Loading...
HomeMy WebLinkAboutProduct Approval; Swinging Exterior Door AssembliesBCIS Home Log In User Registration Hot Topics Submit Surcharge I Stets & Facts Publications Contact Us i BCIS Site Map Links Search DrA°f Product Approval USER: Public User Md ct A proval Menu > Product or Aapilcatlon Search > APpllcatlon List > Application Detall C"' �'�=-+iA%,•.,-� FL # FL17996-112 Application Type Revision 6 Code Version 2020 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Elixir Door and Metal Company Address/Phone/Email 1215 Pope Drive Douglas, GA 31533 (912)493-2215 ryarberry@elixirdmc.com Authorized Signature Randall Yarberry ryarberry@elixlrdmc.com Technical Representative PTC Product Design Group Address/Phone/Email PO Box 520775 Longwood, FL 32752 (321)690-1788 Info@ptc-corp.com Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory Swinging Exterior Door Assemblies Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By American Architectural Manufacturers Association Referenced Standard and Year (of Standard) Standard Year ASTM E330 2002 ASTM E330 2014 Equivalence of Product Standards Certified By Product Approval Method Florida Licensed Professional Engineer or Architect FL17996 R2 Eauiv EER 2244 Rev- ss.Ddf Method 1 Option A Date Submitted 02/19/2021 Date Validated 02/22/2021 Date Pending FBC Approval Date Approved 02/28/2021 Summary of Products . FL # Model, Number or Name Description 17996.1 Series 202-20S Steel Door Series 202-20S Steel O.S. Door w/ Vertical Slider Window Limits of Use Approved for use in HVHZ: No Approved for use out§lde HVHZ: Yes Impact Resistant: No Design Pressure: +38.7/-32 Other: Certification Agency Certificate FL17996 R2 C CAC 19359 Elixir - 202-20S OS Door (lib , ASTM ]an. 2021.odd Quality Assurance Contract Expiration Date 07/11/2024 Installation Instructions FL17996 R2 It ELIX0034 Rev B Model 202 20S ss od Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1642 Rev4 ss.odf Created by Independent Third Party: Yes 17996.2 Series 230 W9 Steel Door Series 230 W9 Steel O.S. Door w/ Cottage Window Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Certification Agency Certificate FL17996 R2 C CAC 19346 Elixir - 230-W9 OS Door jbI ASTM ]an. 2021.ndf Impact Resistant: No Design Pressure: +25.3/-25.3 Other: Quality Assurance Contract Expiration Date 07/11/2024 Installation Instructions FL17996 R2 II ELIX0033 Rev B Model 230 W9 ss,ndf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1642 Rev4 ss.pddF Created by Independent Third Party: Yes 17996.3 Series 402-14 Vinyl Steel Out -Swinging Regular Door - 14" x 14" Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL17996 R2 C CAC 19349 Elixir - 402-14 OS Door ASTM ]an. 2021.pdf Impact Resistant: No Design Pressure: +66/-56 Quality Assurance Contract Expiration Date 08/26/2025 Other: Installation Instructions FL17996 R2 11 ELIX0050 REV-8 OS MODEL 402-14 ss odf Verifled By: Robert ]. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1951 Rev3 ss.odF Created by Independent Third Party: Yes 17996.4 Series 402-20S Vinyl Steel Out -swinging Regular Door - 20" slider window Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL17996 R2 C CAC 19358 Elixir - 402-20S OS Door {, ASTM ]an. 2021.pdf Impact Resistant: No Design Pressure: +66/-56 Quality Assurance Contract Expiration Date 08/26/2025 Other: Installation Instructions FL17996 R2 II ELIX0051 REV-5 OS MODEL 402-20S ss,pdf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1951 Rev3 ss.odf ���-yjngppendent Third Party: Yes 17996.5 Series 407 Vinyl Steel Out -Swing Regular Door - Blank (no window) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No Approved for use outside HVHZ: Yes FL17996 R2 C CAC 19345 Elixir - 407 OS Door (1b) ASTM ,Jan. 2021.pdf Impact Resistant: No Design Pressure: +50/-50 Quality Assurance Contract Expiration Date 08/19/2025 Other: Installation Instructions FL17996 R2 11 EUX0052 REV-B OS MODEL 407 ss.od Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports Created by Independent Third Party: Yes Created R2 AE PER 1951 Rev3 s: Yes 17996.6 Series 430 W9 Vinyl Steel Out -swinging Regular Door - 9-1.1te Window (1'8" x 3-0") Limits of Use Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Certification Agency Certificate FL17996 R2 C CAC 19344 Elixir 430 W9 OS Door (1b) ASTM Jan, 2021.odf Quality Assurance Contract Expiration Date 08/25/2025 Installation Instructions FL17996 R2 II ELIX0053 REV-B OS MODEL 430-W9ss odf Verified By: Roberti. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1951'Rev3 ss odf' Created by Independent Third Party: Yes 17996.7 Series 6400 W9 Cottage Series 6400-W9 Non -Impact Inswing Painted Steel Door w/Storm Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +66.7/-56.7 Other: Certification Agency Certificate FL17996 R2 C CAC 19352 Elixir 6400 W9 IS Door w Storm (t.b). ASTM Jan. 2021_.®df Quality Assurance Contract Expiration Date 09/07/2024 Installation Instructions FL17996 R2 II ELIX0056 Rev-8 IS MODEL 6400-W9 WITH STORM DOOR ssodf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R7_ AE PcR 1954 Rev3 ss odf Created by Independent Third Party: Yes 17996.8 Series 7500 Oval Series 7500 Non -Impact Inswing Vinyl Laminated Steel Door w/Storm Door and PVC Jambs Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Certification Agency Certificate FL17996 R2 C CAC 19348 Elixir - 7500 IS Door w-Storm (ib) ASTM Jan. 2021.adf Quality Assurance Contract Expiration Date 08/23/2024 Installation Instructions FL17996 RZ II ELTX0060 Rev-B IS MODEL 57R 7500 OVAL WITH STORM DOOR ssodf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1955 Rev3 ss pdf Created by Independent Third Party: Yes 17996.9 Series 8400 W9 Cottage Series 8400-W9 Non -Impact Oval Inswing Vinyl Laminated Steel Door w/Storm Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: Certification Agency Certificate FL17996 R2 C CAC 19353 Elixir - 8400-W9 IS Door w-Storm lb ASTM Jan. 2021.odf Quality Assurance Contract Expiration Date 09/07/2024 Installation Instructions FL17996 R2 II ELTX0057 Rev-B IS MODEL 8400 W9 OVA