HomeMy WebLinkAboutProduct Approval (2) r File Cop
6/9/2017 Florida Building Code Online
- 1:�•:;il.l.i(.i i,1 4 _ li I ��. 4 t I _ •il ��[
;=i{, � ' ,� '`ems- c �,l(i �.�i'r c , I ,,• `!I�G�. f� :¢,_ _�i�i��ik�..
IL
BCIS Home i Log In User Registration ! Hot Topics i Submit Surrharge 1 Stats&Facts j Publications FBC Staf i BCIS Site Map I Links I Search
_ I Florida �.
Product Approval
Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL9555-R3
Application Type Revision
Code Version 2014
Application Status Approved i
Comments
�I
Archived
Product Manufacturer UNION CORRUGATING COMPANY
Address/Phone/Email 701 S. KING ST. i
FAYETTEVILLE, NC 28301
(910)483-0479 Ext256
jstieby@unioncorrugating.com
Authorized Signature John Stieby
jstieby@unioncorrugating.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Roof Deck
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalirigam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Yoosef Lavi, P.E.
` Validation Checklist-Hardcopy Received
Certificate of Independence FL9555 R3 COI CertificateIndependence.Ddf
I
Referenced.Standard and Year(of Standard) Standard Year
ASTM E1592 2001
FM 4470 1992
UL 560 1994
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL9555 R3 Equly TestEauivalent C199913T7.Ddf
FL9555 R3 Equiv TestEauivalent C199918_3df
I
Sections from the Code
I
https://www.floridabuilding.orgiprlpr app dd.aspx?param=wGEVXQwtDgtvOROQkZA5RE8EOciziUdlMspeFEUQhk%3d 113
602617 Florida Building Code Online
Product Approval Method Method 1 Option D
r
Date Submitted 03/23/2015
Date Validated 03/24/2015
Date Pending FBC Approval 03/29/2015
Date Approved 06/23/2015
Summary of Products
• 4
FL# Model,Number or Name Description
9555.1 5V Panel 29 ga., 24"wlIe,through fastened panel over wood supports
Limits of Use Installation.ilnstructions
Approved for use in HVHZ:No FL9555 R3 Its EvaluationRe DortC1999 3 odf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingarn PE 62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-70.25 Evaluation Reports
Other.Uplift load of 70.25 psf @ support spacing of 24"o.c. FL9555 R3 AE EvaluationReoortC1999 3.adf
Created by Independent Third]Party:Yes
- r
9555.2 MasterRib Panel 26 ga.,36"wide,through fastened panel over steel supports
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9555 R3 II, EvaluationReoo tC1999 4.pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalinga��11' PE 62240
Impact Resistant:N/A Created by Independent Third1 Party:Yes
Design Pressure:+N/A/-47.2 Evaluation Reports
,Other:Uplift load of 47.2 psf @'support spacing of 60"o.c. FL9555 113 AE EvaluationReportC1999 4.odf
FL9555 R3 At LSC1999 4.odf,
Created by Independent Thlydl Party:Yes
o i
9555.3 MasterRib Panel 29 ga.,36"while,through fastened panel over steel supports.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9555 R3 It Eva IuationReool C1999 S.pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant:N/A Created by Independent Third'Party:Yes
Design Pressure:+27.1/-37.7 Evaluation Reports
Other: Design load of 27.1&-37.7 psf at support spacing of FL9555 R3 AE EvaluationReDortC1999 S.odf
48"o.c. FL 9555 R3 AE LSC1999 5.pdf
Created by I�dependent Third Party: Yes
9555.4 MasterRib Pahel 29 ga:, 36"w de,through fastened panel over wood supports
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9555 R3 II EvaluationRe p IrtC1999 6,pdf
Approved for use outside HVHZ:Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant:N/A Created by Independent Third Party: Yes
Design Pressure:+27.1/-36.2 Evaluation Reports
Other:Design load of 27.1&-36.2 psf at support spacing of FL9555 R3 AE EvaluationRe ortC1999 6.pdf
48"o.c. FL9555 R3 AE LSC1999 6.pdf
Created by Independent Third Party:Yes
� r
9555.5 MasterRib Panel 29 ga., 36"wide,through fasti ned panel over nom. 1"x 4"
wood.supports
Limits of Use Installation Instructions qI
Approved for use in HVHZ:No FL9555 R3 II EvaluationReo rtC1999 Todf
Approved for use outside HVHZ:Yes Verified By:lBala Sockalingam PE 62240
Impact Resistant:N/A Created by Independent Thirb Party: Yes
Design Pressure:+N/A/-138.9 Eva luatio n Reports
Other:Uplift load of 138.9 psf @ support spacing of 24"o.c. FL9555 R3 AE EvaluationRe ortC1999 7 odf
Created by Independent Third Party:Yes
9555.6 PBR Panel 26 ga.,36"wide,through fas�ened panel over steel supports
Limits of Use Installation;Instructions
555 R3 II Eva uation a ortC1999 8.
Approved for use in HVHZ:No FL9555 I R o pdf
Approved for use outside HVHZ:Yes Verifled By: Bala Sockalingam PE 62240
de
impact Resistant:N/A Created by Tn pendent tY Third Par : Yes
Design Pressure:+N/A/-52.5 Evaluation Reports
Other:Uplift load of 52.5 psf @ support spacing of 60.187" FL9555 R3 AE EvaluationReportC1999 S.odf
O.C. Created by Independent Third Party: Yes
3act: NeXC
haps://www.floridabdiding.orgfpr/pr app dt4aspx?param=wGEVXQwtDgtvOROQkZA5RE8EOgziUdl7kfspeFEUQhk%3d 2J3
i
6/9/2017 Florida Building Code Online
Contact Us::2601 Blair Stone Road Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement;:AccessibliN Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.mi'ist provide the Department with an email address if they have
one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please dick here.
