Loading...
HomeMy WebLinkAboutGeneric PlansMAXIMUM ALLOWABLE FBC APPROVED PRODUCTS LIST TABLE 1 WIND SPEED . . RAFTER FRAMEEND P, OST,.GROUND ANCHOR AND .PANEL FASTENER SPACING SPECIFICATIONSOA APPROVAL PARTIALLY PRODUCT CATEGORY :SUB CATEGORY MANUFACTURER EXPIRATION AVERAGE FASTENER SPACING ON-CENTERSALONG RAFTERS OR No. & DATEDATEPE ENCLOSED ENCLOSED .E E D 01.80 N NC180 NC180 SE PU LINS; AND POSTS OR GIRTS 'STRUCTURAL COMPONENTS ROOF,DECK. CAROLINA CARPORTS, INC. FL6596:1-R6 . 04/05/27 MUM (INCHES) ULTIMATE NOMINAL POST 26 Gauge AG Panel. 12/15/20 WIND U N T RISK EXPOSURE WIND SPEED WIND SPEED SPACING INTERIOR END. STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. FL6702A-R6 03/14/27 180 1-80 180 CATEGORY CATEGORY (MPH) (MPH) .(FEET) POSTS/RAFTERS POSTS/RAFTERS 26 Gauge AG Panel 12/15/20 110 TO 150 TO 116 5.0 6 6 STRUCTURAL COMPONENTS, STRUCTURAL WALL CAROLINA CARPORTS, INC. FL6702.3-R6 03/14/27 N/A 164 143 C .89 26 Gauge Dutch Lap WaILPaneF 12/15/20 " 151 TO 180 117 TO 139 4.0 6 6. STRUCTURAL COMPONENTS FLOOD VENT CRAWL SPACE DOOR SYSTEMS, INC. FL29622.1-R1 09/30/22 N/A N/A N/A: NOTES: 1:'Specifications applicable_to 26 gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing; or 18 16x8 Flood Vent - 02/28/21 gauge hat channel roof purlins. 2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7" to 27° (1.5:12 to 6:12 pitch). Spacing EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL.COMPANY FL17996.3-R2 08/26/25 N/A 139 139 '. requirements for other roof heights and/or slopes may vary. . Series 402-14. 02/28/21 .. GROU.ND'ANCHOR SCHEDULE EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY FL17996.5-R2 08/19/25 . N/A 174 155 _ _ ." ULTIMATE WIND SPEED (RIPh) METAL CARPORT INSTALLATION, PLANS Series 407,02/28/21 110 120 -130 140 . •150 -160 170 180 AND DETAILS AND FRAMING AND' EXTERIOR DOORS ROLL -UP ASTA INDUSTRIES INC. FL8888.1-R6 12/31/21 N/A . 180 174 12 FASTENER SPECIFICATIONS' Model 203'(12' Max. Width) 02/09/21 • '14 30"Anchor EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC.' FL16806.1-R5 04/05/27 N/A. 179 154 -. Detaill D" FOR CONSTRUCTION IN THE STATE OF FLORIDA 12/16/20 Steel Roll Up Sheet Door (12''Max. Width) o 16 EXTERIOR. DOORS - - ROLL -UP CAROLINA CARPORTS, INC. N/A 180 180 E_-- 18 FL16806.2-R5 04/05/27 PREPARED FOR: CAROLINA CARPORTS, INC, Steel Roll -Up Sheet Door - (V Max. Width) 12/16/20 20 48"-Anchor P:O. BOX 1263 . .EXTERIOR -DOORS ROLL -UP CAROLINA CARPORTS, INC.. FC16806.3 R5 04/05/27 N/A 155 133. Detail lG z 22 O CAROLINA 12/16/20 -. Steel Roll -Up Sheet Door - (16''Max. Width) p 24 . FL16806.4 R 4/05/27 m 26 EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. 