HomeMy WebLinkAboutAPPROVED, Corrected Plans R21 MBI 36'-0' FRONT ELEVATION PROPOSED BILLBOARD SCALE: N.T.S. 1 MBI COMPANIES INC. 299 N. VVEISGARBER RD. KNOXVILLE, TN 37919 PHONE 865.584.0999 SIGN-ENGINEER.COM PROJECT: MILE MARKER 135, 1-95, FORT PIERCE, FL DRAWING TITLE: BILLBOARD AND CONNECTION TO POLE BY AD GRAPHICS 18" 0 x 0.375" WALL STEEL TORSION PIPE (50 KSI) CALCULATIONS INCLUDE THE FOLLOWING CONSIDERATIONS AS OUTLINED IN THE 2020 FLORIDA BUILDING CODE (7th ED.) : CHAPTER 16-LOADS AND FORCES CHAPTER 17-SPECIAL INSPECTIONS CHAPTER 18- SOILS AND FOUNDATIONS CHAPTER19-CONCRETE CHAPTER 20-ALUMINUM CHAPTER 21-MASONRY CHAPTER 22-STEEL CHAPTER 23-WOOD *ALL SIGNS SHALL BE COMPLIANT WITH CURRENT NEC CODES* GRADE --777- 10 AF 18'-6" SQUARE SPREAD FOUNDATION FRONT VIEW „ SCALE: N.T.S. 2 NOTE: MAXIMUM WATTAGE (FULL POWER; PURE WHITE) * 8,971 WATTS AT FULL BRIGHTNESS * 2,781 AVG RUNNING WATTS ELECTRICAL POWER REQUIREMENTS * 81.6A PER LEG @ 120 V SINGLE PHASE ** 3 WIRE - 1 LIVE, 1 GROUND, 1 NEUTRAL * 40.8A PER LEG @ 120/240 V SPLIT PHASE ** 4 WIRE - 2 LIVE, 1 GROUND, 1 NEUTRAL * 27.2A PER LEG @ 120/208 V THREE PHASE ** 5 WIRE - 3 LIVE, 1 GROUND, 1 NEUTRAL 10'-6" x 36' DIGITAL BILLBOARD SPREAD FOUNDATION REQUIRED REINFORCEMENT #8 BAR @ 12" O.C. MAX. EACH WAY T+B #5 BAR VERT. AS REQ'D TO HOLD REBAR MATS IN PLACE DRAWN BY: I CHECKED BY: COMM. NO. DEW FCM 1 210231.001 CORP. LIC. # F02000002650 BUS. LIC. # AA26000828 ENG. C.O.A. # 29794 NOTES 1.) SEE MANUFACTURERS DRAWINGS FOR ADDITIONAL DETAILS AND DIMENSIONS. 2.) SIGN CABINET AND CONNECTION BY AD GRAPHICS. * CLIENT - AD GRAPHICS * 2020 FLORIDA BUILDING CODE 7TH ED. * RISK CATEGORY II * 160 MPH WIND SPEED, EXP. C * (1) POLE, (1) FOOTING THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY DARREN S. ANTLE, P.E. USING A DIGITAL SIGNATURE AND DATE. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. Darren S. Antli DATE: 03/04/21 DRAWING NO DWG. REV # DATE DRAWN BY 1 08/04/21 DEW REV #2 08/24/21 DSA Digitally signe by Darren S. DpOb�� S E r� 09:59.091304 O D O 7yoa STATE � o o p °Op s p F� 00 o o a0000000 Om.