Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Heikoop Condo Remodel_Plans SS(1)
DocuSign Envelope ID:513DE3E5-BD6E-49A2-8F3F-686CE012AB90 E 0 u 'o 00E nrn d® �N N J J LLa .v rc« (n w W W �_o Remove Drywall 'N �o for MEP Work; ° Wall to be Restored W w Q aom Per Fire Wall Rating 0�O A NNm Q p-O LU Q 0 M).. N o r)i". WU' N.n... A < C[ U —C BEDROOM Ceilings to be MASTER BEDROOM Removed and Replaced as 0 Needed> — a GUEST BATH e $ MASTER BATH m ww O � 8 O Remove & Replace Drywall for MEP o Work (Typ) J F O W O X a KITCHEN O LIVING ROOM O PATIO Ceilings to be LL Removed and Replaced as m Needed 0 O O A J o W � 0 0 " m v DocuSigned by: z 7' A **It has been verified W W D Remove Drywall ,,����������� that existing slabs above o Y E for MEP Work; PGE 0'''p and below unit are not O .�o........Zv'. Wall to be Restored ;``o � post—tensioned o 0 Per Fire Wall Rating No 73135 Y O w • - 2 U a` DocuSigned by: .9'; STATE of0. 21-027 ��,',SS,ONA1��Cl�• 869962A601 A941 C... J-1 DocuSign Envelope ID:513DE3E5-BD6E-49A2-8F3F-686CE012AB90 E 0 0 'o 00E nrn d® �N N J J LLa .v Typical Drop— Down Ceiling Framing GENERAL STRUCTURAL NOTES N jE Applicable Codes ft� �N A. Construction shall be in accordance ft�a- w 60 Q with the 7th Edition of the 2020 w a oco 25 Go. Stud Runner Attached to 18 Ga. L2"x2"x4" Clip Angle @ 16"o.c. Florida Building Code and ASCE 7-16. z a0�"r Clip Angle w/ (2) #7 Tek Screws w/ 0.145"xO.5" Shot Pins @ 12"o.c. The above shall govern except where N N� other applicable codes or the � Wrl Section A— A Fire Wall construction drawings are more Nor)r, a d restrictive. o �v d 4 Existing Concrete Slab Over Precast Form Metal Framina Panels; A. Studs shall be 25 gauge metal and (No Post—Tension) Existing Reinforced meet the Steel Stud Manufacturers Concrete Slab; Association Standards. (No Post—Tension) B. End studs shall be seated firmly in the top and bottom runner tracks. 25 Ga. 1j" vertical Framing C. All lateral bracing must be fastened at Stud @ 16" o.c. Attached the time wall is erected. s to Steel Stud Runner w/ D. Use a minimum of 3 Studs at wall I= (3) #7 Tek Screws Existing 25 Ga. corners and intersections. o Top Channel E. All screw connections are based on CCFSS Technical Bulletin Vol. 2 No. 1 e $ 41 which outlines the AISI Specifications m Typical 25 Ga. 1ng Drop for screw connections. A J» clearance w e Down Ceiling Framing R-11 Batts Insulation w/ Type 'X' Drywall (to bear uL must be maintained from all edges of 25 Ga. 1 Horizontal. Framing Stud © J" Drywall w/ #7-1" or Cement Board Classification Mark) steel members. 16" o.c. Attached to Steel Stud Runner Drywall Screws F. Power driven fastener system, w/ (3) #7 Tek Screws expansion anchors, masonry screws, and adhesive anhor system g" Type 'x' Drywall or connections are based on literature 1n Cement Board over 1" PT 25 Ga. Metal studs @ 16" a.c. published by Hilti Fastening System, o LLI Furring strips 16" o.c. Inc. Alternate fasteners in accordance z to Hilti specifications are acceptable. a Remodel Unit Neighbor Unit Verification of Construction Conditions o A. Dimensions and elevations of construction are for bidding only. B. Contractor shall inspect existing conditions and verify dimensions, Typical Ceiling Framing Existing 25 Ga. elevations, etc.. which affect the scope Bottom Channel on the construction drawings. M C. The Engineer of Record shall be 25 Ga. Stud Runner Attached to 18 Ga. L2"x2"x4" Clip Angle @ 16"o.c. notified of any variations or LL Clip Angle w/ (2) #7 Tek Screws w/ 0.145"xO.5" Shot Pins @ 12"o.c. discrepancies on the construction drawings. Any variations of the constructions drawings without the N ° Engineer of Record consent are the 15 ° Existing Reinforced responsibility of the contractor and ° Existing Concrete Slab Concrete Slab; owner. d Over Precast Form Panels; (No Post—Tension) UL DESIGN U419 D. The construction drawings depict a (No Post—Tension) WALL RATING — 1 HOUR W o finished product and all temporary 0 bracing and means and methods of DocuSigned by: construction are the responsibility of � the Contractor. W W E. All framing, drywall, and insulation ° 25 Ga. 1 Framing Stud @ 16" ,� ,1°PCE's �9'•, products shall be furnished and p O.C. Attached to Steel Stud " Drywall w/ #7-1" No 73135 installed in accordance to all applicable 0- 0 0 Runner w 3 7 Tek Screws Drywall Screws / ( ) # *: :*= governing codes and manufacturer °o z N specifications. = c) STATE OF .QJ a` DocuSigned by: ''0�E`' .<oa�Q� .ON.. �aO,, 21-027 E 869962A601 A941 C... S-2