Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED, CONSTRUCTION PLANS esign
SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.G-001SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210JEREMY D SHARIT PE FL LIC 75137TITLE SHEETLOCATION MAPVICINITY MAPKnow what's below. Call before you dig.RCOMPLIANCE CODEPROJECT SUMMARYPROJECT DESCRIPTIONUTILITY COMPANIESPOWER COMPANY: FLORIDA POWER & LIGHT COMPANYPHONE: (800) 226-3545TELEPHONE COMPANY: N/APHONE: N/ASITE LOCATIONSITE ADDRESS:13698 INDRIO RDFORT PIERCE, FL 34945COUNTY: ST. LUCIEGEOGRAPHIC COORDINATES:LATITUDE: 27.55803889LONGITUDE: -80.48158333GROUND ELEVATION: 29.5' AMSL1.THE FACILITY IS UNMANNED.2.A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCEA MONTH FOR ROUTINE INSPECTION AND MAINTENANCE.3.THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LANDDISTURBANCE OR EFFECT OF STORM WATER DRAINAGE.4.NO SANITARY SEWER, POTABLE WATER OR TRASHDISPOSAL IS REQUIRED.5.HANDICAP ACCESS IS NOT REQUIRED.PROJECT NOTESPROJECT LOCATION DIRECTIONSFROM I-95 AT EXIT #138 TRAVEL WEST ON INDRIO ROAD FOR 0.7TENTHS OF A MILE. AT ENTRANCE FOR DICKERSONAGGREGATES TURN RIGHT (NORTH) AND TRAVEL 0.3 TENTHS OFA MILE. NOW STOP AND SIGN IN AT OFFICE TRAILER BY SCALES.AFTER SIGNING IN CONTINUE NORTH ON LOCAL DIRT ROAD ANDFOLLOW FOR 2.6 MILES. WHEN YOU COME TO THE FENCE LINE,TURN RIGHT (EAST). FOLLOW FENCE LINE BACK TO SITE.T-MOBILE SITE NAME: STRAZZULAT-MOBILE SITE NUMBER: A2P0246SSITE ADDRESS:13698 INDRIO RDFORT PIERCE, FL 34945PROJECT TEAMAPPLICANT:T-MOBILETOWER OWNER:AMERICAN TOWER10 PRESIDENTIAL WAYWOBURN, MA 01801PROPERTY OWNER:N/A13698 INDRIO RDFORT PIERCE, FL 34945SHEET INDEXSHEETNO:DESCRIPTION:REV:DATE:BY:G-001TITLE SHEET006/08/21CCCG-002GENERAL NOTES006/08/21CCCC-101DETAILED SITE PLAN006/08/21CCCC-102GROUND EQUIPMENT LAYOUT006/08/21CCCC-201TOWER ELEVATION006/08/21CCCC-401ANTENNA INFORMATION & SCHEDULE006/08/21CCCC-501CONSTRUCTION DETAILS006/08/21CCCC-502EQUIPMENT SPECIFICATIONS006/08/21CCCE-501GROUNDING DETAILS006/08/21CCCR-601SUPPLEMENTALR-602SUPPLEMENTALR-603SUPPLEMENTALTHIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALED BYJEREMY D SHARIT, PE (#75137) USING ADIGITAL SIGNATURE IN ACCORDANCE INACCORDANCE WITH FAC 61G15-23.004,WITH A DIGITAL CERTIFICATION ISSUED BYENTRUST INC. PLEASE VIEW THESIGNATURE VERIFY ITS PROPERTIES.PRINTED COPIES OF THIS DOCUMENT ARENOT CONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONIC COPIES.ENGINEER:JUDSON SOMMERVILLEcainsommerville@smweng.comSMW ENGINEERING GROUP INC.158 BUSINESS CENTER DR.BIRMINGHAM, AL. 35244JOB# 21-5160ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLEDIN ACCORDANCE WITH THE CURRENT EDITIONS OF THEFOLLOWING CODES AS ADOPTED BY THE LOCALGOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS ISTO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TOTHESE CODES.1.2020 FLORIDA BUILDING CODE, 7TH EDITION2.2014 INTERNATIONAL BUILDING CODE (IBC)3.ANSI/TIA-222-G4.6TH EDITION FLORIDA FIRE PREVENTION CODE (NFPA 70)5.2014 NATIONAL ELECTRICAL CODE6.BASIC WIND SPEED: 108 MPH (3-SECOND GUST, VASD) /115 MPH (3-SECOND GUST, VULT)7.CITY/COUNTY ORDINANCEST-MOBILE ANTENNA AMENDMENT PLANSPRINT KEEP CONFIGURATIONLOCAL DIRT ROADTHE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASEDAND TOWER MOUNTED EQUIPMENT AS INDICATED PER BELOW:TOWER WORK:REMOVE (6) ANTENNAS, (9) RRH'S, (3) FILTERS, (9) RET/RCU, (1)FIBER TRUNK, (3) MOUNT, AND (3) HYBRID TRUNKSINSTALL (6) ANTENNAS, (6) RRH'S, (3) VFA10-HD-80, AND (2) HYBRIDTRUNKSEXISTING (1) DISH, (1) ODU AND (1) COAX TO REMAINGROUND WORK:REMOVE ALL SPRINT EQUIPMENTINSTALL (1) 6160 EQUIPMENT CABINET, (1) B160 BATTERY CABINETI-95 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.G-002SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210THIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALEDBY JEREMY D SHARIT, PE (#75137)USING A DIGITAL SIGNATURE INACCORDANCE IN ACCORDANCE WITHFAC 61G15-23.004, WITH A DIGITALCERTIFICATION ISSUED BY ENTRUSTINC. PLEASE VIEW THE SIGNATUREVERIFY ITS PROPERTIES. PRINTEDCOPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONICCOPIES.JEREMY D SHARIT PE FL LIC 75137GENERAL NOTESGENERAL CONSTRUCTION NOTES:1.OWNER FURNISHED MATERIALS, T-MOBILE "THE COMPANY" WILL PROVIDE AND THECONTRACTOR WILL INSTALLA.BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUNDBUILD/CO-LOCATE ONLY)B.AC/TELCO INTERFACE BOX (PPC)C.ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILD/CO-LOCATE ONLY, GCTO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION)D.TOWERS, MONOPOLESE.TOWER LIGHTINGF.GENERATORS & LIQUID PROPANE TANKG.ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTINGH.ANTENNAS (INSTALLED BY OTHERS)I.TRANSMISSION LINEJ.TRANSMISSION LINE JUMPERSK.TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITSL.TRANSMISSION LINE GROUND KITSM.HANGERSN.HOISTING GRIPSO.BTS EQUIPMENT2.THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THECOMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCHMATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB-FRAME FOR PLATFORM,ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES,COPPER-CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS ANDDISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER,CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS ANDRUBBER MATTING, REBAR, CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS,MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES ANDALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TOTHE DRAWINGS AND SPECIFICATIONS. IT IS THE POSITION OF T-MOBILE TO APPLY FORPERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIREDPERMITS.3.ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL, STATE, AND LOCALCODES, INCLUDING ANSI/EIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTIONSPECIFICATIONS.4.CONTRACTOR SHALL CONTACT LOCAL 811 FOR IDENTIFICATION OF UNDERGROUNDUTILITIES PRIOR TO START OF CONSTRUCTION.5.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIREDINSPECTIONS.6.ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, ANDSITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALLDISCREPANCIES REPORTED TO THE ENGINEER.7.DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS.8.DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESSOTHERWISE NOTED.9.THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTIONSAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.10.CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDEDFOR STABILITY ARE INSTALLED. THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING,ANCHOR BOLTS, ETC.11.CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDSDRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCING WORK.12.INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING ORNONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILEREP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALLREQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING.13.EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP, AND COORDINATE HISWORK WITH THE WORK OF