WITH STORM DOOR ss.odf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1954 Rev3 ssodf Created by Independent Third Party: Yes 17996.10 Series 9000 Series 9000 Non -Impact Inswing Vinyl Laminated Steel Door w/Storm Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50.7 Other: Certification Agency Certificate FL17996 R2 C CAC 19374 Elixir - 9000 IS Door w-Storm (1b) ASTM Jan. 2021.ndf Quality Assurance Contract Expiration Date 09/06/2024 Installation Instructions FL17996 R2 II ELIX0058 Rev-B IS BLANK 9000 DOOR W. STORM DOOR ssodf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1954 Rev3 ss odf Created by Independent Third Party: Yes 17996.11 Series 9400-W9 Cottage Series 9400-W9 Non -Impact Inswing Vinyl Laminated Steel Door w/Storm Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes' 'Impact Resistant: No Design Pressure: +50/-50 Other; Certification Agency Certificate FL17996 RZ C CAC 19350 Elixir - 9400-W9 IS Door w-Storm 1b ASTM Jan. 2021.odf Quality Assurance Contract Expiration Date 09/06/2024 Installation Instructions FL17996 R2 II ELIX0059 Rev-B IS MODEL 9400-W9 COTTAGE W, STORM DOOR ss.odf Verified By: Robert J. Amoruso, PE FL PE No, 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1954 Rev3 ss.odf Created by Independent Third Party: Yes 17996.12 Series AFIF7N Series AFIF7N Non -Impact IS Fiberglass Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +38.7/-38.7 Other: Certification Agency Certificate FL17996 RZ C CAC 19351 Elixir - AFIM IS Door (1h) SA TM Jan. 2021.odf Quality Assurance Contract Expiration Date 08/21/2024 Installation Instructions FL17996 R2 II EM0040 AFIF7N-13F1F7N RevB ss,pdf Verified By: Robert 3. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1952 Rev3 ss.pdf Created by Independent Third Party: Yes 17996.13 Series AVIF7N Series AVIF7N Non -Impact IS Steel Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +38/-38 Other: Certification Agency Certificate FI-17996 R2 C CAC 19356 Elixir - AVIF7N IS Door (1b) ASTM Jan. 2021.odf Quality Assurance Contract Expiration Date 07/22/2025 Installation Instructions FL17996 R2 IT ELIX0047 AVIF7N RevB ss pdf Verfed By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1953 Rev3 ss odf Created by Independent Third Party: Yes 17996.14 Series BFIF7N Series BFIF7N Non -Impact IS Fiberglass Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +38.7/-38.7 Other: Certification Agency Certificate FL17996 R2 C CAC 193S7 Elixir - BFIF7N IS Door w-Side Utes f 1b _ASTM Jan. 2021.odf Quality Assurance Contract Expiration Date 08/21/2024 Installation Instructions FL17996 R2 II ELIX9040 AFIF7N-BFIF7N RevB ss adf Verified By: Robert J. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 RZ AE PER 1952 Rev3 ss gdf Created by Independent Third Party: Yes 17996.15 Series BVI63S Series BVI63S Non -Impact Single Inswing Door w/Fixed Lite Insert and Outswing Storm Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +65/-65 Other: Certification Agency Certificate FL17996 R2 C CAC EXR BVI63S E330 olus5.odf Quality Assurance Contract Expiration Date 12/17/2021 Installation Instructions FL17996 R2 H ELIX0061 BV1635 RevB ss.odf Verified By: Roberti. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 2244 Rev3 ss odf Created by Independent Third Party: Yes 17996.16 Series BVIF7N Series BVIF7N Non -Impact IS Steel Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: . Certification Agency Certificate FL17996 R2 C CAC 19354 Elixir - BVIF7N IS Door (1b) ASTM Jan. 2021.odF Quality Assurance Contract Expiration Date 07/29/2025 Installation Instructions EL17996 R2 II EUX0049 BVIF7N BVIF7S RevB ss odf Verified By: Roberti. Amoruso, PE FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1953 Rev3 ss,pdf Created by Independent Third Party: Yes 17996.17 I Series BVIF7S I Series BVIF7S Non -Impact IS Steel Door Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +5o/-50 Other: Certification Agency Certificate FL17996 R2 C CAC 19355 Elixir - BVIF7S IS Door w-Storm ASTM Jan. 2021.Ddf Quality Assurance. Contract Expiration Date 07/29/2025 Installation Instructions FL17996 R2 II ELIX0049 BVIF7N BVIF7S RevB ss odf Verified By: Robert J. Amoruso, PE FL PE No. 49752 ^ Created by Independent Third Party: Yes Evaluation Reports FL17996 R2 AE PER 1953 Rev3 ss.Ddf Created by Independent Third Party: Yes Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer, Coopvriaht 2007-2013 State of Florida.:: Privacy Statement :: AccesslblON Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850AS7.1395. -Pursuant to Section 45S.27S(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for ofRdal communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 4S5, F.S., please dick here . Product Approval Accepts. o��._t Credit Card Safe ELIXIR DOOR & METALS CO. I 1 19 G MODEL 407 NON -IMPACT OUTSWING m ' a VINYL LAMINATED STEEL DOOR a 3 Z INSTALLATION ANCHORAGE DRAWING r. GENERAL NOTES; 1. THE PRODUCT ANCHORAGE SHOWN HEREIN IS DESIGNED S.IN AREAS WHERE WINOBORNE DEBRIS PROTECTION TO COMPLY WITH THE CURRENT EDITION OF THE REQUIREMENTS EXIST, USE OFAN IMPACT PROTECTIVE FLORIDA BUILDING CODE (FBC) EXCLUDING HIGH SYSTEM COMPLYING WITH THE FBC REQUIREMENTS FOR VELOCITY HURRICANE ZONE AND THE DESIGN WINDBORNE DEBRIS REGIONS IS MANDATORY FOR THE PRESSURE(S) STATED HERON. PRODUCT HEREIN. 1a. THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED 6. FRAME MATERIAL, ALUMINUM ALLOY 6063•TO UPON SIGNED AND SEALED TEST REPORT DOOR PANEL MATERIAL:.09 MR VINYL LAMINATED CONSTRUCTION CONSULTING LABORATORY REPORT# GALVANIZED STEEL015' SKIN W/ URETHANE FOAM CORE CCL.19.187 AND ASSOCIATED LABORATORY STAMPED DRAWINGS, 7. GLASS MEETS THE REQUIREMENTS OF ASTM E1300.12AE1. Ib, TESTED TO ASTM E33044. 2. ADEQUACY OF THE EXISTING STRUCTURAL. 2X FRAMING OR STEM FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER ORARCHITECTOF RECORD. 