5 0 N/A 180 172 PREPARED BECHTOL ENGINEERING AND TESTING, INC. ` Steel Roll -Up Sheet Door - (10' Max. Width) 12/16/20 28 � 60 h :605 WEST NEW YORK AVENUE . FL17499 1 R8 10/ 7 2 WINDOWS SINGLE HUNG. MI WINDOWS AND DOORS -. 1 / 3 N/A 175 . 157 30 - I Detail 1Cr " DELAND; FLORIDA 32720' ' 1 rt t 0 5492 Ge 'fiq a of Authorization No. 000 11/27l20 .. Model185SH N - DETAILS 1C D SHOWN ON SHEET 4 OF 6 NOTES: '. 1. DOORS AND WINDOWS SHOWN MAY BE SUBSTITUTED FOR DIFFERENT PRODUCT LINES AND/OR MODELS, PROVIDED THE FOLLOWING CONDITIONS ARE MET; A. PRODUCT SHALL HAVE A VALID FBC PRODUCT APPROVAL. B. COMPONENTS ARE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION REQURIEMENTS- - "MAXIMUM POST SPACING FOR DUTCH LAPIS 4.0' REVIEWED FOR 2. FRAMING CONNECTIONS FOR DOOR AND WINDOW FRAMES REMAIN THE SAME FOR SUBSTITUTED PRODUCTS. HEADERS AND WINDOW RAILS MAY BE RAISED OR LOWERED AS NECESSARY TO ACCOMODATE SUBSTITUTED PRODUCT.CODE COMPLIANCE GENERAL NOTES: COUNTY 1 THESE PLANS PERTAIN, ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO I �IE THIS.IS T C fI T T E CALCULATIONSAND PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATION AND -SLOPE, OR OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. SPECIFICATIONS HEREIN B ARED BY THE 2• -THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITYIST"ORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS UNDERSIGNED PROFESSI0 AI N EER, AND ARE IN ACCORDANCE_ WITH THE REQUIREMENTS OF SECTION 1609 OF NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS OR OTHER COMPONENTS. NOT 'LISTED .IN THE:FBC APPROVED PRODUCTS LIST (THISSHEET), AND NOT PROVIDED AND INSTALED BY CAROLINA CARPORTS, . THE FLORIDA BUILDING CODE SEVENTH EDITION 2620. ( ) INC., WHICH.EXERT ADDITIONAL LOADS ON THE STRUCTURE SHALL BE AT THE OWNER'S RISK. BECHTOL ENGINEERING AND TESTING, INC.:. SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE-0 R FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS: 3• ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL OR ZINC PLATED.,. -. 4. ALL COMPONENTS AND -CLADDING. SHALL, BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND SHALL MEET THE DESIGN PRESSURES' REQUIRED BY THE FLORIDA BUILDING CODE (FBC) AT THE. t I I. nl P �, ! / LOCATION OF THE BUILDING WITHIN THE STATE OF FLORIDA. - 5. ALL FIELD FRAMING. CONNECTIONS SHALL BE #12-14 x 3/4" SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. @�CH tCENG11412 &I JESTING, INC. 6• CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 AXW1 .4 ed�1(� ES?NEW YORK AVENl1 ' �E NV, FLORID/}/ 2720 - WELDED WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER -REINFORCEMENT COMPLYING WITH ASTM C1116. -'� O 7. BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EVERY POST. LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING AND/OR CONCRETE SLAB CONSTRUCTION, SEE GROUND ANCHOR SCHEDULE (THIS SHEET) FOR SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS. _ zi LDT 1/2" 5" OR EQUIVALENT OR WEJ-IT ANKR-TITE MODEL.AT1252, ANCHOR MODEL HSA OR EQUIVALENT. O=h�s ee No. 8. CONCRETE ANCHORS SHALL BE TAPCON REDHEAD x OR SLEEVE 1260, - Pr9 ida �. g. POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION, EXCEPT FOR END WALLS. �... 10. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FBC SEVENTH EDITION (2020) - RESIDENTIAL, AND SECTION 1816.1 OF THE FBC /�l /hA1RQIA� IA SEVENTH EDITION (2020) - BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,000 PSF IS ASSUMED. CARPORTS, INC. 11. 14 GA FRAMING: 2-1/2"x 2-1/2" TUBE STEEL (TS) WITH 2-1/4" x 2-1/4" TS NIPPLES. GENERIC PLANS FOR USE IN THE STATE .OF FLORIDA 12 GA FRAMING: 2-1/4" x 2-1/4" TS WITH 2" x2" TS NIPPLES. 12. ENCLOSED AREAS REQUIRING FLOOD OPENINGS MUST HAVE A MINIMUM OF TWO (2) OPENINGS ON EXTERIOR WALLS. OPENINGS SHOULD BE INSTALLED ON AT LEAST TWO (2) SIDES OF ENCLOSED AREA, WITH BASE OF 01/05/2021 _BECHTOL_ENGINEERING °tAN"' mkb '"E' NTS OPENINGS SET WITHIN 1-FOOT OF THE HIGHER OF INTERIOR OR EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS NOTED IN THE FBC APPROVED PRODUCTS LIST SHALL BE BASED ON ONE (1)FLOOD VENT PER tb G21001 EVERY 305 SQUARE FEET OF ENCLOSED AREA. SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET 5 OF 6. - - TM° "L" MTERM"*��B •-��ismmarmxaa®m�a n�ckaT �_. B SHEET 1 OF 6. BOW FRAME RAFTER OPEN. CARPORT - HORIZONTAL ROOF BOW FRAME RAFTER ENCLOSED BUILDING = HORIZONTAL ROOF BOW FRAME RAFTER UTILITY. BUILDING = HORIZONTAL ROOF FLOOD VENT (As applicable) ROLL-UP.DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (As. applicable) (As applicable) (As applicable) _-5 4i77- _ F= — ENCLOSED LENGTH VARIES ---I - — TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE : NOT TO SCALE NOT TO SCALE BOX EAVE FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG - HORIZONTAL.ROOF BOX EAVE FRAME RAF. TER. UTILITY BLDG - HORIZONTAL ROOF FLOOD VENT,(As applicable) ROLL=UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (As applicable) (As applicable) (As applicable) . 