Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProduct Evaluation Report; Roof Decki
Force Engineering &'Vesting
195-10 Rambiewood Drive
Humble, Texas 77338
Phone: f280540-6603 PAX: (28f)540-9966
Websile: www.forceengineeringtesling.com
Product Evaluation Report:
CARPORTS ANYWHERE
Hampton Rib Roof Pagel over opus framing
Florida Product Approval # 27402.1 R2
Florida Building Code 2020
Per Rule 61G20-3
Method: 1—D
Category: Structural Components
Subcategory: Roof Deck
Compliance Method: 61G20-3.005(1)(d)
NON HVHZ
Product Manufacturer:
Carport Anywhere
10858 S.E. County Road 221
Starke, Florida 32091
Engineer Evaluator:
Johnathan Green, P.E. # 88223
Florida Evaluation ANE ID: 12901
Validator-
Brian Jaks, P.E. #70159
Contents:
Evaluation Report Pages 1- 4
IN
c %b138223 °
Cr 6�
G ► �"
yn` 00
@) I I
FL# 27402.1 R2
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY JOHNATHAN
GREEN ON THE DATE
ADJACENT TO THE SEAL.
) COPIES OF THIS
ENT ARE NOT
-RED SIGNED AND
AND THE
IRE MUST BE
) ON ANY
JNIC COPIES.
1 •
Force Engineering & Testing
19531) Rambluivood Drive
Humble, Texas 77338
I'hune: (281) 540.6603 FAX: (281)54(1-996fi •
�Vebsitc: e•air.li:rccengincerinyllestin);.cmn
Compliance Statement:
The product as described in this report has demonstrated compliance with the
Florida Building Code 2020, Sections 1504.3,2,1504.7.
Product Description:
Hampton Rib 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide, through fastened
structural roof panel. Structural Application.
Panel Material/Standards:
Material:
26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50
29 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 80
Conforming to Florida Building Code 2020 Section 1507.4.3. Optional paint finish.
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2020, Section 1507.4.3.
Panel Dimension(s):
Thickness: 26 Ga.: 0.0185" min. order thickness
29 Ga.: 0.0142" min. order thickness
Width: 36" maximum coverage
Rib Height: Y4" major rib at 9" O.C.
Panel Roliformer: MRS Metal Roliforming Systems
Panel Fastener:
#12-14 x %" HWH SD#3 with 14mm neoprene bonded washing or approved equal.
Corrosion Resistance: Per Florida Building Code 2020, Section 1507.4.4.
Substrate Description:
Minimum 14 Ga. (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50) Steel
framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel
gauge. Framing must be designed in accordance w/ Florida Building Code 2020.
Allowable Design Pressures:
Table "A" 26 Ga. Hamoton Rib Roof Panel
Maximum Design Pressure:
-57.3 psf
-72.9 psf
-67.7 psf
+46.9 psf
+54.7 psf
Panel Fastener Pattern:
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
Panel Span:
5'-0" O.C.
4'-0" O.C.
4'-0" O.C.
5'-0" O.C.
4'-0" O.C.
Substrate:
Min.14 Ga.
Steel Framing
Min.14 Ga.
Steel Framing
Min.14 Ga.
Steel Framing
Min. IS Ga,
Steel Framing
Min.18 Ga.
Steel Framing
Design Pressure Includes a Safety Factor = 2.0.
FL# 27402.1 R2
ITEM HAS BEEN
'ALLY SIGNED AND
ED BY JOHNATHAN
.N ON THE DATE
CENT TO THE SEAL.
ED COPIES OF THIS
VENT ARE NOT
DERED SIGNED AND
!D AND THE
TUBE MUST BE
IED ON ANY
'RONIC COPIES.
