HomeMy WebLinkAboutProduct Approval File Copy
1317NW Florida Building Code Online
IN
AL
� 7
� 1 't_ tj/ _ram,^'�l`�l` �,' ,>..}! i•' � __ ��, ` " __ ___
BCIS Home Log In User Registration Hot Topics, Submit Surcharge Stats&Facts Publi cations, FBC Staff BCIS Site Map Links Search
rI`Olfur1 ProductApproval
" po'i_.,}r (A
USER:Public User
Product A—val Menu>Pmduct or Aooliwtion Soant>Application List>Application Detail
i+ I
FL# FL9555-113
Application Type Revision
Cade Version 2014
Application Status Approved
Comments
Archived
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S.KING ST.
FAYETTEVILLE,NC 28301
(910)483-0479 Fact 256
jstleby@unionc.or�iugating.com
I
Authorized Signature John Stieby
jsUeby@unloncorrugadng.cam
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Roof Deck `
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-HaHcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Yoosef Lavi,P.E. 1
Validation Checklist-Hardcopy Received
r
Certificate of Independence Q555 R3 CpI Certificatelndenendence odf
I
Referenced Standard and Year(of Standard) Standard Year
ASTM E1592 2001
FM 4470 1992
UL 580 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FLaScs p3 Enuiv TestEauivalent C1999 3T7 odf
FL9555 R3 Eouiv TestE4uiUalent C1999 8.61
Sections from the Code
f
hltps://www.floridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDgNOROQkZA5RE8EOgziUdl7kfspeFEUQhka/a3d ' 1/3
b
I
6/7/2017 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 03/23/2015
Date Validated 03/24/2015
Date Pending FBC Approval 03/29/2015
Date Approved 06/23/2015
i
Summa ry of Products
1
FL# Model,Number or Name Description
9555.1 5V Panel 29 ga.,24"wide,through fastened panel over wood supports
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9555 R3 II EvaluationReoortC1999 3.odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure:+N/A/-70.25 Evaluation Reports
Other: Uplift load of 70.25 psf @ support spacing of 24"o.c. FL9555 R3 AE EvaluationRecortC1999 3.odf
Created by Independent Third Party: Yes
9555.2 MasterRib Panel 26 ga„36"wide,through fastened panel over steel supports
Limits of Use Installation Instructions 1
Approved for use in HVHZ:No FL9555 R3 11 EvaluationReyortC1999 4.odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-47.2 Evaluation Reports
Other:Uplift load of 47.2 psf @ support spacing of 60"o.c. FL9555 R3 AE EvaluatlonRenortC1999 4.odf
FL9555 R3 AE LSC1999 4.odfI
Created by Independent Third Party:Yes
9555.3 MasterRib Panel 29 ga.,36"wide,through fastened panel over steel supports
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL9555 R3 11 G; valuationReoortl 1999 5.odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+27.1/-37.7 Evaluation Reports
Other: Design load of 27.1&-37.7 psf at support spacing of FL9555 R3 AE EvaluationRenortC1999 5.odF
48"o.c. FL9555 R3 AE LSC1999 S.odf
Created by Independent Third Party:Yes
9555.4 MasterRib Panel 29 ga.,36"wide,through fastened panel over wood supports
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9555 R3 TI EvaluatlonReoort-C1999 6.ndf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+27.1/-36.2 Evaluation Reports
Other: Design load of 27.1&-36.2 psf at support spacing of FL9555 R3 AE EvaluationReoortC1999 6,odF
48"o.c. FL9555 R3 AE LSC1999 6.odfI
Created by Independent Third Party.Yes
9555.5 MasterRib Panel 29 ga.,36"wide, through fastened panel over nom. 1"x 4"
wood supports
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9555 R3 III EvaluatlonReoorIC1999 7.odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant:N/A Created by In dependent Third Party: Yes
Design Pressure:+N/A/-13B.9 Evaluation Reports
Other: Uplift load of 138.9 psf @ support spacing of 24"o.c. FL9555 R3 AE EvaluationReoortC1999 7.odf
Created by Independent Third Party:Yes
9555.6 PBR Panel 26 ga.,36"wide,through fastened panel over steel supports
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9555 R3 Ti EvaluationReoortC1999 8,odF
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam IPE 62240
Impact Resistant.,N/A Created by Independent Third Party:Yes
Design Pressure-+N/A/-52.5 Evaluation Reports I
Other: Uplift load of 52.5 psf @ support spacing of 60.187" FL9555 R3 AE EvaluationlkeookC1999 B.ndf
O.C. Created by Independent Third Party:Yes
aadc
httpsY/www.foridabuilding.org/pr/pr app Otl.aspx?param=wGEVXQwU)gtvOROQkZA5RE8ECgziUd[7kfspeFEUQhk°/"3d 213
i
I�
i
6R/2817 Florida Building Code Online
a
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:950,487-1824
The State of Florida Is an AA/ffo employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibillty Statement::Refund Statement
Under Florida law,email addresses are public records.if you do not want your e-mall address released in response to a publictecords request,do not send eledmN_c
mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October.1,2012,licensees licensed under Chapter 455,F.S.must provide the Departrnent with an email address if they have
one.The emalls provided may be used for official communication with the licensee.However email addresses are public re ford.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to'the public To determt a if you are a licensee under Chapter
4S5,F.S.,please dick here.
Product Approval Accepts:
Credit Card
Safe
i
i
I'
I
I.