6• Mill _ - ENCLOSED. LENGTH VARIES TYPICAL SIDE ELEVATION TYP.ICAL,END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION. TYPICAL SIDE ELEVATION' • TYPICAL END ELEVATION. -NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE BOX EAVE FRAME RAFTER OPEN CARPORT - VERTICAL ROOF BOX EAVE FRAME RAFTER ENCLOSED _BLDG - VERTICAL ROOF BOX EAVE FRAME RAFTER UTILITY BLDG - VERTICAL ROOF FLOOD VENT (As applicable). ROLL -UP DOOR SWINGING DOOR ROLL-UP.DOOR SWINGING -DOOR (As applicable) (As applicable) (As applicable)' ,(As applicable)' r7l MR� ZF �6' ENCLOSED LENGTH VARIES TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE O f TO SCALE' NOT TO. SCALE NOT TO SCALE NOT TO SCALE ZNEt:d� TBECKTOL TING, INC. 605 Wi;$T NEWYbRkADELkNl�L MDA 32720 S ' 3 C - r Thomas Florida i n5e No. i ORIDA (v I I I1jN `6ARPORTS, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA TYPICAL BOW RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER GABLE END ELEVATION 01/05/2021 AV BECHTOL ENGWNEERWNG °^""k mkb NTS NOT TO SCALE NOT TO SCALE NOT TO SCALE AND 1ES7ING, /ne ". tb G21001 ca'miaToio naeanu, onwuc®rrx. �w wrewn teamou .vvwxu TB . SHEET 2 OF 6 26 GA. GALVANIZED METAL ROOF PANELS 26 GA. GALVANIZED METAL ROOF. PANELS 26 IZED METAL ROOF PANELS FASTENED TO RAFTERS PER MANUFACTURER'S FASTENED TO RAFTERS PER MANUFACTURER'S MAFAS PURLINS PER NUFACTURER'S T INSTALLATION INSTRUCTIONS ' . - INSTALLATION INSTRUCTIONS TIO NINSTRUCTIONS, INSTALLAD y 3 2 1-U2' 18 GAUGE FURRING, 4 CHANNEL (PURLIN)24' 16GA EL BRACE 24' '16 GA U-CHANNEL BRACEFASTENEDER WITH FASTENED TO RAFTER WITH (2),#12-14 x's'AT (2)#12-14x3/4"SDFSAT - -. 24" 16GA'U-CHANNEL BRACESEEACH 7SDFA ENDRACE) _ EACH END (4 PER BRACE) FASTENED TO RAFTER WITH WJ (EACH 24'MAXIMUM RAFTER SPANRAFrER , .. p. "- 24' MAXIMUM RAFTER SPAN ON.SINGLE RAFTER. END 4 PERDBRACEw ( v >24' T0.30' RAFTER.SPAN REQUSSED RAFTER - >24' TO 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER C' AS SHOWN ON T r.AS SHOWN ON THIS SHEET RAFTER.'24t MAXIMUM. RAFTER SPAN ON SINGLE 24'"f0 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER;n.. .p AS SHOWN ONTHIS SHEET � a J t— TYPICAL- TYPICAL' INTERIOR RAFTER/POST RAFTER GABLE END FRAMING PLAN INTERIOR:RAFTER/POST FRAME SECTION'= BOW FRAME FRAME SECTION- BOX EAVE -HORIZONTAL ROOF TYPICAL INTERIOR .. NOTTYPICAL SCALE.W NOT TO SCALE NOT TO SCALE ' RAFTER/POST FRAME SECTION VERTICAL ROOF NOT TO SCALE .. .. 1 1/2' 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4" SELF -DRILLING. FASTENER SPACED. NOT MORE THAN 48" O.C. 5 ' SEJEA IMUM SEE FOR TABLE 1 SHEET jBL ETICAL1 OF6ONEL. . 