OTHERS.14.CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THISPROJECT TO MATCH EXISTING PRE-CONSTRUCTION CONDITIONS TO THE SATISFACTIONOF THE T-MOBILE CONSTRUCTION MANAGER.15.ALL CABLE/CONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURINGINSTALLATION USING A SILICONE SEALANT.16.WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET,CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORDIMMEDIATELY.17.CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETEAND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT.18.CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OFEACH DAY.19.CONTRACTOR SHALL COORDINATE WORK SCHEDULE WITH AMERICAN TOWERCORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OFOTHER OCCUPANTS OF THE FACILITY.20.CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC)WITH A PDF MARKED UP AS-BUILT SET OF DRAWINGS UPON COMPLETION OF WORK.21.PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REPTO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDEDSHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR WILL INSTALLALL ITEMS PROVIDED.22.PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REPTO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIREDPERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THECONTRACTOR.23.CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILESPECIFICATIONS AND REQUIREMENTS.24.CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW ANDAPPROVAL PRIOR TO FABRICATION.25.ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'SSPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND ASSHOWN IN THESE PLANS.26.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTIONMEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FORCOORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT.27.CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 48 HOURS IN ADVANCE OFPOURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS ORSEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW ANDAPPROVAL.28.CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WITHALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALLNECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICESSUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING,TRENCH BOXES/SLOPING, BARRIERS, ETC.29.THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES ANDSUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANYDAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HISREPRESENTATIVES, OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THISCONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HISWORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HISEXPENSE TO THE OWNER'S SATISFACTION.30.ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNERBY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIPSHALL BE SUBJECT TO THE APPROVAL OF THE T-MOBILE REP. ANY WORK FOUND BYTHE T-MOBILE REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BEREPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL ISOBTAINED.31.IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OFMATERIALS LISTED HEREINAFTER BY MANUFACTURER’S NAMES AND/ORMANUFACTURER’S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERSAS SPECIFIED.32.T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED-UP AT THE T-MOBILE WAREHOUSE,NO LATER THAN 48HR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTEDAND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REQUIRED TO PLACETHE EQUIPMENT IN OPERATION, READY FOR USE. THE CONTRACTOR SHALL BERESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP.33.T-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANYEQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITHTHE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THEEQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THEREQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TOT-MOBILE OR THEIR ARCHITECT/ENGINEER.SPECIAL CONSTRUCTIONANTENNA INSTALLATION NOTES:1.WORK INCLUDED:A.ANTENNA AND COAXIAL CABLES ARE FURNISHED BY T-MOBILE UNDER ASEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNAINSTALLATION CONTRACTOR IN TERMS OD COORDINATION AND SITE ACCESS.ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OFPERSONNEL ANDB.INSTALL ANTENNA AS INDICATE ON DRAWINGS AND T-MOBILE SPECIFICATIONS.C.INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGSD.INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE.E.CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF SWEEP TESTS USINGANRITZU-PACKARD 8713B RF SCALAR NETWORK ANALYZER. SUBMIT FREQUENCYDOMAIN REFLECTOMETER(FDR) TESTS RESULTS TO THE PROJECT MANAGER.SWEEP TESTS SHALL BE AS PER ATTACHED RFS "MINIMUM FIELD TESTINGRECOMMENDED FOR ANTENNA AND HELIAX COAXIAL CABLE SYSTEMS" DATED10/5/93. TESTING SHALL BE PERFORMED BY AN INDEPENDENT TESTING SERVICEAND BE BOUND AND SUBMITTED WITHIN ONE WEEK OF WORK COMPLETION.F.INSTALL COAXIAL CABLES AND TERMINATING BETWEEN ANTENNAS ANDEQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALLCONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'SREQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OFENTRY PORT LOCATION UNLESS OTHERWISE STATED.G.ANTENNA AND COAXIAL CABLE GROUNDING:2.ALL EXTERIOR #6 GREED GROUND WIRE "DAISY CHAIN" CONNECTIONS ARE TO BEWEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT #221213 OREQUAL.3.ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OFCOAXIAL CABLE (NOT WITHIN BENDS)ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESECONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATCENGINEERING IMMEDIATELY FOR CORRECTION OR RE-DESIGN. FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING ORANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIORAPPROVAL FROM ATC ENGINEERING SHALL BE THE SOLERESPONSIBILITY OF THE GENERAL CONTRACTOR. SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-101SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210THIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALEDBY JEREMY D SHARIT, PE (#75137)USING A DIGITAL SIGNATURE INACCORDANCE IN ACCORDANCE WITHFAC 61G15-23.004, WITH A DIGITALCERTIFICATION ISSUED BY ENTRUSTINC. PLEASE VIEW THE SIGNATUREVERIFY ITS PROPERTIES. PRINTEDCOPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONICCOPIES.JEREMY D SHARIT PE FL LIC 75137DETAILED SITE PLANSITE PLAN NOTES:1.THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITEPRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT.2.ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALLPROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. BEFORE UTILIZING EXISTING CABLE SUPPORTS, COAX PORTS, INSTALLING NEWPORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS.3.THIS PROJECT INCLUDES NO INSTALL OR MODIFICATION AT GRADE. LEGENDAUTOMATIC TRANSFER SWITCHATSDISCONNECTDELECTRICALEFIBERFBOLLARDBGENERATOR RECEPTACALGHAND HOLE, VAULTHH, VICE BRIDGEIBKENTROX BOXKGENERATORGENMETERMLIGHTING CONTROLLCPULL BOXPBPOWER POLEPPTELCOTTRANSFORMERTRNXCHAINLINK FENCEGROUNDING TEST WELLCELL SITE CABINETCSC1DETAILED SITE PLAN010'20'SCALE: 1"=10' (11X17) 1"=5' (22X34)(MODIFIED