HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENT DECKING SEAM TAPE 7/13/2021 Florida Building Code Online
v •• z v � r
0 _
BCIS Home I Login User Registration I Hot Topics Submit Surcharge Stats&Facts I Publications Contact Us BQS Site Map Links Search l
Flolida
r r�i )Product Approval
Io USER:Public User
Product Approval Menu>Product or Aoplicatton Search>Aoolication List>Application Detail
FL# FL2569-1122
Application Type Revision
Code Version 2020
Application Status Approved
Comments 1 Y File,
Archived JL'lie, Copy
Product Manufacturer Soprema,Inc. (Canada) 9k6EDVF�14
Address/Phone/Email 1640 rue Haggarty
Drummondville,NON-US o00000DE COMPLIANCE
(810)478-2400
memathieu@soprema.ca ST. LUCIE COUNTY
Authorized Signature Marc-Etienne Mathieu �BOCC -41��
memathieu@soprema.ca 1
Technical Representative Marc-Etienne Mathieu
Address/Phone/Email 1688 Jean-Berchmans-Michaud
Drummondville,NON-US 00000
(819)478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative Jean-Francois Cote,Ph.D.
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert]. M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W.Knezevich,PE
El Validation Checklist-Hardcopy Received
Certificate of Independence FL2569 R22 COI 2021 01 COI NIEMINEN.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2015
ASTM D4601 2012
ASTM D4798 2011
FM 4474 2011
FRSA/TRI Sixth Edition 2018
TAS 103 2020
UL1897 2015
https://www.floridabuilding.org/pr/pr app_dU.aspx?param=wGEVXQwtDgsKQFEnckBl08Erx1Ud3xYir7amGvvoArggkU4EylLatg%a3d%3d 1/2
7/13/2021 Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/19/2021
Date Validated 04/19/2021
Date Pending FBC Approval 04/26/2021
Date Approved 06/08/2021
Summary of Products
FL# Model,Number or Name Description
2569.1 Soprema Roof Underlayments for Self adhering roof underlayments
use in FBC HVHZ jurisdictions
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL2569 R22 II 2021 04 19 FINAL ER SOPREMA HVHZ FL2569-
Approved for use outside HVHZ:No R22.pd
Impact Resistant:N/A Verified By: Robert Nieminen PE-59166
Design Pressure:N/A Created by Independent Third Party:Yes
Other:Refer to ER Section 5 for Limits of Use. Evaluation Reports
FL2569 R22 AE 2021 04 19 FINAL ER SOPREMA HVHZ FL2569-
R22 d
Created by Independent Third Party:Yes
2569.2 Soprema Roof Underlayments for Self adhering roof underlayments
use in FBC non-HVHZ jurisdictions
Limits of Use Installation Instructions
Approved for use In HVHZ:No FL2569 R22 II 2021 04 19 FINAL ER SOPREMA NON-
Approved for use outside HVHZ:Yes HVHZ FL2569-R22.pdf
Impact Resistant:N/A Verified By: Robert Nieminen,P.E.PE-59166
Design Pressure:+N/A/-150 Created by Independent Third Party:Yes
Other:1.)Refer to ER Section 5 for Limits of Use.2.) Evaluation Reports
The design pressure noted herein pertains to FL2569 R22 AE 2021 04 19 FINAL ER SOPREMA NOW
underlayment systems used beneath adhesive-set tile HVHZ FL2569-R22.pdf
systems.Refer to ER Section 5.8.3 for details. Created by Independent Third Party:Yes
Bact< Ne:ct
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyrioht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.-Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which an be made available to the public.To determine if you are a licensee under Chapter 455,F.S,please click b&re.
Product Approval Accepts:
® ¢Cttzl M
Credit Card
Safe
httpsJ/www.floridabuilding.org/pr/pr app_ d.aspx?param=wGEVXQwtDgsKQFEnckBlOBErxl Ud3xYlr7amGvvoArggkU4EylLatq%3d%3d 2/2
NEMO I etc.