3 � LEVA IES NG IRAFTERUMBER J AND SPACING OFDEPENDING TYPICAL RAFTER/POST FRAMING PLAN - BOW FRAME TYPICAL RAFTER/POST FRAMING PLAN - BOX EAVE.: TYPICAL " TYPICAL BOX EAVE RAFTER GABLE END FRAMING PLAN' NOT.TO SCALE NOT TO SCALE, POST/RAFTER FRAMING PLAN - VERTICAL ROOF . NOT TO SCALE T '. NO . TO SEE SEE TABLET. TABLE 1 OPENING FOR SWINGING _ SHEET SHEET DOOR WITH NON STRUCTURAL : 7- 1'OF 6 . 5 HEADER 5- .g ...q .. 4 .. .. .'13 .- .. .. 12' MAX. OPENING .. ' 6 q: 24" 16 GA U-CHANNEL BRACE z . FOR ROLL -UP DOOR 4 a FASTENED TO. RAFTER WITH. A 4. WITH STRUCTURAL °�N1NGF0R NGDOOR swlvrt"" 6. - (2) #12-14x 3/4" SELF -DRILLING' .. HEADER -' . _ _. ._ .. _ -. 1ROLL-XUP 4 .. .. .. SCREWS AT EACH END. .. . 10' (TYPICAL) .. _ _ .. _ - DOOR WITH - STRUCTURAL : ( BRACE) .. 4 PER ' .. _ 10. 4 .. 3 4. NONSTRUCTURAL _ .. LA S 4 4 4 q' .q 4 HEADER" - 4 4 . 4 . .. _ 4 q. . 4. . . .Ar A' - OPENING, OR WINDOW WITH - - NON-STRUCT DER TYPICAL ROOF EXTENSION'OPTION MAIN STRUCT\ f Vj I III 1 1 / / STANDARD LEAN-TO OPTION . WIRNODE kA IL TYPICAL_SIDE WALL OPENINGS FRAMING PLAN .. (Also applicable.to End Walls) END WALL OPENINGS POST/RAFTER: FRAMING PLAN .. G P H �/E NOT TO SCALE NOT TO SCALE' NOT TO ER SCALE (BOX EAVE RAFT SHOWN ON YQ IS_ ST TJDA P f0 BOW FRAME RAFTER) `e . ,C LIC � _ 24"'16•GA U-CHANNEL BRACE (5' TO T POST) 48".16 GA U-CHANNEL BRACE (8' TO 14' POST) BECk1T ' ENGINF� ING:A D T£�TING, INC. � BRACE ANGLE SHALL BE MIN. 30° . 605S EIN YORK AVE U18B DELANp CRIDA 3.2720 FULL 6" WELD BOTH SIDES � 6" �_� TO MAX. 45" FROM HORIZONTAL FULL 6" WELD BOTH SIDES — N •.. T— LENGTH VARIES DEPENDING ON NUMBER AND SPADING OF RAFTERS SEE - TABLE 1 SHEET OPTIONAL 24'71" TO 30.' TRUSSED RAFTER -BOW NOT TO SCALE,. LENGTH VARIES DEPENDING ON ' -NUMBER AND SPACING OF. RAFTERS SEE -TABLE 1 SHEET. 01/05/2021 A Mir WELD ALL WEB CONNECTIONS, v 'BOTH SIDES OPTIONAL 24'-1" TO 30' TRl1SSED RAFTER -BOX EAVE NOT TO. SCALE FREESTANDING LEAN-TO FRAMING PLAN NOT TO SCALE Thomas ffpc 1, .>=. O Florida Licetl�c_ CAOUNA C RPORTS, INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA BECHTOL ENGINEERING rnkb NITS AND 7ES7/N4 /nc tb G21001 c°rmiilem aco�awcu. einnora®rru.um unhwnteiEarnij eeoeEss ' . - . `-TB :SHEET 3 OF 6, , INSTALL 1/2' x MINIMUM 577APCON-REDHEAD LOT. INSTALL.1/2'x MINIMUM 5: TAPCON REDHEAD'LDT' ANCHOR OR 1/2' x MI EXPANSION ANCHOR ANCHOR OR 1/2' x MINIMUM 5-1l2' EXPANSION ANCHOR DRILL 5/8* HOLE THROUGH THE 2" WASHERS DRILL'5/8" HOLE THROUGH THE 2' WASHERS THROUGH BASE RAIL WITHIN 6" OF EACH THROUGH BASE RAIL WITHIN 6' OF EACH EYE BASE RAIL SECURE;TO BASE RAIL AND SECURE TO RAFTER POSTS ALONG SIDES AND EVERY END RAFTER POSTS ALONG SIDES AND EVERY END " ANCHOR EYE WITH 1/2' DIAMETER. TS CONTINUOUS ANCHOR E WITH 1/2' DIAMETER _ TS CONTINUOUS WALL POST ALONG END WALL SECTIONS "' - WALL POSTALONG'END WALL SECTIONS BASE RAIL BASE. RAIL " THROUGH -BOLT THROUGH -BOLT 4" MINIMUM . 