Loading...
HomeMy WebLinkAboutProduct Approvals-underlaymentBusiness 0 Pr 8 • 4 e ® _..{R. BCIS Home Log In User Registration I Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search b a 4.oi Lb) Product Approval USER: Public User l.��csa'.�PcFirV+ Product Approval Menu > Product or Apolication Search > Application List > Application Detail c • FL # FL20876-R`/� 2 V ► 1+� Application Type Revision Code Version 2020 U d 1 0, Application Status Approved *Approved by DBPR. Approvals by DBPR sha view and ratified by the POC and/or the Commission If necessary�� OPV Comments Archived Product Manufacturer Address/Phone/Emall Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Evaluation Entity Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Dupont 5401 Jefferson Davis Highway Richmond, VA 23234 (812) 212-4429 melissa.s.grant@dupont.com Melissa Grant melissa.s.grant@dupont.com Melissa Grant P.O. Box 103 202 E. Washington Street Morris, IL 60450 (812) 212-4429 melissa.s.grant@dupont.com Roofing Underlayments A "IE 0�?ED`qFOYR BODE COMPLIANCE ST, LTB0CC01---'-1 IE COUNTY Evaluation Report from a Product Evaluation Entity Intertek Testing Services NA, Inc. Intertek Testing Services NA, Inc. - QA Entity 12/31/2023 Intertek Testing Services NA, Inc. Standard ASTM D226 Year 2009 Product Approval Method Method 1 Option C Date Submitted 01/27/2021 Date Validated 01/27/2021 Date Pending FBC Approval Date Approved 01/29/2021 Summary of Products FL # Modelr Number or Name Description 20876.1 Dupont Protec Underlayment 120,160, 200 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20876 R2 Ir K29385 Tyvek Protec Install Guide.pdf Approved for use outside HVHZ: Yes Verified By: Intertek Testing Services NA, Inc. Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: FL20876 R2 AE 2021-01-26 CCRR-1062.pdf 20876.2 Dupont Tyvek Underlayment Roof Protector Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL20876 R2 II SC00501 Tyvek Roof Protector Brochure.pdf Verified By: Intertek Testing Services NA, Inc. Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Design Pressure: N/A Evaluation Reports Other: FL20876 R2 AE 2021-01-26 CCRR-1087.pdf Bacl; Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Q iQht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement:: Refund Statemen Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida, Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: � lv e-- �a Credit Card Safe 4 Installation Information DuPont M Tyvek° P rotecTM Roofing Underlayments Installation Guidelines SYSTEM OVERVIEW Installation Guidelines Acceptable For Use With • DuPont' Tyvek' Protec" 120 • DuPont"" Protec"' 160 • DuPont' Tyvek* Prot ec"200 Specifications • Tyvek` Protec' is available in 10 square rolls: 48" x25071.2m x 76.2m (92.9mz), and 2 square rolls:48" x5071.2m x 15.2m (18.5 m2) • Tyvek' Protec" is for use on roofs with slopes >-2:12. • Tyvek' Protec" must be covered with the final roof cladding within: 3-months with Tyvek' Protec" 120 6-months with Tyvek* Protec" 160 or Tyvek' Protec'" 200 Tyvek Protec" should not be considered a final roofing system/primary water barrier. Tyvek' Protec" is a secondary layer applied over sheathing, under a primary roofing system as specified for the following: - Tyvek' Protec" 120 - asphalt shingles, metal or cedar roof cladding - Tyvek' Protec" 160 - asphalt shingles, tile, metal, cedar, or slate roof cladding - Tyvek` Protec" 200 - asphalt shingles, tile, metal, cedar, or slate roof cladding Building Code Compliance • Consult local building code and roof cladding manufacturer for use of underlayment. • Consult local building code and roof cladding manufacturer for underlayment edge and end overlap and fastening requirements that may differ from Tyvek' Protec" instructions. Follow the more restrictive requirements. • Where required by local building code, apply selfadhering waterproof underlayment as required by code according to manufacturer's instructions and Tyvek' Protec" for successive courses. • Tyvek` Protec" provides protection against leaks under all types of roof coverings identified by ICC-ES AC188. 