Loading...
HomeMy WebLinkAboutRevision-2103-0800 dopyaECENED AUG 2 3 2021 OFFICE USE ONLY: St.Lucie DATE FILED: PER]VIIT# :�-1 6 3—O KO REVISION FEE: RECEIPT# PLANNING&DEVELOPMENT SERVICES BUILDING&CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 (772)462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE ADDRESS: Whippoorwill Run Condos at 2947-2956 Bent Pine Dr Fort Pierce,FL 34951 DETAILED DESCRIPTION OF PROJECT REVISIONS: Install new 5/8"plywood over existing battens and replace existing skylights with new skylight lids CONTRACTOR INFORMATION: STATE of FL REG./CERT.#: CCC1326188 ST.LUCIE CO CERT. #: 27265 BUSINESS NAME: Atlantic Roofing of Vero Beach,Inc QUALIFIERS NAME: William Lasky,Jr. ADDRESS: 4310 45th St CITY: Vero Beach STATE: FL ZIP: 32967 PHONE(DAYTIME): 772-492-8493 FAX: 772-257-5740 OWNER/BUII.DER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE(DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: Seaside Engineers ADDRESS: 4265 60th Court CITY: Vero Beach STATE: FL ZIP: 32967 PHONE(DAYTIME): 772-202-8008 FAX: SLCCC: 9123109 Revised 06130117 DESIGN CRITERIA REVISIONS FBC 2020 ULTIMATE WIND SPEED, VULT 160 MPH EXPOSURE C. INTERNAL PRESSURE COEFFICIENT +/- 0.18 RISK CATEGORY II ROOF PITCH 5/12 HEIGHT & EXPOSURE COEFFICIENT 1.00 `s 1"X6"BATTENS 4" APART FASTENED — - ZONE 3 WIDTH, a 5FT (n TO TRUSS WITH (3)8d NAILS STANDING SEAM PANEL W o - FASTENED WITH 2"SCREWS C" (PER PRODUCT APPROVAL) Z c N ". @ 6.75"O.0 THRU BATTEN, 2 r PLYWOOD.AND TRUSS @ 16" N 0 O.C. Z L L LL TRUSS W Q � r o u W o cc c 5/8"PLYWOOD FASTENED TO Q coTRUSS WITH 10d RING-SHANK m o 0 NAILS @ 4"O.0 AT LAPS,6" (n .2 O.0 IN FIELD i! W U 4"BATTENS FASTENED 4"SPACE BETWEEN TRUSS TYP 24"O.0 /- TO TRUSS WITH(3)8d EXISTING 1"X6"BATTENS FiIP NAILS �I o 0 0 o e 0 R14V*l'EylWI E D F U Co. ° ODE COMPLIA AN ° ° ° ° ° ST. Lb�CIE COU ° ° SOCCRl'tz = 0 0 0 0 a N Q R¢0 Q¢0 0 if iS 0 0 'o C Q� Z o a r> 0 0 0 0 o U �9 LL C y 8 tl o o 7 m O O � N LL N ` 5/8" SHEETS 5/8"PLYWOOD END LAPS OF STANDING SEAM PANEL 2" O °o .d OF FASTENED TO 5/8"PLYWOOD SCREWS 6.75"O.0(PER a N PLYWOOD TRUSS WITH 10d FASTENED TO PRODUCT APPROVAL) o TYP.OVER RING-SHANK TRUSS WITH 10d LL BATTENS NAILS @ 6"O.0 RING-SHANK IN THE FIELD NAILS @ 4"O.0 Z Q J �o •.•• ••.. O O c % S s �i • N�VV dvy 0k PE•. = • 0 8 • .Vy • � V •• S E OF • Date NA a���•• '! 11, SHEET METAL ROOF PANEL FASTENING S-1 08/20/21 (6qf 21 Lq Product Evaluation Report Rule 61G20-3 F.A.C. I Report No. 2059, Rev. 5 1 Project No. 420-0913 1 11/30/20 1 PaVilef Cop- Manufacturer Product Series Model and/or Description I 63 Gl./�1 A Kennedy Skylights Curb Mounted GI R 5294 Tower Way Non-Impad3gd�cripart,OMPLIANCE Sanford, FL 32773V[''UC �r^ C �+ Code: Current Edition of the Florida Building Code including the 7th Edition(2020)Florida Bdildif5g� CIE COUNTY Compliance Methods: Product Approval Rule 61G20-3.005(l)(a)—Certification Mark or Listing Product Installation Instructions: • KENN0001, Rev. B,dated 12/6/17,signed and sealed by Robert J.Amoruso, Kennedy Skylights"ICMG" Curb Mounted Glass Skylight—LMI—HVHZ, Installation Anchorage Details • KENN0003, Rev.C, dated 12/14/19,signed and sealed by Robert J.Amoruso, Kennedy Skylights"CMG" Curb Mounted Glass Skylight- NI, Installation Anchorage Details • KENN0005, Rev.C.dated 12/14/19,signed and sealed by Robert J.Amoruso, Kennedy Skylights"SFG4" Curb Mounted Self Flashing Glass Skylight- NI, Installation Anchorage Details Engineering Analysis £t Product Evaluation: The following engineering and/or rational analysis/calculations have been