AS REQUIRED FOR UPGRADETO NEW BUILD_SPRINT KEEPCONFIGURATION)1R-6011C-102PROPOSED (2) HYBRID TRUNKS(ROUTED PER PROPOSED CABLELENGTH NOTE 2)(REFER TO PROPOSED CABLELENGTH NOTE ON THIS PAGE)(1) FIBER TRUNK(3) HYBRID TRUNK(TO BE REMOVED)PROPOSED CABLE LENGTH:1.ESTIMATED LENGTH OF PROPOSED CABLE IS 156'.ESTIMATED LENGTH OF CABLE WAS PROVIDED BYCUSTOMER OR CALCULATED BY ADDING THE RADCENTER AND THE DISTANCE FROM THE SHELTERENTRY PLATE TO THE TOWER (ALONG THE ICEBRIDGE) AND A SAFETY FACTOR MEASUREMENT OF15% (OF THE TWO PREVIOUS VALUES), CDS DEFERTO GREATEST CABLE LENGTH.2.ROUTE PROPOSED CABLES ALONG SAME PATH ASEXISTING CABLES AND IN ACCORDANCE WITHSTRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZEEXISTING CABLE SUPPORT STRUCTURES ASPROVIDED FOR CARRIER TO ADEQUATELY SECURECABLES, USING EITHER APPROPRIATELY SIZEDSTAINLESS STEEL SNAP-INS OR MOUNTINGHARDWARE AND BRACKETS AS SPECIFIED BY CABLEMANUFACTURER. OTHERWISE, ATTACH CABLES TOHORIZONTAL OR DIAGONAL TOWER MEMBERSUSING PROPOSED STAINLESS STEEL ADAPTERS (DONOT ATTACH TO TOWER LEG). SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-102SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210THIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALEDBY JEREMY D SHARIT, PE (#75137)USING A DIGITAL SIGNATURE INACCORDANCE IN ACCORDANCE WITHFAC 61G15-23.004, WITH A DIGITALCERTIFICATION ISSUED BY ENTRUSTINC. PLEASE VIEW THE SIGNATUREVERIFY ITS PROPERTIES. PRINTEDCOPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONICCOPIES.JEREMY D SHARIT PE FL LIC 75137DETAILED GROUNDPLAN1EXISTING GROUND EQUIPMENT LAYOUT2PROPOSED GROUND EQUIPMENT LAYOUT05'10'SCALE: 1"=5' (11X17) 1"=2.5' (22X34)05'10'SCALE: 1"=5' (11X17) 1"=2.5' (22X34)LEGENDEXISTING EQUIPMENTTO BE REMOVEDLEGENDPROPOSED EQUIPMENTTO BE INSTALLEDSITE PLAN NOTES:1.CONTRACTOR TO VERIFY THERE IS NO LIVE AAV FIBER RUNNING THROUGH EXISTING DEADEQUIPMENT. IF SO, THIS WILL NEED TO BE RERUN THROUGH CONDUIT PRIOR TO REMOVINGDEAD 2G (6201 CABS) EQUIPMENT.2.REMOVE EXISTING 2G CABINETS, AND POWER / TELCO WHIPS ASSOCIATED WITH THE DEADEQUIPMENT IF APPLICABLE.3.ALL OPEN PORTS NEED TO BE SEALED / WEATHERPROOFED PROPERLY4.ALL UNNEEDED / EXCESS EQUIPMENT AND GARBAGE TO BE REMOVED FROM EQUIPMENT AREA.DISPOSE OF MATERIALS PROPERLY OFF SITE.(1) FIBER TRUNK(3) HYBRID TRUNK(TO BE REMOVED)PROPOSED(2) 1.99" HYBRID TRUNKSPROPOSED 6160EQUIPMENT CABINET2R-602PROPOSED B-160BATTERY CABINET1R-602(TO BE REMOVED)(TO BE REMOVED) SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-201SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210THIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALEDBY JEREMY D SHARIT, PE (#75137)USING A DIGITAL SIGNATURE INACCORDANCE IN ACCORDANCE WITHFAC 61G15-23.004, WITH A DIGITALCERTIFICATION ISSUED BY ENTRUSTINC. PLEASE VIEW THE SIGNATUREVERIFY ITS PROPERTIES. PRINTEDCOPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONICCOPIES.JEREMY D SHARIT PE FL LIC 75137TOWER ELEVATIONPROPOSED T-MOBILERAD CENTER @132'TOWER NOTE:1.IT IS THE CONTRACTOR'S RESPONSIBILITY TOCONFIRM WITH THE PROJECT MANAGER THATTHEY HAVE THE MOST RECENT VERSION OF THESTRUCTURAL ANALYSIS BEFORE COMMENCINGWORK. EXISTING AND PROPOSED TOWERAPPURTENANCES, MOUNTS, AND ANTENNAS ARESHOWN BASED ON THE STRUCTURAL ANALYSIS.2.WHERE APPLICABLE, ALL NEW ANTENNAS,EQUIPMENT, MOUNTS, CABLING, ETC. SHALL BEPAINTED/SOCKED TO MATCH EXISTING EQUIPMENTIN ACCORDANCE WITH FAA, JURISDICTION, AND/OROTHER LOCAL REQUIREMENTS.3.ROUTE PROPOSED CABLES ALONG SAME PATH ASEXISTING CABLES AND IN ACCORDANCE WITHSTRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZEEXISTING CABLE SUPPORT STRUCTURES ASPROVIDED FOR CARRIER TO ADEQUATELY SECURECABLES, USING EITHER APPROPRIATELY SIZEDSTAINLESS STEEL SNAP-INS OR MOUNTINGHARDWARE AND BRACKETS AS SPECIFIED BYCABLE MANUFACTURER. OTHERWISE, ATTACHCABLES TO HORIZONTAL OR DIAGONAL TOWERMEMBERS USING PROPOSED STAINLESS STEELADAPTERS (DO NOT ATTACH TO TOWER LEG).4.TOWER ELEVATIONS ARE MEASURED FROM TOPOF BASE PLATE TO MATCH STRUCTURALANALYSIS. ELEVATIONS DO NOT REFLECT TRUEABOVE GROUND LEVEL (A.G.L.)1TOWER ELEVATIONSCALE: N.T.S.2C-501PROPOSED T-MOBILEEQUIPMENT1C-501PROPOSED(2) 1.99" HYBRID TRUNKSTHE EXISTING MOUNT CAN NOT ADEQUATELYSUPPORT THE PROPOSED LOADING. THEPROPOSED MOUNT, DETAILED AT THE END OFTHIS PLAN SET, MUST BE INSTALLED PRIOR TOTHE INSTALLATION OF THE PROPOSEDANTENNAS AND OTHER EQUIPMENT SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-401SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210THIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALEDBY JEREMY D SHARIT, PE (#75137)USING A DIGITAL SIGNATURE INACCORDANCE IN ACCORDANCE WITHFAC 61G15-23.004, WITH A DIGITALCERTIFICATION ISSUED BY ENTRUSTINC. PLEASE VIEW THE SIGNATUREVERIFY ITS PROPERTIES. PRINTEDCOPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONICCOPIES.JEREMY D SHARIT PE FL LIC 75137RF SCHEDULE ANDANTENNA INSTALLATION1EXISTING ANTENNA PLAN2FINAL ANTENNA PLANLEGENDEXISTING EQUIPMENTTO BE REMOVEDLEGENDPROPOSED EQUIPMENTTO BE INSTALLED1.CONFIRM WITH T-MOBILE REPFOR APPLICABLEUPDATES/REVISIONS ANDMOST RECENT RFDS FOR NSNCONFIGURATION (CONFIG). GCTO CAP ALL UNUSED PORTS.2.CONFIRM SPACING OFPROPOSED EQUIP DOES NOTCAUSE TOWER CONFLICTSNOR IMPEDE TOWER CLIMBINGPEGS.NOTESA1B1AZ.=ALPHA90°AZ.= BET A 200°(TO BE REMOVED)(TYP. 6)(TO BE REMOVED)(3 PER SECTOR) (TYP. 9)C1AZ.=GAMMA350°A2AZ.=ALPHA90°B2AZ. = BET A 200°C2AZ.=GAMMA350°FINAL ANTENNA SCHEDULELOCATIONANTENNA SUMMARYNON ANTENNA SUMMARYSECTORRADAZPOSANTENNABANDMECH/ELECD-TILTSTATUSADDITIONAL TOWERMOUNTED EQUIPMENTSTATUSALPHA132'90°A1FFVV-65C-R3-V1L700,L600,N600,L1900,G1900,L2100-ADDRADIO 4460 B25,B66RADIO 4480 B71,B85ADDADDA2AIR6449 B41L2500, N2500-ADD--BETA132'200°B1FFVV-65C-R3-V1L700,L600,N600,L1900,G1900,L2100-ADDRADIO 4460 B25,B66RADIO 4480 B71,B85ADDADDB2AIR6449 B41L2500, N2500-ADD--GAMMA132'350°C1FFVV-65C-R3-V1L700,L600,N600,L1900,G1900,L2100-ADDRADIO 4460 B25,B66RADIO 4480 B71,B85ADDADDC2AIR6449 B41L2500, N2500-ADD--(TO BE REMOVED)(1 PER SECTOR) (TYP. 3)PROPOSEDFFVV-65C-R3-V1 ANTENNA(1 PER SECTOR) (TYP. 3)PROPOSED 4460 RRU STACKED(1 PER SECTOR) (TYP. 3)PROPOSED 4480 RRU STACKED(1 PER SECTOR) (TYP. 3)PROPOSEDAIR6449 ANTENNA(1 PER SECTOR) (TYP. 3)3ANTENNA AND RF SCHEDULECURRENT FIBER DISTRIBUTION/OVP BOXCURRENT CABLING SUMMARYMODEL NUMBERSTATUSCOAXHYBRIDSTATUSRMV:TO BE REMOVEDTO REMAINREL:TO BE RELOCATEDDSC:TO BE DISCONNECTED& REMAINADD:TO BE ADDEDSTATUS ABBREVIATIONSPROPOSED FIBER DISTRIBUTION/OVP BOXPROPOSED CABLING SUMMARYMODEL NUMBERSTATUSCOAXHYBRIDSTATUS---(2) HCS 2.0 (156')ADD-----PROPOSED VFA10-HD80(1 PER SECTOR) (TYP. 3)(TO BE REMOVED)(TYP. 3)THE EXISTING MOUNT CAN NOT ADEQUATELYSUPPORT THE PROPOSED LOADING. THEPROPOSED MOUNT, DETAILED AT THE END OFTHIS PLAN SET, MUST BE INSTALLED PRIOR TOTHE INSTALLATION OF THE PROPOSEDANTENNAS AND OTHER EQUIPMENT SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-501SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210THIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALEDBY JEREMY D SHARIT, PE (#75137)USING A DIGITAL