HomeMy WebLinkAboutEnergy Code."i
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Perfoanjg%6 Method
Project Name: Lot 16 Block 2 Waterstone 2508 CGL
Builder Name: ADAMS HOMES
JUL 2 7 2021
Street: 8205 Amalfi Circle
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
St. Lucie County
Owner:
Jurisdiction: 661000
Permitting
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Typet2020.7 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1748.70 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 272.00 ft2
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R=
5. Is this a worst case? No
11. Ceiling Types (2603.0 sgft.)
ft2
Insulation Area
6. Conditioned floor area above grade (ft2) 2523
a. Under Attic (Vented)
b. Knee Wall (Vented)
R=30.0 2523.00 ft2
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(293.4 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33 166.06 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
42.0 SEER:15.00
c. U-Factor: Dbl, U=0.55 35.56 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 6.223 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.288
a. Electric Heat Pump
42.0 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
9. Floor Types (2523.0 sgft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2
b. Conservation features
EF: 0.940
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.116 Total Proposed Modified Loads: 71.21
PASS
Total Baseline
Loads: 71.58
I hereby certify that the plans a cations covered
Revie of the plans and
ST9j
this calculation are in compli i ergy
specifications covered by this
�'04 = O'
Code.
calculation indicates compliance
with the Florida Energy Code.
04
PREPARED BY:
Before construction is completed'
DATE: 07-98-2091 XA1inn Kpnmany
this building will be inspected for
t�,, �.
compliance with Section 553.908
)
I hereby certify that this building, as designed, is in compliance
with the Florida EaaW
Florida Statutes.
;S
CodeG,OD.�y'
..
OWNER/A
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house.
7/26/2021 3:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
4--ORM
H kMalk
AMARY CHECKU
t
Title:
Lot 16 Block 2 Waterstone 25
Building Type:
User
Owner Name:
# of Units:
1
Builder Name:
ADAMS HOMES
Permit Office:
Jurisdiction:
661000
Family Type:
Detached
New/Existing:
New (From Plans)
Comment:
PROJECT
Bedrooms:
4
Conditioned Area:
2523
Total Stories:
1
Worst Case:
No
Rotate Angle:
0
Cross Ventilation:
No
Whole House Fan:
No
CLIMATE
Address Type: Lot Information
Lot #
16-2
Block/Subdivision:
Waterstone
PlatBook:
Street:
8205 Amalfi Circle
County:
St. Lucie
City, State, Zip:
Fort Pierce ,
FL, 34951
/ Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium
BLOCKS
Number Name Area Volume
1 Blockl 2523 22202.4
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 2523 222024 Yes 5
V
4
1
Yes
Yes Yes
FLOORS
# Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main
208.9 ft 0
2523 ft2
_---
0.44 0 0.56
ROOF
Roof Gable Roof
Red
Solar
SA Emitt
Emitt Deck Pitch
# Type Materials
Area Area Color
Barr
Absor.
