HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-EDEN
Builder Name: KHOVNANAIN HOMES
Street: 5113 ARMINA PLACE
Permit Office:
City, State, Zip: FT PIERCE, FL,
Permit Number:
Owner: EDEN MODEL LOT 32 @ WATERSTONE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type$1796.7 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1516.70 ft2
b. Frame - Wood, Adjacent
R=11.0 280.00 ft2
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 4
d. NIA
R= ft2
5. Is this a worst case? No
11. Ceiling Types (1618.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1618.00 ft2
6. Conditioned floor area above grade (ft2) 1616
b. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
7. Windows(154.9 sqft.) Description Area
12. Ducts
R ft2
a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH 6 300
a. U-Factor: Dbl, 1_1=0.28 113.92 ft2
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55 41.00 ft2
13. Cooling systems
k$tulhr Efficiency
SHGC: SHGC=0.34
a. Central Unit
29.4 SEER:16.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 4.909 ft.
14. Heating systems
kBtulhr Efficiency
Area Weighted Average SHGC: 0.311
a. Electric Strip Heat
23.0 COP:1.00
8. Skylights Area
c. U-Factor.(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 40 gallons
9. Floor Types (1616.0 sqft.) Insulation Area
EF:0.950
a. Slab -On -Grade Edge Insulation R=0.0 1616.00 ft2
b. Conservation features
b. NIA R= ftZ
None
c. NIA R= ft2
16, Credits
Pstat
Total Proposed Modified Loads: 54.01
Glass/Floor Area: 0.096
PASS
Total Baseline Loads: 55.24
I hereby certify that the plans and
pecifications covered by
Review of the plans and
114E sr I
this calculation are in complianc
itthe Florida E ergy
specifications covered by this,
,� `
Code.
calculation indicates compliance
_� `,j y+
�r '�rf .`'> =_
with the Florida Energy Code.
,,• .
PREPARED BY:
Before construction is completed
u �"
DATE:
this building will be inspected for
d
compliance with Section 553.908
hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
dLD) iAt
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
7/13/2021 9:18 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: KHOV-EDEN Bedrooms: 4
Address Type:
Street Address
Building Type: User Conditioned Area: 1616
Lot #
Owner Name: EDEN MODEL LOT 32 @ W Total Stories 1
Block/Subdivision:
# of Units: 1 Worst Case: No
PlatBook:
Builder Name: KHOVNANAIN HOMES Rotate Angle: 0
Street:
5113 ARMINA PLACE
Permit Office: Cross Ventilation: No
County-
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT PIERCE,
Family Type: Detached
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
J Design Temp
Int Design Temp Heating
Design Daily Temp
v Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1616 14220.8
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BED 3 161 1416.8 No 1
4
1 No
Yes
Yes
2 HALL BATH 77 678 No 0
1 No
Yes
Yes
3 FOYER 172 1514 No 0
1 No
Yes
Yes
4 BED 4 149 1307 No 1
1 No
Yes
Yes
5 LAUNDRY 52 458 No 0
1 No
Yes
Yes
6 BED 2 149 1307 No 1
1 No
Yes
Yes
7 GRT DIN KITCHEN 550 4840 No 0
1 No
Yes
Yes
8 MASTER SUITE 176 1544 No 2
1 No
Yes
Yes
9 MAST WIC 58 506 No 0
1 No
Yes
Yes
10 M BATH 72 634 No 0
1 No
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BED 3 38 ft 0
163 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio HALL BATH 11 ft 0
77 ft2
_---
1 0
0
3 Slab -On -Grade Edge Insulatio FOYER 25 ft 0
