Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL WINDOW HORIZONTAL SLIDER Florida Building Code Online https://floridabuilding.org(pr/pr_app_dtl.aspx?pares.. �,�W-1. 7t .M.R,.. , `"a BCIS Hone Log In User Registration Hot Topics Submt Surcharge Stats&Facts Publications ��CoMe ct �S rte s� Search Ud, fa;ides 1� e kOff ;° Product Approval L?.." ��. �!USER:Pubbc User �p t� ® � �{�v �./ ### ��y� I E!/�f'E 19—®r�ZjVi P rod ict Arytmva Rd enu>P•orarct n*Argifx:alion Seaton>;,ppSzatml-ist>Application De tall CODE COMPLIANCE ®IMP IAN _E c pc a FL# FL14090-R12 STo LUCIE COUNTY r: _.•,� Application Type Revison r Code Version 2020 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer JELD-WEN Address/Phone/Email 3737 Lakeport Blvd Klamath Falls,OR 97601 (800)535-3936 fbcl@jeld-wen.com Authorized Signature Rylee Sumner Fricks fbcl@jeld-wen.com Technical Representative JELD-WEN Corporate Customer Service Address/Phone/Email 3737 Lakeport Blvd. Klamath Falls,OR 97601 (800)535-3936 customerserviceagents@jeld-wen.com Quality Assurance Representative Ad d ress/Ph on e/Em ai I Category Windows Subcategory Horizontal Slider Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By 1 of 3 9/2/21, 20:46 Florida Building Code Online https://floridabuilding.org/pr/pr_app_cltl.cispx?pares.. Product Approval Method Method 1 Option A Date Submitted 11/18/2020 Date Validated 11/19/2020 Date Pending FBC Approval Date Approved 11/24/2020 Summary of Products FL# Model,Number or Name Description 14090.1 Premium Atlantic Vinyl Horizontal Slider(8200) 74"x 62"Insulated Glass(3/16 in-3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090_R12_C_CAC NI011635-R1.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 07/31/2025 Design Pressure:+50/-55 Installation Instructions Other:Windowswith insulated glassunitswider than FL14090_R12_II_DP50-55 74x62_Installation_Instructionspdf 36"require setting blocks Laminated glazing interlayer Verified By:Hermes Norero,PE 73778 material requirements meet the current edition of the Created by Independent Third Party:Yes FBC in accordancewith Miami-Dade NOA for DuPont Evaluation Reports SentryGlas and DuPont PVB interlayers FL14090_R12_AE_PER3105.pdf Created by Independent Third Party:Yes 14090.2 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 54"Insulated Glass(3/16 in-3/16 out Annealed) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090_R12_C_CAC_N1011636-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:No 07/31/2025 Design Pressure:+65/-70 Installation Instructions Other:Windowswith insulated glassunitswider than FL14090_R12_II_DP65-70 74x54 Insta lation_Instructionspdf 36"require setting blocks Laminated glazing interlayer Verified By:Hermes N orero,PE 73778 material requirements meet the current edition of the Created by Independent Third Party:Yes FBC in accordancewith Miami-Dade NOA for DuPont Evaluation Reports SentryGlas and DuPont PVB interlayers FL14090_R12_AE_PER3102.pdf Created by Independent Third Party:Yes 14090.3 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 62"Insulated Glass(5/16 SGP Lam in 3/16 Annealed out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090_R12 C CAC N1011681-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 08/30/2025 Design Pressure:+50/-55 Installation Instructions Other:Windowsw/IG unitswider than 36"require FL14090_R12_II_DP50-55_LMI 74x62_Insallation_Instructionspdf setting blocks Thesewindowsdo not meet small missile Verified By:Hermes Norero 73778 impact wind-borne requirements of the current edition of Created by Independent Third Party:Yes the FBC when the exterior lite is annealed,they do meet Evaluation Reports small missile impact wind-borne protection requirements FL14090_R12 AE PER3103.pdf when the exterior lite istempered.Laminated glazing Created by Independent Third Party:Yes interlayer material requirements meet the current edition of the FBC in accordance w/Miami-Dade NOA for DuPont SentryGlas and DuPont PVB interlayers 4!!::� Premium Atlantic Vinyl Horizontal Slider(8200)74"x 54"Insulated Glass(5/16 PVB Lam in 1/8 Annealed out) Limits of U e Certification Agency Certificate d for use in HVHZ:Yes FLl4090_Rl2_C_CAC_NIO11745-RI.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 10/31/2025 Design Pressure:+50/-55 Installation Instructions Other:Windowsw/IG unitswider than 36"require FL14090_R12_11_DP50-55_74x54_LMI_InstaJlation_Instructionspdf setting blocks These windows do not meet small missile Verified By:HermesNorero,PE 73778 impact wind-borne requirements of the current edition of Created by Independent Third Party:Yes the FBC when the exterior lite is annealed,they do meet Evaluation Reports small missile impact wind-borne protection requirements FL14090_R12_AE PER_3101.pdf when the exterior lite is tempered.Laminated glazing Created by Independent Third Party:Yes interlayer material requirements meet the current edition of the FBC in accordance w/Miami-Dade NOA for DuPont SentryGlas and DuPont PVB interlayers 14090.5 Premium Atlantic Vinyl FH,/r,,zontal Slider(8200)74"x 54"Insulated Glass(5/16 SGP Lam in Annealed out) 2 of 3 9/2/21, 20:46 Florida Building Code Online https://floridabuilding.org/pr/pr_app_citl.aspx?pares.. Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090_R12_C_CAC_N1011682-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 08/30/2025 Design Pressure:+60/-65 Installation Instructions Other:Windowsw/IG unitswider than 36"require FL14090_R12_II_DP60-65_LMI_74x54_Installation_Instructionspdf setting blocks.Thesewindowsdo not meet small missile Verified By:Hermes Norero,PE 73778 impact wind-borne requirements of the current edition of Created by Independent Third Party:Yes the FBC when the exterior lite is annealed,they do meet Evaluation Reports small missile impact wind-borne protection requirements FL14090_R12_AE_PER3104.pdf when the exterior lite istempered.Laminated glazing Created by Independent Third Party:Yes interlayer material requirements meet the current edition of the FBC in accordancew/Miami-Dade NOA for DuPont SentryGlas and DuPont PVB interlayers 14090.6 Premium Atlantic Vinyl Horizontal Slider(8200)74"x 62"Insulated Glass(5/16 PVB Lam in 3/16 Annealed out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090_R12_C_CAC_N1011745.01-Rl.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/30/2025 Design Pressure:+50/-50 Installation Instructions Other:Windowsw/IG unitswider than 36"require FL14090_R12_II_DP50_74x62_LMI_Installation_Instructionspdf setting blocks Thesewindowsdo not meet small missile Verified By:Hermes Norero 73778 impact wind-borne requirements of the current edition of Created by Independent Third Party:Yes the FBC when the exterior lite is annealed,they do meet Evaluation Reports small missile impact wind-borne protection requirements FL14090 R12 AE PER2692.pdf when the exterior lite istempered.Laminated glazing Created by Independent Third Party:Yes interlayer material requirements meet the current edition of the FBC in accordancew/Miami-Dade NOA for DuPont SentryGlas and DuPont PVB interlayers 14090.7 Premium Atlantic Vinyl Horizontal Slider(8200)111"x 54"Insulated Glass(5/16 PVB/SGP Lam in-3/16 Tempered out) Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL14090_R12_C_CAC_N1013719-RI.