Certificate of Authorization#32455
353 Christian Street,Unit#13
Oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
SOPREMA,Inc. Evaluation Report 3m-SOPC-2I-FBCER.A
1640 rue Haggerty FL2569-1122(HVHZ)
Drummondville,Quebec.12C 5138 Canada Date of Issuance:04/19/2021
(919)478-2400
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State:of Florida.The documentation submitted has been reviewed by Robert Nieminen,P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the Ph Edition (2020) Florida Building Code, High Velocity
Hurricane Zone sections noted herein.
DESCRIPTION: SOPREMA Roof Underlayments for use in FBC HVHZ jurisdictions -
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality
Assurance or production facility location(s) changes,or Code provisions that relate to the product(s) change. Acceptance of
our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s),
the Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a complete review of its Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval Number(FL#) preceded by the words"NEMO I etc.Evaluated" may be displayed
in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
-y�J �^fir�o-34SE9J:�Z
— - 0=-
Robert J.M.Nieminen,P.E. �!,�F•=c ?f 4' The facsimile seal appearing was authorized by Robert Nleminen,P.E.
Florida Registration No.59166,Florida DCA ANE1983 ".'_'s�iSii ; �``'' on C4/19/2021.This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project.on
which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that
purpose.
m2019 NEMO ETC,LLC
NNEMOletc.
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: U n d erl ayme nt
Compliance Statement: SOPREMA Roof Underlayments,as produced by SOPREMA,Inc.,have demonstrated compliance with
the following sections of the 711 Edition (2020) Florida Building Code, High Velocity Hurricane Zone through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions
of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
TAS 110 Material standard ASTM D1970 2015
TAS 110 Material standard ASTM D4601 2012
TAS S10 Material standard TAS 103 2020
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
En_ tity Examination Reference Date
ERD(TST6049) TAS 103(MS) S43530.02.14-1-R1 02/21/2014
ERD(TST6049) ASTM D1970(QC) S44870.04.14-3 04/02/2014
ERD(TST6049) ASTM D1970(OH) S44870.04.14-1 04/10/2014
ERD(TST6049) ASTM D1970(MS) S44870.04.14-4 04/10/2014
ERD(TST6049) ASTM D1970(OH) S40540.10.14 10/31/2014
ERD(TST6049) Tensile Adhesion/Long Term Aging SOPC-SC7645.02.15 02/13/2015
ERD(TST6049) ASTM D4798 SOPC-SC8520.04.14 04/27/2015
NEMO(TST6049) ASTM D1970/TAS 110(QC) SOPC-SC8970.08.15-RI 04/25/2018
NEMO(TST6049) Tile Slippage 4S-SOPC-18-002.09.18 09/21/2018
NEMO(TST6049) ASTM D4601(MS) 4q-SOP-I9-SSMBB-01.A 03/11/2019
NEMO(TST6049) ASTM D4601(OH) 4q-SOP-I9-SSMBB-01.B 03/11/2019
NEMO(TST6049) ASTM D4798/1)1970(OH&MS) 4S-SOPC-18-002.05.19.A 05/31/2019
NEMO(TST6049) Tensile Adhesion/Long Term Aging 4p-DOW-I9-SSLAP-01.A.R2 02/10/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 41-SOPC-I9-SSUDL-04.A 03/12/2020
NEMO(TST6049) Peel adhesion(existing underlayments) 4j-SOPC-20-SSUDL-01.A 01/07/2021
NEMO(TST6049) ASTM D1970(MS) 4j-SOPC-2I-SSUDL-01.A 04/19/2021
PRI(TST5878) ASTM D1970(MS) SOF-064-02-01 12/03/2013
Soprema,Inc.(PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015
UL,LLC(QUA9625) Quality Control MLA File No.R16814 12/10/2015
UL,LLC(QUA9625) Quality Control MLA File No.R27605 05/08/2019
UL,LLC(QUA9625) Quality Control Service Confirmation 06/29/2020
UL,LLC(QUA9625) Quality Control Florida BCIS Current
4. PRODUCT DESCRIPTION:
Product Material Standard Plant(s) Description
4.1 LASTOBOND TU HT ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced,SBS
TAS 103 modified bitumen roof underlayment
4.2 Tri-Built S/A HT TU ASTM D1970 and Gulfport,MS self-adhering,non-woven polyester fabric surfaced,SBS
Underlayment TAS 103 modified bitumen roof underlayment
4.3 LASTOBOND Shield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified
bitumen roof underlayment available in two widths;36 and
45 inch
4.4 RESISTO SA SMOOTH PLY 40 ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified
bitumen roof underlayment
NEMO ETC,LLC. Evaluation Report 3m-SOPC-2148CER.A
Certificate of Authorization#32455 7-EDITION(2020)FBC HVHZ EVALUATION F1.2569-1122(HVHZ)
SOPREMA Roof Underlayments Revision 0:04/19/2021
Page 2 of 7
III
ONEMOletc.
