HomeMy WebLinkAboutPHOTOVOLTAIC SYSTEM9.57 KWSYSTEM SIZE :10.73 KW DC STCVICINITY MAPSITE MAP (N.T.S)A-00SITE MAP &VICINITY MAPELSIENA MOODIENEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEMDC SYSTEM SIZE (10.73 KW)33°C0°C0 PSF160MPH (ASCE 7-16)IIB39.93 A(33) ENPHASE IQ7PLUS-72-2-USMICROINVERTERSLINE SIDE TAP IN THE MSPWIND FLOW MAP(3)BRANCHES OF 11 MODULESSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG.DC RATING OF SYSTEMAC RATING OF SYSTEMAC OUTPUT CURRENTNO. OF MODULESNO. OF INVERTERSPOINT OF CONNECTIONARRAY STRINGINGDESCRIPTIONNEW GRID-INTERACTIVE PHOTOVOLTAICSYSTEM WITH NO BATTERY STORAGESYSTEM DETAILSGOVERNING CODESFLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)NATIONAL ELECTRIC CODE, NEC 2017 CODE BOOK, NFPA 70SITE MAP & VICINITY MAPA - 00SYMBOLS & SYSTEM DESCRIPTIONA - 01S - 01ELECTRICAL LINE DIAGRAMWIRING CALCULATIONSSYSTEM LABELINGMODULE DATASHEETE - 01E - 02E - 03STRUCTURAL ATTACHMENT DETAILSINVERTER DATASHEETCOMBINER BOX DATASHEETATTACHMENT DATASHEETDS - 01DS - 02DS - 03DS - 04S - 02SHEET INDEXSHEET NO.SHEET NAMEROOF PLAN & MODULESARRAY LAYOUTS - 03RACKING DATASHEETDS - 05SITE DETAILSASHRAE EXTREME LOWASHRAE 2% HIGHGROUND SNOW LOADWIND SPEEDRISK CATEGORYWIND EXPOSURE CATEGORY(33) PEIMAR SM325M (FB) (325W) SOLARMODULES(E) UTILITY METER(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL(INSIDE HOUSE)MSPUMROOF 2103'-11"74'-5"103'-11"74'-5"ROOF 13'SETBACKROOF 3PV ARRAY18" SETBACKDRIVEWAYNE SUMMER RD 7'-4"33'-2"4'-10"29'-5"ROOF 4THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MINDY NICOLE O'NEAL, PE ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. A-01SYSTEM DESCRIPTIONSYMBOLS &SYSTEMDESCRIPTIONSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG. This system is a grid-tied PV system, with PV generation consisting of33 PEIMAR SM325M (FB) (325W) SOLAR MODULES with a combined STC rated dc outputpower of 10.73 KW. The modules are connected into 33 ENPHASE IQ7PLUS-72-2-USMICROINVERTERS. The inverter has electronic maximum power point tracking tomaximize energy captured by the PV modules. The inverter also has an internal groundfault detection and interruption device that is set to disconnect the array in the eventthat a ground fault that exceeds one ampere should occur. The inverter has DC and ACdisconnect integrated system and labels are provided as required by the NationalElectric CodeABBREVIATIONS:AC Alternating CurrentAPPROX ApproximateAWG American Wire GaugeCPDCCombiner PanelDirect CurrentDCDDISC(E)ELEQJBDirect Current DisconnectDisconnectExistingElevationEqualJunction BoxMCP Main Combiner PanelMFRMINManufacturerMinimumMISC(N)MiscellaneousNewOCPD OverCurrent Protection DevicePOCCPVSFPoint Of Common CouplingPhotovoltaicSquarefoot/feetSTCTBDTYPVIFWPStandard Test ConditionsTo Be DeterminedTypicalVerify In FieldWeather ProofSYMBOLS:Section..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel .........Combiner Panel ..........DC Disconnect ..........Main ServicePanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchATS00CPDCDMSPModule with SourceCircuit numberXX-XXXX-XXXX-XXXX-XXDetail ID LetterSheet wheresection is locatedDetail ID LetterSheet wheresection is locatedDetail ID LetterArea to be enlargedSheet wheresection is located1Keyed note designationon applicable sheetSheet wheresection is locatedMicroinvertersPV ModulesJunctionBoxPoint ofUtilityConnectionUtility MeterFigure 1: PV System Block DiagramWhen the sun is shining, power from the PV array is fed into the inverter, whereit is converted from DC to AC. The inverter output is then used to contribute to thepower requirements of the occupancy. If PV power meets the requirements of theloads of the occupancy, any remaining PV power is sold back to