FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
Lot 23 Phase 3 Waterstone 2265 CRGL
Street:
8308 Amalfi Circle
City, State, Zip:
Fort Pierce , FL , 34951
Owner:
Design Location:
FL, ST_LUCIE_CO_INTL
Builder Name: ADAMS HOMES
Permit Office:
Permit Number:
Jurisdiction: 661000
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Type�2018.2 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1378.30 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Exterior
R=13.0 407.83 ft2
4. Number of Bedrooms
4
c. Frame -Wood, Adjacent
d. N/A
R=13.0 232.00 ft2
5. Is this a worst case?
No
11. Ceiling Types (2377.0 sgft.)
R= ft2
Insulation Area
6. Conditioned floor area above grade (ft2)
2277
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0 2277.00 ft2
R=19.0
Conditioned floor area below grade (ft2)
0
c. N/A
100.00 ft2
R= ft2
7. Windows(293.9 sgft.) Description
Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33
166.06 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC:
70.92 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC=0.21
c. U-Factor: Dbl, U=0.55
35.56 ft2
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 5.160 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.288
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights
Area
c. U-Factor:(AVG) N/A
ft2
SHGC(AVG): N/A
15. Hot water systems
9. Floor Types (2277.0 sgft.)
Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 2277.00 ft2
b. Conservation features
EF: 0.940
b. N/A
R= ft2
None
c. N/A
R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.129
Total Proposed Modified Loads: 66.38
PASS
Total Baseline Loads:
67.80
I hereby certify that the plans
this calculation are in compliE
Code.
PREPARED BY: r
DATE: _ r1749-2021 Winn Kpm;;ny
covered
I hereby certify that this building, as designed, is in compliance
with the Florida d
OWNER/AGENT:
DATE: - -
Revievftf the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
- %,umpnance requires certitication by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air,, Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
7/2/2021 9:27 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 IAIPI IT CI IRA11AAOV f%UCf%W. INT nrn.,r,T
..�.�. v.. VVr\VIVI FNCrVltl
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 23 Phase 3 Waterstone 2 Bedrooms: 4
User Conditioned Area: 2277
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Lot Information
23-3
Waterstone
8308 Amalfi Circle
St. Lucie
Fort Pierce ,
FL, 34951
CLIMATE
/
v Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH _MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2277 20493
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2277 20493 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0
2277 ftz ----
0.35 0 0.65
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2546 ftZ 570 ft2 Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2277 ftZ N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2277 ftZ 0.11
100 ftZ 0.11
Wood
Wood
7/2/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
t-UKM K4U5-2U20
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing
Solar
Below
1
W
Exterior
Frame - Wood
Main
13 10
2
8
0
81.3 ft2
0
0.23
0.6
0
2
W
Exterior
Concrete Block - Int Insul
Main
4.1 38
7
10
0
385.8 ft2
0
0
0.6
0
3
S
Exterior
Frame - Wood
Main
13 4
6
10
0
45.0 ft2
0
0.23
0.6
0
4
S
Exterior
Concrete Block - Int Insul
Main
4.1 28
6
10
0
285.0 ft2
0
0
0.6
0
5
E
Exterior
Frame - Wood
Main
13 6
9
8
0
54.0 ft2
0
0.23
0.6
0
6
E
Exterior
Concrete Block - Int Insul
Main
4.1 50
3
8
0
402.0 ft2
0
0
0.6
0
7
NE
Exterior
Frame - Wood
Main
13 3
10
10
0
38.3 ft2
0
0.23
0.6
0
8
NE
Exterior
Concrete Block - Int Insul
Main
4.1 0
5
10
0
4.2 ft2
0
0
0.6
0
9
N
Exterior
Frame - Wood
Main
13 18
11
10
0
189.2 ft2
0
0.23
0.6
0
10
N
Exterior
Concrete Block - Int Insul
Main
4.1 37
8
8
0
301.3 ft2
0
0
0.6
11
-
Garage
Frame - Wood
Main
13 29
0
8
0
232.0 ft2
0
0.23
0.01
0
0
DOORS
Ornt Door Type
Space Storms U-Value
Width
Ft In
Height
Ft In
Area
1
- Wood
Main None .25
2 8
6 8
17.8 ft2
2
E Insulated
Main None .25
2 4
6 8
15.6 ft2
3
S Insulated
Main None .25