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 04/30/2025 Design Pressure:+50/-55 Installation Instructions Other:These windows meet small missile impact wind- FL14090_R12_II_PAV XOX Installspdf borne protection requirements as required by FBC, Verified By:Joseph A.Reed 58920 section 2411.3.3.7 when the exterior lite is tempered. Created by Independent Third Party:Yes Laminated glazing interlayer material requirements meet Evaluation Reports the current edition of the FBC in accordance with Miami- FL14090_R12_AE_22068-1.pdf Dade NOA for DuPont SentryGlas and DuPont PVB Created by Independent Third Party:Yes interlayers. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO errpbyer.Copyright 2007-2013 State of Florida.::Privacy state rre nt::Access bity.State rte nt::Refund State rre nt Under Florida law,a rta r addresses are public records.If you do not want your a-rrai address re le as e d in response to a public-re cords request do not send electronic rra Ito this entry,Instead,contact the office by phone or by tradkional rra IL If you have any questions,p@ as a contact 850.487.1395.*Pursuant to Section 455.275(1),Florida Statutes. effective October 1,2012,licensees licensed under Chapter 455,F.S.nuslprovde the Departrrentwlth an errai address if they have one.The enacts provided nay be used for off bed comrunbatbn with the ice ns a e.H oweve r e nail addresses are public record.If you do not wish to supply a personal address,please provide the De pa rare nt wth an enai address which can be trade avalable to the public.To detenrite d you area licensee under Chapter 455,F.S.,please crick here. Product Approval Acce pts: _ , low J® c?hecY M Credit Card Safe 3 of 3 9/2/21, 20:46 NOTICE OF PRODUCT CERTIFICATION "'�CER17F7t,4 �" c` �'�y •o CERTIFICATION NO: NI011745-RI a DATE: 12/20/2013 CERTIFICATION PROGRAM: Structural COMPANY: JELD-WEN CODE: 1822-1 Eo paoo _y- REVISION DATE: 06/10/2017 To verify that the"Notice of Product Certification"is valid,please visit www.NANilCertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification ication and that certification criteria has been satisfied. A NAMI approved certitication label must be applied to theproduct to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl" 3737 Lakeport Boulevard Horizontal Slider 8200 Window (Impact) Klamath Falls, OR 97601 Configuration: XO Glazing: IG-US" Annealed Glass-Laminate-1,`S" Annealed Glass/0.090" DuPont PVB Interlayer`li8" Annealed Glass Frame: W-1879111m(74.00") 1-1-1371mm(54.00") Vent: W-939mm(37.00") 11-1301nun(51.25") DLO: W-8541nm(33.62") 1-1-1282mm(50.50") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: 2394 Pa (50 psi) Negative Design Pressure: 2633 Pa (55 psi) Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3896-01 Expiration Date: October 31,2025 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124/ Fax: (804) 684-5122 NOTICE OF PRODUCT CERTIFICATION la CERTIFICATION NO: NI011745-R1 >' �7 DATE: 12/20/2013 11� \M 1f CERTIFICATION PROGRAM: Structural % a �, ,"_ COMPANY: JELD-WEN CODE: 1822-1 REVISION DATE: 06/10/2017 To verify that the"Notice of Product Certification"is valid,please visit www.NA\4lCertl f icilholLCon1 t0 aSSUre that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certificationcriteria has been satisfied. A NAM[approved certification label must be applied to theproduct to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl" 3737 Lakeport Boulevard Horizontal Slider 8200 Window (impact) Klamath Falls, OR 97601 Configuration: XO Glazing: iG-1/8" Annealed Glass/Laminate-1/8" Annealed Glass/0.090" DuPont PVB interlaver/I/8" Annealed Glass Frame: W-18791nm(74.00") 1-1-1371mm(54.00") Vent: W-939mni(37.00") 11-1301 nnn(5 L25") DLO: W-854mm(33.62") 1-1-1 282nun(50.50") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: 2394 Pa (50 psf) Negative Design Pressure: 2633 Pa (55 psf) Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3896-01 Expiration Date: October 31,2025 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124/ Fax: (804) 684-5122 NAIL FIN INSTALLATION i 1(.'T'MIN ENBEDMENi y-I ''p I 1 2 xX'NOOD FRAME MIN DISTANCE FOR EDGE;3/4" MIN,DISTANCE FOR EDGE.314• 1 2X WOOD 3 FRAME Il4'MAX 3 Wlf.1DW�11 SNIM SYAGE I 2 1/4`MAX SHIM SPACE 3o3omm ! 1112"MIN. EMBEDMENT . 1 r.A—oEr.n i FRAME SECTION(TYP) JAMB SECTION(TYP) VERTICAL sEcttoN HORIZONTAL SECTION Ill'MAk MIN DISTANCE 11 TYPTCAL ELEVATION WITH FAST NER SPACING FOR EDGE 314- t 2 X WOOD FRA.4E ! Max Frame DP RATING IMPACT iR'MIN.EMBEDMENT 1 74 x 54 +50/-55 YES !,_._T.........I.,.—.,.--------....-- _ ....._...._..__T__ ...J L.._........ .. ............... .........._.._._. _.. ........_ _ - Installation Notes: General Notes: 1. Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load Criteria 2. Use 410 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida 10 into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to property transfer all loads 2. All glazing shall conform to ASTM El300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 3 mm annealed 111 mm airspace 13 mm annealed 12 mm PVB by project of installation Dupont 13 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind bome debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations ����� t t t t t f //i/ 7. Maximum sizes are buck sizes and do not include fin or Mange., noted. 11 is not intended as a guide to the installation process and does PROJECT ENGIi+EER: DATE': i 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall Q- �` 01/30/2014 conditions. For the complete installation procedure,see the instructions ��; ��- �'J�� i DMw'N BY: SCALE; J LLN Klamath Falls,OR.97601 packaged with the window or go to 7 �' D.Vezo NTS Phone: (541)882-3451 wAu.jeld-wen.comlresourcesfinstallafion. _ j'E Cola TITLE: F cc = APPRO'EDBY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: This and its contents are confidential and are not to be %�� - C 0P— 40 Nail Fin Installation(74"x 54") drawing PMT PRO E3,No reproduced or copied in whole or in part or used or disclosed to others i ivo � Db0�346 except as authorized by JELD-WEN Inc. 398 t!d �e 338 IDENTIFIER N. PUWT NAME AND LOCATION: (AD DWG.No.: REV: SHEET NCTL210-3896- -FBC D = MIN DISTAWE INSTALLATION FOR E IX625' 2 EMBEDMENT 1 L12*MIN EMIRU)MENT I/A*MAX SNLN.SPACE SHIM S-ACE 3 MQ -MAIL TOU 220- 20 30 3 MIN,DISTANCE 2 FOR EDGE................ ..... ----------- &ASS O�TE :3 0 Do,995 6 A M­*I TA JAMB SECTION(TYP) FRAME SECTION(TY?) HORIZONTAL SECTION VERTICAL SECTION T T r 6�T T 3 1 112.MIN TYPICAL ELEVATION WITH FASTENER SPACING EMAEDMENT Max Frame I DP RATING IMPACT FMEYE 3/4' 74 x 54 +50/-55 YES ............. ...................................................... Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the Wind load crileria 2. Use#10 PH or greater fastener though the jamb with sufficient length to penetrate a minimum of 1 1/2' of the adopted International Building Code(IBC).the International Residential Code(IRG),the Florida into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to property transfer all loads 2. All glazing shall conform to ASTM E 1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum.glazing shall be 3 mm annealed 111 min airspace/3 mm annealed/2 mm PVB by project of installation. Dupont 13 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening, 6. An impact protective system is not required where wind bome debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does ♦ not address the sealing consideration that may arise in different wall ......♦ .. . Pqo)Ecr ENGINEER: DATE, 3737 Lakeport Blvd 02/03/2014 conditions. For the complete installation procedure.see the instructions • DRAWN BY: SCALE: JELDVEN Klamath Falls,OR.97601 packaged with the window or go to 0 D.Vezo NTS Phone: (541)882-3451 -ei,Aw.jeld-wen.com/resourcesfinstallation, _79-- '. '. CHECKED BY: TITLE: / : W J.Kantola DISCLAIMER F it Z: APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider 44/ , -- This drawing and its contents are confidential and are not to be lz/ %- PART Through Through Frame Installation(74"x 54") reproduced or copied in whole or in part or used or disclosed to others • ♦ DO 9146 except as authorized by JELD-WEN Inc. 398 WU IDETTTIFIER M NWT Nk",E AND LOCATION: CAD EAV6.I— IEJ_ — NCrL210-3896- FL 1nra MASONRY INSTALLATION T 2 4 EWEDMEW ll<-MAx -3 SHIN i0A(F 14m .114 DIST Fa ED6E ---------- &LrCK JAMS 5ECTION(TYP) HORIZONTAL SECTION FRAME SECTION(TYP) VERTICAL SECTION t T-�T wmv pe v TYPICAL ELEVATION WITH FASTENER SPACING IV, MUN "ED.E.T Max Frame UP RATING 3 74 x 54 +50/-55 YES EDGE 2 .................... General Notes: Installation Notes: 1 Seal flangelframe to substrate, 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use 3/16'Tapcon or equivalent fasteners through frame with sufficient length to penetrate a minimum of the adopted International Building Code(IBC),the International Residential Code(IRC).the Florida oft 114"into concrete or masonry at each location with a 2 112"min from edge distance.For concrete Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. (min.fc=3000psi)or masonry substrate(CMU shall adhere to ASTM C90). 2. All glazing shall conform to ASTM E 1300. 3, Host structure(wood buck,masonry.steel)to be designed and anchored to property transfer all loads 3. At minimum.glazing shall be 3 mm annealed 111 mm airspace 13 mm annealed 12 mm PVB by to the structure. The host structure is the responsibility of the architect or engineer of record for the Dupont/3 min annealed. project of installation. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations 0% c P: A, 1.,." 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does PROTECT ENGINEER: DATE' not address the sealing consideration that may arise in different wall 01/30/2014 3737 Lakeport Blvd conditions. For the complete installation procedure,see the instructions CRAW4 BY: SCALE: ff-LDWEN Klamath Falls,OR.97601 packaged with the window or go to 7D.Vezo NTS Phone: (541)882-3451 CHECKED BY: w,Aw.jeld-wen.com/rescurcesfinstallaflon. J.Kantola TITLE: ir Z: APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: 44/ This drawing and its contents are confidential and are not to be % PARTtPROIE(-r N Masonry Installation(74"x 54") R:Ad reproduced or Copied in whole or in part or used or disclosed to others I D009346 except as authorized by JELD-WEN Inc. 308 Cdpe G 338 1111'rIIIER 11q, 11 1E AIM I.TI1111: ICAD DWG.*11-: REY: SHEET F NCTL210 3896-�-FBC STEEL INSTALLATION 1 I---�MIN DISTANCE FOR EDGE 1/2' tAA, Min emb<axent IMX.n+wE Cams ------------ rL I I 1B m- S gamemm yl 1 i smd srw'n � Suci stud 1 114'MAX 1/4'MAX ` SHIM SPACE sHLM SPACE 14AT0'O.G I� MIN DISTANCE 1 VAtL Iio� 22omn rOR EDGE 1/7" TVAYc zom MFn:embuim<M 3 "�����Jff �rrree rh�e0:s r• s*fume I + L.;, in Wass RI Dow rn 1 i �A AnrxS Drun I IAMB SECTION(TYP) FRAME SECTION(TYP) HORIZONTAL SECTION j VERTICAL SECTION ~T T t 1/4'MAX 1 SHIM SPACE lg oauge m... 1, I'woaT emn pA- - TYPICAL ELEVATION WITH FASTENER SPACING Min.emMdmen+ 2 Max Frame DP RATING IMPACT i of rhrc<.m-ems Igist frm MIN DISTANCE 74 x 54 +50/-55 YES FOR EDGE 1/2' Installation Notes: General Notes. 1. Seal flangetframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. For anchoring into metal framing use#10 TEK Self Tapping screws with sufficient length to achieve a of the adopted Intemational Building Code(IBC).the International Residential Code(IRC),the Florida minimum embedment of three threads past the frame thickness. Steel substrate min.l8ga..fy=33 ksi. Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.2 All glazing Thal(conform to ASTM E1300. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to property transfer all loads 3 At minimum,glazing shall be 3 annealed!11 mm airspace 13 mm annealed r 2 mm PVB by to the structure. The host structure is the responsibility of the architect or engineer of record for the . Dupont!3 mm annealed. project of installation. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind bome debris protection is mandated by local This schedule addresses only the fasteners required to anchor the ,,t t t I t t t f7j building code. window to achieve the rated design pressure up to the size limitations N%% �i 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does i PROIER ETSGRER: DATE: not address the sealing consideration that may arise in different wall 01/30/2014 Y �.`�{�`{�/�y N 3737 Lakeport Blvd conditions. For the complete installation procedure,see the instructions : ��;'��••• 0 i DRAM BY: srALE: �Li� 11 JVi\ Klamath Falls,OR.97601 packaged with the window or go to ; 7 � D.Vezo NTS t�aDDD Phone: (541)882.3451 wway.jell-wen.conl/resourcesfinstallation. =_ �Ir * — CHEO ED BY: TITLE: 3•Kantola DISCLAIMER: v T T a = APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider This drawing and its contents are confidential and are not to be %�0 rL�t��c OQ ��: PART PRo r,�• Steel Installation(74"x 54") reproduced or copied in whole or in part or used or disclosed to others ��i�>3bam1 �`` D30 646 except as authorized by JELD-WEN Inc. see 6�dpt �e 338 IDENIIFIER III. P Af T NAME AND I. 1111: CAD DWG.110 REv; SHEET NCTL210 3696 -FBC AaF• NAIL FIN INSTALLATION L(!2'MIN.EMBEbMENT 2zX rlocO F>snME MIN.DISTANCE FOR EDGE:3/4" MItl USTAt E FOR EWE 3,4* i 2X WOOD i FRAME Ir 2 1/4"MAX r,,_SHIM SPACE 220- 20- 30 30— IN 1 1/2 M EMBEDMENT MAX 'HIM SPACE �N W FRAME ------------ T// FRAME SECTION(TYP) IAMB SECTION(TYP) VERTICAL SECTION HORIZONTAL SECTION 1!4•MAX SHIM SPACE WW YIOIM Cyr DI-AISE 1 TYPICAL ELEVATION WITH FASTENER SPACING FOR E[,SE 314" I ?X WOOD FRAME r Max Frame DP RATING IMPACT I IZ'.111 FMAEU ENT 74 x 54 +50/-55 YE5 Installation Notes: General Notes: 1 Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use;110 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 of the adopted International Building Code(IBC).the International Residential Code(IRC),the Florida 1,12'into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTMI E 1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. Al minimum,glazing shall be 3 mm annealed i 11 mm airspace 13 min annealed!2 mm PVB by project of installation. Dupont/3 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. Window to achieve the rated design pressure up to the size limitations 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does %V O'C'— 1, not address the sealing consideration that may arise in different wall PRWECT U4GINEER: DATE: 01/30/2014 3737 Lakeport Blvd Klamath Falls,OR.97601 conditions. For the complete installation procedure,see the instructions 'ZZ DRA BY; SCALE: JELDIVEN D."Vezo NTS Phone: (541)882-3451 packaged With the window or go to 77--�-' - I -Aww jeld-wen.com/resourcesrinstallation. • [NECKED BY: TITLE: J.Kantola t- Er APPRUVED BY; Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: QJ Nail Fin Installation(74"x 54") This drawing and its contents are confidential and are not to be 0 4c,, Z- JPARUCR01ErTf1.' reproduced or copied in whole or in part or used or disclosed to others :. 09346 a 0. except as authorized by JELD-WEN Inc. 398 &K UM I IDENTIFIER I CAD D-.VG.�1- I PEW; JS.EET E & NCTI-210-3896-J"FLAk"Am A"LocAno"; - -- - --- -- __.._. .___._.-_.- __.___ _ _-__-- .. _.. .__-____----._, THROUGH FRAME INSTALLATION Mi21 DI5TANCE FOR EWE.31W 3 ..-. i 124n,D.c. aa'uAz Mom2 , e'MIN. co"Do ! i 1 f ! fMaEDAIENT EMBEDMENT J 1 1 1/4'MAX ~ t V4'M' I SHIM SPACE 5.1M 5F.cE 3 ' l — 1LAB•wAL ou — fRJJ I I ee.0- �( MIN.bI'STANCE 1 ( I FOR EDGE.3/4• 2 t ....... ...� 7 :A5058 T __________ DC'.'"5 ! 1 i w"'^ nor• JAMB SECTION(TYP) !I FRAME SECTION(TYP) HORIZONTAL SECTION VERTICAL 5ECTION I MAX L-T T T T T Ti t 5Y1M 5o.cE r.Tioov Tram p.•YAc) I ,.. ..._- - -- - - - — -Z - TYPICAL ELEVATrON WITH FASTENER SPACING M2N i EMREREDM.ENr Max Frame DP RATING IMPACT MIN.O:E 3!1 FOREWE ll x 74 54 +50/-55 YES I I Installation Notes: General Notes: 1. Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply With the wind load criteria 2. Use;#10 PH or greater fastener though the jamb with sufficient length to penetrate a minimum of 1 1/2" of the adopted Intemational Building Code(IBC),the International Residential Code(IRC),the Florida into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. Al minimum,glazing shall be 3 mm annealed/11 mm airspace 13 mm annealed 12 mm PVB by project of installation. Dupont/3 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind bome debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations �����t t t I t t t77�/�' 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does �� �� PRGrcCr ENGINEER: DATE; i 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall Q F �� 02/03/2014 • \ .• DRAWN BY: SCALE: �7 t�J,j� Klamath Falls,OR.97601 conditions. For the complete installation procedure,see the instructions Z : O D.Vezo NITS Phone: ails, R.97601 packaged with the window or go to 7 OHEO:ED BY: TITLE: vrwtiv.jeld-wen.comtresourcesfinstallaffon. _ * = * — 3.Kantola DISCLAIMER: APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider This drawing and its contents are confidential and are not to be %A0 • . DQ: 46 : PART o,Ecr ND• Through Frame Installation(74"x 54") reproduced or copied in whole or in part or used or disclosed to others ��i a �, o l���� D�09A except as authorized by JELD-WEN Inc. see><dpt ;DI[O 3W[IDEI—MIIER N.. PUWT MANE AND LGGTION: CAD DWG.Na' Re1; S4EET a Q� NCTL210 3896- -FBC e NeE MASONRY INSTALLATION F�EWEMitt MASIXtRv FKU 4 4 1 1/4'MIN EMBEDMENT :1 MAY 1/.'MAX 3 S.r.VICE ME rfwE F0 VAX.TM 5—SOME N bISTINCE Q E64c 2 fir 20— ---------- ISON-Y BLOC� JAMB SECTION(TYP) if HORIZONTAL SECTION FRAME (TYP) VERTICAL SECTION T T MAX 9ACE WMN nre MIN TYPICAL ELEVATION WITH FASTENER SPACING 4 2 EMBEDMENT Max Frame OP RATING CT 3 74 x 54 :'v- +50/-55 YES M.0"TIIXT FM EDGE ..................... Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load Criteria 2. Use 3116'Tapeon or equivalent fasteners through frame with sufficient length to penetrate a minimum of the adopted International Building Code(IBC).the International Residential Code(IRC),the Florida of 1 IA"into concrete or masonry at each location with a 2 1/2'min from edge distance.For concrete Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. (min.fc=3000psi)or masonry substrate(CMU shall adhere to ASTIA C90). 2. All glazing shall conform to ASTM El 300. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing shall be 3 mm annealed 111 min airspace/3 min annealed i 2 mm PVB by to the structure. The host structure is the responsibility of the architect or engineer of record for the Dupont 13 mm annealed. project of installation. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind bome debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. Window to achieve the rated design pressure up to the size limitations 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does 'V PROJECT Et GMEER: DATE: 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall 01/30/2014 Klamath Falls,OR.97601 conditions. For the complete installation procedure,see the instructions WW'i BY: SEALE; JELWWEN packaged with the window or go to 7 D.Vezo NTS Phone: (541)882-3451 CH BY: www.jeld-wen.com/resourcesrinstallaflon. 3.Kant TME: ola Z: APKOVED BY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: This drawing and its contents are confidential and are not to be Masonry Installation(74"x 54") reproduced or copied in whole or in part or used or disclosed to others :9. a P66034 I except as authorized by JELD-WEN Inc. 398 W8 1DRITIFIER No. I PUNT NANIE ANC LOCATION: -D DWG.I- R&; "- 117 ... ... NCI-1-210-3896-I-FBC 30- STEEL INSTALLATION M.IN DI5TAW-E FOR EDGE 1l2' 2 Min b d- .O.G of,h—threads c 16.75 olK "' 3 �5,r,a,�-r I I 100B Steel Stu 5 gouge mn ld gexje min 1 1 i y t MAX 5H t:4•MA Swill 3vA[E .I SHtM SPXaLE 1 Tiu MIN pI5 T ANCE m+� zz.a n., FOR ' I/2" 2. v s` i M�n,CmbWmcnt of three th^eOd5� i SlrRme ----------- ` +fit cLA sseI-E DDV!9175 � /A ATttK CETAti 1 TAMS SECTION(TYP) I FRAME SECTION(TYP) HORIZONTAL SECTION VERTICAL SECTION ! ~T T Tj t I I/A'MAX 1 SHrM SPACE B x ye mn rww aorR OA•wa-) I 3 TYPICAL ELEVATION WITH FASTENER SPACING �LJ Max Frame DP RATING IMPACT 61IN DISTA#KEs 74 x 54 +50/-55 YES FOR EDGE.1/2' Installation Notes: General Notes: 1. Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. For anchoring into metal framing use#10 TEK Self Tapping screws with sufficient length to achieve a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida minimum embedment of three threads past the frame thickness. Steel substrate min.l8ga.,fy=33 ksi. Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2' All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 1 At minimum,glazing shall be 3 mm annealed 111 mm airspace 13 mm annealed!2 mm PUB by project of installation. Dupont!3 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind bome debris protection is mandated by local This schedule addresses only the fasteners required to anchor the `t building code. window'to achieve the rated design pressure up to the size limitations `0� Maximum sizes are buck saes and do not include fin or flange. noted. It is riot intended as a guide to the installation process and does PROTECT ENGINEER: DATE: i 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall Q' �` �� 01/30/2014 ,��11 ]l3raW`/T • \• • 'A� DRAWN BY: SCnLE: id ..EN Klamath Falls,OR.97601 conditions. Far the complete installation procedure,see the instructions Z packaged with the window or go to D.Vezo NTS Phone: (541)882-3461 wwtiv.jeld-wen.com!resources!installaflon. - * 7 - * = cN�Der TITLE: J.Kantola DISCLAIMER: = -° T T F X = APP0.ovEDBY: Premium Atlantic Vinyl Impact Horizontal Slider This drawing and its contents are confidential and are not to be %�� C D� :" ��: PaRT o,Ecr rw Steel Installation(74"x 54") reproduced or copied in whole or in part or used or disclosed to others ��i , N, l'��� D 09346 except as authorized by JELD-WEN Inc, sae Is�f9t iLWTA 3$e IDENT[F1ER N.. PLANT Na:E AND LOCATSUN: FC DWG.No.: REV: SHEET �( NCTL210-3896 -FBC ^oFA NAIL FIN INSTALLATION 1 I/2'MIN EMBEDMENT y�[yy�jp t 2 2X VioCD FRAME I MIN.DISTANCE FOR EDGE:3t4" MIN DISTANCE I FCC PDGE.5/4' 2x WOOD 3 FRAME 1�-ua l v4•MAx 3 1 �-f@I � � SHIM 9nCE 4 j� SHI MA. sHiM SPACE 1 MIN. 't I EMBEDMENT �. a ELASS BITE' 130— I rw,uTAn 1 FRAME SECTION(TYP) TAME SECTION(TYP) VERTICAL sECTiON HORIZONTAL SECTION i I'l MAX SHIM 5>'ACE "` .—._— —...... R09"KDM(14•IYZ) I 1 3 MIN b:STANCE - FOREW4 3/4' TYPICAL ELEVATION WITH FASTENER SPACING 2 )X WOCO FRAME 'i i i ) Max Frame DP RATING IMPACT a MIN EMBEDMENT ! 74 x 54 +50/-55 YES Installation Notes: General Notes: 1 Seal(lange!frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use#10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 of the adopted Intemational Building Code(IBC).the International Residential Code(IRC).the Florida 112'into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 3 mm annealed 111 mm airspace/3 min annealed 12 min PVB by project of installation. Dupont/3 min annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code, window to achieve the rated design pressure up to the size limitations Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does PRO)ER ENGINEER: DATE i not address the sealing consideration that may arise indifferent wall 3737 Lakeport Blvd Q (<` �� 01/30/2014 conditions. For the complete installation procedure,see the instructions Z DRAWN BY: SCALE: JELYATEN Klamath Falls,OR.97601 packaged with the window or go to 7 D.Vezo NTS Phone: (541)882.3451 wytiw.jeld-wen.com/resourcesrinstallafion. ED BY: JEKantola TITLE DISCLAIfI1ER: = n = APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider This drawingand its contents are confidential and are not to be %�0 C DP:•.��: Nail Fin Installation(74"x 54") PART ROIECT No reproduced or copied in whole or in part or used or disclosed to others i , , .No- e'� D�0934� except as authorized by JELD-WEN Inc. sea E�dpt $�d -ate 9s8 IDENTIFIER W PIMT BANE AND tOGTION: CAD DWG.11— REV: SHEET Aps NCTL210-3896- -FBC = THROUGH FRAME INSTALLATION r MVI DISTANCE ! FCQEot_3:a- tine'as ae•WX 1(yL rRW[ rWWi am 2 11/"MIN,EMBEDMENT i 1 1R"MIth. EMBEDMENT 1 1 1 y I 1 055PACI ' i•MA% L !I SHTM SPACE 3 tuTe-o.c. j _.---- r7Gu[� I vD— - ti I�I 2 30 3D. 30m t ' TFOR EDGE 3DISTA/4' ----------- .�� �F I `� 130 rtr I DC'N M 1 r ( R JAMB SECTION(TYP) FRAME SECTION(Tva) HORIZONTAL SECTION VERTICAL SECTION ~T T T t SNTM SPACE 3 �_....----- -.._..---------- nomov tttmx(T4•—L) TYPICAL ELEVATION WITH FASTENER SPACING 2 I yr Mr f E1 rMIN 1 Max Frame I DP RATING IMPACT MIN DISTANCE FOR EW 3.•4' 74 x 54 1 +50/-55 1 YES 1. I I Installation Notes: General Notes: 1. Seal Rangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use#10 PH or greater fastener though the jamb with sufficient length to penetrate a minimum of 1 10 of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to property transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum.glazing shall be 3 mm annealed 111 mm airspace 13 mm annealed 12 mm PVB by project of installation. Dupont!3 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind bome debris protection is mandated by local This schedule addresses only the fasteners required to anchor the t t / building code. window to achieve the rated design pressure up to the size limitationsP A, 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does �� �� PROIEa ENGRSER: DATE: i 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall �� Q F �� 02/03/2014 \ 'A0 . DRAWN BY: w„�, r•L.�EN Klamath Falls,OR.97601 conditions. For the complete installation procedure,see the instructions ;'\ D.Vezo NTS Phone: (541)882-3451 packaged with the window or go to 7 : = CHECKEI BY: TITLE: v/ww.jeld-wen-com/resourcestnstallafion. _ * * — 3.Kantola DISCLAIMER: = ° T T a' = APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider This drawing and its contents are confidential and are not to be %�� C 0� 14; : pART/pR01 ND Through Frame Installation(74"x 54") reproduced or copied in whole or in part or used or disclosed to others � n xo D00946 except as authorized by JELD-WEN Inc. see kept 339 IDENTIFIER N0. PUNT NAME AND LIGATION: CAD DWG.CIO.: REU: SHEET e NCTL210 3896- -FBC 2 or I M7U DiSTAFKE MASONRY INSTALLATION FCR EOGf:IlY ie G tr.ASam 1&75"o.c. 11w o•a• ( Y 1 fLL[.lYYC cob, 1"A.FA[N 'a, •a 3 EMaeoMENT i 1 1 ,V a'IAIN ti EASBEDMENT I Ile-MAX j 3 1:1'k.AX 1J.376•o.t j 5W.nlA CE 5t1I.Y.SPACE MA 7pp1 I NIN DiSTA.'.CE ERAyE i l FOR EDGE D UZ' V V zo,M. Z tJff cuss airE � Bceu oaw vr. 1 JAMB SECTION(TYP) i f; aArmr. TAn HORIZONTAL SECTION FRAME SECTION(TYP) _ VERTICAL SECTION i T T iSHIM,$DACE I '. i TYPICAL ELEVATION WITH FASTENER SPACING iW NIN Z EWbMEW Max Frame N RATING IMPACT a A5 74 x 54 +50/-55 YES MAsormr IA,N MIA-1 'OP EPtE Installation Notes: General Notes: 1. Seal fiangeitrame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use 3 an Tapcen or equivalent fasteners through frame with sufficient length to penetrate a minimum of the adopted International Building Code(IBC),the International Residential Code(IRC).the Florida of 1 1/4"into concrete or masonry at each location with a 2 112'min from edge distance.For concrete Building g shall conBC)including HVHZ and the industry requirement for the stated conditions. 