HomeMy WebLinkAboutDesign Calculations1� ;,°. Seats 111 easyseals.com DESIGN CALCULATIONS FOR TREASURE BAYARCADE RECENED 'UN O'3 202, Permitting Depanmen St, Lucle County 4'x10' SIGN CA131NET 6623 US 1— Ft Pierce �, ��/ �O �O� GENERAL NOTES: 1. Design is in accordance with the Florida Building Code 7th Edition (2020) for use within and outside the High Velocity Hurricane Zone (HVHZ). 2. Wind loads have been calculated per the requirements of ASCE 7-16 as shown herein. 3. These engineering calculations pertain only to the structural integrity of those systems, components, and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The existing host structure (if any) is assumed to be in good condition, capable of supporting the loaded system, subject to building department approval. No warranty, either expressed or implied, is contained herein. 4. System components shall be as noted herein. All references to named components and installation shall conform to manufacturer's or industry specifications as summarized herein. 5. Where site conditions deviate from those noted herein, revisions may be required or a separate site -specific engineering evaluation performed. 6. Aluminum components in contact with steel or embedded in concrete shall be protected as prescribed in the 2015 Aluminum Design Manual, Part 1. Steel components in contact with, but not encased in, concrete shall be coated, painted, or otherwise protected against corrosion. 7. Engineer seal affixed hereto validates structural design as shown only. Use of this specification by contractor, et. Al, indemnifies and saves harmless this engineer for all costs & damages including legal fees & apellate fees resulting from deviation from this design. RE)IfEWED FOR�;E CODE COpAPLIA C ]CIE COUNTY ST®L EOCC Index: Pg 1 Cover Pg 2 Wind Loads Pg 3 Anchor Design 111111111111 Enp-imle OMMIjn I valid z ' No.6 8 S ATE AN ` Ch r'I 1,"J - %04"W# 67382 Easy SeMsuulnaAuth # 31124 1200 N Federal Hwy, #200 Boca Raton, FL33432 Easel Sealls .com Page 1 Q) EasySeals ea ea"-m ASCE 7-16 Design Wind Loads WALL -MOUNTED SIGNS Building Specs V = 160 mph Basic wind speed (Vult) Exposure C Calculations a = 9.5 3-sec gust speed power law exponent zg = 900, Nominal ht. of atmos. boundary layer Gcpi = 0 Internal pressure coeff 160 mph - UP "C" WALL -MOUNTED SIGNS ASD WIND PRESSURES SIGN CENTER CORNER HEIGHT (Zone 4) (Zone 5) 15 ft 31.2 psf 39.7 psf 20 ft 33.2 psf 42.2 psf 25 ft 34.8 psf 44.2 psf 30 ft 36.1 psf 46.0•psf 35 ft 37.3 psf 47.5 psf 40 ft 38.4 psf 48.8 psf 45 ft 39.3 psf 50.1 psf 50 ft 40.2 psf 51.2 psf 55 ft 41.0 psf 52.2 psf 60 ft 41.8 psf 53.2 psf 70 ft 35.3 psf 70.6 psf 80 ft 36.3 psf 72.6 psf 90 ft 37.2 psf 74.5 psf 100 ft 38.1 psf 76.1 psf 110 ft 38.8 psf 77.7 psf 120 ft 39.6 psf 79.1 psf 130 ft 40.2 psf 80.5 psf 140 ft 40.9 psf 81.7 psf 150 ft 41.5 psf 82.9 psf 175 ft 42.8 psf 85.7 psf 200 ft 44.1 psf 88.1 psf 250 ft 46.2 psf 92.3 psf CALCULATIONS FOR WALL -MOUNTED SIGNS ASD Load Combo Coeff: 0.6 Kd = 0.85 Directionality factor Kzt = 1.0 Topographic factor Ke = 1.0 Ground elevation factor A = 10 sq ft Tributary area Kh = Kz qz GCp (4) GCp (5) 0.85 28.4 -1.10 -1.40 0.90 30.1 -1.10 -1.40 0.95 31.6 -1.10 -1.40 0.98 32.8 -1.10 -1.40 1.01 33.9 -1.10 -1.40 1.04 34.9 -1.10 -1.40 1.07 35.8 -1.10 -1.40 1.09 36.6 -1.10 -1.40 1.12 37.3 -1.10 -1.40 1.14 38.0 -1.10 -1.40 1.17 39.2 -0.90 -1.80 1.21 40.4 -0.90 -1.80 1.24 41.4 -0.90 -1.80 1.27 42.3 -0.90 -1.80 1.29 43.2 -0.90 -1.80 1.32 44.0 -0.90 -1.80 1.34 44.7 -0.90 -1.80 1.36 45.4 -0.90 -1.80 1.38 46.1 -0.90 -1.80 1.42 47.6 -0.90 -1.80 1.46 48.9 -0.90 -1.80 1.53 51.3 -0.90 -1.80 Page 2 f seals eas"'ea'.m Wall Sign Anchor Design Structure Dimensions & Loading Design wind pressure: Sign type: Sign size: CALCULATIONS FOR WALL -MOUNTED SIGNS P = 46.0 psf Cabinet A = 40.0 sqft (entire cabinet) Wall material: Masonry (ASTM C90,1,500 psi min) Anchor type/size: 3/8" Large Diam Tapcon Ref: Red Head LDT, catalog Min Embedment: 1.5" Min edge dist: 4" Min Spacing: 4" Anchor tensile capacity: Tcap = 229.0 lb (per anchor) Check Anchors for Pullout Total Reaction: Rt = 1838 lb ... = P*A (entire cabinet) No. of anchors req'd: n = 8.0 total anchors ... = Rt/cap Total anchors required: 8 total anchors balanced over cabinet OK, typical/critical anchor option shown.. Limit to min (8) total. Ref anchor schedule for other anchor options. Page 3