-ONA 4 — ! P.E. LIC # 76813 1 6 T N \AIAVi7 T/f) 2 CALCULATIONS INCLUDE THE FOLLOWING CONSIDERATIONS AS OUTLINED IN THE 2020 FLORIDA BUILDING CODE (7th ED.) : CHAPTER 16-LOADS AND FORCES CHAPTER 17-SPECIAL INSPECTIONS CHAPTER 18- SOILS AND FOUNDATIONS CHAPTER19-CONCRETE CHAPTER 20-ALUMINUM CHAPTER 21-MASONRY CHAPTER 22-STEEL CHAPTER 23-WOOD *ALL SIGNS SHALL BE COMPLIANT WITH CURRENT NEC CODES* TRANSITION PLATE SHOWN 36-0„ FOR ORIENTATION CATWALK BY OTHERS, TYP. SEE DETAIL 3 \-- W10x12 UPRIGHT, TYP. 18" 0 x 0.375" WALL STEEL TORSION PIPE (50 KSI) LED DISPLAY BY OTHERS —11 TOP VIEW SECTION i SCALE: N.T.S. 39"x39"04" THICK STABILIZER PLATE W27X84 WRAP BEAM (41" LONG) 91TAL BILLBOARD GUSSET DETAIL 7, DWG 3 OTHERS I 1 /4" TYPICAL MOUNTING NP' 1/4" SHUTTLE BY OTHERS :LF BRACKET DETAIL 3, DWG 3 TYPICAL LED DISPLAY SUPPORT DETAIL d SCALE: N.T.S. _ MBI COMPANIES INC. 299 N. VVEISGARBER RD. MBI KNOXVILLE, TN 37919 PHONE 865.584.0999 SIGN-ENGINEER.COM UPPER CATWAL BY OTHER SEE DETAIL W12x26 (30" LO LOWER CATWAL BY OTHER * CLIENT - AD GRAPHICS * 2020 FLORIDA BUILDING CODE 7TH ED. * RISK CATEGORY II * 160 MPH WIND SPEED, EXP. C * (1) POLE, (1) FOOTING SEE DETAIL 5, DWG 3 W10x12 UPRIGHT, TYP. 1 SEE DETAIL 4 375" WALL STEEL I uHtimN PIPE (50 KSI) TORSION TUBE/CATWALK SECTION „ SCALE: N.T.S. 18" 0 x 0.375" WALL STEEL TORSION PIPE (50 KSI) GUSSET DETAIL 6, DWG 3 PLATE TO PIPE 5/16" 5/16" TRANSITION CONNECTION DETAIL F SCALE: N.T.S. v PROJECT: MILE MARKER 135, 1-95, FORT PIERCE, FL DRAWING TITLE: 10'-6" x 36' DIGITAL BILLBOARD GUSSET TO PLATE GUSSET TO PIPE z w O PLATE TO PIPE NOTES 1.) SEE MANUFACTURERS DRAWINGS FOR ADDITIONAL DETAILS AND DIMENSIONS. 2.) SIGN CABINET AND CONNECTION BY AD GRAPHICS. I4X13, TYP. 2" 0 A325 BOLTS REQ'D. PER CONNECTION, TYP.) 110x12 UPRIGHT, TYP. LED DISPLAY BY OTHERS TYPICAL MOUNTING SHUTTLE BY OTHERS UPRIGHT CONNECTION DETAIL „ SCALE: N.T.S. v V 31-011 V TYPICAL TRANSITION MATCH PLATE (2 REQ'D.) SCALE: N.T.S. v DRAWN BY: I CHECKED BY: COMM. NO. DEW FCM 1 210231.001 CORP. LIC. # F02000002650 BUS. LIC. # AA26000828 ENG. C.O.A. # 29794 DATE: 03/04/21 DRAWING NO DWG. ^ L REV # DATE DRAWN BY 1 08/04/21 DEW REV #2 08/24/21 DSA 36"x36"xi " TRANSITION PLATE (2 REQ'D.) 24" 0 x 0.500" WALL STEEL PIPE (50 KSI) TORSION TUBE SHOWN FOR ORIENTATION GUSSET DETAIL 6, DWG 3 1 1 /8" 0 HOLE FOR 1" 0 A325 BOLT (12 PLCS.) 000s! 1" N S E T y g4O�oo b �00 °p0°OOp0O0 Vol, o �Qoa 4,GENse -.,r O O10 o No. 76813 0 O ° O * °p O D O 7y a STATE W 0 0 ° SO O ° °° °p°o0`°op Om.