SIGNATURE INACCORDANCE IN ACCORDANCE WITHFAC 61G15-23.004, WITH A DIGITALCERTIFICATION ISSUED BY ENTRUSTINC. PLEASE VIEW THE SIGNATUREVERIFY ITS PROPERTIES. PRINTEDCOPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONICCOPIES.JEREMY D SHARIT PE FL LIC 75137CONSTRUCTIONDETAILSPROPOSED RRU MOUNT LOCATION (OPTION 2)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)PROPOSED RRU MOUNT LOCATION (OPTION 1)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)PROPOSED RRU MOUNT LOCATION (OPTION 3)(MOUNT PER MANUFACTURER'S SPECS)(ENSURE THAT BRACKET DOES NOT CONFLICT WITHEXISTING OR PROPOSED EQUIPMENT)3PROPOSED RRU MOUNTING DETAIL - TYPICALSCALE: N.T.S.TO BE REPLACED WITH PROPOSED 2-3/8" O.D. X 96" LONGIF REQUIRED TO ACCOMMODATE PROPOSED MOUNTING BRACKETPROPOSED ANTENNA1PROPOSED ANTENNA MOUNTING DETAIL - TYPICALSCALE: N.T.S.PROPOSED 2-3/8" O.D. X 96" LONGPROPOSED ANTENNA2PROPOSED 5G ANTENNA MOUNTING DETAIL - TYPICALSCALE: N.T.S.PROPOSED SECTOR FRAMEPROPOSED SECTOR FRAMEPROPOSED SECTOR FRAME SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.C-502SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210THIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALEDBY JEREMY D SHARIT, PE (#75137)USING A DIGITAL SIGNATURE INACCORDANCE IN ACCORDANCE WITHFAC 61G15-23.004, WITH A DIGITALCERTIFICATION ISSUED BY ENTRUSTINC. PLEASE VIEW THE SIGNATUREVERIFY ITS PROPERTIES. PRINTEDCOPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONICCOPIES.JEREMY D SHARIT PE FL LIC 75137EQUIPMENTSPECIFICATIONSA BCFRONT VIEWTOP VIEWSIDE VIEWCFRONT VIEWSIDW VIEWACB TOP VIEW1EQUIPMENT SPECIFICATIONSSCALE: N.T.S.ANTENNA SPECIFICATIONSANTENNA MODELABCWEIGHT(LBS)FFVV-65C-R3-V195.9"25.2"9.3"124.6AIR6449 B4133.1"20.6"8.6"104.0RRU SPECIFICATIONSRRU MODELABCWEIGHT(LBS)4480 B71/B85A21.8"15.7"7.5"84.04460 B25/B6619.6"15.7"12.1"109.0 SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.E-501SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210THIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALEDBY JEREMY D SHARIT, PE (#75137)USING A DIGITAL SIGNATURE INACCORDANCE IN ACCORDANCE WITHFAC 61G15-23.004, WITH A DIGITALCERTIFICATION ISSUED BY ENTRUSTINC. PLEASE VIEW THE SIGNATUREVERIFY ITS PROPERTIES. PRINTEDCOPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONICCOPIES.JEREMY D SHARIT PE FL LIC 75137GROUNDING DETAILSNOTES:1.THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS. SLIGHTADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THECONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THECONSTRUCTION MANAGER OF ANY CONFLICTS.2.SITE GROUNDING SHALL COMPLY WITH T-MOBILE GROUNDING STANDARDS, LATESTEDITION, AND COMPLY WITH T-MOBILE GROUNDING CHECKLIST, LATEST VERSION. WHENNATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN.PROPOSED CONNECTOR ANDWEATHERPROOFING KIT1TYPICAL ANTENNA GROUNDING DIAGRAMSCALE: N.T.S.PROPOSED ANTENNAPROPOSED JUMPERPROPOSED WEATHERPROOFING KIT2E-5013E-501GROUND BAR MOUNTEDNEAR/BELOW ANTENNA(TO BE INSTALLED IFREQUIRED)#6 AWG STRANDED CUWIRE WITH GREEN, 600V,THWN INSULATIONANTENNA CABLE TOCABINET (TYP.)PROPOSED CABLEGROUND KITPROPOSED #6 AWGSTRANDED CUWIRE WITH GREEN, 600V,THWN INSULATION TO PROPOSED RRUGROUND LUG (TYP.)PROPOSED #6 AWGSTRANDED CUWIRE WITH GREEN, 600V,THWN INSULATION TO PROPOSED OVP BOXDO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECTGROUND WIRE DOWN TO GROUND BAR.CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT (ANDREW PARTNUMBER 221213) AND INSTALL/TAPE PER MANUFACTURER'S SPECIFICATIONS.2CABLE GROUND