8. DESIGNATIONS'X' STAND FOR THE FOLLOWING: X: OPERABLE PANEL 0:FIXED PANEL 9. HARDWARE: A HALF HINGES: (4) BOBS -TO EXTRUDED ALUMINUM B. LATCH LOCK KEYED C. DEAD BOLT. SINGLE CYLINDER 3. IX AND 2X SUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE 10. SEE SHEET1 FOR DESIGN PRESSURE CHART. STRUCTURE BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF 11. IF WATER INFILTRATION REQUIREMENT EXISTS, UNIT MUST RECORD. BE INSTALLED BENEATH AN OVERHANG MEETING THE 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FORA SPECIFIC SITE, IFSITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. CURRENT EDITION OF THE FLORIDA BUILDING CODE - BUILDING AND RESIDENTIAL VOLUMES. DESIGN PRESSURE RATING (PSF) IMPACT RATING WHERE WATER INFILTRATION REQUIREMENT IS NEEDED WHERE WATER INFILTRATION REQUIREMENT IS NOT NEEDED NONE SEE GENERAL NOTE 11 +50 / •50 TABLE OF CONTENT SHEET DESCRIPTION 1 GENERAL AND INSTALLATION NOTES 2 ELEVATION, ANCHORING LAYOUT 3 VERTICAL CROSS SECTIONS 4 HORIZONTAL CROSS SECTIONS INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION. 2. THE INSTALLATION ANCHORS ATTHE SPACINGS SHOWN ARE THE MINIMUM NUMBER OFANCHORS AND MAXIMUM SPACINGS TO BE USED FOR PRODUCT INSTALLATION. 3. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM SIZE OF 1141NCH. SHIM WHERE SPACE OF 1/181NCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER• 4. ANCHORS FOR INSTALLATION INTO WOOD FRAMING OR 14GA. MINIMUM STEEL FRAMING SHALL BE AS SHOWN IN 'ANCHOR SCHEDULE' THIS SHEET. 5. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE I C) WALL FINISHES, INCLUDING BUT NOT LIMBED TO t, STUCCO, FOAM, BRICK VENEER AND SIDING 6. INSTALLATION ANCHORS SHALL BE INSTALLED IN a ACCORDANCE WTTH ANCHOR MANUFACTURERS INSTALLATION INSTRUCTIONS 'Q+ m AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS C—� 03 THAN THE MINIMUM STRENGTH SPECIFIED IN THE W�.7 'ANCHORSCHEOULE'THISSHEET. F-, a o 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING, p D. 0 CV Q 0 a X a w ANCHOR SCHEDULE SUBSTRATE DOORFRAME TYPE SIZE MANUFACTURER ANDIOR EMBEDMENT EDGE EDGE ANCHOR CAPACITIES TYPE SPECIFICATION (IN) 01 (IN) (1) (A BASED ON SHEET MIN. 3 METAL/STEEL THREADS TUBING 14 GA FIN (Z•BAR) PAN HEAD NO. B ASNE B18,s,4 PAST INSIDE 3/8, MIN, 33 KSI YIELD MIN• (TAPPING SCREW) SURFACE OF STRNEGTH THICKNESS I SUBSTRATE ANSI 818.6.1 2X WOOD (WOOD SCREM WOOD WITH A MJNIMUM FRAMING FIN (Z•BAR) PAN HEAD NO.8 OR 1' 12' SPECIFIC GRAVITYOP ASME B18.6.4 OA2. (TAPPING SCREW) NOTES: 1) FOR WOOD OR TAPPNG SCREWS IF SPITTING IS A C(INCERR DRILL 0.082' PLOT HOLE(DRLL SQE45). 2) EDGE DISTANCE MEASURED FROM ETHER SIDE OF A ICHORTO EDGEOFSUBSTRATE 2 60 60 0 UW o. 20 I� Z O Z� O a. Robert J. Arnoluso, P.E, FL P.E. No.49752 ...... ' Digitally signed by RobertJ Amoruso Date., 2021.02.18 12:08.03-05100' 38 P MAX. OA FRAME WIDTH 36' MAX. DOOR PANEL WIDTH 6' MAX. O.C. (TYP.) B D 4' MAX (TYP.) 4' MAX. (1 YP.) 3 3 H 3' MAX. (TYP.) G X IGwA LOCK ASSEMBLY IS LOCATED APPROX. W MAX. 02114' 80' 4 4 3T ABOVE BOTTOM OF DOOR LEAF O.C. (TYP.) MAX.OA MAX E O AND THE DEAD BOLT ASSEMBLY DO FRAME DOOR 4 4 APPROX.41'ABOVEBOTTOM OF DOORHEIGHT PANEL OT LEAF. SEE STRIKE DETAILS THIS HEIGHT 1 SHEET. 