172 ft2
----
1 0
0
4 Slab -On -Grade Edge Insulatio BED 4 14 ft 0
148.5 ft2
_---
0 1
0
5 Slab -On -Grade Edge Insulatio LAUNDRY 1 ft 0
52 ft2
____
1 0
0
6 Slab -On -Grade Edge Insulatio BED 2 13.5 ft 0
148.5 ft2
_--_
0 1
0
7Slab-On-Grade Edge Insulatio GRT DIN KITCHE 49 ft 0
550 ft2
_---
0.5 0.5
0
7/13/2021 9:18 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio MASTER SUITE 26.5
ft 0
175.5 ftz
_---
0
1
0
9 Slab -On -Grade Edge Insulatio MAST WIG 11.5 ft 0
57.5 ft2
----
0
1
0
1 0SIab-On-Grad e Edge Insulatio M BATH 1 ft
0
72 ft'
----
1
0
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Composition shingles 1750 ft2
0 ft2 Medium
N
0.9
No 0.9
No 0
22.6
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1616 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) BED 3
30
Blown
163 ft2
0.1
Wood
2
Under Attic (Vented) HALL BATH
30
Blown
77 ft2
0.1
Wood
3
Under Attic (Vented) FOYER
30
Blown
172 ft2
0.1
Wood
4
Under Attic (Vented) BED 4
30
Blown
149 ft2
0.1
Wood
5
Under Attic (Vented) LAUNDRY
30
Blown
52 ft2
0.1
Wood
6
Under Attic (Vented) BED 2
30
Blown
149 ft2
0.1
Wood
7
Under Attic (Vented) GRT DIN KITCHE
30
Blown
550 ft2
0.1
Wood
8
Under Attic (Vented) MASTER SUITE
30
Blown
176 ft2
0.1
Wood
9
Under Attic (Vented) MAST WIC
30
Blown
58 ft2
0.1
Wood
10
Under Attic (Vented) M BATH
30
Blown
72 ft2
0.1
Wood
WALLS
Adjacent Cavity Width
Space -
Height
Sheathing Framing Solar
Below
o
1
NE
Exterior Concrete Block - Int Insul BED 3
4.1 13
1 9
4
122.1 ft2
0
0
0.5
0
2
SE
Exterior Concrete Block - Int Insul BED 3
4.1 10
8 9
4
99.6 ft2
0
0
0.5
0
3
SW
Exterior Concrete Block - Int Insul BED 3
4.1 12
2 10
0
121.7 ftz
0
0
0.5
0
4
SW
Exterior Concrete Block - Int InsLHALL BATH
4.1 9
11 10
0
99.2 ft2
0
0
0.5
0
5
SE
Exterior Concrete Block - Int Insul FOYER
4.1 4
10 9
4
45.1 ft2
0
0
0.5
0
6
SW
Exterior Concrete Block - Int Insul BED 4
4.1 12
7 10
0
125.8 ft2
0
0
0.5
0
7
NE
Exterior Concrete Block - Int Insul BED 2
4.1 13
1 9
4
122.1 fie
0
0
0.5
0
8
SW
Exterior Concrete Block - Int Ins@RT DIN KIT
4.1 22
6 10
0
225.0 ft2
0
0
0.5
0
9
NW
Exterior Concrete Block - Int Ins(ORT DIN KIT
4.1 23
3 9
4
217.0 ft2
0
0
0.5
0
10
NE
Exterior Concrete Block - Int InsMASTER SUI
4.1 12
7 9
4
117.4 ft2
0
0
0.5
0
11
NW
Exterior Concrete Block - Int IRSMASTER SUI
4.1 12
7 9
4
117.4 ft2
0
0
0.5
0
12
NE
Exterior Concrete Block - Int InsuMAST WIC
4.1 11
2 9
4
104.2 ft2
0
0
0.5
0
7/13/2021 9:18 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPI IT SI IMMARY rWFr-I(1 ICT Q1=pnaT
WALLS
Adjacent
C
Space avity Width
Val,
Height
Sheathing Framing Solar
Below
13 NW
Garage Frame - Wood GRT DIN KIT 11 30 0 9
4 280.0 ft2
0 0 0.5
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Ft
Width Height
In Ft In
Area
1
2
NW
NW
Insulated GRT DIN KIT None
Wood GRT DIN KIT None
.46 3 8 24 ft2
.46 2.8 8 22.4 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V #
Wall
Ornt ID Frame
Panes NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation 1nt Shade
Screening
1
2
3
4
5
6
7
SE 2 Metal
SW 6 Metal
NE 7 Metal
SW 8 Metal
NW 9 Metal
NW 9 Metal
NW 11 Metal
Double (Tinted) Yes
Double (Tinted) Yes
Double (Tinted) Yes
Double (Tinted) Yes
Double (Tinted) Yes
Double (Tinted) Yes
Double (Tinted) Yes
0.28 0.3 N
028 0.3 N
0.28 0.3 N
0.55 0.34 N
0.28 0.3 N
0.28 0.3 N
0.28 0.3 N
15.0 ft2 1 ft 0 in
15.0 ft2 1 ft 0 in
15.0 ft2 1 ft 0 in
41.0 ft2 11 ft 0 in