the utility. When utilitypower is available, but PV power is not available, building loads are supplied by theutility.The inverter meets the requirements of IEEE 1547 and UL 1741. This means thatif it detects a loss of utility power, it will automatically disconnect from the utility.When utility voltage is restored, the inverter automatically reconnects to the utilitygrid after verifying utility voltage and frequency stability. S-01 & MODULESROOF PLANPEIMARSM325M (FB)(325W) SOLARMODULESMODULE TYPE, DIMENSIONS & WEIGHTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG.I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3.BUILDINGSTRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFTWIND LOADS, AND EQUIPMENT DEAD LOADS. *GENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO TRUSSES SHALL BE INSTALLED AS SHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:.WIND ZONE 1: MAX SPAN 4'-0" O.C.WIND ZONE 2: MAX SPAN 4'-0" O.C.WIND ZONE 3: MAX SPAN 2'-0" O.C.2) EXISTING RESIDENTIAL BUILDING ROOF WITH MEAN ROOFHEIGHT 15 FT AND 2"x4" WOOD ROOF TRUSSES SPACED 24" O.C.CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THEENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANSAND IN FIELD CONDITIONS.LEGENDSUMACDPMMSP- UTILITY METERJB- AC DISCONNECT-PRODUCTION METER- MAIN SERVICE PANEL- VENT, ATTIC FAN(ROOF OBSTRUCTION)- JUNCTION BOXCP- COMBINER PANEL- CONDUIT- MICROINVERTER- FIRE SETBACKNUMBER OF MODULES = 33 MODULESMODULE TYPE = PEIMAR SM325M (FB) (325W) SOLAR MODULESWEIGHT = 41.01 LBS / 18.6 KG.MODULE DIMENSIONS = 65.55" X 39.45" = 17.96 SFNUMBER OF INVERTER = 33 MICROINVERTERSINVERTER TYPE = ENPHASE IQ7PLUS-72-2-US MICROINVERTERSDC SYSTEM SIZE: 10.73 KWAC SYSTEM SIZE: 9.57 KW39.45"65.55"NOTES:1. LOCATION OF JUNCTION BOX(ES), ACDISCONNECTS(S), AC COMBINER PANEL(S), ANDOTHER ELECTRICAL EQUIPMENT(S) RELEVANTTO PV INSTALLATION SUBJECT TO CHANGEBASED ON SITE CONDITIONS.2. SETBACKS AT RIDGES CAN BE REDUCED TO18 INCHES IN COMPLIANCE WITH FBC R 324.6.2:TOTAL PLAN VIEW AREA = 3441.9 SQFTTOTAL PV AREA = 33(65.55 IN)(39.45 IN)/(144 IN^2) = 592.61 SQFT( 592.61 SQFT/ 1973.83 SQFT)100 = 30.02 %TOTAL PV AREA POPULATES 30.02 % OF TOTALPLAN VIEW AREA AND IS WITHIN THE 33%REQUIREMENT.(E) UTILITY METER(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL(INSIDE HOUSE)MSPUMROOF 2CPACD(N) COMBINER PANEL(N) AC DISCONNECTJBCONDUIT RUNROOF 4ROOF 3ROOF 1ROOF ACCESS POINTROOF ACCESS POINTROOF ACCESS POINT(E) FRONT YAR D (E) BACK YARD ROOF 3PV ARRAY18" SETBACK3'SETBACK S-02ARRAYLAYOUTROOF DESCRIPTION:SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG.WIND LOAD INFORMATION:THIS SYSTEM HAS BEEN DESIGN TO MEETTHE REQUIREMENTS OF THE 7TH EDITION OFTHE FLORIDA BUILDING CODE AND USED THE FOLLOWING DESIGN PARAMETERS: ULTIMATE WIND SPEED: 160 MPHEXPOSURE CATEGORY: BRISK CATEGORY: llMEAN ROOF HEIGHT: 15 FTROOF SLOPE: 7-20°LEGENDS- VENT, ATTIC FAN(ROOF OBSTRUCTION)- PV ROOF ATTACHMENT- RAFTERS / TRUSSES- RAILS- FIRE SETBACK- WIND ZONE 1- WIND ZONE 1'WIND ZONE 2- WIND ZONE (2)- WIND ZONE (2r)-WIND ZONE (2e)- WIND ZONE (2n)WIND ZONE 3- WIND ZONE (3)- WIND ZONE (3r)-WIND ZONE (3e)- METAL SEAMWIND ZONE 1(ROOF #1)MODULES - 9ROOF TILT - 16°ROOF AZIMUTH - 277°TRUSSES SIZE - 2"X4" @ 24" O.C.(ROOF #3)(ROOF #2)MODULES -6ROOF TILT - 16°ROOF AZIMUTH - 190°TRUSSES SIZE - 2"X4" @ 24" O.C.MODULES -11ROOF TILT - 16°ROOF AZIMUTH - 93°TRUSSES SIZE - 2"X4" @ 24" O.C.