Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 23 Phase 3 Waterstone 2265 CRGL Street: 8308 Amalfi Circle City, State, Zip: Fort Pierce , FL , 34951 Owner: Design Location: FL, ST_LUCIE_CO_INTL Builder Name: ADAMS HOMES Permit Office: Permit Number: Jurisdiction: 661000 County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�2018.2 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1378.30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Exterior R=13.0 407.83 ft2 4. Number of Bedrooms 4 c. Frame -Wood, Adjacent d. N/A R=13.0 232.00 ft2 5. Is this a worst case? No 11. Ceiling Types (2377.0 sgft.) R= ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 2277 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 2277.00 ft2 R=19.0 Conditioned floor area below grade (ft2) 0 c. N/A 100.00 ft2 R= ft2 7. Windows(293.9 sgft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 166.06 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 456.2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: 70.92 ft2 13. Cooling systems kBtu/hr Efficiency SHGC=0.21 c. U-Factor: Dbl, U=0.55 35.56 ft2 a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 5.160 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.288 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 SHGC(AVG): N/A 15. Hot water systems 9. Floor Types (2277.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.129 Total Proposed Modified Loads: 66.38 PASS Total Baseline Loads: 67.80 I hereby certify that the plans this calculation are in compliE Code. PREPARED BY: r DATE: _ r1749-2021 Winn Kpm;;ny covered I hereby certify that this building, as designed, is in compliance with the Florida d OWNER/AGENT: DATE: - - Revievftf the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: - %,umpnance requires certitication by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air,, Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/2/2021 9:27 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-2020 IAIPI IT CI IRA11AAOV f%UCf%W. INT nrn.,r,T ..�.�. v.. VVr\VIVI FNCrVltl PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 23 Phase 3 Waterstone 2 Bedrooms: 4 User Conditioned Area: 2277 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Lot Information 23-3 Waterstone 8308 Amalfi Circle St. Lucie Fort Pierce , FL, 34951 CLIMATE / v Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH _MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 2277 20493 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2277 20493 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0 2277 ftz ---- 0.35 0 0.65 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Barr Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or Shed Composition shingles 2546 ftZ 570 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2277 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2277 ftZ 0.11 100 ftZ 0.11 Wood Wood 7/2/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 t-UKM K4U5-2U20 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 W Exterior Frame - Wood Main 13 10 2 8 0 81.3 ft2 0 0.23 0.6 0 2 W Exterior Concrete Block - Int Insul Main 4.1 38 7 10 0 385.8 ft2 0 0 0.6 0 3 S Exterior Frame - Wood Main 13 4 6 10 0 45.0 ft2 0 0.23 0.6 0 4 S Exterior Concrete Block - Int Insul Main 4.1 28 6 10 0 285.0 ft2 0 0 0.6 0 5 E Exterior Frame - Wood Main 13 6 9 8 0 54.0 ft2 0 0.23 0.6 0 6 E Exterior Concrete Block - Int Insul Main 4.1 50 3 8 0 402.0 ft2 0 0 0.6 0 7 NE Exterior Frame - Wood Main 13 3 10 10 0 38.3 ft2 0 0.23 0.6 0 8 NE Exterior Concrete Block - Int Insul Main 4.1 0 5 10 0 4.2 ft2 0 0 0.6 0 9 N Exterior Frame - Wood Main 13 18 11 10 0 189.2 ft2 0 0.23 0.6 0 10 N Exterior Concrete Block - Int Insul Main 4.1 37 8 8 0 301.3 ft2 0 0 0.6 11 - Garage Frame - Wood Main 13 29 0 8 0 232.0 ft2 0 0.23 0.01 0 0 DOORS Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 - Wood Main None .25 2 8 6 8 17.8 ft2 2 E Insulated Main None .25 2 4 6 8 15.6 ft2 3 S Insulated Main None .25 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 23 ft 0 in 0 ft 9 in Drapes/blinds None 2 W 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 S 3 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft2 12 ft 8 in 0 ft 6 in None None 4 S 4 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 12 ft 8 in 2 ft 10 in None None 5 S 4 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 6 S 4 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 0 in 2 ft 10 in Drapes/blinds Exterior 5 7 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 8 E 6 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 9 NE 7 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 11 ft 0 in 0 ft 4 in Drapes/blinds Exterior 5 10 N 9 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 4 in 0 ft 9 in Drapes/blinds None 11 N 9 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft2 6 ft 8 in 0 ft 4 in Drapes/blinds Exterior 5 12 N 9 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 4 in 0 ft 4 in Drapes/blinds Exterior 5 13 N 9 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 14 S 4 Vinyl Low-E Double Yes 0.33 0.31 N 3.0 ft2 1 ft 0 in 1 ft 10 in Drapes/blinds None 7/2/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 IAIDI IT C1111Annnov .c+T r■•-■.... �■•�� vl "%.,F%L.1■7 1 RCrVI[ 1 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 617ft2 617ft2 64ft 8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2390.9 131.17 246.26 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing] SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 456.2 ft Main 114.05 Default Leakage Main (Default) (Default) 1 1 7/2/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 IAIPI IT CI IMI►eAnv f%U0f%W1 1@'r n�n.,r,T ...--.... v.I F%"V VR 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Heating Jan Venting Jan Feb Feb Mar Mar Apr APr [ [ j May ]May Jun rj Jun Jul Jul ri Au jXj AuSep rl Se Oct Oct Nov Dec Dec Feb X Mar [X] A r [ ] Ma Jun Jul Aug Se [)C) Oct XNov X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 7/2/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 j M FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 8308 Amalfi Circle, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1378.30 ft2 • 3. Number of units, if multiple family 1 b. Frame - Wood, Exterior R=13.0 407.83 ft2 c. Frame - Wood, Adjacent R=13.0 232.00 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area 6. Conditioned floor area (ft2) 2277 a. Under Attic (Vented) b. Knee R=30.0 2277.00 ft2 Wall (Vented) R=19.0 100.00 ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 166.06 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 456.2 b. U-Factor: Dbl, U=0.33 70.92 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 35.56 ft2 a. Central Unit 35.0 SEER:16.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 21.33 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 5.160 ft. a. Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average SHGC: 0.288 8. Skylights Description Area 15. Hot water systems . a. U-Factor(AVG): N/A ft2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ftZ None b. N/A R= ft2 Credits (Performance method) Pstat c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: _ Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. ""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/2/2021 9:27 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1