Loading...
HomeMy WebLinkAboutCompaction Test Headquarters � C IL t ENGINEERING Mailing 11345 U.S. Highway 1 ��lei AND TESTING PO Box 78-1377 Sebastian, FL. 32958 Sebastian, FL. 32978 Orlando 2cD 5-0 ` �� Phone: 77C.A.*5693 723 Progress Way � C.A.#5693 Sanford, FL. 32771 KSMengineering.net SOIL COMPACTION REPORT I ASTM D 1557 and ASTM D 6938 I DATE TESTED: August 25, 2021 KSM JOB#: 216759-1d BS '/ am PERMIT M RECEIVED NUC# 528 Nuc Model: MC-IDR-P CONTRACTOR: Manuel Garcia, SEP 13 2021 Nuc Serial#: MD049528 JOB LOCATION: 1718 Linwood Avenue St.Lucie County Fort Pierce, Florida Permitting ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT -' ~ -- -- --OF-SAMPLE _ , _ DEPTH READ -DENSITY' PROCTOR VALUE-(P:C.F)- - COYVIPAGTIOIV - 1 S.W. 0" - 12" 50 108.1 110.9 97.5% 2 N.W. tt tt 109.2 98.5 3 Center " 107.9 97.3% 4 N.E. " 108.5 11 97.8 5 S.E. 108.7 if 98.0% Soil Description: 112.0 I I I I I I I Brown Sand VU E 111.0 In Place Moisture: I I I I I I I 9.4% G 110.0 -..J..-.I—..1..— —..L.. —.1-.._ H Proctor Optimum Moisture: 12.0% T �09.0 -..�..-.1-...t. j.-..�..�.. j-.._ Proctor Max. Dry Density: P.C.F. P Y 110.9 108.0 •I—..;..-.i- T..-I.-..� ..�..-.)-.._ c @Test Locations the Density& 107.0 I I I I I I I �- -•r-••T••—t•-••�••-••-• -..- Penetrometer readings indicate the F I I I I I I Degree of Compaction Meets 106.0 - --I••-•I-••-I-'.-I•-••I-••--I••-•J-••- Minimum Requirement `��` �E KE<<� I I I I I I I I - ---ioi UnstakedFoundation`�`-� �0�� 105.0 -- Respectfully Submitted: Z 7 8 9 10 11 12 13 14 15 ' No. 68366 =_ Diq?W ly sigmeCr = Moisture-%of Dry Weight This item has been electronically signed and 00 to r Disclaimer: Contractor is responsible to maintain the tested area sealed by Julie Keller,P.E.Fl.Lic.68366 on / r the date stated directly to the right using a �I{/ �7 M 1 C of digital signature. / A ��oIR�D in the condition that KSM completed the indicated passed Printed copies of this document are not S NCO compaction test. KSM is not responsible if the tested area has considered signed and sealed and the ,,�{.( S signature must be verified on anyelectronic 2021 .U$/'�n FAL`X\�` been altered from the approved inspected condition. copies. 10:09:33 -04'00' Julie E. Keller, P.E. President PE#68366 8/26/2021 i Email to: Test report shall not be reproduced,except in full,without the written approval of KSM Engineering&Testing Geotechnical Engineering-Construction Materials Testing -Special Inspections-Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business-WBE