F'
Force Engineering & Testing
19530 Ramblewood Drive
flumble.'rexas 77338
Phone: y281) 540.6603 FAX: (281) 540-9966
Website: Hsv-w.rurccengineeringtcsliiig.com
Table "B" 29 Ga. Hampton Rib Roof Panel
Maximum Design Pressure:
-57.3 psf
-150.9 psf
+39.0 psf
+143.1 psf
Fastener Pattern:
W-3°-W-3"-6"-3"-6"
6"-3"-6"-3"-6"3" 6"
6,•_3"-6"-3"-6"-3"-6"
6"_3•-6"4"_6"3"4„
Fastener Spacing:
4'-0" O.C.
2'-0" O.C.
4'-o" ox.
2'-0" O.C.
Design Pressure includes a safety Factor = z.0.
Code Compliance:
The product described herein has demonstrated compliance with
The Florida Building Code 2020, Section 1504.3.2, 1504.7.
Evaluation Report Scope:
The product evaluation Is limited to compliance with the structural wind load
requirements of the Florida Building Code 2020, as relates to Rule 61G20-3.
Performance Standards:
The product described herein has demonstrated compliance with:
■ ASTM E 1592-05 (2012) Test method for structural performance of
sheet metal roof and siding systems by uniform static air pressure
difference
■ FM 4471-92 - Foot Traffic Resistance Test
Reference Data:
1. ASTM E 1592-05 (2012) Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 667-0060T-18A-E, 667-0061T-18A-D
2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test
Force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 667-0060T-18F, 667-0061T 18E
3. Certificate of Independence
By Johnathan Green, P.E. (No. 88223) @ Force Engineering & Testing
(FBC Organization # ANE ID: 12901
Test Standard Equivalency:
1. The FM 4471-10, Foot Traffic Resistance test standard is equivalent to
FM 4471-92.
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
�b 68Ma
0
o e d 9 t4 a
�zrz
e�®d��G�AAL
QBulm
FL# 27402.1 R2
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY JOHNATHAN
GREEN ON THE DATE
ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE
SIGNATURE MUST BE
VERIFIED ON ANY
ELECTRONIC COPIES.
I
Force Engineering & 'testing
19530 Ramblewood Drier
Huntblejrc.xm 77338
I'hune: (281)540-6603 FARE (281)540-9966
website: wirn•.forceenginecrinl;lcstiag.com
Minimum Slope Range:
Minimum Slope shall comply with Florida Building Code 2020, including Section
1507.4.2 and In accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation:
Install per manufacturer's recommended details.
Insulation:
Manufacturer's approved product (Optional)
Roof Panel Fire Classification:
Fire classification is not part of this acceptance.
Shear Diaphragm:
Shear diaphragm values are outside the scope of this report.
Design Procedure:
Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2020 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his structure and analyze the panel fasteners for pullout and
pullover. Support framing must be In compliance with Florida Building Code 2020
Chapter 22 for steel, and Chapter 16 for structural loading.
ITEM HAS BEEN
ALLY SIGNED AND
ED BY JOHNATHAN
:N ON THE DATE
CENT TO THE SEAL.
COPIES OF THIS
ENT ARE NOT
=RED SIGNED AND
AND THE
IRE MUST BE
) ON ANY
DNIC COPIES.
FL# 27402.1 R2
G"
Force Engineering arc 'Vesting
19510 Ramblovood Drive
Humble, Texas 77338
Phone: 1281) 540-6603 FAX: (281) 540.066
Welmile: sre-w.forecenginecring( sling.cum
26 Q. HAIAPTON RIB FASTEIER PATTERN 2-1-2-1
`#12-14 x 314' KIM 503 W/ IMPA BONDED NEOPRENE i:ASHER
29 GA. HAIAPION RIB FASTENER PATTERN
5.. 3.. O. 3"
3'
1 4._
Q 12 -1 L x Sj = HY;11 SD.i 5V/ 1.1IA.' MIDED NEOPRENE VbNrH, R
ITEM HAS BEEN
ALLY SIGNED AND
ED BY JOHNATHAN
:N ON THE DATE
CENT TO THE SEAL.
I COPIES OF THIS
?NT ARE NOT
cRED SIGNED AND
AND THE
IRE MUST BE
) ON ANY
DNIC COPIES.
FL# 27402.1 R2