(ROOF #4)MODULES -7ROOF TILT - 16°ROOF AZIMUTH - 140°TRUSSES SIZE - 2"X4" @ 24" O.C.ROOF #1ROOF #4ROOF #2ROOF #336'-4"8'-7"8'-6"14'12'-10"32'-5"1 3 ' - 4 "16'-11"10'-4"33'-5"8'8'-5"37'-2"16'-5"29'-2"17'-1"SOLAR MODULE3'SETBACK2 3 ' - 1 " 14'-4" 1'-11"28'-5"18" SETBACK PHOTOVOLTAIC MODULE GENERAL NOTES:1. APPLICABLE CODE: 2020 FLORIDA BUILDING CODE 7th ED. & ASCE 7-16MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER NDS(2012)REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A WOOD ROOF TRUSS AS EMBEDMENT MATERIAL.3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLERESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27° (2/12 TO AMAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOTEXCEED 30'-0" MEAN ROOF HEIGHT.4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511.5.THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TOMANUFACTURERS' MANUAL FOR ALL ARCHITECTURAL, MECHANICAL,ELECTRICAL, AND SOLAR SPECS.6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESSOTHERWISE NOTED.7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED.8.ALL RAILING AND MODULES SHALL BE INSTALLED PERMANUFACTURERS' INSTRUCTIONS.9. I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCEWITH FBC:BUILDING CHAPTER 16 AND FBC:RESIDENTIAL CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATEDWIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS.S-03STRUCTURAL ATTACHMENTDETAILSSTRUCTURAL ATTACHMENT DETAILSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG.IRONRIDGE XR10IRONRIDGE FLASH FOOTSOLAR MODULE5/16"x4" STAINLESSSTEEL LAG SCREWWOOD SHEATHINGRAFTERSIRONRIDGE FLASH FOOTSHINGLE FLASHINGRAFTERSIRONRIDGE XR10IRONRIDGE FLASH FOOTIRONRIDGE FLASH FOOTSHINGLE FLASHINGWOOD SHEATHING NOTE:1.SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE REQUIREMENTS OF THE NEC 2017, NFPA 70 AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDING MAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OF MODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURER AND MODEL NUMBER, AS APPLICABLE.2.PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTERSPACE IS INADEQUATE.E-01ELECTRICALLINE DIAGRAMSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG.SOLAR ARRAY (10.73 KW-DC STC)(33) PEIMAR SM325M (FB) (325W) SOLAR MODULES(3) BRANCHES OF 11 MODULESENPHASE IQ7PLUS-72-2-USMICROINVERTERSPV MODULESL2L1NG15A20A/2PL2L1GN G20A/2PL2L120A/2PL2L1(N)ENPHASE IQ COMBINER 3 (X-IQ-AM1-240-3) [WITH UP TO (4)2-POLE BREAKERS AND ENVOY COMMUNICATION GATEWAY](N)JUNCTION BOX600 V, NEMA 3RUL LISTED(3) 12/2 NM-b RUN IN ATTIC OR(3) #10 AWG THWN-2 - RED(3) #10 AWG THWN-2 - BLACK(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNQ CABLESTO UTILITY GRIDL1 L2 NL1 L2 NL2L1L2L1L2L1NGL2L1L2L1L2L1L1 L2 NEXISTING GROUNDINGLINE TAP USING INSULATIONPIERCING 705.12(A)150A/2P(E) MAIN BREAKER150A/2P, 240V(3) #6 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC, PVC, HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT RUNL2L1NGL2L1NG(N) AC DISCONNECT:240V, 60AMP, FUSED WITH 50A FUSESNEMA 3R, UL LISTEDBI-DIRECTIONALUTILITY METER1-PHASE, 240V(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL,150A RATED, 240V.(INSIDE HOUSE)(3) #6 AWG THWN-2IN 3/4" IMC, RMC, FMC, LFMC, PVC, HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT RUNNOTE:THE CIRCUIT BREAKER SHOWN FEEDING THE ENPHASE ENVOY IS FACTORY INSTALLED. THE SIZE OF THIS CIRCUIT BREAKER IS SUBJECT TO CHANGE BASED ON MANUFACTURER PREFERENCE IN ACCORDANCE WITH THE UL LISTING. ELECTRICAL NOTES1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR75 DEGREE C.3. CONDUCTOR TERMINATION AND SPLICING AS PER NEC 110.144. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE ASPOSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELEDAND READILY VISIBLE.9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE310.10 (D).16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLEFOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).E-02INVERTER SPECIFICATIONSMANUFACTURERENPHASEMODEL NO.IQ7PLUS-72-2-USMAX DC INPUT VOLTAGE60 VMAX OUTPUT POWER290 VANOMINAL AC OUTPUT VOLTAGE 240 VNOMINAL AC OUTPUT CURRENT1.21 AWIRINGCALCULATIONSMAX VOLTAGE DROP CALCULATIONCABLE SIZECABLE DESCRIPTIONONE WAYDISTANCE INFEET (D)BRANCHCURRENT (I)RESISTANCE OFCONDUCTOR(R)VOLTAGE (V)% VOLTAGEDROP=(0.2*D*I*R)/V#10 THWN-2JUNCTION BOX TOCOMBINER PANEL2039.931.242400.83SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG.ELECTRICAL CALCULATIONS:1. CURRENT CARRYING CONDUCTOR(A)BEFORE IQ COMBINER PANELAMBIENT TEMPERATURE = 33°CCONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(c)TEMPERATURE DERATE FACTOR - 0.96 ...NEC 310.15(B)(2)(a)GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a)CONDUCTOR AMPACITY= (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B)= [(11 x 1.21) x 1.25] / 0.96 / 0.8= 21.66 ASELECTED CONDUCTOR - #10THWN-2 ...NEC 310.15(B)(16)(B) AFTER IQ COMBINER PANELTEMPERATURE DERATE FACTOR - 0.96GROUPING FACTOR - 1 CONDUCTOR AMPACITY=(TOTAL INV O/P CURRENT) x 1.25 / 0.96 / 1 ...NEC 690.8(B)=[(33x 1.21) x 1.25] /0.96 / 1=51.99 ASELECTED CONDUCTOR - #6 THWN-2 ...NEC 310.15(B)(16)2. PV OVER CURRENT PROTECTION ..NEC 690.9(B)=TOTAL INVERTER O/P CURRENT x 1.25=(33 x 1.21) x 1.25 = 49.91 ASELECTED OCPD = 50ASELECTED EQUIPMENT GROUND CONDUCTOR (EGC) = #10 THWN-2 ... NEC 250.122(A)MODULE SPECIFICATIONMODEL NO.PEIMAR SM325M(FB)PEAK POWER325WRATED VOLTAGE (Vmpp)34.15 VRATED CURRENT (Impp)9.52 AOPEN CIRCUIT VOLTAGE (Voc)41.67 VSHORT CIRCUIT CURRENT (Isc)10.08 A WARNINGELECTRIC SHOCK HAZARD!DO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONPHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 39.93 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICEPHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDE-03WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNING PHOTOVOLTAICPOWER SOURCE!239-610-1093EMERGENCY CONTACTWARNING!INVERTER OUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNING!DEDICATED SOLAR PANELS DONOT CONNECT ANY OTHER LOADSSHUTDOWNSOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG.SYSTEMLABELINGLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION, COMBINER PANEL(PER CODE: NEC 690.13(B))LABEL LOCATION:AC DISCONNECT, INVERTER(PER CODE: NEC 690.54)LABEL LOCATION:CONDUIT RUNWAY(PER CODE: NEC690.31(G)(3)(4))LABEL LOCATION:MAIN SERVICE DISCONNECT(NEC 705.12(B)(3-4) & NEC 690.59)ADHESIVE FASTENED SIGNS:·ANSI Z535.4-2011 PRODUCT SAFETY SIGNS AND LABELS, PROVIDESGUIDELINES FOR SUITABLE FONT SIZES, WORDS, COLORS, SYMBOLS, ANDLOCATION REQUIREMENTS FOR LABELS. NEC 110.21(B)(1)·THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THEENVIRONMENT INVOLVED. NEC 110.21(B)(3)·ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLYADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT. IFC 605.11.1.3LABEL LOCATION:POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT(PER CODE: NEC 705.12 (B)(2)(c))[Not required if panelboard is rated not less than sum of ampere ratingsof all overcurrent devices supplying it]LABEL LOCATION:AC DISCONNECT, DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: NEC 690.56(C)(3))IFC 605.11.3.1(1) & 690.56(C)(1)(a) Label for PV Systems thatShut down the array and the conductors leaving the array DS-01DATASHEETMODULESHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG. DS-02DATASHEETINVERTERSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG. DS-03DATASHEETCOMBINER BOXSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG. DS-04DATASHEETATTACHMENTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG. DS-05DATASHEETRACKINGSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD08/11/2021DESIGNERREVIEWERDATEELSIENA MOODIE 270 NE SUMMER RD PORT SAINT LUCIE, FL 34983,USA Signature with SealADD : 13245 TAMAIMA TRAIL E #101,NAPLES, FL 34114, USACONTACT : 239-610-1093ENGG.