300. (min.Pc=3000psi)or masonry substrate(CMU shall adhere to ASTM C90). 2. All glazing shall conform to ASTM 3 annealed 3. Host structure(wood buck,masonry.steel)to be designed and anchored to property transfer all loads . At minimum.glazing shall be 3 mm a annealed!11 mm airspace 13 mm annealed 12 mm PVB by to the structure. The host structure is the responsibility of the architect or engineer of record for the Dupont 13 mm annealed. project of installation. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind bome debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations tit 1111 -1i/ 7. Maximum sizes are buck sizes and do not include fin or flange. � noted. It is not intended as a guide to the installation process and does PROJECT ENGINEER: DATE: � �i 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall Cc �� Ol/30/2014 ��y1 •■p`�I�[,y7Ty • \ 'J DRAWN BY: SCALE: J ELi� ..LN Klamath Falls,OR.97601 conditions. For the complete installation procedure,see the instructions � .r ;'�, r: O � D.Vezo NTS Phone: (541)882-3451 packaged with the window or go to ED BY:w,Aw.jeld-wen.com/resourcesrinstallafion. _ * ?y * = j antola TITLE: DISCLAIMER: v T T L = APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider )344, This drawing and its contents are confidential and are not to be % O L 0� •46 : PARTIFRoiETT No. Masonry Installation(74"x 54") reproduced or copied in whole or in part or used or disclosed to others � o a $- DOE,% except as authorized b JELD-WEN Inc. gee Erd�t WM ,we IDEHRFIER Na PANT NAME AJND L=1111N: CAD DwG.No, REV: SHEET p y e O NCTL210-3896- FBC 30=+ MIN DISTA— STEEL INSTALLATION FOR EDGE 112' Min—bed n1 2 000-M .14"HIM SPACE t MIN DISTAWE FOR EDGE 1/2- *�I"4'MMA MAXX t frame SPACE M;.—bA—m 3 P.,ar ....... ------------ WWM JAMB 5ECTION(TYP) FRAME SECTION(TYP) HORIZONTAL 5ECTION VERTICAL SECTION T T L� L-T = SHIM SPACE 2 WNDOW WVM(74' TYPICAL ELEVATION WITH FASTENER SPACING 2 f— Max Frame OP RATING PAM MIN DISTANCE 74 x 54 +50/-55 1 YES 1: FOR EbZoE W' General Notes: Installation Notes: 1. Sea]Range/frame to substrate, 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. For anchoring into metal framing use#10 TEK Sell Tapping screws with sufficient length to achieve a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida minimum embedment of three threads past the frame thickness. Steel substrate min.1 8ga.,fy=33 ksi Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to property transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 3 ram annealed 111 min airspace 13 ram annealed 12 min PVB by project of installation. Dupont 13 min annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does ♦ 0r-— ,. , - not address the sealing consideration that may arise in different wall PRO)ECr UrGWIER: DATE: 01/30/2014 j3M.113VOr 3737 Lakeport Blvd 4' #MN ge conditions. For the complete installation procedure,see the instructions ♦ ':t� C) DRAWN BY: SCALE: Klamath Falls,OR.97601 D.Vezo NTS Phone: (541)882-3451 packaged with the window or go to 7 -A -5iECED BY TITLE: Ym,%v.jeld-wen.com/resourcesrinstallaflon. * J.Ka DISCLAIMER: X Z: APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider - This drawing and its contents are confidential and are not to be 46 % PARUROIECTPW Steel Installation(74"x 54") reproduced or copied in whole or in part or used or disclosed to others .8 ID 09346 except as authorized by JELD-WEN Inc. 398 338 E AND LOCATION�CAD DWG. I REV. 1SHEET NCTL210 3896- 'F'BC' IDINT11151 11, NAIL FIN INSTALLATION 1 V21 AUN MSEDMENT 1.2r 2 tXWOOD FRAME I MIN.DISTANCE FOR EDGE!314" MIN.DISTANCE FOR EDGE. 2X W, -D FRAME 1/4'MAX T au IV 54TM SPACE rN 2 1/4'MAX SHIM SPACE 30 1.o mm 1 1/2"MIN EMBEDMENT J 4 GLASS.1E - ------------ FRAM JAMS SECTION(TYP) VERTICAL SECTION E SECTION(TYP) HORIZONTAL SECTION SHIM SPACE ".0"TIMM CW MIN DISTANCE FOR ED1;E 3/4' TYPICAL ELEVATION WITH FASTENER SPACING 2X WOM FQAME ; i[�aX Frame N RATING jMPACT I IZ' E.SFU ENT 74 x 54 50/-55 YES Installation Notes: General Notes: 1. Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use#10 PH or greater fastener though the nail fin with sufficient length to penetrate a minimum of 1 of the adopted International Building Code(IBC).the International Residential Code(IRC).the Florida 1/2"into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Cocle(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 2. All glazing shall conform to ASTM El 300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 3 mm annealed 111 mm airspace 13 mm annealed 12 mm PVB by project of installation. Dupont/3 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind bome debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations .1%1%�' Maximum sizes are buck sizes and do not include fin or flange. noted. it is not intended as a guide to the installation process and does ox-- 11 PRO)ECT ENGINEER: DATE: not address the sealing consideration that may arise in different"fall 01/3012014 3737 Lakeport Blvd conditions. For the complete installation procedure,see the instructions • SCALE: JUDVENKlamath Falls,OR.97601 D.Vezo NTS Phone: (541)882-3451 packaged with the window or go to 7 -E— "w,jeld-wen-com/resourcesrinstallation. M�ED BY TITLE: 3.Kantola APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider DISCLAIMER: Nail Fin Installation(74"x 54") This drawing and its contents are confidential and are not to be D PARROIECT N.C reproduced or copied in whole or in part or used or disclosed to others Ile a %, b 09346 except as authorized by JELD-WEN Inc. 398 IDENTIFIER 14n CAD DWG.N- REV: SHEET I OF rNCTI-210-3896-�-WFBF"�E AND'.".": - --- - THROUGH FRAME INSTALLATION MIN DI5TANC-E FG.EDGE.3/4'3 . MAX ARYL i 2 1 112-MIN. EMBEBEDMMEM i i 1/2'MIN- EMBEDMENT 1/4'MAX VA.MAX i 1 II SHIM SPACE 3 SHIM 51ACE )urx•ao. I 1 uAx.Mau �7 mA1a 1J zo�, 3R. FOR EDGE 3/4 ----------- MIN.DISTANCE 2 i r � I DCH 935 1 zurn�DPUT. JAMB SECTION(TYP) I � FRAME SECTION(TYP) HORIZONTAL SECTION _ VERTICAL SECTION L"MAx L-T T T --�1111 SHIM SPACE I 3 ----------.� .------ rumor WoD,CFO Mm) - -- TYPICALELEVATION WITH FASTENER SPACING EMBEDMENT Max Frame DP RATING IMPACT FOQ D:E 3Y4' i 74 x 54 FDR EDC+E L,- +50/-55 1 YES Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use#10 PH or greater fastener though the jamb with sufficient length to penetrate a minimum of 1 1/2' of the adopted Intemational Building Code(IBC).the International Residential Code(IRC).the Florida into the wood framing. For 2X wood frame substrate(min.S.G.=0.42). Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to property transfer all loads 2. All glazing shall conform to ASTM E1300. to the structure. The host structure is the responsibility of the architect or engineer of record for the 3. At minimum,glazing shall be 3 mm annealed 111 mm airspace 13 mm annealed/2 mm PVB by project of installation. Dupont/3 mm annealed. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations ��� tt t 1 t t t /// 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does PRoXCT ENGINEER: Dare i 3737 Lakeport Blvd not address the sealing consideration that may arise in different wall C� . 02/03/2014 Y C conditions. For the complete installation procedure,see the instructions r�;'���•• .�� : DRAWN BY: SCALE: " Klamath Falls,OR.97601 D.Vezo NTS Phone: 541 882-3451 packaged with the window or go to �j 7 ( ) CHECKED BY: TITLE: www.jeld-wen.com/resourcesfinstallation. _ * * — J.Kantola DISCLAIMER: T T = APPROVED BY: Premium Atlantic Vinyl Impact Horizontal Slider This drawing and its contents are confidential and are not to be �%�� C 0� �4: PART o E r No. Through Frame Installation(74"x 54") reproduced or copied in whole or in part or used or disclosed to others � a No l���� DU0� 4fj except as authorized by JELD-WEN Inc. aee F�Cpt YO1tE.9'.Me I IDENTIFIER N" PWJT N0.IE AND LOCATION: CAD DING.Na.: Rft': SNEEi a (�{ NCTI-210-3896- -FBIC of M:N G[StptYE MASONRY INSTALLATION I f04 FGGE.z vz• c sLK 2 xp! w7s•ox- &s•WAL i -f® I 1IJt'M[N. 4 •6 3 EpIBa.UMEt� �l 1 t44'MLN EMBEDMENT mAx It.'MpX 3 !NIM SGACF Ir{,S7p• I SMM:rOrCE MIN GISTp!:CE rRA+a ' `'t-- i coo EWbE z ur ° c mAsowy BLOCC - j °- ° ' JAMB SECTION(TYP) ' "12`i'DGapt' I HORIZONTAL 5ECTION FRAME SECTION(TYP) VERTICAL SECTION T T T ( 1 If4 M x 5,11M VACE' TYPICAL ELEVATION WITH FASTENER 5PACIN& ' o 2 1114-MN i EMa{GM{,+T I ` Max Frame N RATING IMPACT i 3 - s spsonRr 74 x 54 +50/-55 YES j strxc i Fm EDAE DISTpF#'E Installation Notes: General Notes: 1. Seal flangelframe to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load Criteria 2. Use 3?16"Tapcon or equivalent fasteners through frame with sufficient length to penetrate a minimum of the adopted International Building Code(IBC)•the International Residential Code(IRC).the Florida of 1 114"into concrete or masonry at each location with a 2 112"min from edge distance.For concrete Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. (min.fc=3000psi)or masonry substrate(CMU shall adhere to ASTM C90). 2. All glazing shall conform to ASTM E1300. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to property transfer all loads 3. Al minimum.glazing shall be 3 mm annealed 111 mm airspace 13 mm annealed'2 mm PVB by to the structure. The host structure is the responsibility of the architect or engineer of record for the Dupont 13 mm annealed. project of installation. 4. Use structural or composite shims where required. 5. Installation methods can be interchanged within the same opening. 6. An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations %tt t I I f 1l 11�i 7. Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does "V i� PRO)ECT E7 O VEER: DATE: not address the sealing consideration that may arise in drfterent wall ��� C� ��� Ol/30/2014 ��yA ��j 3737 Lakeport Blvd conditions. For the complete installation procedure,see the instructions ��;' �� y DRAWN BY: SG1LE: J���ja ��j�j\ Klamath Falls,OR.97601 packaged with the window or go to t�I }_y{\7J D.Vezo NTS Phone: (541)882-3451 •�7 '; CHECKED BY: TITLE: wwvw.jeld-wen.com/resourcesrinstallafion. _ * * = J.Kantola DISCLAIMER: APPRoveDBr: Premium Atlantic Vinyl Impact Horizontal Slider This drawing and its contents are confidential and are not to be :�O P;' �� Masonry Installation(74"x 54") C D PART PROtECT FJo- reproduced or copied in whole or in part or used or disclosed to others � a��p8�• Y66M 6 except as authorized by JELD-WEN Inc. see tpt a 1ddb�l LiiZ sae IDENTIFIER Na PANT NAh1E-1)LOCATION: CAC DWG.II., REb'; SHEE NCTL210-3896- FBC ICE STEEL INSTALLATION MIN 111-AI41 FOR 50GE V2' 2 15W d'h'.lh­ds tux F.W FftV 00man 3 eel Slud �.14.M X ,MAX IHI.lcE SHIM SPACE MIN bISTANCE FRWE zza': FOR EDGE I/Z" *2 0 M; �­t ae b _ds 3 S'W 11%11 MAX 5 SPACE ------------ t55 AT, A - DOW YM JAMB SECTION(TYP) FRAME SECTION(TYP) HORIZONTAL SECTION VERTICAL SECTION LT T T 11.1 MAX � S.VA 5PACE te 9-ge WPOM ROM(74-MM) SW TYPICAL ELEVATION WITH FASTENER SPACING 2 hre. Max Frame UP RATING �l f MIN DISTANCE 74 x 54 +50/-55 YES FOR ENE.— General Notes: Installation Notes:I. Seal flange/frame to substrate, 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. For anchoring into metal framing use 910 TEK Self Tapping screws with sufficient length to achieve a of the adopted Intemational Building Code(IBC),the International Residential Code(IRC),the Florida Building Gode(FBC)including HVHZ and the industry requirement for the stated conditions. minimum embedment of three threads past the frame thickness. Steel substrate min.18ga.,Ify=33 ksi. 2. All glazing shall conform to ASTNI E 1300. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 1 Al minimum,glazing shall be 3 mm annealed 111 Trim airspace 13 mm annealed/2 mm PVB by to the structure. The host structure is the responsibility of the architect or engineer of record for the project of installation. Dupont 13 mm annealed. 4. Use structural or composite shims where required- 5. Installation methods can be interchanged within the same opening. & An impact protective system is not required where wind borne debris protection is mandated by local This schedule addresses only the fasteners required to anchor the building code. window to achieve the rated design pressure up to the size limitations Maximum sizes are buck sizes and do not include fin or flange. noted. It is not intended as a guide to the installation process and does '110 PROIECT ENGINEER: DATE: not address the sealing consideration that may arise in different wall 0 01 1/30/2014 3737 Lakeport Blvd conditions. For the complete installation procedure,see the instructions I MAlvv BY: SCALE: ff-LDWENKlamath Fails,OR.97601 packaged with the window or go to 7 D.Vezo NTS Phone: (S41)882-3451 %ww.jeld-wen.corairesourcesrinstallafion. CHEUED BY: TITLE: J.Kantola DISCLAIMER: -10 T T = APPROVED BY: -Premium Atlantic Vinyl Impact Horizontal Slider This drawing and its contents are confidential and are not to be _ 0 % 0 p- Pbrd�4&' Steel Installation(74"x 54") 6 reproduced or copied in whole or in part or used or disclosed to others ole a 0. except as authorized by JELD-WEN Inc. 398 3W IDENTIFIER N. �—NAME AID—11-: CAD DWG.No.: REV: SHEET a NCrL210-3896- F BC 398 E. Dania Beach Blvd. BUILDING DROPS Suite 338 Dania Beach, FL 33004 A Perfect Solution in� Every Drop 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com Product Ev,,r-11LI'Iltion Report Of JELD-WEN, inc. Premium Atlantic Vinyl 8200 Horizontal Sliding Window .for Florida Product Approval Report No. 31,01. Current Florida Building Code Method: 1 — A (Certificate) Category: Windows Sub — Category: Horizontal Slider Product: Premium Atlantic Vinyl 5200 Hwizontal Sliding Material: PVC Product Dimensions: 74"x 54"(W) Prepared For: JEA.D-WEN, itic. 3737 Lalsepoi-t Blvd. KJaiiiatli 14'alls, OR 97€01 DES F. O Prepared by: ���.