4 0UPONTk Tyvek. • Tyvek' Protec" meets or exceeds the following code criteria and test protocols: - AC188 (Intertek CCRR 1062) - ASTM D226 types I & II - ASTM E108 - CAN/CSA A123.3 - CAN/CSA A220.1 Precautions and Safety • Apply Tyvek° Protec" taut and wrinkle -free. Do not stretch. • Do not apply Tyvek' Protec" over wet or frost -covered roof sheathing. • Caution should be taken when walking on Tyvek' Protec" until it has been fastened according to instructions. • Caution should be taken when walking on Tyvek® Protec' when it is wet or frost -covered. • Use fall protection when working on roof. Refer to OSHA safety regulations 29 CFR1926 subpart M. • Consult your local DuPont" Tyvek' Specialist for additional information. Preparation • Apply Tyvek' Protec" over a dry, smooth, clean and defect -free roof deck_ Tyvek' Protec' cannot be installed over existing roof cladding. • Tyvek` Protec" is a vapor barrier. Ensure that the space beneath the roof sheathing is properly ventilated before installing to avoid condensation problems. INSTALLATION 1. Lay courses of DuPont'' Tyvek' Protec" horizontally in "shingle style" fashion following the lap lines provided in 4" course overlaps and 6" end laps beginning along the eave edge. Offset end laps in successive courses by 6 feet. 2. When attaching DuPont- Tyvek' Protec"to the roof sheathing: When used under tile, slate, cedar and metal roof claddings, 1" diameter (min) metal or plastic (ring shank or smooth shank) cap -nails or cap -staples are required. - When used under asphalt or synthetic shingles, 1" diameter (min) metal or plastic cap -nails or capstaples are recommended. Un-capped staples or standard roofing nails may be used if shingles are installed within 36 hours (unless rain or high winds are expected). Use of un-capped fasteners may result in a risk of blow off or leakage around the fastener penetrations during a wind or rain event. - All anchoring must be performed flush to the roof and 90 degrees to the roof deck. 3. Install fasteners 12" on center (o.c) along course and. end over -laps and a single row 24" on center along the middle Line of the field. Use the printed pattern as a guide. 4. In high wind zones (at or above 100 mph per IRC R301.2), fasteners must be installed at all printed Locations on the Tyvek' Protec". It must be fastened using corrosion -resistant metal or plastic cap nails with a head diameter of at least 1" and a thickness of at least 32-gauge sheet metal. The cap -nail shank shall be a minimum of 12 gauge (0.105 inches) with a length to penetrate through the roof sheathing of a'minimum of 1/4 inch into the roof sheathing. 5. Apply Tyvek' Protec" with two layers on roofs with slopes between 2:12 and up to 4:12. Begin with a 26" undercourse strip parallel to the eave edge, and then cover with a full width sheet. Overlap successive sheets by 26". 6. Install Tyvek' Protec" over drip edges along eave edge and under drip edges along rake edges. Lap Tyvek' Protec" 8" (min) onto walls. 7. Line roof valleys with a sheet of Tyvek* Protec" prior to installing horizontal courses of Tyvek' Protec'. Lap the ends of horizontal Tyvek' Protec" courses over the valley sheet by 6". 8. At ridges and hips where ridge vents will not be applied, cross -lap Tyvek' Protec" from one roof plane onto the other by 6". For additional weather protection, apply a 24" wide sheet of Tyvek" Protec" across hips and ridges. Warranty Tyvek• Protec" is covered by a limited product replacement warranty: • Tyvek' Protec" 120: 30 years • Tyvek` Protec" 160: 40 years • Tyvek* Protec" 200: 50 years Warranty is offered by DuPont for builders, general contractors, or professional installers. This is not a consumer warranty. To obtain a copy of the warranty please visit www.tyvek.com/protec or call 1-800-448-9835. 4 OUPONT Tyvek. For more information about Protec,~ DuPont" Tyvek' Protec", please call1-800-448-9835 or ROOFING UNDERLAYMENTS visit us at www.tyvek.com/protec NOTICE: No freedom from any patent owned by DuPont or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer's use and for ensuring that Customers workplace and disposal practices are in compliance with applicable laws and other government enactments. The product shown in this literature may not be available for sale and/or available in all geographies where DuPont is represented. The claims made may not have been approved for use in all countries or regions. DuPont assumes no obligation or liability for the information in this document. References to'DUPont7 or the 'Company* mean the DuPont legal entity selling the products to Customer unless otherwise expressly noted. NO EXPRESS WARRANTIES ARE GIVEN EXCEPT FOR ANY APPLICABLE WRITTEN WARRANTIES SPECIFICALLY PROVIDED BY DUPONT. ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. The buyer assumes all risks as to the use of the material. Buyer's exclusive remedy or any claim (including without limitations, negligence, strict liability, or tart) shall be limited to the refund of the purchase price of the material. Failure to strictly adhere to any recommended procedures shalt release DuPont Specialty Products USA LLC or its affiliates, of all liability with respect to the materials or the use thereof. The information herein is not intended for use by non-professional designers, applicators or other persons who do not purchase or utilize this product in the normal course of their business. CAUTION: When cured, these products are combustible and will burn if