HomeMy WebLinkAboutCompaction Test Lot 106-ds UES Project No: 3360.1800067.0000
A Universal Workorder No: 242862-1
Engineering Report Date: 08/19/2021
Sciences
Company
4'4T01VATIOX�P
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 -P: 772-924-3575 -F: 772-924-3580
In-Place Density Test Report
Client: D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician: Mark Rogers
1430 Culver Drive, NE Date Tested: 08/17/2021
Palm Bay, FL 32907
Project: CMT CREEKSIDE
Yorktown Drive & Okeechobee Road,Fort Pierce, St Lucie County, FL
Type of Test:
Area Tested: Lot 106 -9304 Potomac Dr. Fort Pierce Field: ASTM D-6938 Nuclear Gauge Method
Material: Backfill Laboratory: ASTM D1557 Modified Proctor
Reference Datum: 0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Maximum Optimum Field Dry Field Soil Pass
Test Density Moisture Density Moisture Compaction or
No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail
1 Northeast corner of lot 0-1 ft 118.6 10.8 114.5 10.5 97 Pass
2 Southwest corner of lot 0-1 ft 118.6 10.8 113.5 10.5 96 Pass
3 Center of lot 0-1 ft 118.6 10.8 113.0 10.5 95 Pass
Remarks:
Permit: 2105-0867
Reviewed By
GFA International, Inc
FBPE Registry No.4930
VINIC" Digitally signed by Thomas
\:Oa.PSOOGEN FMOR2 D
No 846 *" Montano:A01 41 00000001 7
°' U7
STATE OF 818498DCD000019A3
<(/
Date:2021.08.19 09:10:15
ONAI
-04'00'
Thomas Dominic Montano
Branch Manager
STATE OF FLORIDA
Professional Engineer No. 84146
This item has been digitally signed and sealed by Thomas Dominic
Montano on the date adjacent to the seal.Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
The in-place density tests were performed within the foundation/building pad footprint of the referenced residential lot.The test results either meet or exceed the
requirements of the FHA/HUD manual and the current edition of the Florida Building Code for soil compaction.The Contractor is responsible for maintaining the
tested soil sub grade in the same condition that existed at the time UES performed the referenced density tests. UES is not responsible if the tested area is
altered from the approved condition at the time of testing.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1