2" MINIMUM MIN: 6' TOP OF ASPHALT PAVEMENT. TOP OF ASPHALT PAVEMENT _ O OR STABLE GROUND SURFACE R STABLE -GROUND SURFACE I MINIMUM 2-1/2" EMBEDMENT MINIMUM 2 1/2' EMBEDMENT CHOR 5/8 OD 48N LONG " WITH 6" HELIX OR 5l 12' 8" ROD 60",LONG , • MINIMUM 4'' WITH T HELIX, 5/8° � OD 30N LONG SCHEDULE; SHEET 1 OF 8 SEE GROUND ANCHOR SCHEDULE, SHEET 1 OF 6 r.. ., . HEL AS APPLICABLE FOR APPLICABILITY) "WITH DBL 4' IX FOR APPLICABILITY) CONTINUOUS 4" CONCRETE PAVEMENT MONOLITHIC CONC. FOOTING (2500 PSI MIN.) .REINFORCED WITH2 #5's CONTINUOUS ONCR TE BASE RAIL ANCHO 1,A .CONCRETE BASE RAIL ANCHORAGE � B C C - SE RA ANCHORAGE BASE RAIL ANCHORAGE Not 7o.Scale E (OPTIONAL -OPEN CARPORTS ONLY) 1 (; BA 1 p Not To Scale . . Not To Scale RAIL O Not To.Scale DRILL 518 HOLE THROUGH THE 2" WASHERS 24" 16 GA;U-CHANNEL BRACE(5' TO T POST) BASE RAIL AND SECURE TO. 487.16 GA U-CHANNEL BRACE (8'.TO 14' POST) .. ANCHOR EYE WITH 1/2".DIAMETER BRACE'ANGLE SHALL BE MIN. 45° TS CONTINUOUS TS. BOW RAFTER 6 LONG TS NIPPLE . SECURE POST 70 NIPPLE THROUGH -BOLT BASE RAIL TO MAX. 60°'FROM HORIZONTAL NO SCREWS' WITH (4) #12-14 z 3/4" SDF's REQUIRED NIPPLE TO 3/16• B IN BOW END 5" . - - RAFTER - 4" 16 GA 11-CHANNEL BRACE (5' TO T POST) .. T FROM r� TS RAFTER" 48.16 GA U CHANNEL' BRACE (8' TO 14" POS TS RAFTER POST ... 9 I/2" BRACE ANGLE SHALL BE MIN. 45 O MAX. 60° OM HORIZONTAL NIPPLE TO 3116 BASE RAIL . (SEE GROUND ANCHOR g" i TS CONTINUOUS BASE SCHEDULE. SHEET,1 OF 6, 6. MINIMUM 4 6" LONG TS NIPPLE o i FOR REQUIRED ANCHOR) +. - SECURE POST TO NIPPLE WITH ( 314 j ii 3". 4) #12 14 x . " SDPs 6' LONG TS NIPPLE SECIjRE, FTER CONTINUOUS 4"_ ,i.-NIPPLE WIITTH.(4)#12-D x3/470 CONCRETE PAVEMENT R p POST SELF -DRILLING' FASTENERS .TS RAFTS OST .. TS RAFTER POST/BASE EYE.ANCIIOR BOX EAVE RAFTER/POST DETAIL BOW RAFTER/POST DETAIL 3 2/ti ZB Not To Scale 1E= CONCRETE. BA�WHE E. RAIL ANCHORAGE Not To scale NotToScale Not To Scale (OPEN CARPORRESLAB EDGE DISTANCE DOES NOT - - MEETMINIMUM EDGE DISTANCE SHOWN IN DETAIL 18) _ .. .. .. . TS.POST TS T \\IIIIII//. 2" x 2' x 2" 16 GA ANGLE CLIP . SECURE TO POST AND TOP OF RAIL/GIRT WITH 4 #1A2-114 x 3/4"" SDF RAFTER TS TRUSSED RAFTER"CHORD,'. c) . OAS R (2) ON,TOP OR.BOTTOM, (2) ON SIDE OR NON-STRUCTURAL HEADER Ts END POST OR DOOR/ 0b WEST YdRkAVENU14 Q T1NG� INC. TO' 11 I C. WINDOW FRAME POST. 2"x2"x2" 16 GA ANGLE. CLIP DELANB; F IdA 32720N �\ SECURE TO POST (EACH. SIDE) 1=1/2' x 1-112" x 2" 16 GA CLIP TS NON-STRUCTURAL HEADER — 38 TS BASEIWINDOW RAIL OR AND RAFTER CHORDIRAIL WITH _ ANGLE SECURE TO _ 0 NON-STRUCTURAL HEADER (4) #12-14 x 3/4" SDF's, (2) ON POST AND BASE RAIL r = (12 GA IF ROLL -UP DOOR FRAME) TOP OR BOTTOM, (2) ON SIDE WITH (4) #12-14 x 3/4" SDF'§, (2) ON TOP, (2) ON SIDE - NOTE: AT ROLL -UP DOOR Thoma oI;P•E, Florida 8 TF OPENINGS, POST SHOULD TS WINDOW RAIL OR GIRT OP BE FLUSH WITH RAIL END. i I CLIP POST TO RAIL ONLY ON FOR VERTICAL SIDING OPTION �_ I DA SIDE OPPOSITE THE OPENING. // TSCONTINUOUS BASERAIL NON-STRUCTURAL HEADER, WINDOW CA 0 _ `CARPORTS, INC. POST TO RAIL, TRUSS CHORD, OR END POST/BASE RAIL CONN, RAIL, OR GIRT TO POST CONN. DETAIL GENERIC PLANS FOR USE 1N THE STATE OF FLORIDA NON STRUCTURAL HEADER CONN.-DETAIL 5 s Not To Scale Not To Scale 09/05/2O21I 4 Not To Scale BECHTOL ENG/NEER/NG ,,kb NTS AND W877MG, I- tb `"°"a G21001 . .. .. CONd147RA eEQ1EOR1TA4 BIVR01�BIfAI,AM WIFAW27ESfBq BIOl�tB anaomm�m ""n°' m` TB' .. SHEET 4 OF 6. NIPPLE TO 3/16" DBL. HDR: ' TS RAFTER POST 6' LONG TS NIPPLE SECURE EACH WITH (4)#12-14 z 3/4"'. SELF -DRILLING FASTENERS .• 2'x2"x2' 16 GA ANGLE CLIP 6• LONG TS NIPPLE SECURE EACH WITH 'LONG TS NIPPLE 12 GA TS POST SECURE TO POST AND (4) #12-14 x 3/4' 118• SECURE WITH (4) #12-14 x 314' SELF -DRILLING FASTENERS RAFTER WITH (4) #12-14 z 3/4' SELF -DRILLING FASTENERS �� SDF's, (2) ON BOTTOM_ , o (2) ON SIDE . r r7 OR. TS BASE RAIL - 2'x4" 16 GA PLATE SECURE TO EACH SIDE OF i o i o 2 GA DOUBLETS HEADER TS END POST POST/RAFTER CONNECTION �� L J WITH (4) #12-14 x 3/4" SDFS, 2 GA TS POST 3/16" NIPPLE TO (2) ON POST, (2) ON RAFTER DBL. HDR. 3/16'. NIPPLETO BASE RAIL RAFTER POST/BASE END POST/RAFTER: CONN. DETA, IL -RAFTER POST/DBL. HEADER DE TAIL RAFTER POST/HEADER DETAIL BASE -RAIL CONNECTION DETAIL - 7 8. Not To Scale Not To Scale Not To Scale Not To Scale 1-1/2" x 1-1/2' x 2" 16 GA CLIP ANGLE SECURE TO RAFTER'POST AND . TS RAFTER POST GABLE RAIL WITH (4) #12-14 x 3/4" SDFs, NIPPLE TO 3)16"• 6" LONGTSNIPPLE TOP AND BOTTOM RAFTER SECURE WITH (4)'#12-14 x.3/4" SDFS 2'x4' 16 GA PLATE (ONE REQUIRED) SECURE TO EITHER SIDE OF �1-1/2"'x TS RAFTER 12• LONG TS, NIPPLE. SECURE POST TO NIPPLE POST/RAFTER' CONNECTION WITH (4) #12-14 x 3/4' SDFs, 1-1/2" x 2" 16 GA CLIP WITH (4) 012-14 x 3/4" SDPs, (2) ON POST,.