-ONA 4 P.E. LIC # 76813 5/8" 1 C C 4 1 /2"x4 1 /2"x3/8" PLATE 1 /2" 0 A325 BOLTS (2 REQ'D. PER CONNECTION, TYP.) C-C W10x12 UPRIGHT, TYP LOWER CATWALK SUPPORT DETAIL 1 SCALE: N.T.S. CALCULATIONS INCLUDE THE FOLLOWING CONSIDERATIONS AS OUTLINED IN THE 2020 FLORIDA BUILDING CODE (7th ED.) : CHAPTER 16-LOADS AND FORCES CHAPTER 17-SPECIAL INSPECTIONS CHAPTER 18- SOILS AND FOUNDATIONS CHAPTER19-CONCRETE CHAPTER 20-ALUMINUM CHAPTER 21-MASONRY CHAPTER 22-STEEL CHAPTER 23-WOOD *ALL SIGNS SHALL BE COMPLIANT WITH CURRENT NEC CODES* ao LO W10x12 UPRIGHT, TYP. - 1 /4" 1 /4" 11109 W12x26, TYP. 3/8" PLATE C-C 3"x3"x1/2"x5" LONG STEEL ANGLE 3/8" PLATE W10x12 UPRIGHT, TYP W12x26, TYP. 1/2" 0 A325 BOLTS (4 REQ'D. PER CONNECTION, TYP.) HORIZONTAL BEAM CONNECTION DETAIL SCALE: N.T.S. W 12x26 1/2" THICK WEB STIFFENING PLATE, TYP. LOWER BEAM CONNECTION DETAIL (SIDE VIEW) ,, SCALE: N.T.S. \.Toj MBI MBI COMPANIES INC. 299 N. VVEISGARBER RD. KNOXVILLE, TN 37919 PHONE 865.584.0999 SIGN-ENGINEER.COM NOTE: CUT HOLE IN SADDLE BEAM, SLEEVE TORSION TUBE THROUGH AND WELD ALL AROUND 3111 V-8" r- LO 8 1 /8" 1'-1 " �i� NOTES 1.) SEE MANUFACTURERS DRAWINGS FOR ADDITIONAL DETAILS AND DIMENSIONS. 2.) SIGN CABINET AND CONNECTION BY AD GRAPHICS. 5/8" THICK STEEL * CLIENT - AD GRAPHICS PLATE, TYP. * 2020 FLORIDA BUILDING CODE 7TH ED. * RISK CATEGORY II * 160 MPH WIND SPEED, EXP. C * (1) POLE, (1) FOOTING 4 1/2" TYR 5/8" THICK STEEL PLATE, TYP. O O 9/16" 0 HOLE '— `O FOR 1/2" 0 A325 BOLT Q (4 PLCS.) 3/16" TYPICAL SHELF BRACKET DETAIL SCALE: N.T.S. v 3/4"0 A325 BOLTS (8 REQ'D. PER CONNECTION, TYP.) TYP. 1/4" + � W12X26 (30" LONG) 114" 18" 0 x 0.375" WALL STEEL TORSION PIPE (42 KSI) SADDLE CONNECTION DETAIL SCALE: N.T.S. v PROJECT: MILE MARKER 135, 1-95, FORT PIERCE, FL DRAWING TITLE: 10'-6" x 36' DIGITAL BILLBOARD 3/8" CHAMFEI GUSSET DETAIL SCALE: N.T.S. v DRAWN BY: I CHECKED BY: COMM. NO. DEW FCM 1 210231.001 CORP. LIC. # F02000002650 BUS. LIC. # AA26000828 ENG. C.O.A. # 29794 GUSSET 25 7/16"x4"x3/4" SET 3/8"A " 1 1/2" CHAMP GUSSET DETAIL SCALE: N.T.S. DATE: 03/04/21 DRAWING NO DWG. 3 REV # DATE DRAWN BY 1 08/04/21 DEW REV #2 08/24/21 DSA co LO CV t M 0000ba"��N S E T y g4O�oo �b Q`.°°°GEN°°°�>`° QQa 4\ SF a!� o No. 76813 0 O O 0 * °° O D O 7y a STATE W 0 0 AI ° Oo � 4 O S °pAA°oo`°oo°° faCi b On _OIYA - P.E. LIC # 76813 GPI IC.P Nlr)TF.q- 1. THIS SPLICE CONNECTION IS A CRITICAL COMPONENT OF THE STRUCTURE. CARE SHOULD BE TAKEN IN FIT UP, WELDING, AND INSTALLATION 2. WELD = COLUMN WALL THICKNESS (U.N.O.) MINIMUM WELD SIZE IS DEPENDENT UPON THE THICKER OF THE TWO PARTS JOINED, EXCEPT THAT THE WELD SIZE NEED NOT EXCEED THE THICKNESS OF THE THINNER PART. FOR THIS EXCEPTION, PARTICULAR CARE SHALL BE TAKEN TO PROVIDE SUFFICIENT PREHEAT FOR SOUNDNESS OF THE WELD. 3. WELDING DESIGN, WORKMANSHIP, PROCEDURE AND TECHNIQUE SHALL CONFORM TO ALL APPLICABLE PROVISIONS OF THE AMERICAN WELDING SOCIETY STRUCTURE WELDING CODE STEEL, AWS D1.1. WELDERS SHALL BE QUALIFIED FOR THE PROCESS USED. TYPE AND SIZE OF WELD MUST BE INSTALLED AS SHOWN ON THE DRAWING. CONTRACTOR MUST SUPPLY, WHEN REQUESTED, CERTIFICATION OF PROCEDURE, QUALIFICATION OF WELDER AND DOCUMENT OF WELDING PROCEDURE. BOTH SHOP & FIELD WELDERS MUST PUNCH THEIR INITIAL & DATE ON CAP PLATE FOR IDENTIFICATION. 4. ALL SHOP WELDS SMAW OR GMAW (EXCEPT ELECTRODES OF 70,000 PSI TENSILE STRENGTH RATED AND APPROPRIATE WIRE DIAMETER SHALL BE USED FOR WELDING IN ALL POSITIONS. ALL FIELD WELDING SHALL BE SMAW WELDED USING ELECTRODES W/70,000 PSI TENSILE STRENGTH RATED FOR WELDING IN ALL POSITIONS. AWS A5.1 OR A5.5 E7018-132 OR APPROVED EQUAL. 5. COLUMN SURFACE NEAR WELDING AREA SHOULD BE CLEAN & DRY WHEN WELDING. SCRATCH IS NOT ALLOWABLE ON THE COLUMN SURFACE. GUSSET TO PIPE GUSSET TO PLATE NO WELD ON TOP 5/16" OF GUSSET GUSSETS (SEE SPLICE DETAIL TABLE) 1/2"- Al 0 z z � z o= Q Oo_ cf) w Q Q = J U a w w^^ U) z T INNER POLE J BOTTOM ONLY SEE CHART FOR T S WELD SIZE SPLICE DETAIL SCALE: N.T.S �7 NO WELD ON TOP OF PLATE. JOINT SHALL BE FREE OF GREASE AND OILS. PRIME AREA WITH SONNEBORN 733 PRIMER AND CAULK WITH NP1 ONE PART POLYURETHANE CAULK. FOLLOW MANUFACTURERS DIRECTIONS. 1" MIN. OUTER POLE 5/16 BOTTOM ONLY STEEL RING PLATES (SEE SPLICE DETAIL TABLE) 3-6 TYP. 1/4" V 3-6 EACH RING GUSSET DETAIL SCALE: N.T.S. T 211 TYP. NO WELD ON TOP BOTTOM WELD TO HAVE 2" GAPS BETWEEN WELDS � 1 SEE SLOT WELD CALCULATIONS INCLUDE THE FOLLOWING CONSIDERATIONS AS OUTLINED IN THE 2020 FLORIDA BUILDING CODE (7th ED.) : DETAIL CHAPTER 16-LOADS AND FORCES \ CHAPTER 17-SPECIAL INSPECTIONS CHAPTER 18- SOILS AND FOUNDATIONS CHAPTER 19-CONCRETE CHAPTER 20-ALUMINUM SEE SPLICE DETAIL CHAPTER 21-MASONRY H L TABLE CHAPTER 22-STEEL 60o CHAPTER 23-WOOD ALL SIGNS SHALL BE COMPLIANT WITH CURRENT NEC CODES* i PLAN VIEW SPLICE DETAIL TABLE UPPER STEEL SECTION MAX. WALL THICKNESS CAP PLATE THICKNESS RING PLATE THICKNESS MIN. RING PLATE SPACING NO. OF GUSSETS SIZE OF GUSSETS NO. OF SLOT WELDS/ PLT SIZE OF SLOT WELDS T S * H L <1 0" 3/8" 3/4" 3/4" 1811 4 3/8" 4 1/4" 5-6 5/8" 1 3/4" 12" - 18" 1 /2" 3/4" ill 27" 6 3/8" 6 5/16" 5-6 7/8" 2" 20" - 24" 1 /2" ill ill 36" 6 1 /2" 6 5/16" 11-12 7/8" 2 1 /4" 26" - 30" 3/4" ill 