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
W
1
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft2
23 ft 0 in
0 ft 9 in
Drapes/blinds
None
2
W
2
Vinyl
Low-E Double
Yes
0.33
0.23
N
32.4 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
3
S
3
Vinyl
Low-E Double
Yes
0.33
0.31
N
5.0 ft2
12 ft 8 in
0 ft 6 in
None
None
4
S
4
Vinyl
Low-E Double
Yes
0.33
0.31
N
13.3 ft2
12 ft 8 in
2 ft 10 in
None
None
5
S
4
Vinyl
Low-E Double
Yes
0.33
0.21
N
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
6
S
4
Vinyl
Low-E Double
Yes
0.33
0.21
N
38.5 ft2
1 ft 0 in
2 ft 10 in
Drapes/blinds
Exterior 5
7
E
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
9.8 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
8
E
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
16.2 ft2
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
9
NE
7
Vinyl
Low-E Double
Yes
0.33
0.23
N
12.5 ft2
11 ft 0 in
0 ft 4 in
Drapes/blinds
Exterior 5
10
N
9
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft2
9 ft 4 in
0 ft 9 in
Drapes/blinds
None
11
N
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
16.7 ft2
6 ft 8 in
0 ft 4 in
Drapes/blinds
Exterior 5
12
N
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
30.0 ft2
9 ft 4 in
0 ft 4 in
Drapes/blinds
Exterior 5
13
N
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
48.6 ft2
1 ft 0 in
1 ft 2 in
Drapes/blinds
Exterior 5
14
S
4
Vinyl
Low-E Double
Yes
0.33
0.31
N
3.0 ft2
1 ft 0 in
1 ft 10 in
Drapes/blinds
None
7/2/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 IAIDI IT C1111Annnov .c+T r■•-■....
�■•�� vl "%.,F%L.1■7 1 RCrVI[ 1
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
617ft2
617ft2
64ft 8ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.0004
2390.9 131.17 246.26 .1324 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.5 34.6 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Sing] SEER: 16 35 kBtu/hr cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert #
Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None
None
ft2
DUCTS
/
#
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
Attic 6 456.2 ft
Main
114.05 Default Leakage Main (Default) (Default)
1 1
7/2/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 IAIPI IT CI IMI►eAnv f%U0f%W1 1@'r n�n.,r,T
...--....
v.I F%"V VR 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan
Heating Jan
Venting Jan
Feb
Feb
Mar
Mar
Apr
APr
[
[
j May
]May
Jun
rj Jun
Jul
Jul
ri
Au
jXj AuSep
rl Se
Oct
Oct
Nov
Dec
Dec
Feb
X Mar
[X] A r
[
] Ma
Jun
Jul
Aug
Se
[)C) Oct
XNov
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
80
80
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
7/2/2021 9:27 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
j M
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
8308 Amalfi Circle,
Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1378.30 ft2
•
3. Number of units, if multiple family
1
b. Frame - Wood, Exterior
R=13.0
407.83 ft2
c. Frame - Wood, Adjacent
R=13.0
232.00 ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
6. Conditioned floor area (ft2)
2277
a. Under Attic (Vented)
b. Knee
R=30.0
2277.00 ft2
Wall (Vented)
R=19.0
100.00 ft2
7. Windows- Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
166.06 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
b. U-Factor: Dbl, U=0.33
70.92 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
35.56 ft2
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.70
d. U-Factor: other (see details) 21.33 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
5.160 ft.
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average SHGC:
0.288
8. Skylights Description
Area
15. Hot water systems .
a. U-Factor(AVG): N/A
ft2
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
9. Floor Types
Insulation Area
b. Conservation features
a. Slab -On -Grade Edge Insulation
R=0.0 2277.00 ftZ
None
b. N/A
R= ft2
Credits (Performance method)
Pstat
c. N/A
R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: _ Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/2/2021 9:27 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1