(2) ON RAFTER . ANGLE SECURE TO RAFTER • AND. GABLE RAIL WITH 4 1-172' z 1-1/2" x 2' 16 GA CLIP ANGLE • TS LEAN-TO RAFTER • _. #12-14 x 314" SDF's, (2) ON TOP, SECURE "f0 RAFTER AND ,GABLE . .,_-� ,-_" • • • 2 ON BOTTOM 1-1/2' x 1-1/2" x 2" 16 GA O RAIL WITH (4) #12-14 x 3/4" SDF's, (2) ON TOP, (2) ON BOTTOM ° CLIP ANGLE SECURE TO RAFTER POST AND GABLE ' RAIL WITH (4) #12-14 x 3/4" SDF's (2) ON TOP, (2) ON SIDE TS GABLE RAIL `o LIP ITO 24. 16 GA U-CHANNEL BRACE (V TO T POST) SECURE P S AND TS RAFTER POST 6° LONG TS NIPPLE 48" 16 GA U-CHANNEL BRACE (8' TO 14' POST) RAFTER WITH (4);'#12-14 x 3)4' SECURE RAFTER AND POST TS GABLE RAIL BRACE ANGLE SHALL BE MIN. 45° SDF's, (2 .ON RAFTER TO NIPPLE WITH (4) #12-14x 3/4" TO MAX. 60° FROM HORIZONTAL TER TS RAF POST P (2) ON. POST SELF -DRILLING FASTENERS' . . GABLE RAIL :TO RAFTER POST TSRAFTER POST CONNECTION DETAIL SIDE EXTENSION POST / LEAN-TO -RAFTER.CONN. DETAIL 11A GABLE RAIL 'TO. RAFTER POST RAFTER/POST DETAIL 13 Not ToSoale CONNECTION DETAIL 1 2 Not To scale Not Tos�a,e 11 B Not To Scale . I' I� 2-1/4" FOR 12 GA FRAMING . 2-1/2" FOR 14 GA FRAMING 16 GAUGE U-CHANNEL BRACE FASTENED TO THE POST AND RAFTER WITH (2) #12-14 x 3/4" SDFS AT EACH END (4 PER BRACE) — BRACE SECTION Not To Scale TS LEG POST TS LEG POST 1-1/2' 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4" SDF TS RAILS TS POSTS SPACED NOT MORE THAN 48" O.C. 4 6 4 4 • 1 26 GA. METAL ROOF 84' PANEL TS BASE RAIL TS RAFTER ROOF PANEL ATTACHMENT (ALTERNATE FOR VERTICAL ROOF PANELS) Not To Scale TYPICAL FLOOD .VENT FRAMING PLAN NOT TO SCALE SEE GENERAL NOTE No. 12, SHEET 1 OF 6.. \��11111111///�i �i VE RT1.:t0AL0 E.0PTI-ON SEE . 7 TABLE 1 OPENING FOR.SWINGING DOOR SHEET WITH NON-STRUCTURAL HEADER 1 OF 6 . �--�. 1-1/2" 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) #12-14 x 3/4° SELF -DRILLING 6' FASTENER SPACED NOT MORE THAN 48, O.C. OPENING FOR SWINGING DOOR WITH NONSTRUCTURAL HEADER 4 4 GIRTS g 4 LE bIRTS (TYpical) : a 4 6.0.9 (Typibal) _ a 12' MAX: OPENING FOR ROLL -UP DOOR WITH 6 5 4. NONSTRUCTURALHEADER a AAA' ' -TYPICAL END WALL OPENINGS POST/RAFTER/GIRT FRAMING PLAN. ' NOT TO SCALE TYPICAL SIDE -ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE 6 q SEE . . TABLE 1 SHEET .1 OF 6.. 6 6 3. j E O 7- g 5 17 MAX. OPENING FOR ROLL -UP DOOR WITH STRUCTURALHEADER IG4 4 .q 4 q 4: 5 10- 3 3 4 ' -- ] 7--7 3. q 5 OPENING FOR WINDOW WITH • NONSTRUCTURAL HEADER. ' LENGTHMARIES DEPENDING ON NUMBER AND WINDOW RAIL AND SPACING OF RAFTERS (Also applicable to End Walls) TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE \\\01 1111111// 'k�P.S . R y �� V