Loading...
HomeMy WebLinkAboutEnergy Code."i FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Perfoanjg%6 Method Project Name: Lot 16 Block 2 Waterstone 2508 CGL Builder Name: ADAMS HOMES JUL 2 7 2021 Street: 8205 Amalfi Circle Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: St. Lucie County Owner: Jurisdiction: 661000 Permitting Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Typet2020.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1748.70 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 272.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= 5. Is this a worst case? No 11. Ceiling Types (2603.0 sgft.) ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 2523 a. Under Attic (Vented) b. Knee Wall (Vented) R=30.0 2523.00 ft2 R=19.0 80.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(293.4 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 166.06 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 503.2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 42.0 SEER:15.00 c. U-Factor: Dbl, U=0.55 35.56 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 6.223 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.288 a. Electric Heat Pump 42.0 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A 9. Floor Types (2523.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2 b. Conservation features EF: 0.940 b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Glass/Floor Area: 0.116 Total Proposed Modified Loads: 71.21 PASS Total Baseline Loads: 71.58 I hereby certify that the plans a cations covered Revie of the plans and ST9j this calculation are in compli i ergy specifications covered by this �'04 = O' Code. calculation indicates compliance with the Florida Energy Code. 04 PREPARED BY: Before construction is completed' DATE: 07-98-2091 XA1inn Kpnmany this building will be inspected for t�,, �. compliance with Section 553.908 ) I hereby certify that this building, as designed, is in compliance with the Florida EaaW Florida Statutes. ;S CodeG,OD.�y' .. OWNER/A BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house. 7/26/2021 3:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 4--ORM H kMalk AMARY CHECKU t Title: Lot 16 Block 2 Waterstone 25 Building Type: User Owner Name: # of Units: 1 Builder Name: ADAMS HOMES Permit Office: Jurisdiction: 661000 Family Type: Detached New/Existing: New (From Plans) Comment: PROJECT Bedrooms: 4 Conditioned Area: 2523 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No CLIMATE Address Type: Lot Information Lot # 16-2 Block/Subdivision: Waterstone PlatBook: Street: 8205 Amalfi Circle County: St. Lucie City, State, Zip: Fort Pierce , FL, 34951 / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2523 22202.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2523 222024 Yes 5 V 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0 2523 ft2 _--- 0.44 0 0.56 ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2821 ft2 630 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2523 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 2523 ft2 0.11 Wood 2 Knee Wall (Vented) Main 19 Batt 80 ft2 0.11 Wood 7/26/2021 3:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5 -FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS It Ornt Adjacent To WRI] T�gpe Space Cavity Width Height Sheathing Framing Solar Below 0 1 S Exterior Concrete Block - Int Insul Main 4.1 48 6 8 0 388.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Int Insul Main 4.1 37 2 8 0 297.3 ft2 0 0 0.6 0 3 N Exterior Concrete Block - Int Insul Main 4.1 51 3 8 0 410.0 ft2 0 0 0.6 0 4 NW Exterior Concrete Block - Int Insul Main 4.1 6 2 8 0 49.3 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Int Insul Main 4.1 37 6 8 0 300.0 ft2 0 0 0.6 0 6 - Garage Frame - Wood Main 13 34 0 8 0 272.0 ft2 0 0.23 0.01 0 7 W Exterior Concrete Block - Int Insul Main 4.1 23 6 8 0 188.0 ft2 0 0 0.6 0 8 S Exterior Concrete Block - Int Insul Main 4.1 8 6 8 0 68.0 ft2 0 0 0.6 0 9 N Exterior Concrete Block - Int Insul Main 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated Main None .25 3 6 8 20 ft2 2 Wood Main None .25 2 8 6 8 17.8 ft2 3 N Insulated Main None .25 2 4 6 8 15.6 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 25 ft 0 in 0 ft 10 in Drapes/blinds None 2 S 1 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 3 E 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.5 ft2 13 ft 0 in 0 ft 6 in None None 4 E 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 13 ft 0 in 2 ft 10 in None None 5 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 7 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 6 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 4 in 2 ft 0 in Drapes/blinds Exterior 5 7 N 3 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 8 N 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 9 NW 4 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 7 ft 2 in 0 ft 4 in Drapes/blinds Exterior 5 10 W 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 10 in 0 ft 10 in Drapes/blinds None 11 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft2 7 ft 2 in 0 ft 4 in Drapes/blinds Exterior 5 12 W 7 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 10 in 0 ft 4 in Drapes/blinds Exterior 5 13 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 620 ft2 620 ft2 64 ft 8 ft 1 7/26/2021 3:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 2590.3 142.11 266.8 .1312 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 42 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 42 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 503.2 ft Main 125.8 ft Proposed Qn Main --- cfm 151.4 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling H Jan Feb Mar Heating Jan Feb Mar Apr APr Se MayJun Jul f AuSep Ma rl Jun rl Jul Augri Oct Nov Oct Nov Dec Dec Venting Jan Feb X Mar [X] Apr [ May JunJul[ Aug Se [X] O[XI Nov Dec 7/26/2021 3:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 ,FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT r Thermostat Schedule: Schedule Type HERS 2006 Reference 1 2 3 4 5 6 Hours 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 68 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main 7/26/2021 3:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5 a FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 8205 Amalfi Circle, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1748.70 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 272.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2523.00 ft2 6. Conditioned floor area (ft2) 2523 b. Knee Wall (Vented) R=19.0 80.00 ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 166.06 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 503.2 b. U-Factor: Dbl, U=0.33 70.92 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency C. U-Factor: Dbl, U=0.55 35.56 ft2 a. Central Unit 42.0 SEER:15.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 20.83 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 6.223 ft. a. Electric Heat Pump 42.0 HSPF:8.50 Area Weighted Average SHGC: 0.288 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 9. Floor Types Insulation Area b. Conservation features a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2 None b. N/A R= ft2 Credits (Performance method) Pstat c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature- Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/26/2021 3:23 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1