HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 122 Block 5 Waterstone 1820 DGR
Builder Name: ADAMS HOMES
Street: 5350 San Benedetto Place
Permit Office:
7. City, State, Zip: Fort Pierce, FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
r-
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeV120.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 270.00 ft2
c. N/A
F2= ft2
4. Number of Bedrooms 4
d. N/A
R=
5. Is this a worst case? No
11. Ceiling Types (1900.0 sqft.)
ft2
Insulation Area
6. Conditioned floor area above grade (ft2) 1820
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0 1820.00 ft2
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(237.2 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 168.74 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER':16.00
c. U-Factor: Dbl, U=0.33 18.33 ft2
SHGC: SHGC=0.31
Area Weighted Average Overhang Depth: 4.181 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
9. Floor Types (1820.0 sqft.) Insulation Area
a. Electric
Ca 40
p gallons
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ft2
b. Conservation features
EF: 0.940
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.130 Total Proposed Modified Loads: 59.82
PASS
Total Baseline
Loads: 64.94
I hereby certify that the plans a ations covered b
this calculation in
Revie of the plans and'HE
are compli the Florid gy
Code.
specifications covered by this
calculation indicates compliance
-�
with the Florida Energy Code.
AL.
PREPARED BY:
Before construction is completed
r
DATE: n.-i-ng-9021 Wo n Kentnany
this building will be inspected for
O .. '
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
with the Florida E�+
Florida Statutes.
;S .
OWNER/AGEN i
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
3/9/2021 9:16 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPIIT CI IIIAMADV f%UCf1V1 ICr ocoe%er
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Lot 122 Block 5 Waterstone
User
1
ADAMS HOMES
661000
Detached
New (From Plans)
1 Bedrooms: 4
Conditioned Area: 1820
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
122-5
Waterstone
5350 San Benedetto PI
St. Lucie
Fort Pierce ,
FL, 34951
Comment:
CLIMATE
Design
Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes
Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
Area
1820 ftz _---
Tile Wood Carpet
0.42 0 0.58
ROOF
v #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ft' 456 ftz Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1820 ft' 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
80 ftz 0.11
Wood
3/9/2021 9:16 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 IAIDI IT CI IMItAAOV ic+r mr-
s
- ��
v■ ■wr��■�a I t\Gr VIR 1
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
1 SW
Exterior Concrete Block - Int Insul
Main
4.1 59
0
10 0
590.0 ft2
0
0 0.6
0
2 NW
Exterior Concrete Block - Int Insul
Main
4.1 13
0
10 0
130.0 ft2
0
0 0.6
0
3 NE
Exterior Concrete Block - Int Insul
Main
4.1 66
0
10 0
660.0 ft2
0
0 0.6
0
- _ 4 SE
Exterior Concrete Block - Int Insul
Main
4.1 27
0
10 0
270.0 ft2
0 0.6
0
5 -
Garage Frame - Wood
Main
13 27
0
10 0
270.0 ft2
0
0.23 0.01
0
6 NW
Exterior Concrete Block - Int Insul
Main
4.1 7
0
10 0
70.0 ft2
0
0 0.6
0
7 SE
Exterior Concrete Block - Int Insul
Main
4.1 13
0
10 0
130.0 ft2
0 0.6
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
NW Insulated Main
None
.25
3
6 8
20 ft2
2
- Wood Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed
orientation.
/
Wall
Overhang
V # Ornt ID Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation -
Int Shade
Screening
1 SW
1 Vinyl Low-E Double
Yes
0.33 0.23
N
6.9 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
2 SW
1 Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3 NW
6 Vinyl Low-E Double
Yes
0.33 0.31
N
5.0 ft2
9 ft 0 in
0 ft 6 in
None
None
4 NW
2 Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
5 NW
2 Vinyl Low-E Double
Yes
0.33 0.21
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
6 NW
6 Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft2
9 ft 0 in
2 ft 0 in
Drapes/blinds
Exterior 5
7 NE
3 Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8 SE
7 Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
12 ft 0 in
0 ft 6 in
Drapes/blinds
Exterior 5
9 SE
4 Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
10 SE
7 Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
12 ft 0 in
0 ft 3 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
396 ft2 396 ft2
64 ft
8 ft
1
INFILTRATION
s
# Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) - .000444
2123.3 116.49
218.7
.1381
7
3/9/2021 9:16 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2n2n 1AI01 1T 01111A11e a ov
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5 34.6 kBtu/hr
1
sys#1
COOLING SYSTEM
f # System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16 35 kBtu/hr cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
--- Supply----
�/ # Location R-Value Area
--- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler
HVAC #
TOT OUT
QN
RLF
Heat Cool
1 Attic 6 364 ft2
Main
91 ft2 Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling an j Feb Mar
Heating f X] Jan f X] Feb X Mar
Venting [ ] Jan [ jj] Feb X Mar
f
[
A r
APr
A r
Ma rj Jun Jul rj Au rj Se
May JunJXJJul AuSep
Ma Jun Jul Aug Se [X]
Oct
Oct
Oct
Nov
Nov
HXNov
Dec
Dec
H Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2
3
4 5 6 7
8 9
10
11
12
Cooling (WD) AM 78
PM 80
78
80
78
78
78 78 78 78 78 80
80
80
80
78 78 78 78 78 78
78
78
78
Cooling (WEH) AM 78
PM 78
78
78
78
78
78 78 78 78 78 78
78
78
78
78
78 78 78 78 78
78
78
78
Heating (WD) AM 66
PM 68
66
68
66
68
66 66 68 68 68 68
68
68
68
68
68 68 68 68 68
68
66
66
Heating (WEH) AM 66
PM 68
66
68
66
68
66 66 68 68 68 68
68
68
68
68
68 68 68 68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ft2
Oft 0.3
Main
3/9/2021 9:16 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the EnergyPerformance Index, the more efficient the home.
5350 San Benedetto Place, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1850.00 ftZ
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0
270.00 ftZ
c. N/A
R=
ftZ
4. Number of Bedrooms
4
d. N/A
R=
ftZ
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
6. Conditioned floor area (ftZ)
1820
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0
R=19.0
1820.00 ftz
80.00 ftz
7. Windows- Description
Area
c. N/A
R=
ftZ
a. U-Factor: Dbl, U=0.33
168.74 ftZ
12. Ducts, location & insulation level
R ftZ
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 364
b. U-Factor: Dbl, U=0.33
32.38 ftZ
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.33
18.33 ftZ
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.31
d. U-Factor: other (see details)
17.78 ftZ
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
4.181 ft.
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average SHGC:
0.269
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ftZ
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
9. Floor Types
Insulation Area
b. Conservation features
a. Slab -On -Grade Edge Insulation
R=0.0 1820.00 ftZ
None
b. N/A
R= ftZ
Credits (Performance method)
Pstat
c. N/A
R= ftZ
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which. will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
R Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/9/2021 9:16 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC.7th Edition (2020) Compliant Software Page 1 of 1