ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Required Sections of
the Permit Application
Form
Attachments Required
See List Below
Low Slope Application
A, B,C
1,8,3,4A6j
Prescriptive BUR-RAS 150
A, B, C
2A,5,6,7
Asphaltic Shingles
A, 8, D
12,45,67
Concrete or Clay Tile
A, B, D. E
1,2.3.4,fi,6,7
Metal Roofs
A, B, D
1.Z%4,6,6,7
Wood Shingles and
Shakes
A, B, D
U,4,6,6,7
Other
As Applicable
1,P,3,4,6,6,7
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
S.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only(
7.
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
ST. LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': _ Zone 1: _ Zone 2: _Zone 3: _
Max. Design Pressure, from the specific product approval
system:
Deck:
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':_"
oc @ Lap, # Rows— ®_oo
Zone 1:—"oc@
Lap, # Rows —®_'oo
Zone 2:—,."
oc @ Lap, # Rows _ ®= oo
Zone 3:
oc @ Lap, # Rows_ 0 _• ac
Number of Fasteners Per Insulation Board:
Zone 1':_Zone 1� Zone 2:_Zone 3
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS ill and Chapter 16..
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Root System Manufacturer: ENGLERT 1120 1" STANDING SEAM
Notice of Acceptance Number: FL#31655.1
Minimum Design Wind Pressures, If AppIicabie {From RAS 127 or Calculations};
Zone 1: -57 zone 2e::-57 Zone 2n .-91Zone 2r: 2 Zone 3e: Zone 3r: -128
Deck Type: I PLYWOOD
Type Un
Roof Slope: derlayment: ELF ADHERED UNDERLAYMENT TO POLYGLASS MTS EL#5259,1
5 12
Insulation:
Fire Barrier:
[RidgeVentilation? Fastener Type &Spacing: 16" FIELD 14" PERIMETER, 8D RINGS NK NAILS
Adhesive Type:
Type Gap Sheet:
Mean Roof Height: 15' FT Roof Covering: METAL
Type & Size Drip
Edge:
ST. LUCIE WORKS
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the Mrvalues
are greaterthan or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _xg1 MU; Mn_ Product Approval Mi
(Zone 2e: _x2-= M9:_=Mr _ Product Approval M,
(Zone 2n: '_xS_= _)-Wg:_=Mm,_ Product Approval Mr
(Zone 2r: _X.X_= _)-Mg:_=Mg_ Product Approval Mr
(Zone 3e: :_X%-= _ I- MT. _=My_ Product ApprovalM
(Zone 3r. _X)._= _)- Mg: _c M,a_ Product Approval Mr
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (MA From Table R.I._ pr„n::. n.,..". -i RA -
Mr required Moment Resistance"
15'
20'
25'
30,
40'
34.4
36.5
38.2
39.7
42.2
3724.4
32.2
34.4
36.0
37.4
39.8
30.4
32.2
33.8
35.1
37.3
28 4
30.1
31.6
32.8
34.9
26.4
28.0
29.4
30.5
32.4
2S.9
27.1
28.2
30.0
--emu „, mquuctiion wim a nst of moment based file systems
• For Uplift based the systems use Method 3. Compare the values for F' with the values for Fr If the F- values are greater than or
equal to the Fr values, for each area of the roof, then the the attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 12T
(Zone 1: _x L_ x W:=---) -W; cos r_ F,t_ Product Approval F
(Zone 2e: _x L= x W:- -) _W cos r-=Fae Product Approval F'
(Zone 2n: _x L=x W:=_J-W; cos rFra: Product Approval F'
(Zone 2r._xL xW:=-)-W;_Cos r=Far_ Product Approval F'
(Zone 3e:_x L_=xW:=_--J-W: cos r= Frx_ Product Approval F'
(Zone 3r. _x L_=x W:=� _W:_ cos r= Far_ Product Approval F' _
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
Zones 1, 2e, 2n, 2r, 3e, 3r
From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
B
Job Site
Aerodynamic MuMplier
a
Product Approval
Restoring Moment due to Gravity
Mt
Product Approval
Attachment Resistance
Mr
Product Approval
Required Moment Resistance
Ma
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
F,
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L=length W=width
Product Approval
All calculations must be submitted to the building official at the time of permit application.