i
Product Material Standard Plant(s) Description
4.5 LASTOBOND Shield HT ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof underlayment
4.6 LASTOBOND Pro HT-N ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,SBS modified
bitumen roof underlayment available in two widths;36 and
45 inch
4.7 LASTOBOND Pro HT-S ASTM.D1970 Drummondville;QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof-underfayment
4.8 EnviroShield ASTM D1970 Drummondville,QC self-adhering,woven polyethylene surfaced,high
temperature,SBS modified bitumen roof underlayment
4.9 LASTOBOND Eco ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
Gulfport,MS modified bitumen roof underlayment
Wadsworth,OH
4.10 LASTOBOND Smooth Seal HT ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,SBS
Wadsworth,OH modified bitumen roof underlayment
4.11 Tri-Built Smooth HT S/A ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,SBS
Underlayment Wadsworth,OH modified bitumen roof underlayment
4.12 PrimeSource Grip-Rite ASTM D1970 Gulfport,MS self-adhering,glass-mat reinforced,film-surfaced,SBS
Smooth Seal HT Wadsworth,OH modified bitumen roof underlayment
4.13 RESISTO LB1236 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
Gulfport,MS modified bitumen roof underlayment
Wadsworth,OH
4.14 TRI-BUILT Sand-R SA Shingle ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
Underlayment Gulfport,M5 modified bitumen roof underlayment
Wadsworth,OH
4.15 PrimeSource Grip-Rite Eave ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
&Valley Protector Gulfport,MS modified bitumen roof underlayment
Wadsworth,OH
4.16 SRS TopShield ICE&WATER ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
DEFENDER Gulfport,MS modified bitumen roof underlayment
Wadsworth,OH
4.17 RESISTO LB1244 ASTM D1970 Drummondville,QC self-adhering,glass-mat reinforced,sand-surfaced,SBS
Gulfport,MS modified bitumen roof underlayment
Wadsworth,OH
4.18 MODIFIED SOPRA-G ASTM D4601,Type II Gulfport,MS Fiberglass reinforced,SBS modified asphaltic base sheet
Wadsworth,OH
LIMITATIONS:5.
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are, in any way,the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance
unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC Non-High Velocity Hurricane Zone jurisdictions(i.e.,outside of Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance
with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam
plastic insulation.
MEMO ETC,U.C. Evaluation Report 3m-SOPC-2I-FBCER.A
Certlflcate of Authorization#32455 7-EDITION(2020)FBC HVHZ EVALUATION F1.2569-1122(HVHZ)
SOPREMA Roof Unciddayments Revision 0:04/19/2021
Page 3 of 7
NMEMO I etc.
