Loading...
HomeMy WebLinkAboutAPPROVED .PDFGA - 600 - 2006 FIRE RESISTANCE DESIGN MANUAL GYPSUM ASSOCIATION FIRE RESISTANCE DESIGN MANUAL SOUND CONTROL GYPSUM SYSTEMS GA-600-2006 FIRE RESISTANCE DESIGN MANUAL 73 MOVABLE AND OFFICE PARTITIONS GA FILE NO. WP 6152 GENERIC 1 HOUR 40 to 44 STC — FIRE SOUND METAL CLAD GYPSUM PANELS, MINERAL FIBER INSULATION, STEEL STUDS One layer 30" wide metal faced 1/2" type X gypsum wallboard panels applied parallel to each side of 21/2" fabricated steel studs 15" o.c. Metal cladding adhesively attached to wig wallboard. Studs fabricated from two members joined at webs with tabs and having stud flanges formed to provide spring receiving slots to receive edge flanges of cladding. Two layers 2114" wide 5/a" type X gypsum wallboard strips attached to each side of stud webs. First strip attached with 1114" long Type S drywall screws 12" o.c. Second strip attached with 17/8" long Type S drywall screws 24" o.c. and offset 6" from screws in first strip. 2" Thickness: 31/2" mineral fiber insulation, 3.8 pcf friction fit in stud cavities. Clad gypsum panels secured Approx. Weight: 81/2 psf at vertical edges to studs by inserting 15hs" wide flanges of cladding into stud receiving Fire Test: FM WP 495, 11-15-78 slot; flanges of cladding are crimped 12" o.c. forming a %" long by 3/32" deep crimp to Sound Test: KAL 443990, 10-31-78 secure panels to studs. Panels attached to floor and ceiling runners with 11/4" Type S drywall screws located 4" from each corner and one in the middle at the bottom. Joints staggered 15" on opposite sides. (NLB) - GA FILE NO. WP 6210 1 1 GENERIC 1 HOUR 35 to 39 STC FIRE SOUND SOLID GYPSUM WALLBOARD Face layer 24" wide type X gypsum wallboard laminated parallel each side of 1" gypsum cereboard. F Face layer joints aligned on opposite sides and offset 13/4" from coreboard joints to form an interlocking joint. Metal cap track 18 gage 21/a' wide, 3' wide 20 gage snap -in locking base. (NLB) Thickness: 21/4" Limiting Height: 14'0" Approx. Weight: 9 psf Fire Test: UC, 5-24-65 Sound Test: RAL TL64-213, 4-13-64 GA FILE NO. WP 6220 GENERIC 1 HOUR__ff 35 to 39 STC FIRE J SOUND SOLID GYPSUM WALLBOARD Face layer wide Vi' gypsum wallboard laminated parallel to each side of wide 1her core at gypsum core fabricated from two layers 5/e" type X gypsum wallboard laminated together with adhesive over entire contact surfaces. Face layer joints aligned on opposite sides and offset 13/a' from gypsum core joints to form an interlocking joint. Metal cap track 18 gage 2114" wide, 3" wide 20 gage snap -in locking base. (NLB) Thickness: 2114" Limiting Height: 14'0" Approx. Weight: 9 psf t: UC,9-25-56 Sound as. 10 ;;w (RAL TL64- - ) NO. WP 6240 GENERIC 1 HOUR 35 to 39 STC FIRE SOUND SEMI -SOLID GYPSUM WALLBOARD Face laymide typeX gypsum wallboard laminated parallel to each side of 6" wide ar 1" gypsum coreboard studs. Face layer joints aligned on opposite sides and offset from stud edges 1314" to form an interlocking joint. Face layer attached to studs with 1112" long Type G screws 30" o.c. spaced 2" from joint on tongue edge and 4" from joint on groove edge. Panels mounted in floor and ceiling channels. (NLB) Thickness: 21/4" Limiting Height: 12'0" Approx. Weight: 7 psf Fire Test: FM WP'142-1, 1-6-69 Sound Test: RAL TL64-212, 4-13-64