•��• _•F� 1-let- u s 1�. Norero. 1'.E. O - 7 /'• Florida Professional Engineer#73778 — Date: 05/12/2015 = v T T = Contents: --•••. .•• \ Evaluation Report Paves 1 - t A1- G`��` ` Hermes F. Norero, P.E. Florida No. 73778 BUILDING DROPS Date: 0015 Report Noo:: 3101 . A Perfect Solution in Every Drop Certificate of Authorization:29578 Manufacturer: JELD-WEN, inc. Product Category: Windows Product Sub-Category: Horizontal Slider Compliance Method: State Product Approval Method (1)(a) Product Name: Premium Atlantic Vinyl 8200 Horizontal Sliding Window (Impact) 74" x 54" (XO) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN, inc. based on Method 1a of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3896-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL# 73778) for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing NCTL210-3896-1-FBC require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions NCTL210-3896-1-FBC for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 BUILDING DROPS Date: O 015 Report Noo:: 3101 r A Perfect Solution in Every Drop Certificate of Authorization:29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation & Management Institute (FBC Organization#: QUA1789). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories, Inc. (FBC Organization# TST1589) Report#: NCTL 210-3896-1, Report Date: 11/22/13 2. Certification Agency National Accreditation&Management Institute (FBC Organization#: CER1773) 3. Material Certification Miami Dade RER—Product Control Section NOA E.I. DuPont De Nemours&Co., Inc.: PVB Interlayer 4. Material Certification Miami Dade RER—Product Control Section NOA Quanex Building Products: PVC Extrusions Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 Date: 0 o: 31015 BUILDING DROPS � Report No: 01 3 A Perfect Solution in Every Drop Certificate of Authorization:29578 Installation: 1. Approved anchor types and substrates are as follows: Through Frame Installation: A. For wood substrates use (1)#10 Wood Screw type anchor per location of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. B. For concrete or masonry substrate where one by(1X), non-structural,wood bucking is employed, use(1)3/16" diameter ITW Tapcon type concrete screw anchors per loation of sufficient length to achieve minimum embedment of 1.25"into concrete or masonry. C. For concrete or masonry substrate where wood bucking is NOT employed, use (1) 3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. D. For steel substrate, use (1)#10 Tek Screw type steel frame anchors per location of sufficient length to achieve minimum three threads of penetration beyond steel structure. Nail Fin Installation: A. For wood substrates use (1)#10 Wood Screw type anchor per location of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. Refer to Installation Instructions(NCTL210-3896-1-FBC)for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Positive 50 PSF Negative 55 PSF Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4 398 E. Dania Beach Blvd. BUILDING DROPS Suite338 A Perfect Solution in Every Drop Dania Beach, FL 33004 -1 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@ buildingdrops.com Product Evaluation Report of JELD-WEN, inc. Premium Atlantic Vinyl 8200 Horizontal Sliding Window for Florida Product Approval Report No. 3101 Current Florida Building Code Method: 1 — A (Certificate) Category: Windows Sub — Category: Horizontal Slider Product: Premium Atlantic Vinyl 8200 Ilorizontal Sliding Material: PVC Product Dimensions: 74"x 54"(XO) Prepared For: •ELD-WEN, inn. 3737 Lakeport Blvd. Prepared by: ��,Q;.•��•...�. ,' ,A ; ° Florida Professional Engineer#73778 Date: 05/12/2015 F Contents: Evaluation Report Pages 1 -4 ��i�`s`s/ANAL E� N� 'J���//11111►���� Hermes F. Norero, P.E. Florida No. 73778 BUILDING DROPS Date: 05/12/2015 Report No: 3101 A Perfect Solution in Every Drop Certificate of Authorization:29578 Manufacturer: JELD-WEN,inc. Product Category: Windows Product Sub-Category: Horizontal Slider Compliance Method: State Product Approval Method (1)(a) Product Name: Premium Atlantic Vinyl 8200 Horizontal Sliding Window (Impact) 74" x 54" (XO) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778) for JELD-WEN, inc. based on Method la of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3896-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL# 73778) for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing NCTL210-3896-1-FBC require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions NCTL210-3896-1-FBC for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 4 BUILDING DROPS Date: 0 015 Report Noo:: 3101 ' A Perfect Solution in Every Drop �r Certificate of Authorization:29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation & Management Institute (FBC Organization#: QUA1789). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories, Inc. (FBC Organization# TST1589) Report#: NCTL 210-3896-1, Report Date: 11/22/13 2. Certification Agency National Accreditation&Management Institute (FBC Organization #: CER1773) 3. Material Certification Miami Dade RER—Product Control Section NOA E.I. DuPont De Nemours&Co., Inc.: PVB Interlayer 4. Material Certification Miami Dade RER—Product Control Section NOA Quanex Building Products: PVC Extrusions Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 4 BUILDING DROPS Date: O 015 Report Noo:: 3101 r A Perfect Solution in Every Drop Certificate of Authorization:29578 Installation: 1. Approved anchor types and substrates are as follows: Through Frame Installation: A. For wood substrates use (1)#10 Wood Screw type anchor per location of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. B. For concrete or masonry substrate where one by (1X), non-structural,wood bucking is employed, use(1)3/16"diameter ITW Tapcon type concrete screw anchors per loation of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For concrete or masonry substrate where wood bucking is NOT employed, use (1) 3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. D. For steel substrate, use (1) #10 Tek Screw type steel frame anchors per location of sufficient length to achieve minimum three threads of penetration beyond steel structure. Nail Fin Installation: A. For wood substrates use (1)#10 Wood Screw type anchor per location of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. Refer to Installation Instructions (NCTL210-3896-1-FBC)for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Positive 50 PSF Negative 55 PSF Hermes F. Norero, P.E. Florida No. 73778 Page 4 of 4