Product Approval Accepts:
Credit Card
Safe
'i
I .
i
i
httpsJ/www.floridabLilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgtvOROQkZA5RE8EOgziUdl7kfspeFEUQhk`/gad 313
I -
i
I
EVALUATION REPORT OF
UNION CORRUGATING COMPANY
'26 GA.MASTERRIB PANEL'
OVER STEEL SUPPORTS
FLORIDA BUILDING CODE 5TH EDITION (2014)
FLORIDA PRODUCT APPROVAL
FL 9555.2-R3
STRUCTURAL COMPONENTS
ROOF DECK
I
Prepared For:
Union Corrugating Company
P.O.Box 220
Fayetteville,NC 28302
Telephone: (910)483-0479
Fax: (910)483-8897
Prepared By:
Bala Sockalingam,Ph.D.,P.E.
Florida Professional Engineer#62240.
1216 N Lansing Ave.,Suite C
Tulsa,OK 74106
Telephone: (918)492-5992
FAX: (866)366-1543
i
This report consists of
Evaluation Report(2 Pages including cover)
\\I111111///
Installation Details (1 Page) ASE
F :W=
Report No. C19994 — �z
' fit G • —�
Date:3.20.2015
`3 .2G. 2G
i
FL 9555.2-R3
C 1999-4
3.20.2015
Page 2 of 2
Manufacturer: Union Corrugating Company
Product Name: MasterRib Panel
- Panel Description: 36" wide coverage with 3/4"high ribs at 91I O.C.
Materials: Minimum 26 ga., 80 ksi steel. Galvanized'coated steel (ASTM A653)
or Galvalume coated steel (ASTM A792) or painte steel (ASTM
A755).
Support Description: Min 16 ga.,50 ksi steel. (Must be designed by others) I
Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1 507.4.2
Design Uplift Pressure: 47.2 psf @ maximum support spacing of 6'0" O.C.
(Factor of Safety=2)
Support Attachment: #12-14 x V long self drilling screws with washers
At end supports @ 3.5"-5.5"-3.5" o.c. across panel width
At intermediate supports @ 9"o.c. across panel width
Sidelap Attachment: I/4"-14 x 7/8" long SDS with washer @ 30'i o.c.
Test Standards: Roof assembly tested in accordance with ASTM E1592-01 `Test
Method for Structural Performance of Steet Metal Roof and Siding
Systems by Uniform Static Air Pressure) Difference' and FM 4470
Section 5.5 `Resistance to Foot Traffic'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing I listed herein shall not be
exceeded. The design uplift pressure for reduced support spacing may
be computed using rational analysis prepared by a Florida Professional
Engineer or based on Union Corrugating load span table. This product
is not approved for use in the High Veiocity Hurricane Zone. Fire
classification is not within scope of this Evaluation Report. Refer to
- FBC 2014 Section 1505 and current approved roofing materials
directory for fire ratings of this product.
Supporting Documents: ASTM E1592 Test Reports
Farabaugh Engineering and Testing Inc
Project No.T163-06,Reporting Date 6/7/06
FM 4470 Test Report
ENCON Technology Inc
C1583-2,Reporting Date 7/24/08
I
11 • r •
on.»v en a:uw er:
PANEL FASTENER SEE PANEL SIDELAP SIDELAP FASTENER os
® 9" O.C.
DETAIL _ ® 30" O.C. own ovn
�9" O.C.�{ ///��� MASTERRIB
INTERIOR SUPPORTS I PANEL
s
MIN 16 GA. STEEL
(DESIGNED BY OTHERS)
u
n
PANEL FASTENER 0 SIDELAP FASTENER g
3.5"-5.5-3.5" O.C. 0 30" O.C.
�9" O.C.--{ MASTERRIB
END SUPPORTS I PANEL
MIN 16 GA. STEEL —r
(DESIGNED BY OTHERS) 6 to�
TYPICAL PANEL INSTALLATION X-SECTION Z wN.
O ¢ Ozc
a R O I
m
MASTERRIB PANEL FASTENER SIDELAP FASTENER PANEL FASTENER 0 a, of
PANEL 0 9" O.C. O 30" D.C. 3.5"-5.5"-3.5" D.C. " Z ��O
o Y
Lj
a
MAX 60" O.C. I IL
ALLOWABLE LOADS AND SPANS)(SEE LOAD SPAN TABLE FOR o n
MIN 16 GA. STEEL I w o
( ) m DESIGNED BY OTHERS _ �e
a m
SECTION VIEW W. �
-- - _ - - -- GENERAL NOTES - u z +.
1. ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA
MASTERRIB BUILDING CODE (FBC),
SIDELAP FASTENER PANEL 2. ROOF PANELS SHALL BE 26 GA. (t = 0.017"). EFFECTIVE COVERING WIDTH €
1/4"-14 SOS WITH FASTENER OF PANEL = 36".
PANEL
WASHER 0 30" O.C. 1NEL z 1" LONG 3. ROOF PANELS SHALL BE INSTALLED OVER STRUCTURE AS SPECIFIED ON THIS
DS WITH WASHER DRAWING.
_ 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT.
— -- - - THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN
WIND LOADS ARE GREATER THAN THE ALLOWABLE DESIGN LOADS.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
MIN 16 GA. STEEL BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
(DESIGNED BY OTHERS) 6REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
. SUPPORTS MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED
PANEL SIDELAP REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
7. PANELS MAY SPAN BETWEEN EAVE TO RIDGE SUPPORTS OR RAKE TO RAKE DRAW
SUPPORTS. 19 99-4
SHEET NO.
OF