1 1/4" 45" 8 1 /2" 8 5/16" 11-12 ill 2 1 /2" 32" - 42" 3/4" 1 1 /2" 1 1/4" 63" 8 3/4" 8 5/16" 11-12 ill 3" 48" - 54" 3/4" 1 1 /2" 1 1/4" 84" 10 3/4" 10 3/8" 11-12 ill 3 1 /2" 60" - 66" 3/4" 2" 1 1/4" 102" 12 ill 12 3/8" 11-12 1 " 4" 72" - 96" ill 2" 1 1/4" 1 144" 1 16 1 ill 16 3/8" 11-12 1 1 /8" 4" MBI MBI COMPANIES INC. 299 N. WEISGARBER RD. KNOXVILLE, TN 37919 PHONE 865.584.0999 SIGN-ENGINEER.COM * 2" GAP BETWEEN WELDS REQUIRED PROJECT: MILE MARKER 135, 1-95, FORT PIERCE, FL DRAWING TITLE: 10'-6" x 36' DIGITAL BILLBOARD SCALE: N.T.S. 1 /8" MAX CLEARANCE RING PLATE w 0 STEEL SECTION NOTES 1.) SEE MANUFACTURERS DRAWINGS FOR ADDITIONAL DETAILS AND DIMENSIONS. 2.) SIGN CABINET AND CONNECTION BY AD GRAPHICS. * CLIENT - AD GRAPHICS * 2020 FLORIDA BUILDING CODE 7TH ED. * RISK CATEGORY II * 160 MPH WIND SPEED, EXP. C * (1) POLE, (1) FOOTING ii EQ. TYP. CAP PLATE (SEE TABLE) UPPER STEEL SECTION GUSSETS SIZE, QTY. (SEE SPLICE DETAIL TABLE) LOWER STEEL SECTION L RING PLATE SLOT WELD DETAIL 3 SCALE: N.T.S. DRAWN BY: I CHECKED BY: I COMM. NO. DEW FCM 210231.001 CORP. LIC. # F02000002650 BUS. LIC. # AA26000828 ENG. C.O.A. # 29794 DATE: 03/04/21 DRAWING NO DWG. REV # DATE DRAWN BY 1 08/04/21 DEW REV #2 08/24/21 DSA ob000! 1CN S E Tly b � O00000000°OA"/ ;Q�a ° 4�GENSF!°°!�` o No. 76813 0 O 0 0 O * 0 0 D O 7y a STATE W 0 0 0 O O 00 no °po�yoo`oo°f�\Ci Vb On - ONA L `\`` P.E. LIC # 76813 GROUND SIGN DESIGN SPECIFICATIONS: 1. REFER TO SIGN COMPANY'S DRAWINGS FOR MORE DETAILS. ALL DESIGNS, DETAILING FABRICATION AND CONSTRUCTION SHALL CONFORM TO: 2020 FLORIDA BUILDING CODE 7TH ED. ACI AISC AMERICAN WELDING SOCIETY LOCAL BUILDING CODES & ORDINANCES 2. CONCRETE: 2500 PSI @ 28 DAYS 3. STD. STEEL PIPE SECTION: ASTM A53 GRADE B (Fy=35 KSI), U.N.O. 4. STEEL PIPE SECTION (> 20" 0): ASTM A252 GRADE 3 (Fy=42 KSI MIN.) U.N.O. 5. HSS ROUND SECTION: ASTM A500 GRADE B (Fy=42 KSI) U.N.O. 6. HSS SQUARE/RECTANGULAR SECTION: ASTM A500 GRADE B (Fy=46 KSI) 7. W SHAPES: ASTM A992 (Fy = 50 KSI) 8. ANCHOR BOLTS: ASTM F1554 GRADE 36 U.N.O. (ALTERNATES GRADE 55 & 105) 9. CONNECTION BOLTS: ASTM A325 10. THREADED RODS: ASTM A193 GRADE B7 11. STEEL ANGLES, CHANNELS, STRUCTURAL SHAPES & PLATES ASTM A36 12. REINFORCING: GRADE 60 ASTM A615 13. PROVIDE A MINIMUM OF THREE INCHES OF CONCRETE COVER OVER EMBEDDED STEEL. 14. THE CONTRACTOR (INSTALLER) IS RESPONSIBLE FOR THE MEANS & METHODS OF CONSTRUCTION IN REGARDS TO JOBSITE SAFETY. 