Loading...
HomeMy WebLinkAboutGENERAL INFORMATION SECTION A T LUCK Section A (General information) Master Permit No.ONE CONSTRUCTION&ROOFING CONTRACTORS,INC Process No. Contractors Name: Mauricio Orellana License# CCC-1330623 Job Address 5506 SUNSET BLVD. FORT PIERCE FL 34982 ROOF CATEGORY M Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles M Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance ® Reroofing ❑Recovering ROOF SYSTEM INFORMATION 2181 sq.ft. Low Slope Roof Area(SF) 288 sq.fl. Steep Sloped Roof Area(SF) 1893 sq.ft. Total(SF) Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. z N 1S ST. LUCIE WORKS Section C(Low Slope Roof) Surfacing: N/A Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: manufacturer Zone 1':—" oc @ Lap,# Rows @ "oe (If a component is not used,identify as"NA") Zone 1:_..._." oc @ Lap,# Rows @ "00 System Manufacturer: POLYGLASS USA Zone 2:—" oc @Lap,# Rows @ "oc Product Approval No.: FL#1654-R27 Zone 3:_.._" oc @ Lap,#Rows @ °oc Number of Fasteners Per Insulation Board: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Zone 1':-36.1 Zone 1: -36.1 Zone 2: -47.7 Zone 3: -64.9 Illustrate Components Noted and Details as Applicable: Max. Design Pressure, from the specific product approval Woodblocking, Gutter, Edge Termination, Stripping, system: Peel&stick/SBS-SA Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing,Coping,Etc., Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base Type: Plywood Flashing,Component Material, Material'Thickness,Fastener 19/32 Type,Fastener Spacing or Submit Manufacturers Details that Gauge Thickness: Comply with RAS 111 and Chapter 16.. Slope: 1/12" Anchor/Base Sheet&No. df Ply(s): N/A Anchor/Base Sheet Fastener/Bonding Material: FT. N/A Insulation Base Layer: N/A Base Insultation Size and Thickness: N/A Parapet Base Insulation Fastener/Bonding Material: Height N/A Top Insulation Layer: N/A Top Insulation Size and Thickness: N/A 8'FROM F.F.E FT. Top Insulation Fastener/Bonding Material: N/A Mean Base Sheet(s)&No.of Ply(s): 1 Roof Base Sheet Fastener/Bonding Material: Height SELF-ADHERING Ply Sheet(s)'&No.of Ply(s): N/A Ply Sheet Fastener/Bonding Material: N/A Top Ply: 1 Top Ply Fastener/Bonding Material: SELF-ADHERING ST. LU IE Section D (Steep Slope Roof System) Roof system Manufacturer. Extreme Meta! fabricators, LLC Notice of Acceptance Number: FI# 17022-R8 Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations): Zone 1:-38"1 Zone 2e: -50.2 Zone 2n:-50.2 Zone 2r:-49.6 Zone 3e:-50.2 Zone 3r: -50.2 Deck Type: 19/32 CDX Plywood Type Underlayment: Owen cornings/Titanium Roof underlaymen, j Roof Slope. -�: 12 Insulation: N/A I Fire Barrier: N/A Ridge Ventilation? Fastener Type &Spacing: #;oaT is°FAS O CTENER WITH SEAL WASHER N/A . Adhesive Type: N/A Type Cap Sheet: N/A Mean Roof"Height: 12' Roof Covering: 5V metal roof/26 gauge Type&Size Drip 2"x 2"/ Gal�valume, Edge: