Loading...
HomeMy WebLinkAboutPROPOSED SUNROON WALLSDESIGN CRITERIA: APPLICABLE CODES, REGULATIONS & STANDARDS 1'. THE 2020 FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM & CH. 23 WOOD. 2. AA ASM 35 & SPECIFICATIONS FOR ALUMINUM STRUCTURES, PART 1-A OF THE ALUMINUM DESIGN MANUAL PREPARED BY THE ALUMINUM ASSOCIATION, INC. WASHINGTON D.C. 2005 ED. 3. ASCE 7-16 & SE17 4. NDS NATIONAL DESIGN SPECIFICATION FOR WOOD. 5. ACI318 CONCRETE REFERENCE MANUAL. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 1604.5 & TABLE 1604.5: RISK CATEGORY 2. 2. BASIC WIND SPEED, TABLE 1609C, STATE OF FLORIDA DEBRIS REGION & BASIC WIND SPEED, PARAGRAPH 1609.3.1 & TABLE 1609.3.1 EQUIVALENT BASIC WIND SPEED: 160 MPH EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: B 3. WIND LOADS PER FBC TABLE 2002.4 (MWFRS) VULT = 160 MPH & EXPOSURE = B FOR 20 X 20 X 0.013" MESH SCREEN HORIZONTAL PRESSURES ON WINDWARD SURFACES = 36 PSF HORIZONTAL PRESSURES ON LEEWARD SURFACES = 25 PSF VERTICAL PRESSURES ON SCREEN SURFACES = 10 PSF VERTICAL PRESSURES ON SOLID SURFACES = 29 PSF FOR 18 X 14 X 0.013" MESH SCREEN, APPLIED FACTOR = •88 FOR ALLOWABLE STRESS DESIGN, APPLIED FACTOR = •6 FOUNDATION DESIGN FOOTING SIZE EXISTING CONCRETE SLAB. NO ADDITIONAL FOOTING OR FOUNDATION SYSTEM IS REQUIRED BY THE PROPOSED CONSTRUCTION IF A MINIMUM 4" CONCRETE SLAB IS PROVIDED IN SOUND CONDITION, FREE FROM STRUCTURAL CRACKING, SPALLING & OTHER DETERIORATION. EXISTING FOUNDATION/FOOTING UNDER CONCRETE SLAB MINIMUM 8'k8" W/ (1) #5 BAR TO BE VERIFIED BY CONTRACTOR. SEE TYPICAL FOOTING DETAILS FOR NEW FOOTING DESIGN MINIMUM REQUIREMENTS. MISCELLANEOUS 1. SCREENED ENCLOSURES CONTAINING SWIMMING POOLS SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF FBC R4501.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS. 2. ALUMINUM ADDITIONS ARE NOT TO BE INSTALLED ON A MANUFACTURED HOME, TRAILER HOME, OR PRE-FAB HOME. IF THE EXISTING STRUCTURE IS ONE OF THESE, A SEPARATE 4TH WALL SUPPORT SYSTEM IS SO TO BE ENGINEERED SO THAT NO ADDITIONAL LOADING IS PLACED ON THE MANUFACTURED HOME. FASTENER SPECIFICATIONS 1. FASTENERS ARE REQUIRED TO BE SAE GRADE 2 OR BETTER ZINC PLATED. (CONCRETE ANCHORS ARE TO BE TAPCONS OR BETTER, INSTALLED TO MFG. SPECIFICATIONS) 2. IT IS THE OWNERS RESPONSIBILITY TO MAINTAIN THE SCREENS, FASTENERS AND SCREENS TO MANUFACTURING SPECIFICATIONS. 3. WHERE WOOD DECK IS PRESENT USE 1 /4" X 3-1/2" GALV. LAG SCREWS IN LIEU OF MASONRY ANCHORS. UNLESS OTHERWISE SPECIFIED. 4. 1 "X2" NON STRUCTURAL MEMBERS ATTACHED TO HOST A. FOR MASONRY/CONCRETE APPLICATION USE GALVANIZED 1 /4" X2-3/4" TAPCONS OR EQUAL AT24" O.C. AND 6" FROM ENDS B. FOR WOOD APPLICATION USE #14 X 2-3/4" WOOD SCREW AT 24" O.C. AND 6" FROM ENDS. C. FOR ALUMINUM APPLICATION USE # 10 X 1-1 /2" SMS OR TEK SCREW AT 24" O.C. AND 6" FROM ENDS D. WHERE 1 "X2" INSTALLED THROUGHOUT AN "OPEN VIEW" SPACING SHALL BE REDUCED TO 18" O.C. AND 6" FROM ENDS RESPONSIBILITIES 1. ALL SITE WORK SHALL BE PERFORMED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH APPLICABLE BUILDING CODES, LOCAL ORDANANCES, AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES. 2. FOR FASTENERS WHICH ARE NOT VISIBLE AFTER INSTALLATION, THE CONTRACTOR SHALL VERIFY AND ENSURE INSTALLATION HAS BEEN ACCOMPLISHED IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND IN ACCORDANCE WITH THE ATTACHED DETAILS. 3. FOR "PICTURE WINDOW" MODIFICATION TO EXISTING SCREEN ENCLOSURES, ALL OTHER "EXISTING SCREEN ENCLOSURE" FEATURES ARE TO MEET THE TYPICAL DETAILS AS PROVIDED IN THESE DETAILS. CONTRACTOR IS TO VERIFY & ASSURE EXISTING SCREEN ENCLOSURE IS STRUCTURALLY SOUND. 4. CONTRACTOR TO PROVIDE NOA'S & INSTALL ALL MATERIALS AS PER MANUFACTURER'S SPECIFICATIONS. 5. INTEGRITY OF EXISTING/ HOST STRUCTURE SHALL NOT BE COMPROMISED WITH THE ATTACHMENT OF THE PROPOSED STRUCTURE. SHEET NO. DRAWING INDEX S/01 GENERAL NOTES S/02 PLAN/ ELEVATIONS S/03 DETAILS PROPOSED TYPE III SUNROOM WALLS UNDER EXISTING COVERED LANAI SEE FOUNDATION DESIGN SHEET-01 ALUMINUM MEMBERS DIMENSIONS HOLLOW SECTIONS 2 x 2: 2x2"x0.044" 2 x 3: 2'S6NO.050" 2 x 4: 2'k4'k0.050" 2 x 5: 2x5"x0.050" OPEN BACK SECTIONS 1 x 2: 1'kKnO.044" 1 x 3: 1 "x3'k0.045" SNAP SECTIONS 2 x 2 SNAP: 2x2'k0.045" 2 x 3 SNAP: 2"x3x0.050" 2 x 4 SNAP: 2x4"x0.045" SELF MATING (SMB) 2 x 4 SMB: 2"x4"x0.044'k0.100" 2 x 5 SMB: 2'k5"x0.050'k0.109' 2 x 6 SMB: n6lx0.050'k0.120" 2 x 7 SMB: n7'k0.057'k0.129' 2 x 8 SMB: 2"x8"x0.072N0.124" 2 x 9 SMB: 2x9"x0.082"x0.124" 2 x 10 SMB: 2"x10"x0.092"x0.398" DETAIL A .d ci N LL LLl =Z'co o ==;W o O O Q= °- o 00 0-4 = co O a� Z. _ z � � r c�%' ''-,, �,� •• .......RAF w .. GOB co THESE PLANS WERE PREPARED BASED ON THE PREMISE THAT THE EXISTING STRUCTURE WAS DESIGNED BY A PROPERLY LICENSED PROFESSIONAL ENGINEER OF THE STATE OF FLORIDA, WAS PERMITTED BY THE APPROPRIATE PERMITTING AGENCY, WAS CONSTRUCTED BY A FLORIDA LICENSED CONTRACTOR AT THE TIME OF CONSTRUCTION, HAS NOT BEEN SUBJECT TO DAMAGE BY A MAJOR EVENT, AND HAS BEEN CERTIFIED BY THE CONTRACTOR THAT THE EXISTING STRUCTURE CURRENTLY SHOWS NO DEVIATIONS OR DEFECTS FROM THE STATE OF THE STRUCTURE AS PERMITTED BY THE FINAL INSPECTION OF THE PERMITTING AGENCY. ALSO, THE OWNER AND ALL PARTIES CONCERNED WILL INDEMNIFY FLORIDA ENGINEERING LLC FROM ANY DAMAGES OR CHANGES TO THE EXISTING STRUCTURE AS A RESULT OF ANY MODIFICATION OR FOR ANY OTHER REASON. CONTRACTOR TO PROVIDE NOA'S & INSTALL ALL MATERIALS AS PER MANUFACTURER'S SPECS. CONTRACTOR TO PROVIDE FLORIDA APPROVED WINDOW WITH PRODUCT APPROVAL OR NOTICE OF ACCEPTANCE (N.O.A.) MUST BE ABLE TO WITHSTAND MINIMUM DESIGN PRESSURES NOTED. // FL APPROVED WINDOW ALUMINUM SPECIFICATIONS 1. ALUMINUM EXTRUSIONS SHALL BE 6005 T5 ALLOY UNLESS OTHERWISE NOTED. 2. ALL SELF MATING BEAM SECTIONS ARE TO BE STITCHED WITH # 12 SCREWS 6" FROM ENDS & 24" CENTER TO CENTER. #'10 SCREW 6' FROM ENDS & 12" CENTER TO CENETER. 3. ROOF BRACING SHALL BE A MINIMUM 2"X2"X.050". 4. THE MINIMUM NORMAL THICKNESS OF PROTECTOR PANELS (KICKPLATES) SHALL BE AN INDUSTRY STANDARD OF 0.024 INCHES. 5. VINYL AND ACRYLIC PANELS SHALL BE REMOVED WHEN WIND SPEEDS EXCEED 75 MPH PER FBC. 6. SCREEN MATERIAL SHALL BE 18/14 SCREEN UNLESS APPROVED BY FLORIDA ENGINEERING LLC. 7. 1"X2" & 1"X3" NON STRUCTURAL MEMBERS MAY BE USED INTERCHANGEABLY. 8. DOOR LOCATION MAY BE RELOCATED BY CONTRACTOR IN THE FIELD. COMPONENTS AND CLADDING PRESSURE FBC 2020 CH. 16 SECTION 1609.1 FLORIDA PRODUCT APPROVAL TABLE DESIGN PRESSURES NOA#APPROVED DP PRODUCT MANUFACTURER NOA#/FL# +PSF/-PSF +PSF/-PSF 9200 SERIES DOOR 1 LAWSON INDUSTRIES INC. 15441.4 +26.83 / -29.17 +70 PSF / -70 PSF 8700 SERIES GLASS 1 LAWSON INDUSTRIES INC. 15428.3 +27.41 / -36.58 +65 PSF / -65 PSF . 8700 SERIES GLASS 2 LAWSON INDUSTRIES INC. 15428.3 +27.45 / -36.64 +65 PSF / -65 PSF 8700 SERIES GLASS 3 LAWSON INDUSTRIES INC. 15428.3 +27.45 / -29.79 +65 PSF / -65 PSF 8710 SERIES GLASS 4 LAWSON INDUSTRIES INC. 1 15428.3 +33.24 / -44.33 +65 PSF / -65 PSF EX. CONCRETE COLUMN 2X3 x \ON 2X3 ua a� mz Qr \ON x 2X3 EX. CONCRETE COLUMN I- 7'-011 -i NOTE: 1. NOT AN APPROVED IMPACT PROTECTION SYSTEM. SHUTTERS ARE REQUIRED ON HOST STRUCTURE REGARDLESS OF WINDOW RATING. SITE -SPECIFIC ENGINEERING IS REQUIRED TO DESIGN FOR IMPACT PROTECTION 2. THERE ARE EXISTING HURRICANE SHUTTERS FOR ALL OPENINGS UPON RESIDENCE. RESIDENCE J� EX. CONCRETE ` COLUMN NEW TYPE III SUNROOM UNDER rl EXISTING HOUSE PATIO ROOF X. CONCRETE X. CONCRETE COLUMN COLUMN I I 19'-8 3"$ EXISTING APPROVED BEAM 23 21OX3 5 SLIDING GLASS- o m \ x x x \ m x r'4 DOOR (.I Ln cv tu a \ m z 2X3 2X3 z u co\ x M x M INS. PANEL u >X y O I O (#7561.1-R5) 3" RC 81-611 -i - 9'-2 g -i N_ .. .d m Y N .4 N o O LLI O0 a N CD 0 y•'> z 4(�� •. �i ui WINDOW INSUL ALUM. FRAME PANEL FL # 12225-R4 # 12 @ 8" C.C. EA. SIDE OF C-CHANNEL 3"FROM EGDE OF SLAB/ FTG. 1 /4" X 2 1 /4" TAPCON ANCHOR @ I W O.C. TO CONC. OR 1 /4" X 3" LAG TO WOOD TYP. SUNROOM WALL CONNECTION SCALE: N.T.S. EXST. WOOD BEAM (4)-# 14 TEK SCREWS EA. SIDE FACE OF BEAMP ALUM COL OR BEAM BEAM / COL TO WOOD (TO WOOD WALL OR TIE BEAMS) ALUM COL OR BEAM (4)-# 14 TEK SCREWS EA. SIDE FACE OF BEAM/ EXST. CONC OR MASONRY BEAM / COL TO CONC. (TO CONC. FOUNDATION CONC. TIE BEAM OR CONC. WALL) 2'XZX1 /8" X 2" LG. ANGLE TWO SIDES W/ (1)-3/8" X 6" LG. LAGS TO WOOD 2X2X1 X' X 3" LG. ANGLE TWO SIDES W/ (2)-1 hC X 2 1 /4" LG. TAPCON TO CONC OR MASONRY 4NC.HOR WINDOW FRAME TO ::HANNEL & PLATE PER 'RODUCTAPPROVAL :ONT. 1 /8" x 2' ADF. ALUM. PLATE INSUL. ALUM. WALL ALT. SILL ANCHORING EXST. WOOD BEAM ALUM.1 HEADER HEADER/SILL ANCHORING ALUMN, COL. OR BEAM :NT 1 /4'X4" LG. TAPCON @ I2' C.C. TO CONC. OR MASONRY -OR- 1/4'X4" LG. LAG @ 12' C.C. TO WOOD /CD,N GO" LL 6- • o Ui ' o0 O O_ _ CL .c,4 O Z zCD '-, w ////IIIIIIII „ '`\\\\ U 0 *# I O SMS # 14 TEK SCREW 016 O.C. @l6"C.C. CHANNEL TO COLUMN (2)-3/8'X3" LG. LAGS 3"INSUL 3" INSUL (2" COL) USE 1 3/4" X PANEL WALL PANEL WALL (4)-# 14TEK SCREWS (4) 2'X 1/8" U-BRACKET (3" COL) USE 2 31N' X SIDE BRACKET 2" X 1 /8" U-BRACKEf - (4" COL) USE 3 3/4" X ' 2' X 1 /8" U-BRACKET •#10 SMS 2X3'X.064" *#IoS S ALUM COL OR BEAM C-CHANNEL @16PANEL TO ALUMN. DETAIL * = MAY INSTALL #10 SMS @ 8" C.C. OUTSIDE ONLY ALT. BEAM / COL TO WOOD (TO WOOD WALL OR TIE BEAMS) 2' MAX SHIM BY BUILDER 3 � w 2X3X.064" ' - #10TEKSCREW @16C.C.EASIDE zz Md _ C-CHANNEL 1 /4 " X 4 2' LONG ALUM. COL. _ 'TAPCONS @ 12" O.C. 6" MAX. FROM ENDS EXST. CONC. OR MESONRY COLUMN TO CONC. WALL DETAIL 1/4" X 2 1/4' TAPCONS� �CONC. SLAB OR CAP COVER HOLE @ -16" 0/C T.O. MASONRY WALL PANEL TO CONC. DETAIL (�j_ * = MAY INSTALL # 10 SMS @ 8" C.C. OUTSIDE ONL*\\; /