23.0 ft2 1 ft Din
23.0 ft2 9 ft 6 in
22.9 ft2 1 ft 0 in
1 ft 0 in None
1 ft 0 in None
1 ft 0 in None
1 ft 0 in None
1 ft 0 in None
1 ft 0 in None
1 ft 0 in None
None
None
None
None
None
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
380 ft2
380 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391
1657.2 90.92 170.69 A312
7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COP:1
23 kBtulhr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 29.4 kBtulhr
cfm 0.71 1
sys#1
7/13/2021 9:18 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location EF
Cap
Use
SetPnt
Conservation
1 Electric
None
Garage 0-95
40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert. # Company Name
System Model # Collector
Model
# Area Volume
FEF
None None
ft2
DUCTS
---- Supply ----
---- Return ----
Air
CFM 25
CFM25
HVAC #
1/ # Location R-Value Area
Location Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 300 ft2
HALL BATH 1 ft2
Default Leakage
HALL BAT
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Farts:
Cooling H Ian �Xj Feb
Heating Jan Feb
[[ ]] Mar
[Mar
A r
Apr
[ Ma
[ May
X Jun rlJul
Jun Jul
Au
rj Au
Sep
�Xj Se
Oct Nov
Oct Nov
Dec
Venting Jan Feb
[[X]] Mar
jX
Apr
[ May
[ Jun Jul
Aug
Se
[X]
Oct [X] Nov
�Xj
XDec
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3 4
5 6
7
8
9 10 11
12
Cooling (WD) AM
78
78
78 78
78 78
78
78
80 80 80
80
PM
80
80
78 78
78 78
78
78
78 78 78
78
Cooling (WEH) AM
78
78
78 78
78 78
78
78
78 78 78
78
PM
78
78
78 78
78 78
78
78
78 78 78
78
Heating (WD) AM
66
66
66 66
66 68
68
68
68 68 68
66
PM
68
68
68 68
68 68
68
68
68 68 66
66
Heating (WEH) AM
66
66
66 66
66 68
68
68
68 68 68
68
PM
68
68
68 68
68 68
68
68
68 68 66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ftz
0 ft
0.3
BED 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
WIC BED 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
KITCHEN DINING
Default(8 Ibslsq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 Ibslsq-ft.
ft2
ft
0.3
FOYER
Default(8 Ibslsq.ft,
ft2
ft
0.3
LAUNDRY
Default(8 Ibslsq.ft.
ft2
ft
0.3
M WIC
Default(8 Ibs/sq.ft,
ft2
ft
0.3
M TIOLET
Default(8 Ibslsq.ft.
ft2
ft
0.3
M BATH
Default(8 Ibsls .ft.
ft2
ft
0.3
MASTER SUITE
7tl312021 9:18 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows** Description
a. U-Factor: Dbl, U=0.28
SHGC: SHGC=0.30
b. U-Factor: Dbl, U=0.55
SHGC: SHGC=0.34
c. U-Factor: NIA
SHGC:
d. U-Factor: NIA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): NIA
SHGC(AVG): NIA
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. NIA
c. NIA
5113 ARMiNA PLACE, FT PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1516,70 ft2
b. Frame - Wood, Adjacent
R=11.0
280.00 ft2
1
c. NIA
R=
ft2
4
d. NIA
R=
ftZ
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30 0
1618.00 ft2
1616
b. NIA
R=
ftZ
Area
c. NIA
R=
ft2
113.92 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: HALL BATH, AH: HALL BATH
6 300
41.00 ft2
13. Cooling systems
kBtulhr
Efficiency
ft2
a. Central Unit
29.4
SEER:16.00
ft2
4.909 ft.
0.311
Area
ft2
Insulation Area
R=0.0 1616.00 ft2
R= ft2
R= ftz
14. Heating systems
a. Electric Strip Heat
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
kBtulhr Efficiency
23.0 COP:1.00
Cap: 40 gallons
EF: 0.95
Pstat
w
FS
�tl
' O'D WV
Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/13/2021 0:13 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1