15. NO FIELD HEATING FOR BENDING OR CUTTING OF STEEL SHALL BE ALLOWED WITHOUT THE ENGINEER'S APPROVAL. 16. WELDING ELECTRODES: E70XX 17. ALLOWABLE SOIL BEARING PRESSURE ASSUMED: 2000 PSF 18. ASSUMED HORIZONTAL (PASSIVE PRESSURE) ASSUMED AT 150 PSF/FT OF DEPTH. ISOLATED LATERAL BEARING FOUNDATIONS FOR SIGNS NOT ADVERSELY AFFECTED A 1/2" MOTION AT THE GROUND SURFACE DUE TO SHORT TERM LATERAL LOADS SHALL BE PERMITTED TO BE DESIGNED USING TWO TIMES THE TABULATED CODE VALUES. 19. ALL FOOTINGS SHALL BEAR ON FIRM UNDISTURBED RESIDUAL SOIL AND/OR ENGINEERED EARTH. 20. FILL COMPACTED TO 98% OF ITS MAXIMUM DRY DENSITY AS PER ASTM D 698-70 (STANDARD PROCTOR) UNLESS NOTED OTHERWISE. THE SOIL BEARING CAPACITY IS TO BE VERIFIED BY A GEOTECHNICAL ENGINEER PRIOR TO CONSTRUCTION. IF ALLOWABLE BEARING AND/OR LATERAL PRESSURE IS LESS THAN THE ABOVE ASSUMED AND/OR CALCULATED PRESSURES, THE ENGINEER SHOULD BE CONTACTED FOR RE-EVALUATION. 21. EXCAVATION SHALL BE FREE OF LOOSE SOIL BEFORE POURING CONCRETE. 22. WELDERS SHALL BE CERTIFIED FOR THE TYPE OF WELDING. 23. ADEQUATELY BRACE POLE(S) UNTIL CONCRETE HAS SET UP FOR 14 DAYS. 24. GROUT UNDER BASE PLATES WITH NON -SHRINK GROUT. 25. THIS ENGINEER DOES NOT WARRANT THE ACCURACY OF DIMENSIONS FURNISHED BY OTHERS. 26. ALL EXPOSED STEEL SHALL BE PAINTED WITH AN ENAMEL PAINT TO INHIBIT CORROSION. 27. THIS DESIGN IS FOR THE INDICATED ADDRESS ONLY, AND SHOULD NOT BE USED AT OTHER LOCATIONS WITHOUT WRITTEN PERMISSION OF THE ENGINEER. 28. DESIGN OF DETAILS AND STRUCTURAL MEMBERS NOT SHOWN, BY OTHERS. MBI MBI COMPANIES INC. 299 N. WEISGARBER RD. KNOXVILLE, TN 37919 PHONE 865.584.0999 SIGN-ENGINEER.COM 1 C WIND DATA Building Code 2020 Florida Buildir Importance Factor, I Wind Load Criteria ASCE 7-16 Directionality Factor, Kd I2I Wind Speed,V 160 mph Topography Factor, K„ Exposure Category C Base Pressure, y(q,/K, Wind Pressure Override per 0 psf Jurisdiction Requirement GEOMETRY INPUT i'I Monument: No No. of Poles 1 No. of Footings 1 DEFLECTION ANALYSIS 1.0 Damping Ratio, (i 0.005 Deflection Limit H/60 0.85 Natural Frequency, n, 1.61 Hz IDef lection at 0.7*W 4.05 in 1.0 Gust Effect Factor, G 0.85 Deflection Ratio H/148 33.4 psf ASD Wind Load Factor, (3) 0.6 Notes: (1) Loading values in chart below are based upon average K, values for each segment. Actual values are calculated on hidden sheet using derived V-M equations. Chart is provided for information purposes only. (2) Wind directionality (K d) factor is 0.95 for Single Pole (Round) segments instead of 0.85. The C f value from Fig. 6-21 has been increased by 0.9510.85 to account for this variation. (3) Wind pressures listed below have already been multiplied by the ASD Wind Load Factor, V. Section Location Type j Height Width Horiz. Offset Area TopI Elev. Centroid K, G Wind Press. Support Pole Loads Footing Loads Trib. Factor Shear Moment Trib. Factor Shear Moment s s kips k- ki s k- 1 Base Singe Poe(Round) 35.00 4.00 140.0 35.0 17.5 1.01 0.78 22.6 1.0 3.2 55.3 1.0 3.2 55.3 2 Single Pole (Round) 4.50 3.00 13.5 39.5 37.3 1.04 0.78 23.1 1.0 0.3 11.6 1.0 0.3 11.6 3 Single Pole w/ Cabinet 10.50 36.00 378.0 50.0 44.8 1.09 1.81 56.3 1.0 21.3 953.0 1.0 21.3 953.0 4 None 0.0 50.0 50.0 1.09 1.46 45.4 0.0 0.0 0.0 0.0 0.0 0.0 5 None 0.0 50.0 50.0 1.09 1.46 45.4 0.0 0.0 0.0 0.0 0.0 0.0 6 None 0.0 50.0 50.0 1.09 1.46 45.4 0.0 0.0 0.0 0.0 0.0 0.0 7 None 0.0 50.0 50.0 1.09 1.46 45.4 0.0 0.0 0.0 0.0 0.0 0.0 8 None 0.0 50.0 50.0 1.09 1.46 45.4 0.0 0.0 0.0 0.0 0.0 0.0 9 None 0.0 50.0 50.0 1.09 1.46 45.4 0.0 0.0 0.01 0.0 10 Too None 0.0 50.0 50.0 1.09 1.46 45.4 0.0 0.0 0.0 1 0.0 0.0 1 0.0 Overall Height: 50.00 ft Summation based upon averages above: 24.8 1019.9 24.8 1019.9 Actual base reactions based upon V-M equations: 23.9 994.4 23.9 994.4 SUPPORT POLE DESIGN SUMMARY MATERIAL = STEEI Base Elev Section Axis Required Strength Values (ASD) Allowable Strength Values (ASD) Unity Ratios Interaction Ratios Status V, Mr T T, I P, I V, I M, I T, P� VJV, MdmM Tr/T� Pr/P� P-M P-M-V-T kips I kip- kip-kip-ft I kips I kips I ki - kip-kip-ft Iki s 0.00 36 x0.5 Wall Strong 23.9 994.4 152.3 11.7 436.1 1132.9 1159.8 653.6 5.5% 87.8% 13.1% 1.8% 89.6% 0.0% 35.00 24 m x 0.5 Wall Strong 21.1 204.5 150.0 5.5 288.8 532.7 508.7 812.3 7.3% 38.4% 29.5% 0.7% 39.1% 52.6% �✓/ 0.00 None Strong 23.9 994.4 152.3 11.7 0.0 0.0 0.0 0.0 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% �✓/ 0.00 None Strong 23.9 994.4 152.3 11.7 0.0 0.0 0.0 0.0 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.00 None Strong 23.9 994.4 152.3 11.7 0.0 0.0 0.0 0.0 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% �✓/ 0.00 None Strong 23.9 994.4 152.3 11.7 0.0 0.0 0.0 0.0 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% 0.00 None Strong 23.9 994.4 152.3 11.7 0.0 0.0 0.0 0.0 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% �✓/ 0.00 None Strong 23.9 994.4 152.3 11.1 0.0 0.0 0.0 