performed. • Anchorage and product verification have been substantiated by calculation(PTC Report. No.2058-1 and 2058-2) prepared,signed and sealed by Robert J.Amoruso,P.E.in accordance with the current edition of the Florida Building Code. • Design Pressure Evaluation/Product Evaluation o Drawing No.KENN0001 ■ Product Name/Series:"ICMG"Curb Mounted Glass Skylight—LMI ■ High Velocity Hurricane Zone(HVHZ):YES ■ Outside High Velocity Hurricane Zone(HVHZ):YES ■ Impact Resistant:YES • Glazed laminated product using Kuraray Trosifol PVB Glass Interlayer by Kuraray America,Inc.Current Kuraray America NOA can be found here. • National Certified Test Laboratory, Inc.Test Report No. NCTL-210-3041-1,2 ■ Design Pressure • +/-60 psf • Margin of Safety=2 applied for positive and negative loading to Structural Design Pressure per Sections 1504 and 1523 of the current edition of the FBC and MD FAQ (http://www.miamidade.gov/building/products/skylights.asp). ■ Performance and Testing Standards • Test Report No.NCTL-210-3041-1,2 o TAS202-94 o TAS201-94 o TAS203-94 o Drawing No. KENN0003 ■ Product Name/Series:"CMG"Curb Mounted Glass Skylight-NI ■ High Velocity Hurricane Zone(HVHZ):NO • Outside High Velocity Hurricane Zone(HVHZ):YES ■ Impact Resistant:NO ■ National Certified Test Laboratory,Inc.Test Report No.NCTL-210-3041-3A ■ Design Pressure ��A!11111111111F PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 /m,/L 321-690-1788 1 FBPE Certification of Authorization No. 25935 Product Evaluation Report Rule 61G20-3 F.A.C. I Report No. 2059, Rev. 5 1 Project No. 420-0913 1 11/30/20 1 Page 2 of 3 • +/-95 psf outside HVHZ • Margin of Safety=2 applied to Structural Design Pressure per Sections 1504 of the current edition of the FBC. ■ Performance and Testing Standards • Test Report No. NCTL-210-3041-3A o AAMA/WDMA 1600/I.S.7-00,Voluntary Specification for Skylights o Drawing No.KENN0005 • Product Name/Series:"SFG4"Curb Mounted Self Flashing Glass Skylight-NI • High Velocity Hurricane Zone(HVHZ):NO • Outside High Velocity Hurricane Zone(HVHZ):YES ■ Impact Resistant:NO ■ National Certified Test Laboratory,Inc.Test Report No.NCTL-210-3012-1 ■ Design Pressure • +/-60 psf • Margin of Safety=2 applied to Structural Design Pressure per Section 1504 of the current edition of the FBC. ■ Performance and Testing Standards • Test Report No. NCTL-210-3012-1 o AAMA/WDMA 1600/I.S.7-00,Voluntary Specification for Skylights • Condensation Channel(Item No.3 on KENN0003 and Item No.8 on KENN0005)manufacturer has been changed to Omega Plastics.The condensation channel is a non-structural component that collects condensation on the skylight. It is an internal component offering no structural significance. Dimensionally and materially,the condensation channel remains consistent with the original component used in testing and is therefore acceptable. Performance Testing Standards: • TAS 201-94-Impact Test Procedures • TAS 202-94-Criteria for Testing Impact;Non-impact Resistant Building Envelope Components Using Uniform Static Air Pressure • TAS 203-94-Criteria for Testing Products Subject to Cyclic Wind Pressure Loading • AAMA/WDMA 1600/I.S.7-00,Voluntary Specification for Skylights Product Testing: • NCTL-210-3041-1,2,dated 10/5/04,signed and sealed by Gerald J.Ferrara,P.E.,testing to TAS 201/202/203-94 for "ICMG"Curb Mounted Glass Skylight • NCTL-210-3041-3A,dated 10/5/04,signed and sealed by Gerald J.Ferrara, P.E.,testing to AAMA/WDMA 1600- 00/I.S.7-2000 for"CMG"Curb Mounted Glass Skylight • NCTL-210-3012-1,dated 4/12/04,signed and sealed by Gerald