41' 3I I 1 r 3' MAX (TYP.) FOUR HALF HINGES, 3' AND 21' FROM EACH A C END OF THE DOOR 3 3 PANELSECURED BY #6 X 314' SCREWS (TYP'.) EXTERIOR VIEW SIB x 318' WOOD SCREW I I l J ENTRY DOOR STRIKE DETAIL WOOD eeWESUMMA7s I 1 SIB TAPPING SCREW. SCREW MUST BE OF SUFFICIENT LENGTH TO PENETRATE(3)THREADS I MINIMUM BEYOND STEEL TUBE. ENTRY DOOR STRIKE DETAIL STEELTnme:OSUeMATE SILL ANCHOR SPACING SAME AS HEAD SPACING ANCHOR LAYOUT EXTERIOR VIEW ANCHORING NOTES: 1. MINIMUM NUMBER OF ANCHORS IN JAMBS IS 14. ANCHOR SPACING VARIES, BUT NOT TO EXCEED a - MAXIMUM O.C. 2. MINIMUM NUMBER OF ANCHORS IN HEAD AND SILL IS 6. ANCHOR SPACING VARIES, BUT NOT TO EXCEED W MAXIMUM O.C. L-J Robert J. Amonuo. P.E. FL P.E. No. 49752 Digitally signed by Robert J E o "* - ;-N Amoruso v G Date: 2021.02.18 12.08,47 -05'00' 1' MIN. EMBEDMENT #8 WOODSCREW r INSTALLATION ANCHOR 2X WOOD FRAMIfLINTERIOSR a (BY OTHER1/2' MIN THREE (3) THREAD M 0 cl I SEALANT TAPE TO BACKEDGE DIST. MIN. PENETRATION #8 TAPPING SCREW SIDE OF MOUNTING FIN INSTALLATION ANCHOR a+ SEALANT TAPE TO BACK 318' MIN. ° Z SIDE OF MOUNTING FIN EDGE DIST. 1/4' MAX SHIM m EXTERIOR 14 GA. MIN. SQUARE STEEL TUBING (BY 0 N a OTHERS) V c lm N X 0 EXTERIOR INTERIOR a 2 go: eq M # E I H m 'ooa VERTICAL SECTION e i W �-: in D WOOD FRAME SUBSTRATE !//r��� S�TEELIUBINGSUBSTRAa o v -d aav� Z L --0 Zi,, - b IL O IS `^ F 11� O A c � �z� n �r� os X 0 a'pl a W EXTERIOR INTERIOR EXTERIOR INTERIOR MAX SHIM 14 00. MIN. SQUARE STEEL TUBING (BY �1/4' OTHERS) SEALANT TAPE TO BACK Robert. AmoNso, P.E. SIDE OF MOUNTING FIN 112' MIN. FL P.E. No.49752 2X WOOD FRAME EDGE DIST. 3/8' MIN, SEALANT TAPE EDGE DIST. (BY OTHERS) TO BACK SIDE OF MOUNTING FIN f" j g 1' MIN. EMBEDMENT { #8 WOOD SCREW #8 TAPPING SCREW THREE(3)THREAD INSTALLATION ANCHOR io�l..4i o. INSTALLATION ANCHOR MIN. PENETRATION Digitally signed by VERTICAL SECTION A WOOD FRAME SUBSTRATE VERTICAL SECTION Robert Robert) Am oruso rus C STEEL TUBING SUBSTRATE Date: 12:08:59.-05'00- a 114' MAX SHIM 1/4' MAX SHIM cn 1/2• MIN. EDGE DIST. 1/Y MIN. EDGE DIST. 2X WOOD FRAME (BY OTHERS) 2X WOOD FRAME a a (BY OTHERS) W 3 #8 WOOD SCREW' INSTALLATION ANCHOR INTERIOR WOOD SCREW INTERIOR INSTALLATION ANCHOR m � #8 X 314• SMS ♦� A �V. 1' MIN. c; rn N ,N o x v 4 p EMBEDMENT -I EMBEDMENT a z� o 12 o SEALANT TAPE TO BACK EXTERIORS SIDE OF MOUNTING FIN EXTERIOR RIOR SFALANTTAPETOBACK . E .�� W W co �c� _ SIDE OF MOUNTING FIN a4A � w w a .�N E E HORIZONTAL SECTION HORIZONTAL F WOOD FRAvffiSUBSTRATE WOOD 5 � Y jay A wZ> o> � 5 rA•� 7G 0 14 GA MIN. SQUARE 14 GA. MIN. SQUARE Wp 3/8' MIN. EDGE DIST. STEEL TUBING (BY OTHERS) INTERIOR STEEL TUBING (BY . 3/8• MIN. EDGE DIST. OTHERS) INTERIOR #8 TAPPING SCREW #8 TAPPING SCREWINSTALLATION INSTALLATION ANCHOR #8 X 3/4• SM ANCHOR THREE (3) THREAD r THREAD THREEATIO MIN. PENETRATION MIN. PENETRATION N • FL P.E. No. 497S2 SEALANT TAPE TO BACK EXTERIOR EXTERIOR SIDE OF MOUNTING FIN SEALANT TAPE TO BACK „nwi SIDE OF MOUNTING FWD?`;, v HORIZONTAL SECTION aWn,npcN„ %HORIZONTAL " •j STEEL TUB GSUBSTRATE Dlgltailysignedby J STEELTUBINU SUBSTRATE Robert J Amoruso Date: 2021.02.18 12:09:10-05r00'