5.5 SOPREMA Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1:.ROOF COVER OPTIONS ,
FBC Section: TA5110(510), TAS 110(511), RAS 133 TAS 110(512) RAS 130
RA5115 RAS 128,119&120
Clay and Concrete Tile
Underlayment Asphalt Slate or Slate-
y Shingles Mechanical Adhesive- Metal Type Shingles Wood
Attach Set
LASTOBOND TU HT,Tri-Built S/A HT TU Yes
Underlayment Yes Yes See 5.6.1 Yes Yes Yes
LASTOBOND Shield,Pro HT-N,RESISTO SA Yes No No Yes Yes Yes
SMOOTH PLY 40
LASTOBOND Shield HT,Pro HT-S Yes No No Yes Yes Yes
EnviroShield Yes No No Yes Yes Yes
LASTOBOND ECO,RESISTO LB1236,TRI-
BUILT Sand-R SA Shingle Underlayment,
Grip-Rite Eave&Valley Protector, Yes No No No Yes Yes
TopShield ICE&WATER DEFENDER,
RESISTO LB1244
LASTOBOND Smooth Seal HT,Tri-Built
Smooth HT S/A Underlayment,Grip-Rite Yes No No Yes Yes Yes
Smooth Seal HT
5.6.1 Adhesive-set tile is limited to use of the following underlayment/tile-adhesive combinations.
TABLE 1A:ALLOWABLE UNUERLAYMENT TILE-ADHESIVE COMBINATION51
Underlayment Adhesive Florida Product Approval
LASTOBOND TU HT,Tri-Built S/A HT TU Dupont"Tile Bond`"Roof Tile Adhesive" FL22525
Underlayment ICP Adhesives and Sealants"Polyset°AH-160" NOA 20-1124.07
5.7 Allowable Substrates:
TABLE 2:•SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates(designed to meet wind loads for project)
Underlayment Application
Type Primer Material(s)
LASTOBOND Shield,LASTOBOND Pro HT-N, Deck ASTM D41 structural concrete
RESISTO SA SMOOTH PLY 40,LASTOBOND Dens Deck Prime or SECUROCK
Shield HT,LASTOBOND Pro HT-S, Insulation (Optional)'Elastocol Stick Zero Gypsum-Fiber Roof Board
EnviroShield,LASTOBOND TU HT,Tri-Built S/A
HTTU Underlayment;LASTOBOND ECO, self-
RESISTO LB1236,TRI-BUILT Sand-R SA Shingle adhering
Underlayment,Grip-Rite Eave&Valley
Protector,TopShield ICE&WATER Base Sheet (Optional)Elastocol Stick Zero ASTM D226,Type II felt
DEFENDER,RESISTO LB1244,LASTOBOND
Smooth Seal HT,Tri-Built Smooth HT S/A
Underlayment or Grip-Rite Smooth Seal HT
1 Refer to Tile Manufacturers or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,U.C. Evaluation Report 3m-SOPC-2I-FBCER.A
Certificate ojAuthorhation#32455 7TH EDITION(2020)FBC HVHZ EVALUATION FL2569-R22(HVHZ)
SOPREMA Roof Underlayments Revision 0:04/19/2021
Page 4 of 7
3 �
ONEMOletc.
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application Substrates(designed to meet wind loads for project)
Type Primer Material(s)
LASTOBOND TU HT,Tri-Built S/A HT TU
Underlayment,RESISTO LB1236,TRI-BUILT self- Existing Existing sand-surfaced,glass-fiber
Sand-R SA Shingle Underlayment,Grip-Rite adhering substrate RESISTO EXTERIOR PRIMER surfaced,mineral-surfaced or
Eave&Valley Protector or TopShield ICE& film-surfaced roof underlayment
WATER DEFENDER
•Final acceptance of any existing substrate In a reroof(Lear-offJ installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a
question arise as to the sultability of an existing substrate to receive LASTOBOND TU HT,Tri-Built S/A HTTIJ Underlayment RESISTO L81236,TRI-BUILT Sand-RSA
Shingle Underloyment Grip-Rite Eave&Valley Protector or TopShield ICE&WATER DEFENDER self-adhering underlayments,contact RESISTO technical support.