J.Ferrara,P.E.,testing to AAMA/WDMA 1600- 00/I.S.7-2000 for"SFG4"Curb Mounted Self Flashing Glass Skylight Material Certifications/Component Approvals: • Laminated Glass Interlayer:See current Miami-Dade Notice of Acceptance(NOA)for component approval for Kuraray Trosifol PVB Glass Interlayer by Kuraray America,Inc.used in this product.Kuraray America NOA can be found here. Limitations ft Conditions of Use: • "ICMG"Curb Mounted Glass Skylight shown on KENN0001 o This product has been evaluated for use inside the HVHZ(High Velocity Hurricane Zone) o This product is Impact Resistance.Therefore,a protective impact-rated device is not required. PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 AWN AV 321-690-1788 1 FBPE Certification of Authorization No. 25935 Product Evaluation Report Rule 61G20-3 F.A.C. I Report No. 2059, Rev. 5 1 Project No. 420-0913 1 11/30/20 1 Page 3 of 3 • "CMG'Curb Mounted Glass Skylight shown on KENN0003 o This product has not been evaluated for use inside the HVHZ(High Velocity Hurricane Zone) o This product is not Impact Resistance.Therefore,a protective impact-rated device is required when used in a wind-borne debris region. • "SFG4"Curb Mounted Self Flashing Glass Skylight shown on KENN0005 o This product has not been evaluated for use inside the HVHZ(High Velocity Hurricane Zone) o This product is not Impact Resistance.Therefore,a protective impact-rated device is required when used in a wind-borne debris region. • Refer to Product Installation Instructions noted above for: o Maximum allowable wind loads at related maximum allowable size(s). o Overall dimensions and material/grade of main product components,accessories,etc. o Illustrated diagrams of the attachment of the product to the structure. o Anchor type(s),size(s),substrate(s),embedment,edge distance,and spacing/locations. • Site wind pressures shall be determined by a licensed professional engineer in accordance with the current edition of the Florida Building Code(and/or ASCE 7 as referenced in the current edition of the Florida Building Code)for components and cladding based on allowable stress design. • Site conditions not covered in this product evaluation document are subject to additional engineering analysis by a licensed professional engineer or registered architect as required by the authority having jurisdiction. • Adequacy of the existing structural substrates as a main wind force resisting system capable of withstanding and transferring applied product loads to the foundation is the responsibility of the licensed professional engineer or registered architect acting as the design professional of record for the project of installation. Certificate of Independence per Product Approval Rule 61G20-3.009 ,,`�1l3RAg�py���' Digitally signed �c�Q� �F.��EB PTC Product Design Group,LLC and RobertJ.Amoruso,P.E. ��`� •,`.��CEP1S�•C,St by Robert J does not have,nor will acquire,any financial interest in the '> a9'52 Amoruso.;* �� �;' : company manufacturing or distributing product(s)covered No it by this Product Evaluation Report. PTC Product Design Group, LLC and RobertJ.Amoruso,P.E.do not have,nor apt4� t Date: 7E OF :4l► will acquire an financial interest in an other entity �.� ' q Y Y Y . T :W. involved in the approval process or testing of the N���� 2020.11 .30 product(s)covered by this Product Evaluation Report. 17:36:26 -05 00 Evaluated by: Robert I Amoruso, P.E. FL PE License No. 49752 PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 r�s. 321-690-1788 1 FBPE Certification of Authorization No. 25935