Tested
Tested Insul. (deg)
1 Gable or Shed Composition shingles
2821 ft2 630 ft2 Medium
N
0.85
N 0.85
No 0 26.57
ATTIC
# Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
300 2523 ft2
N
N
CEILING
# Ceiling Type
Space R-Value Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
Main 30 Blown
2523 ft2
0.11
Wood
2 Knee Wall (Vented)
Main 19 Batt
80 ft2
0.11
Wood
7/26/2021 3:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
Page 2 of 5
-FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
It Ornt
Adjacent
To WRI] T�gpe
Space
Cavity Width
Height
Sheathing Framing Solar Below
0
1 S
Exterior
Concrete Block - Int Insul
Main
4.1 48
6
8 0
388.0 ft2
0
0 0.6
0
2 E
Exterior
Concrete Block - Int Insul
Main
4.1 37
2
8 0
297.3 ft2
0
0 0.6
0
3 N
Exterior
Concrete Block - Int Insul
Main
4.1 51
3
8 0
410.0 ft2
0
0 0.6
0
4 NW
Exterior
Concrete Block - Int Insul
Main
4.1 6
2
8 0
49.3 ft2
0
0 0.6
0
5 W
Exterior
Concrete Block - Int Insul
Main
4.1 37
6
8 0
300.0 ft2
0
0 0.6
0
6 -
Garage
Frame - Wood
Main
13 34
0
8 0
272.0 ft2
0
0.23 0.01
0
7 W
Exterior
Concrete Block - Int Insul
Main
4.1 23
6
8 0
188.0 ft2
0
0 0.6
0
8 S
Exterior
Concrete Block - Int Insul
Main
4.1 8
6
8 0
68.0 ft2
0
0 0.6
0
9 N
Exterior
Concrete Block - Int Insul
Main
4.1 6
0
8 0
48.0 ft2
0
0 0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
W
Insulated Main
None
.25
3
6 8
20 ft2
2
Wood Main
None
.25
2
8
6 8
17.8 ft2
3
N
Insulated Main
None
.25
2
4
6 8
15.6 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
# Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 S
1
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
25 ft 0 in
0 ft 10 in
Drapes/blinds
None
2 S
1
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3 E
2
Vinyl Low-E Double
Yes
0.33 0.31
N
7.5 ft2
13 ft 0 in
0 ft 6 in
None
None
4 E
2
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft2
13 ft 0 in
2 ft 10 in
None
None
5 E
2
Vinyl Low-E Double
Yes
0.33 0.21
N
32.4 ft2
7 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
6 E
2
Vinyl Low-E Double
Yes
0.33 0.21
N
38.5 ft2
1 ft 4 in
2 ft 0 in
Drapes/blinds
Exterior 5
7 N
3
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8 N
3
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
9 NW
4
Vinyl Low-E Double
Yes
0.33 0.23
N
12.5 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
10 W
5
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
9 ft 10 in
0 ft 10 in
Drapes/blinds
None
11 W
5
Vinyl Low-E Double
Yes
0.33 0.23
N
16.7 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
12 W
7
Vinyl Low-E Double
Yes
0.33 0.23
N
30.0 ft2
9 ft 10 in
0 ft 4 in
Drapes/blinds
Exterior 5
13 W
5
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
620 ft2 620 ft2
64 ft
8 ft
1
7/26/2021 3:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000391
2590.3 142.11 266.8 .1312
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
---- Supply ----
---- Return --- Air CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type Handler TOT OUT
QN RLF
Heat Cool
1 Attic 6 503.2 ft
Main
125.8 ft Proposed Qn Main --- cfm 151.4 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling H Jan Feb Mar
Heating Jan Feb Mar
Apr
APr
Se
MayJun Jul f AuSep
Ma rl Jun rl
Jul Augri
Oct Nov
Oct Nov
Dec
Dec
Venting Jan Feb X Mar
[X] Apr [
May JunJul[ Aug Se [X]
O[XI Nov
Dec
7/26/2021 3:23 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
,FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
r
Thermostat Schedule:
Schedule Type
HERS 2006 Reference
1
2
3
4
5
6
Hours
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
7/26/2021 3:23 PM
EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software
Page 5 of 5
a FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
8205 Amalfi Circle, Fort Pierce, FL, 34951
1. New construction or existing New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1748.70 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0
272.00 ft2
c. N/A
R=
ft2
4. Number of Bedrooms 4
d. N/A
R=
ft2
5. Is this a worst case? No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2523.00 ft2
6. Conditioned floor area (ft2) 2523
b. Knee Wall (Vented)
R=19.0
80.00 ft2
7. Windows- Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
166.06 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
b. U-Factor: Dbl, U=0.33
70.92 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
C. U-Factor: Dbl, U=0.55
35.56 ft2
a. Central Unit
42.0 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: other (see details)
20.83 ft2
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
6.223 ft.
a. Electric Heat Pump
42.0
HSPF:8.50
Area Weighted Average SHGC:
0.288
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
9. Floor Types Insulation
Area
b. Conservation features
a. Slab -On -Grade Edge Insulation R=0.0
2523.00 ft2
None
b. N/A R=
ft2
Credits (Performance method)
Pstat
c. N/A R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature- Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/26/2021 3:23 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1