS.SHIM(S)SHALL BE CONSTRUCTED q[7 a J Z 2.ADEQUACY OF THE EXISTING STRUCTURAL 2X FRAMING X:OPERABLE PANEL OF HIGH DENSITY PLASTIC OR BETTER. 7.INSTALLATION ANCHORS AND ASSOCIATED HARDWARE OR STEEL FRAMING AS A MAIN WIND FORCE RESISTING O:FIXED PANEL MUST BE MADE OF CORROSION RESISTANT MATERIAL W W OF- SYSTEM CAPABLE OF WITHSTANDING AND 4.ANCHORS FOR INSTALLATION INTO WOOD FRAMING OR OR HAVE CORROSION RESISTANT COATING. 09 Zw Z TRANSFERRING APPLIED PRODUCT LOADS TO THE 8.HARDWARE: 140A.MINIMUM STEEL FRAMING SHALL BE AS SHOWN IN P. O� FOUNDATION IS THE RESPONSIBILITY OF ENGINEER A. HALF HINGES:(4)6083-TB EXTRUDED ALUMINUM 'ANCHOR SCHEDULE' SHEET. O Zgz OR ARCHITECT OF RECORD. B. LATCH LOCK:KEYED N r, dj6p.1C. DEAD BOLT:SINGLE CYLINDER 3.1X AND 2X SUCKS(WHEN USED)SHALL BE DESIGNED AND �1 � gJS ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE 9.SEE SHEETI FOR DESIGN PRESSURE CHART. Q q C'Jig STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE o>z 2 • RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF aj :2 RECORD. 10 4.THE INSTALLATION DETAILS DESCRIBED HEREIN ARE a 1,21qq 3 GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS 9 FOR A SPECIFIC SITE.IF SITE CONDITIONS CAUSE W INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN,A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. ANCHORSCHEDULE DOORFRAME MANUFACTURER EMBEDMENT EDP ANCHORCAPACRIES DESIGN PRESSURE RATING(PSF) IMPACT RATING SUBSTRATE TYPE SIZE ANWOR DISTANCE WHERE WATER INFILTRATION WHERE WATER INFILTRATION TYPE SPECIFICATION (IN)IO ((M Irl to t3AS®ON REQUIREMENT IS NEEDED REQUIREMENT IS NOT NEEDED NONE SHEET MN.3 •• +40.0/-45.0 METALISTEEL ASNE B18.6.4 THREADS MN. KSI YIELD Robert J.Amoruso,P.E. TUBING 14 GA FM(Z-BAR) PAN HEAD NO.B PAST INSIDE 31W FL P.E.No.49762 MN. (TAPPINGSCREW) SURFACE OF STRNEGTH "b ••UNIT MUST BE INSTALLED BENEATH AN APPROVED OVERHANG �seE71r4' THICKNESS SUBSTRATE N .i t TABLE OF CONTENT ANSI B18.8.1 `s r er c (WOOD SCREW) 4WODYNTHAMNINAIM * R SHEET DESCRIPTION 2 VIUNG FIN(Z BAR) PAN HEAD NO.8 OR 1" 12" SPECIFIC GRAVITY OF 1 a �nN��. 1 GENERAL AND INSTALLATION NOTES FRAMASNE B18.6A 0.42. 2 ELEVATION, ANCHORING LAYOUT (TAPPING SCR Dlgitally signed by Robert 1 Amoruso 3 VERTICAL CROSS SECTIONS DN:cn=ProductDesign Group, 1)FOR WOOD OR TAPPING SCREWS IF SHITTWO S A CONCE384,DRLL 0.082'PLOT FIDLE(DR1LL SIZE 4b). au=PTC Product Design Group, 4 HORIZONTAL CROSS SECTIONS 21 EDGE DBTANCE MEASURED FROM EITHER SIDE OFANCHORTO EDGE OFSUBSTRATE emall=robert@ptc-corprnm,W15 Date 2015.08AS 09A9:56.WOO' n b tri m O 1 E 3511/16'MAX O.A to C z FRAME WIDTH 34 314'MAX. $H DOOR PANEL 10'MAX. WIDTH — - O.C.(TYP.) B D 3'MAX.(TYP.-+{ I+--— -�+—9'MAX(TYP:) -- -- 3 3 III o � 4 44 4'MAX(TYP.) N 0 - -- --- F F +-� z oWrN 4 --- --- -- -4---- --= — - ----- --- 10'MAX- - - — =— -- `�G X G LOCK ASSEMBLY(REGULAR DRIVE-IN) O.C.(TYP.) W � -m000 79 314- 78 3/4' - 4 4 IS LOCATED APPROX.38'ABOVE ____1_ �,�1r M 0 J vi MAX.O.A E E BOTTOM OF DOOR O LEAF AND THE DEAD rCi tat x p E DOOR 4 4 BOLT ASSEMBLY APPROX42'ABOVE x a� �w0 •ti r a HEIGHT 142' BOTTOM OF DOOR LEAF.SEE STRIKE O y [a a�a f HEIGHT DETAILS THIS SHEET "V a wo 0 c� o aPL. z ' O Zo c s Z�` g$ 3B' „vo� 4�M� O �o �rs�.f0 —�- HALF HINGES Wf �— Q A 0 R X 3/4'SCREWS SILL ANCHOR SPACING Ri m 38 MID.) SAME AS HEAD SPACING 3 3 ANCHOR LAYOUT ` a WERIOR VIEW W ELEVATION EXTERIOR VMW ANCHORING NOTES: r ! 1. MINIMUM NUMBER OF ANCHORS IN JAMBS IS 13. Robert J.Amoroso,P.E. #8 TAPPING SCREW. ANCHOR SPACING VARIES,BUT NOT TO EXCEED FL P.E.No.49752 I 118 x2112'WOOD 10'MAXIMUM O.C.I SCREW MUST BE OF Oigitaliysigned I SUFFICIENT LENGTH TO SCREW 2. MINIMUM NUMBER OF ANCHORS IN HEAD AND SILL by RobertJ. #8 x 1/2' I I PENETRATE(3)THREADS Amoroso SCREWS I MINIMUM BEYOND STEEL IS 7.ANCHOR SPACING VARIES,BUT NOT TO u �� I t DN:cn=RobertJ. I l ` TUBE EXCEED 10'MAXIMUM D.C. as�w..S t 1 / Y�tr .',,,,,mot-=Au--PTC,o, c�IIt� g a�PfC Product 'o1;T•}C0' beDeslgnGroup, ENTRY DOOR °"""�° emaikrobert@p ENTRY DOOR sue+ w STRIKE DETAIL STRIKE DETAIL C-carpcom,C=U WOODmAMESUBMATE mimirmusasuosrRATE Date:201548A5 0930A6-"Dw o � s 1"MIN.EMBEDMENT #8 WOOD SCREW m INSTALLATION ANCHOR 2X WOOD FRAME m (BY OTHERS) THREE(3)THREAD o 0 112'MIN. MIN.PENETRATION I e SEALANT TAPE TO BACK EDGE DIST. t18 TAPPING SCREW v W a SIDE OF MOUNTING FIN INSTALLATION ANCHOR SEALANT TAPE TO BACK 31W MIN. R SIDE OF MOUNTING FIN EDGE DIST. a — 114'MAX SHIM ---- - --� -- -- — G ' -- EXTERIOR INTERIOR 14 GA.MIN.SQUARE STEEL TUBING(BY w OTHERS) U N x - -- — - - - - O� W M EXTERIOR INTERIOR �— — W N >oa OJUx V7 VERTICAL SECTION "z a� z a B wx WOOD FRAME SUBSTRATE VERTICAL SECTION fir-- D STEEL TUBING SUBSTRATE O t7 18- a? w o�v 20 O � �og qy Q O -ja Law-0 n `�e W F � EXTERIOR INTERIOR EXTERIOR INTERIOR 14 GA.MIN.SQUARE 1/4'MAX SHIM STEEL TUBING(BY OTHERS) Robert J.Amoruso.P.E. SEALANT TAPE TO BACK FL P.E.No.49752 SIDE OF MOUNTING FIN lIT MIN• EDGE DIST. 31w MIN. Digitallysigned 2X WOOD FRAME SEALANT TAPE TO BACK f EDGE DIST. by Robard. (BY OTHERS) I SIDE OF MOUNTING FIN Amoroso 1'MIN.EMBEOMENT---�{ �+l°"� 'vo DN:ar-Roberti #8 TAPPING SCREW ;°;,;c Fr6t Am�so o 1{8 WOOD SCREW THREE(3)THREAD INSTALLATION ANCHOR 3 tt $ou=PfC ProduR INSTALLATION ANCHOR N =; MIN.PENETRATIONer�� Design Group, A VERTICAL SECTION +; ( FP emaWroc=Ut ccerp.com,cdl5 WOODFRAMHSUBSTRATE C VERTICAL SECTION Date:201548 5 STEEL TUBING SUBSTRATE 0 9:5a19_G4,01r r„ s J4n a N m MAX SHIM O 1l 4' 1/4'MAX SHIM p = I E 112'MIN.EDGE DIST. 1i2"MIN.EDGE DIST. v 8 a 2X WOOD FRAME (B WOOD FRAME Rs (BY OTHERS) (BY OTHERS) i� - — _ _ T_- --- -- - -- �-- 6 it8 WOOD SCREW --� ---�- - - - 8 WOOD SCREW—--- G ' - INSTALLATION ANCHOR INTERIOR INTERIOR INSTALLATION ANCHOR #8 X 3/4"SMS Q U N O 1"MIN, N X o EMBEDMENT 1'MIN. — --- - - o - - - EMBEDMENT i� -- Ff = SEALANT TAPE TO BACK EXTERIOR EXTERIOR SEALANT TAPE TO BACK o o G SIDE OF MOUNTING FINSIDE OF MOUNTING FIN w w 1= a o.N oz ?o F HORIZONTAL SECTION O � s E, HORIZONTAL SECTION 1YOODFRAMBSUBSTRATB O WOODFRAMESUBSIRATE A a o>§ R 0 1� a a ` I , 14 GA.MIN.SQUARE 14 GA MIN. STEEL TUBING(BY STEEL TUBING(BY 3/8'MIN.EDGE DIST. 3/B"MIN.EDGE DIST. OTHERS) OTHERS) INTERIOR INTERIOR #8 TAPPING SCREW IN TAPPING SCREW INSTALLATION ANCHOR #8 X 3I4'SMS INSTALLATION ANCHOR C�\ THREE(3)THREAD THREE N THREAD MIN.PENETRATION MIN.PENETRATION Robert J,Amoruso,P.E. SEALANT TAPE TO BACK EXTERIOR EXTERIOR FL P.E.No.49752 SIDE OF MOUNTING FIN SEALANT TAPE TO BACK i '•`'* "-78%, SIDE OF MOUNTING FIN ` 'yb�etOp�O'�S HORIZONTAL.SECTION DigitallysgnedbyRobertl. HORIZONTAL SECTION H STEELTUBWGSUHSTRATE Arnonso STEEL TUBING SUBSTRATE DN:ar-RobeRJ.Amoroso,o, ou=PfCPmduct Design Group, emaikmbertBptc-corycom,moils Date.2015.0&05 09:50:29.0V. ++ F