I
I
httpsJ/www.floridabLilding.orgfpr/pr app dtl.aspx7param=wGEVXQWtDgtvOROQkZA5RE8EOgziUdi7krspeF UQhk%3d 313
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
'26 GA.MASTERRIB PANEL,
OVER STEEL SUPPORTS
FLORIDA BUILDING CODE 5TH EDITION (2014)
FLORIDA PRODUCT APPROVAL
FL 9555.2-R3
STRUCTURAL COMPONENTS
ROOF DECK
Prepared For:
Union Corrugating Company !'
P.O.Box 229
Fayetteville,NC 28302
Telephone: (910)483-0479
Fax: (910)483-8897
I
Prepared By:
Bala Sockalingam,Ph.D.,P.E.
Florida Professional Engineer#62246
1216 N Lansing Ave.,Suite C
Tulsa,OK 74106
Telephone: (918)492-5992
FAX: (866)366-1543
I
I
This report consists of
Evaluation Report(2 Pages including cover)
��yf11111111j
Installation Details(1 Page) ,� �p,LIN(;q
%%yOG�N 41
S
:v•v 022A
i� :W=
Report No. C1999-4 OF
Date:3.20.2015 *J S'(FLO
P��
is,p,4• Q, l` �•
�� �•S I ON��`�
i
FL 9555.2-R3
C 1999-4
3.20.2015
Page 2 of 2
Manufacturer: Union Corrugating Company
Product Name: MasterRib Panel
Panel Description: 36"wide coverage with 3/4"high ribs.at 9"j o.c.
Materials: Minimum 26 ga., 80 ksi steel. Galvanized:coated steel (ASTM A653)
or Galvalum_e coated .steel (ASTM A79,) or painted steel (ASTM
A755).
Support Description: Min 16 ga.,50 ksi steel. (Must be designed by others)
Slope: 1/2:12 or greater in accordance with FBC 2014 Section 15.07.4.2
Design Uplift Pressure:_ 47.2 psf @ maximum support spacing of 60" o.c.
(Factor of Safety=2)
Support.Attachment: #12-14 x V long self drilling screws with washers
At end supports @ 3.5"-5.5"-3.5"o.c. across panel width
At intermediate supports @ 9"o.c. across panel width
Sidelap Attachment: '/4"-14 x 7/8" long SDS with washer @ 30'I O.C.
Test Standards: Roof assembly tested in accordance with ASTM E1592-01 `Test
Method for Structural.Performance of Sheet Metal Roof and Siding
Systems by Uniform Static Air Pressure' Difference' and FM 4470
Section 5.5 'Resistance to Foot Traffic'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each projec in accordance
with FBC 2014 Section .1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing; listed herei shall not be
exceeded. The design uplift pressure'for reduced supp rt spacing may
be computed using rational analysis prepared by a Florida Professional
Engineer or based on Union Corrugating load span table. This product
is not approved for use in the High Velocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
FBC 2014 Section 1505 and current approved roofing materials
directory for fire ratings of this product.
_ Supporting Documents: ASTM E1592 Test Reports
Farabaugh Engineering and Testing Inc
Project No.T163-06,Reporting Date 6/7/06
FM 4470 Test Report
ENCON Technology Inc
C1583-2,Reporting Date 7/24/08
1 V
oavm en clrtam er:
PANEL FASTENER SEE PANEL SIDELAP SIDELAP FASTENER as.
vw:: wm
® 9" O.C. DETAIL _ @ 30" O.C.
�9" O.C.--{ MASTERRIB \
INTERIOR SUPPORTS I PANEL S
MIN 16 GA. STEEL
(DESIGNED BY OTHERS)
i,
PANEL FASTENER ® SIDELAP FASTENER
3.5"-5.5"-3.5" O.C. 30" O.C.
�9" O.C.— { MASTERRIB
END SUPPORTS I PANEL
MIN 16 GA. STEEL
(DESIGNED BY OTHERS) �M
TYPICAL PANEL .INSTALLATION X-SECTION
U -'o
F fnU�
a � mZN
a zwn
N � Yea
MASTERRIB PANEL FASTENER SIDELAP FASTENER PANEL FASTENER ® Z
EL n�m
PAN ® 9" O.C. ® 30" O.C. 3.5"-5.5"-3.5" OX.
0
W
MAX 60" O.C. I L. Li
I x
(SEE LOAD SPAN TABLE FOR o a
MIN 16 GA. STEEL m o
ALLOWABLE LOADS AND SPANS) S
(DESIGNED BY OTHERS) m a sum
SECTION VIEW
Z eos
�K.
- - -- -- - - — -- --- GENERAL NOTES: --- - - - - - - - -- - -- - -- _—�3 Vz:
1. ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA N
MASTERRIB BUILDING CODE (FBC).
SIDELAP FASTENER PANEL 2. ROOF PANELS SHALL BE 26 GA. (t = 0.017"). EFFECTIVE COVERING WIDTH $ k
1/4"-14 SOS WITH OF PANEL = 36".
-- WASHER 30" O.C. — PANEL FASTENER 3. ROOF PANELS SHALL BE INSTALLED OVER STRUCTURE AS SPECIFIED ON THIS —
��}}12-14 x 1' LONG DRAWING.
$DS WITH WASHER 4,_REQUIRED_DESIGN WIND_LOA05 SHALL_BE DETERMINED EOR_E&CH PROJECT.
THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE DESIGN LOADS.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE,FLORIDA
MIN 16 GA. STEEL BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS.DRAWING & THE CODE, THE CODE SHALL CONTROL.
(DESIGNED BY OTHERS) 6. SUPPORTS MUST BE DESIGNED TO WITHSTAND'WIND LOADS AS REQUIRED
PANEL SIDELAP REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
7. PANELS MAY SPAN BETWEEN EAVE TO RIDGE SUPPORTS OR. RAKE TO RAKE
SUPPORTS, 999-4 V
SMELT 110.
1 UP 1