ex.posed to open flame or sparks from high-energy sources Do not expose to temperatures above 2401F (116"0. Formore information. consult (Material) Safety Data Sheet ((IAISDS), call DuPont at 1.866-583-BLUE (2583) or contact your local building inspector. In an emergency, call 1-989-636-4400 in the U.S or 1.519-339-3711 in Canada. The blowing agent contained within this product can exhibit vapor flame limits under the right conditions. If specific operating conditions are such that concentrations of the blowing agent above the lower flammable limit can accumulate In areas with high relative humidity and In the presence of high-energy electrical discharges or other ignition sources, additional measures such as increased ventilation or coded electrical equipment (class one, division two) may be warranted.DO NOT SMOKE DURING USE DO NOT USE NEAR ANYOPEN FLAME OR ELECTRICAL SOURCE.OUTDOOR USE ONLY. INDOOR USE INCREASES LIKELIHOOD OF IGNITABLECGNDITIONSINSTASTIK-Quik Set Commercial Roofing Adhesive contains isoe/anato and a blowing agent. Read the label and (Material) Safety Data Sheet ((14)SDS) carefully before, use Wear gloves, and goggles or safety glasses. Provide_ adequate ventilation or swear proper respiratory protection. Contents under pressure. For outside use only. DuPont-, the DuPont Oval Logo, and all trademarks and service marks denoted with "', °' or Z are owned by affiliates of DuPont de Nemours, Inc unless otherwise noted rd 2020 DuPont 43-0100764-enNA-0220 CDP i- intertek Code Compliance Research Report Total Quality. Assured. CC R R-1062 DIVISION: 07 00 00 — THERMAL AND MOISTURE PROTECTION Section: 07 30 05 — Roofing Felt and Underlayment REPORT HOLDER: DuPont de Nemours, Inc. 1501 Larkin Center Drive Midland, MI 48674 (989)638-4318 www.dupont.com/building REPORT SUBJECT: Dupont— Tyvek® ProtecTM' 120, 160, and 200 Roofing Underlayments 1.0 SCOPE OF EVALUATION This Research Report addresses compliance with the following Codes: 2018, 2015, and 2012 International Building Code® (IBC) 2018, 2015, and 2012 International Residential Code® (IRC) 2020 Florida Building Code (FBC) — See Section 8.1 2.0 USES DupontTM Tyvek® ProtecTM' 120, 160,. and 200 underlayments are used in the field of the roof as an alternative to the ASTM D226, Type I and Type II, roof underlayments specified in Chapter 15 of the IBC and Chapter 9 of the IRC. The underlayments may be used in areas of the roof required by IBC Section 1507 or IRC Section R905 to have an ice barrier roof underlayment, when installed as noted in Section 4.2. The underlayments may be used as components of classified assemblies when installed as described in this report. The underlayments have been evaluated for the properties as listed in Table 1. 3.0 DESCRIPTION Dupont'" Tyvekm Protec'" 120 is a mechanically .attached synthetic underlayment comprised of an embossed non- woven top scrim and a woven bottom scrim with a polymeric laminated facer. The underlayment has an overall weight of 2.25 pounds per 100 square feet, and it is available in rolls 48 inches wide by 250 feet long. Issue Date: 05-25-2016 Revision Date: 01-26-2021 Renewal Date: 01-31-2022 Dupont'" Tyvek® Protec'°- 160 is a mechanically attached synthetic underlayment comprised of an embossed non- woven top scrim and a woven bottom scrim with a polymeric laminated facer. The underlayment has an overall weight of 3.27 pounds per 100 square feet, and it is available in rolls 48 inches wide by 250 feet long. DupontTM' Tyvek" ProtecTM' 200 is a mechanically attached synthetic underlayment comprised of an embossed non- woven top scrim and a woven bottom scrim with a polymeric laminated facer. The underlayment has an overall weight of 3.58 pounds per 100 square feet, and it is available in rolls 48 inches wide by 250 feet long. 4.0 INSTALLATION 4.1 General: Installation of the underlayments must comply with the applicable Code, this report, and the report holder's published installation instructions. The underlayments must be installed in accordance with the subsections of IBC Section 1507 and IRC Section R905 applicable to the roof covering being installed. The underlayments must be laid with the print side up, with laps as required by the applicable Code, evaluation report, or manufacturer's instructions, whichever is more restrictive. The roof covering may be installed immediately following the underlayment application and the underlayment must be covered within the time designated in the report holder's published installation instructions. 