0.0 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% �✓/ 0.00 None Strong 23.9 994.4 152.3 11.7 0.0 0.0 0.0 0.0 0.0% 0.0% 0.0% 0.0% 0.0% 0.0% �✓/ 0.00 None Strong 23.9 994.4 152.3 11.7 1 0.0 0.0 0.0 0.0 0.0% 0.0% 0.0% 0.0% 1 0.0% 0.0% d/ ELEMENT DESIGN LOCATIONS, LOADS AND DISPLACEMENTS Element Elev. Type V, M, Tr P, 0.7*0 0.7*b Element Elev. Type M, T, Pr 0.7*6 0.7*6 ki s ki - ki - ki s radians in kV,,'., ki - kip-kip-ft I kips I radians in 1 0.00 Base Plate 1 23.9 994.4 1 152.3 1 11.7 1 0.0 1 0.0 1 3 1 0.00 1 Match Plate 2 1 23.9 1 994.4 1 152.3 1 11.7 1 0.000 1 0.00 2 43.00 Match Plate 1 1 14.0 i 49.2 1 100.7 1 3.3 1 0.0 1 3.2 1 4 1 0.00 1 Torsion Tube 1 23.9 1 994.4 1 152.3 1 11.7 1 0.000 1 0.00 PLATE DESIGN SUMMARY Type Plate Dimensions Bolts Weld Status N B D t Number d^ NJedge Bedge Circle Diamete Material Embed in Caisson / Vertical Slab I Embed in Size k Gussets in in in in in in in in in I in in Rectangular Base Plate Circular Base Plate J Match Plate 1 (Lower) 36 36 -- 1 8 1 2.5 2.5 -- A325 -- -- 0.313 Yes OK J Match Plate 1 (Upper) 36 36 -- 1 8 1 2.5 2.5 -- A325 -- -- 0.313 No OK Match Plate 2 (Lower) Match Plate 2 (Upper) FOUNDATION DESIGN SUMMARY Type Diamete Width hicknes Length Depth VoLum a Reinforcing Status Caisson Vertical Slab J SpreadA -- I 18.50 -- 18.50 5.50 69.72 #8 at 12 in o.c. E.W. T&B OK PROJECT: MILE MARKER 135, 1-95, FORT PIERCE, FL DRAWING TITLE: 10'-6" x 36' DIGITAL BILLBOARD DRAWN BY: I CHECKED BY: I COMM. NO. DEW I FCM 1 210231.001 CORP. LIC. # F02000002650 BUS. LIC. # AA26000828 ENG. C.O.A. # 29794 DATE: 03/04/21 REV # DATE DRAWN BY 1 08/04/21 DEW REV #2 08/24/21 DSA NOTES 1.) SEE MANUFACTURERS DRAWINGS FOR ADDITIONAL DETAILS AND DIMENSIONS. 2.) SIGN CABINET AND CONNECTION BY AD GRAPHICS. * CLIENT - AD GRAPHICS * 2020 FLORIDA BUILDING CODE 7TH ED. * RISK CATEGORY II * 160 MPH WIND SPEED, EXP. C * (1) POLE, (1) FOOTING CALCULATIONS INCLUDE THE FOLLOWING CONSIDERATIONS AS OUTLINED IN THE 2020 FLORIDA BUILDING CODE (7th ED.) : CHAPTER 16-LOADS AND FORCES CHAPTER 17-SPECIAL INSPECTIONS CHAPTER 18- SOILS AND FOUNDATIONS CHAPTER19-CONCRETE CHAPTER 20-ALUMINUM CHAPTER 21-MASONRY CHAPTER 22-STEEL CHAPTER 23-WOOD *ALL SIGNS SHALL BE COMPLIANT WITH CURRENT NEC CODES* 00000a"��N S E T y g4O�oo Q`�°GEN°° °°°°°° °�>`��° QQa 4\ SF 0 4 o No. 76813 O a r� ° _ a ° * a 9 -0a a AE DRAWING NO. -;aa STATE W 4 O o DWG. �` p Az ° 4 5 % s°a a00000°°o ���fi M4 P.E. LIC # 76813