HomeMy WebLinkAboutGENERAL INFORMATION SECTION A T LUCK
Section A (General information)
Master Permit No.ONE CONSTRUCTION&ROOFING CONTRACTORS,INC Process No.
Contractors Name: Mauricio Orellana License# CCC-1330623
Job Address 5506 SUNSET BLVD. FORT PIERCE FL 34982
ROOF CATEGORY
M Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles
❑Asphaltic Shingles M Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair ❑ Maintenance ® Reroofing ❑Recovering
ROOF SYSTEM INFORMATION 2181 sq.ft.
Low Slope Roof Area(SF) 288 sq.fl. Steep Sloped Roof Area(SF) 1893 sq.ft. Total(SF)
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
z N
1S
ST. LUCIE WORKS
Section C(Low Slope Roof) Surfacing: N/A
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone 1':—" oc @ Lap,# Rows @ "oe
(If a component is not used,identify as"NA") Zone 1:_..._." oc @ Lap,# Rows @ "00
System Manufacturer: POLYGLASS USA
Zone 2:—" oc @Lap,# Rows @ "oc
Product Approval No.:
FL#1654-R27 Zone 3:_.._" oc @ Lap,#Rows @ °oc
Number of Fasteners Per Insulation Board:
Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3:
Zone 1':-36.1 Zone 1: -36.1 Zone 2: -47.7 Zone 3: -64.9 Illustrate Components Noted and Details as Applicable:
Max. Design Pressure, from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping,
system: Peel&stick/SBS-SA Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterf lashing,Coping,Etc.,
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: Plywood Flashing,Component Material, Material'Thickness,Fastener
19/32 Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: Comply with RAS 111 and Chapter 16..
Slope: 1/12"
Anchor/Base Sheet&No. df Ply(s): N/A
Anchor/Base Sheet Fastener/Bonding Material: FT.
N/A
Insulation Base Layer: N/A
Base Insultation Size and Thickness: N/A Parapet
Base Insulation Fastener/Bonding Material: Height
N/A
Top Insulation Layer: N/A
Top Insulation Size and Thickness: N/A 8'FROM F.F.E FT.
Top Insulation Fastener/Bonding Material:
N/A
Mean
Base Sheet(s)&No.of Ply(s): 1 Roof
Base Sheet Fastener/Bonding Material: Height
SELF-ADHERING
Ply Sheet(s)'&No.of Ply(s): N/A
Ply Sheet Fastener/Bonding Material:
N/A
Top Ply: 1
Top Ply Fastener/Bonding Material:
SELF-ADHERING
ST. LU IE
Section D (Steep Slope Roof System)
Roof system Manufacturer. Extreme Meta! fabricators, LLC
Notice of Acceptance Number:
FI# 17022-R8
Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations):
Zone 1:-38"1 Zone 2e: -50.2 Zone 2n:-50.2 Zone 2r:-49.6 Zone 3e:-50.2 Zone 3r: -50.2
Deck Type: 19/32 CDX Plywood
Type Underlayment: Owen cornings/Titanium Roof underlaymen, j
Roof Slope.
-�: 12 Insulation: N/A I
Fire Barrier: N/A
Ridge Ventilation? Fastener Type &Spacing: #;oaT is°FAS O CTENER WITH SEAL WASHER
N/A .
Adhesive Type: N/A
Type Cap Sheet: N/A
Mean Roof"Height: 12' Roof Covering: 5V metal roof/26 gauge
Type&Size Drip 2"x 2"/ Gal�valume,
Edge: