HomeMy WebLinkAboutReport of Moisture Density Relationshipd7
THOMAS
CQ)EC)TECHNICAL SERVICES
REPORT OF MOISTURE DENSITY RELATIONSHIP
Tested for: Elder Mendoza Propertys, Inc. Project: Proposed New Residence
2225 SE Short Street 17650 Orange Avenue
Port St. Lucie, Florida 34952 Fort Pierce, Florida 34983
Attn: Mr. Elder Mendoza Inspector: Roberto Martinez
Title: Contractor
cc: TGS Project #: 21-287 -1
Date: 08/11 /21
®�������o��������mmww
WMIMI �����
MM==
IWIMMM ����������I•MwMv�"MMMMMMEMMMUMMM���������
mmmmmmm�=MmM����e�����
M=ls=MMMMMM=MMMMMMMMM
SOIL DESCRIPTION
Visual Classification: Light Brown Silty Sand w/ shells
Sample Source: Building Pad
Method of Test: T-180
Test Results:
Maxium Dry Density = 114 pcf Optimum Moisture = 12 %
R` spectfully Submitted
r$
F ncois o a , P.E.
Pi nFipal Engineer
FI rids Registration No. 56381
RECEIVED
AUG 13 2021
St. Lucie County
Permitting
THOMAS GEOTECHNICAL SERVICES, LLC
6594 WOODLAKE ROAD, JUPITER, FL 33458
PHONE: 561-725-2602
STATE OF FLORIDA PROFFESIONAL ENGINEERS LICENSE # 34141