5.8 Attachment Limitations:
Refer to Section 6
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover Maximum
Installation Type Exposure(days)
LASTOBOND Eco,RESISTO LB1236,TRI-BUILT Sand-RSA Shingle Underlayment,Grip-Rite Mechanically attached 30
Eave&Valley Protector,TopShield ICE&WATER DEFENDER or RESISTO LB1244
LASTOBOND Shield,LASTOBOND Pro HT-N,RESISTO SA SMOOTH PLY 40,LASTOBOND Shield
HT,LASTOBOND Pro HT-S,EnviroShield,LASTOBOND Smooth Seal HT,Tri-Built Smooth HT Mechanically attached 90
S/A Underlayment or Grip-Rite Smooth Seal HT
LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment Mechanically attached or 180
adhesive-set tile roof system
5.10 Tile Slippage Limitations:When loading roof tiles on the underlayment in direct-deck tile•roof assemblies,the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4:TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Flat Max.10-tile stack 6:12
Lugged Max.10-tile stack 5:12
Double-tile stacking method,as shown below 6:12
LASTOBOND TU HT,Tri-
Built S/A HT TU
Underlayment Lugged
NEMO ETC,U.C. Evaluation Report 3m-SOPC-2I-FBCER.A
Certificate of Authorization#32455 7-EDITION(2020)FBC HVHZ EVALUATION FL2569-RZ2(HVHZ)
SOPREMA Roof Underlayments Revision 0:04/19/2021
Page 5 of 7
NNEMOletc.
6.1 SOPREMA Roof Underlayments shall be installed in accordance with SOPREMA published installation instructions subject to-
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application,and prime the substrate(if applicable).
6.3 Approved Assemblies:
6.3.1 Deck Type 1: Wood,Non-Insulated
Deck Description: Min.19/32"plywood or wood plank
System Type E: Base sheet mechanically fastened to deck;underlayment adhered to base sheet
Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap,mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6-inch o.c.at the lap-edges and 12-inch o.c.
in a staggered grid-pattern between the overlaps.
Cap Ply: LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment,self-adhering and back-nailed max.12-inch
o.c.using FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5).
Surfacing: FBC HVHZ Approved mechanically attached or adhesive-set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
6.3.2 Deck Type 1: Wood,Non-Insulated
Deck Description: Min.19/32"plywood or wood plank
System Type E: Base sheet mechanically fastened to deck;underlayment adhered to base sheet
Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap,mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6-inch o.c.at the lap-edges and 12-inch o.c.
in a staggered grid-pattern between the overlaps.
Cap Ply: LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO 5A SMOOTH PLY 40, LASTOBOND Shield HT,
LASTOBOND Pro HT-S, EnviroShield, LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment,
LASTOBOND Smooth Seal HT,Tri-Built Smooth HT S/A Underlayment or Grip-Rite Smooth Seal HT,self-
adhering.
Surfacing: FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate-type shingles, wood
shakes or wood shingles.
6.3.3 Deck Type 1: Wood,Non-Insulated
Deck Description: Min.19/32"plywood or wood plank
System Type E: Base sheet mechanically fastened to deck;underlayment adhered to base sheet
Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap,mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps(FBC HVHZ 1517.5),6-inch o.c.at the lap-edges and 12-inch o.c.
in a staggered grid-pattern between the overlaps.
Cap Ply: LASTOBOND ECO,RESISTO LB1236,TRI-BUILTSand-R SA Shingle Underlayment,Grip-Rite Eave&Valley
Protector,TopShield ICE&WATER DEFENDER or RESISTO LB1244,self-adhering.
Surfacing: FBC HVHZ Approved asphalt shingles,slate,slate-type shingles,wood shakes or wood shingles.
NEMO ETC,LLC. Evaluation Report 3m-SOPC-2I-FBCER.A
Certificate ofAuthorization#32455 7-EDITION(2020)FBC HVHZ EVALUATION FL2569-R22(HVHZ)
SOPREMA Roof Underlayments Revision 0:04/19/2021
Page 6 of 7
OMEMO etc.
7. BUILDING PERMIT'REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for-manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer to Section 4
herein for products and production locations having met codified material standards.
QUALITY.9.
UL LLC—QUA9625;(414)248-6409;Karen.buchmann@ul.com
-END OF EVALUATION REPORT-
I
I
NEMO ETC,U.C. Evaluation Report 3m-SOPC-2I-FBCER.A
Certificate ofAuthorizotlon#32455 7-EDITION(2020)FBC HVHZ EVALUATION FL2569-R22(HVHZ)
SOPREMA Roof Underlayments Revision 0:04/19/20I2
Page 7 of 7
. ,
��
I