4.2 Ice Barrier: In areas of the roof required by IBC Section 1507 or IRC Section R905 to have an ice barrier, two layers of DupontTM' Tyvek° ProtecTM' 120, 160, or 200 underlayment, solidly cemented together with a low solvent based roofing cement complying with ASTM D4586 Type 1 (asbestos free), may be used provided the ice barrier extends up the roof a minimum distance of 24 inches inside the interior wall line of the building. The underlayment installed in the field of the roof must overlap the ice barrier. (a 545 E. Algonquin Road • Arlington Heights * Illinois • 60005 intertek.com/building Intertek PCA-101 Version: 21 December 2017 5Fr-CCRR-OP-40b on Code Compliance Research Report CCRR-1062 4.3 Fire Classification: The underlayments may be used as a component of a classified roof assembly when specifically recognized as such in a listing approved by the Code official. The underlayments may also be used as an alternative to the underlayments specified in the Code for roof coverings permitted under the Exceptions to IBC Section 1505.2 and IRC Section R902.1 and may be used where non -classified roofing is permitted in IBC Section 1505.5. 5.0 CONDITIONS OF USE The underlayments described in this Research Report comply with, or are suitable alternatives to, what is specified in those Codes listed in Sections 1.0 and 2.0 of this report, subject to the following conditions: 5.1 Installation must comply with this Research Report, the manufacturer's published installation instructions, and the applicable Code. In the event of a conflict between the manufacturer's instructions and this report, this report governs. 5.2 Installation is limited to use with approved mechanically attached roof covering systems. 5.3 Installation is limited to roof systems that do not involve hot asphalt or coal -tar pitch. 5.4 Installation is limited to roofs with a slope of 2:12 (17%) or greater. 5.5 Attic ventilation must be provided in accordance with the applicable Code since there are no requirements to evaluate vapor permeability of the underlayment. 5.6 The underlayments are manufactured under a quality control program with inspections by Intertek Testing Services NA Inc. 6.0 SUPPORTING EVIDENCE 6.1 Reports of tests in accordance with ASTM E108. 6.2 Data in accordance with ICC-ES Acceptance Criteria for Roof Underlayments (AC188), dated . February 2012 (editorially revised December 2015). 6.3 Intertek Listing Report titled "DuPont Synthetic Roofing Underlayments". 7.0 IDENTIFICATION Page 2 of 3 The DupontTM Tyvek® ProtecTM 120, 160 and 200 underlayments are imprinted with the report holder's name, the Intertek Mark, and the Code Compliance Research Report number (CCRR-1062). Each roll of the product is also labeled with installation instructions, roll dimensions and weight. CODE COAOUMCE (a. Intertek 8.0 OTHER CODES 8.1 Florida Building Code: 8.1.1 Scope of the Evaluation: Dupont'"" Tyvek® ProtecTM' 120, 160, and 200 underlayments were evaluated for compliance with the 2020 Florida Building Code — Building and the 2020 Florida Building Code —Residential. 8.1.2 Conclusion: The DupontTM Tyvek® ProteC" 120, 160, and 200 underlayments described in Section 2.0 to 7.0 of this report comply with the 2020 Florida Building Code — Building and the 2020 Florida Building Code — Residential, including High -velocity Hurricane Zones (HVHZ), subject to the following conditions: The underlayment must be installed in accordance with the provisions noted in Sections 2.0 through 8.0 of this report, Sections 1507 and 1518 of the Florida Building Code — Building, and Section R905 of the Florida Building Code — Residential Intertek is an approved evaluation entity and quality assurance entity pursuant to Florida Statute 553.842 — Product Evaluation and Approval Use of the underlayments in discontinuous roof tile systems is outside the scope of this report 9.0 CODE COMPLIANCE RESEARCH REPORT USE 9.1 Approval of building products and/or materials can only be granted by a building official having legal authority in the specific jurisdiction where approval is sought. 9.2 Code Compliance Research Reports shall not be used in any manner that implies an endorsement of the product by Intertek Testing. 9.3 Reference to the httos://bpdirectory.intertek.com is recommended to ascertain the current version and status of this report. 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 O intertek.com/building Intertek PCA401 Version: 21 December 2017 SFT-CCRR-OP-40b i- Code Compliance Research Report CCRR-1062 TABLE 1— PROPERTIES EVALUATED Page 3 of 3 PROPERTY IBC SECTION' J IRC SECTION' FBC (BUILDING) FBC (RESIDENTIAL) Physical Properties 104.11, 1506, and 1507 R104.11, R904, and R905 104.11,1507, and 1518.4 R904 and R905 Fire Classification 1505 R902.1 1505 R902 Ice Barrier 1507 R905 N/A N/A 'Referenced sections apply to 20181BC and IRC This Code Compliance Research Report ("Report') is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. (a 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building Intertek PCA-101 Version: 21 December 2017 SFr-CCRR-OP-40b