HomeMy WebLinkAboutAPPROVED Lateral toe-nailST-TOENAIL_SP
NOTES:
1. TOE-NAILS SHALL BE DRIVEN AT AN ANGLE OF 45 DEGREES WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT. (NAIL MUST BE DRIVEN THROUGH AND
EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES
FOR MEMBERS OF DIFFERENT SPECIES.
LATERAL TOE-NAIL DETAIL
SIDE VIEW
(2x3, 2x4)
2 NAILS
NEAR SIDE
NEAR SIDE
SIDE VIEW
(2x6)
3 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
TOE-NAIL SINGLE SHEAR VALUES PER NDS 2001 (lb/nail)3.5" LONG3.25" LONGDIAM.SYP SPFDF HF SPF-S
.131
.128
.135
.131
.162
.148
108.8 99.6 86.4 84.5 73.8
63.4
59.768.4
72.6
69.9
74.2
80.6
85.6
88.0
93.5
81.4 74.5 64.6 63.2 52.5
51.1
50.357.6
59.0
58.9
60.3
67.9
69.5
74.2
75.9
VALUES SHOWN ARE CAPACITY PER TOE-NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (.162" diam. x 3.5") WITH SPF SPECIES BOTTOM CHORD
For load duration increase of 1.15:
3 (nails) X 84.5 (lb/nail) X 1.15 (DOL) = 291.5 lb Maximum Capacity
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
ANGLE MAY
VARY FROM
30° TO 60°
45.00°
ANGLE MAY
VARY FROM
30° TO 60°
ANGLE MAY
VARY FROM
30° TO 60°
45.00°45.00°
THIS DETAIL APPLICABLE TO THE
THREE END DETAILS SHOWN BELOW
MiTek Industries, Inc.
R
OCTOBER 1, 2006
MiTek Industries, Chesterfield, MO Page 1 of 1