HomeMy WebLinkAboutProduct Approval; Roof DeckgA
aCIS Home ( Log In User Registration Hot Topics Submit Surcharge Stats & Facts ( Publications Contact. Us eCls site tdap links ( Search
PrSoduct Approval
UER: Public User
�rod� n gval Menu > Product or Appl tfo� earch > ApnllcaUon Ltst > Application Detail
FL #
FL6596-R6
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Carolina Carports,Inc.
Address/Phone/Email 187 Cardinal Ridge Trail
Dobson, NC 27017
(336)36-7-6400
FLva lid atio n@yahoo.com
Authorized Signature Tim Gammons
tim.ga@carolinacarports.com
Technical Representative Jason .Cope
Address/Phone/Email 187 Cardinal Ridge Trail
Dobson, NC 27017
(800)670-4262 Ext2037
jason.c@ccihq.biz
Quality Assurance Representative
Address/Phone/Email
Category Structural Components
Subcategory Roof Deck
Compliance Method Evaluation Report from a Florida Registered Architect'or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Johnathan E. Green, RE.
Evaluation Report
Florida License PE-88223
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/05/2027
Validated By Brian Jaks, RE.
E-1 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL6596 R6 COI Letter of Certification- Carolina Carports 2020 sealed.pdf
Standard Year
ASTM E 1592 2005
FM 4471 1992
Product Approval Method Method 1 Option D
Date Submitted 09/14/2020
Date Validated 10/06/2020
Date Pending FBC Approval 10/1912020
Date Approved 12/15/2020
Summary of Products
FL # _
Model, Number or Name
Description
6596.1
AG Panel
26 Ga AG Roof Panel over open framing
Limits of Use
Installation Instructions.
Approved for use in HVHZ: No
FL6596 _RCS II FL6596.1 26 Ga. AG Roof Panel sealed.pdf
Verified By: ]ohnathan E Green, P.E. 88223
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +57.3 psf/=62.5 psf
Evaluation Reports
Other: See Evaluation Report for various design pressures.
FL6596 R6 AE FL6596.1 26 Ga. AG Roof Panel sealed pdf
Created by Independent Third Party: Yes
Install per manufacturer's details. Not for use in HVHZ Zones.
6596.2 ��Gl
29 Ga. AG Roof Panel over open framing
Limits of Use
Installation Instructions
Approved: for use in HVHZ: No
F1.6596 R6 II F1.6596.2 29 Ga. AG Structural Roof Panel NON
HVHZ seated. d�
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: ]ohnathan E Green, P.E. 88223
Design Pressure: +43.6 psf/-57.3 psf
Created by Independent Third Party: Yes
Other: See Evaluation Report for various design pressures.
Evaluation Reports
Install per manufacturer's details. Not for use in HVHZ Zones.
FL6596 R6 AE FL6596.2 29 Ga. AG Structural Roof Panel
NON HVHZ sealed pdf
Created by Independent Third Party: Yes
Bach faext
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 phone: 850-487-1824
The State of Florida Is an AA/EEO employer. CoiijLght 2007-2013 State of Florida Privacy Statement :: Accessibility Statement :,. Refund Statement
Under Florida lacy, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail, if'you -have any questions; please contact 850.487.1395. *Pursuant to Section'455.275(l ),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalit
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the.Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter455, F.S., please click b2re .
Product Approval Accepts -
OF M
O cCktci
Credit
Safe
1.
Force E, ngineering & Testing
19530 R.-imblewood Drive
I lumble,1'ens 77.138
Plane: (281) 549-6601 FAX: (281),540-9966
Product Evaluation Report
CAROLINA CARPORTS, INC.
Florida Product Approval # 6596.1 R6
Florida Building Code 2020
Per Rule 61G20-3
Method: 1—D
Category: Structural Components
Subcategory: Roof Deck
Compliance Method: 61G20-3.005(l)(d)
NON HVHZ
Product Manufacturer:
Carolina Carports, Inc.
187 Cardinal Ridge Trail
Dobson, NC 27017
Engineer Evaluator:
Johnathan Green, P.E. #88223
Florida Evaluation ANE ID: 12901
Valldator:
Brian Jaks P.E. #70159
Contents:
Evaluation Report Pages 1- 4
WD em
p ;cam
N
SEP 112020 AL
111111 111%�i\
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY JOHNATHAN
GREEN ON THE DATE
ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE
SIGNATURE MUST BE
VERIFIED ON ANY
ELECTRONIC COPIES.
FL# 6596.1 R6
Y�r
r
o rce En inet�r ing �c Testing
19530 Ramblmoal Drire
1III nlble,'i erns 77338
Phone: (281) 34ih6603 hAX: (28l) S40.99636
tVebsitc: �P51tii,farcccliginccrlligtesting.cam
Compliance. Statement. The product as described in this report has demonstrated compliance with the
Florida Building Code 2020, Sections 1504.3.2,1504.7,
Product Description: AG Roof Panel, 26 Ga. Steel, 36" Wide, through fastened structural roof panel.
Structural Application.
Panel Material/Standards: Material: 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida
Building Code 2020 Section 1507.4.3. Optional paint finish.
Yield Strength: Min. 80.0 ksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2020, Section 1507.4.3.
Panel Dimension(s): Thickness: 0.0185" min. order thickness
Width: 36" maximum coverage
Rib Height: %" major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener: #12-14 x %" HWH SD#3 with 5/8" (16mm) diameter sealing washing or approved
equal.
Corrosion Resistance: Per Florida Building Code 2020, Section 1507.4.4.
Substrate Description: Minimum 14 Ga. (Grade 50) Steel tube framing or Minimum 18 Ga. (Grade 50)
Steel hat channel purlins/girts. See Table A for steel gauge. Framing must be
designed in accordance w/ Florida Building Code 2020.
Allowable Design Pressures:
Table "A"
Maximum Design Pressure:
-59.9 psf
-52.5 psf
-83.3 psf
+46.9 psf
+57.3 psf
Panel Fastener Pattern:
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
Panel Span:
5,4, O.C.
4'-0" O.C.
4'-0" O.C.
514" O.C.
4'-0" O.C.
Substrate:
Min.14 Ga.
Steel Framing
Min.18 Ga. Steel
Framing
Min.14 Ga. Steel
Framing
Min.18 Ga.
Steel Framing
Min.18 Ga.
Steel Framing
*Design Pressure includes a Safety Factor 2.0.
a �
H 6
B `'m
ea
IvAL
SEP 112020 6/1lljlil����
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY JOHNATHAN
GREEN ON THE DATE
ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE
SIGNATURE MUST BE
VERIFIED ON ANY
ELECTRONIC COPIES.
FL# 6596.1 R6
Force Engineering & Testing
19530 Runiblewoocl Prive
l lutnble, Textis 77338
P urne: (281) 540.6601 .laAX: (281) 540-9960
Weusile: tsww.forcec»gi�recHnglestinl.zam
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2020, Sections 1504.3.2, 1504.7.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2020, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
o ASTM E 1592-05 (2012) Test method for structural performance. of
sheet metal roof and siding systems by uniform static air pressure
difference
® FM 4471-92 - Foot Traffic Resistance Test
Reference Data: 1. ASTM E 1592-05 Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No.183-0063T-16A-E
2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No.183-0109T42, & 183-0142T-15
3. Certificate of Independence
By Johnathan Green, P.E. (No. 88223) @ Force Engineering & Testing
(FBC Organization # ANE ID:12901)
Test Standard Equivalency: The ASTM E 1592-05 test standard is equivalent to the ASTM E 1592-05 (2012)
test standard.
The FM 4471-10, Foot Traffic Resistance test standard is equivalent to .
FM 4471-92.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2020, including Section
1S07.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per manufacturer's recommended details.
SEP 112020 ZZ
�l1t�91��gp�
,qp h
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY JOHNATHAN
GREEN ON THE DATE
ADJACENT TO THE SEAL,
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE
SIGNATURE MUST BE
VERIFIED ON ANY
ELECTRONIC COPIES.
FU 6596.11116
Force Engineering & I esting �
19530 Rumbleuvoad Drive
11umble,'1'exas 773&14
Ptinne. (231) 5#0.6603 FAX. (231) 540.9960
ii'elrsit C: 1p'14'iti.rureC Cfl�tSiCCYIIIgtlesll n�.CUm
Insulation:
Manufacturer's approved product (Optional)
Roof Panel Fire Classification:
Fire classification is not part of this acceptance,
Shear Diaphragm:
Shear diaphragm values are outside the scope of this report.
Design Procedure:
Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2020 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2020
Chapter 22 for steel, and'Chapter 16 for structural loading.
4
i l
sue, l�qp ;pra
�Z.,
6� �p
SEP 112020 /��p�j/WAL
111
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BYJOHNATHAN
GREEN ON THE DATE
ADJACENT TO THE SEAL,
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE
SIGNATURE MUST BE
VERIFIED ON ANY
ELECTRONIC COPIES.
FL# 6596.1 R6
Farce Engineering & Testing
19330 IlomblLwood Drive
IHunibte, "! exos 77338
Phone: (281) 540•tr6 1 rAX: (231) 540.9966
Websitc: ivw%v.i'orceertt inceringtesting.com
MI. 1B CA. (CRAPE 50) STEEL HAT CHANNEL FNWIG
OR W. 14 Ok (GRADE 50) STEEL TUBE'00AWHG
(SEE TABLE A FOR SPAM)
x 3/4' NOH SDg3 W/ 5/6' (16mm) O'A4ETER SWIG WASHER
Qe .ob"oa4
lb
:-o N
SEP 112020 ��®AL
11,1111110�'���
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BYJOHNATHAN
(GREEN ON THE DATE
ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE
SIGNATURE MUST BE
VERIFIED ON ANY
ELECTRONIC COPIES.
FL# 6596.1 RG