KIT CONNECTION DETAILSCALE: N.T.S.TO ANTENNATO EQUIPMENTTO GROUND BARANTENNA CABLE 2 1/2"Ø MAXGROUNDING KIT PER CABLEMANUFACTURER'S RECOMMENDATIONS(ANDREW OR APPROVED EQUAL)#6 AWG STRANDED COPPER GROUNDWIRE (GROUNDED TO GROUND BAR)GROUND KIT NOTES:1.2.1/4" X 4" X 6" GROUND BAR(ERICO P/N: EGBA14406CC OR EQUAL)3TOWER GROUND BAR DETAILSCALE: N.T.S.GROUND BAR NOTES:1.GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS,WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S).2.GROUND BAR TO BE BONDED DIRECTLY TO TOWER.3/8" SS LOCK WASHER(EACH SIDE)TWO-HOLE LUG, TO BE USEDWITH #2 AWG BCW(LOWER TOWER GROUNDBAR ONLY)3/8" X 1-1/2" SS BOLT(EACH SIDE) SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-601SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210THIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALEDBY JEREMY D SHARIT, PE (#75137)USING A DIGITAL SIGNATURE INACCORDANCE IN ACCORDANCE WITHFAC 61G15-23.004, WITH A DIGITALCERTIFICATION ISSUED BY ENTRUSTINC. PLEASE VIEW THE SIGNATUREVERIFY ITS PROPERTIES. PRINTEDCOPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONICCOPIES.JEREMY D SHARIT PE FL LIC 75137SUPPLEMENTALNOTE: THIS SHEET CREATED BY OTHERS AND PROVIDEDBY REQUEST OF CUSTOMER WITHOUT EDIT. SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-602SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210THIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALEDBY JEREMY D SHARIT, PE (#75137)USING A DIGITAL SIGNATURE INACCORDANCE IN ACCORDANCE WITHFAC 61G15-23.004, WITH A DIGITALCERTIFICATION ISSUED BY ENTRUSTINC. PLEASE VIEW THE SIGNATUREVERIFY ITS PROPERTIES. PRINTEDCOPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONICCOPIES.JEREMY D SHARIT PE FL LIC 75137SUPPLEMENTAL SHEET NUMBER:REVISION:Copyright © 2021 ATC IP LLC, All Rights Reserved.R-603SEAL:DESCRIPTIONREV.DATEBYATC TOWER SERVICES, LLC3500 REGENCY PARKWAYSUITE 100CARY, NC 27518PHONE: (919) 468-0112COA: 7442THE USE AND PUBLICATION OF THESE DRAWINGSSHALL BE RESTRICTED TO THE ORIGINAL SITE FORWHICH THEY ARE PREPARED. ANY USE ORDISCLOSURE OTHER THAN THAT WHICH RELATESTO AMERICAN TOWER OR THE SPECIFIED CARRIERIS STRICTLY PROHIBITED. NEITHER THE ARCHITECTNOR THE ENGINEER WILL BE PROVIDING ON-SITECONSTRUCTION REVIEW OF THIS PROJECT.CONTRACTOR(S) MUST VERIFY ALL DIMENSIONSAND ADVISE AMERICAN TOWER OR THE SPECIFIEDCARRIER OF ANY DISCREPANCIES. ANY PRIORISSUANCE OF THIS DRAWING IS SUPERSEDED BYTHE LATEST VERSION.DATE DRAWN:05/28/21ATC JOB NO:STRAZZULACUSTOMER ID:13348398A2P0246SCUSTOMER #:T Mobile©5120ATC SITE NAME:STRAZZULASTRAZZULA13698 INDRIO RDFORT PIERCE, FL 34945ATC SITE NUMBER:SITE ADDRESS:T-MOBILE SITE NAME:158 BUSINESS CENTER DRIVEBIRMINGHAM, AL 35244TEL: 205-252-6985 FAX: 205-320-15040FOR CONSTRUCTION TI06/08/210THIS DOCUMENT HAS BEENELECTRONICALLY SIGNED & SEALEDBY JEREMY D SHARIT, PE (#75137)USING A DIGITAL SIGNATURE INACCORDANCE IN ACCORDANCE WITHFAC 61G15-23.004, WITH A DIGITALCERTIFICATION ISSUED BY ENTRUSTINC. PLEASE VIEW THE SIGNATUREVERIFY ITS PROPERTIES. PRINTEDCOPIES OF THIS DOCUMENT ARE NOTCONSIDERED SIGNATURE MUST BEVERIFIED ON ANY ELECTRONICCOPIES.JEREMY D SHARIT PE FL LIC 75137SUPPLEMENTALNOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMERWITHOUT EDIT. PLEASE REFERENCE THE MOUNT ANALYSIS REPORT FOR COMPLETE MOUNTANALYSIS CALCULATIONS AND DETAILS. SUPPLEMENTAL PAGES INCLUDED IN THECONSTRUCTION DRAWINGS ARE FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TOVERYIFY THEY HAVE THE MOST RECENT MOUNT ANALYSIS PRIOR TO CONTRUCTION.1MOUNT DETAILS