HomeMy WebLinkAboutCreekside Lot 73-ds.compactiono���NTr� • cFol�Os g 2Universal w m 02Sciences G 9`S TFSTING'Company • UES Project No: 3360.1800067.0000 Workorder No: 244613-1 Report Date: 09/14/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In -Place Density Test Report Client: D. R. Horton America's Builder 6123 Lyons Road Coconut Creek, FL 33073 Project: CMT CREEKSIDE Various Locations, TBD County, FL Area Tested: Lot 73 - 3235 Trinity Circle, Ft. Pierce Material: Backfill Reference Datum: 0 = Top of Fill The tests below meet the 95% minimum compaction requirement. UES Technician: Mark Rogers Date Tested: 09/02/2021 Type of Test: Field: ASTM D-6938 Nuclear Gauge Method Laboratory: ASTM D1557 Modified Proctor Maximum Optimum Field Dry Field Soil Pass Test Density Moisture Density Moisture Compaction or No. Location of Test Range (pcf) (%) (pcf) (%) (%) Fail 1 Northside of pad 0-1 ft 118.6 10.8 114.6 10.7 97 Pass 2 Southside of pad 0-1 ft 118.6 10.8 115.0 10.6 97 Pass 3 Eastside of pad 0-1 ft 118.6 10.8 115.4 10.5 97 Pass Remarks: Permit:2011-0191 Reviewed By GFA International, Inc FBPE Registry No.4930 �OMINIC,�C i, Digitally signed by Thomas D ..o = Montano:A01410000000178 No_W� -* * 18498DCD000019A3 �o.. FTA,EOF .:z��: Date: 2021.09.1411:53:33 -04'00' Thomas Dominic Montano Branch Manager STATE OF FLORIDA Professional Engineer No. 84146 This item has been digitally signed and sealed by Thomas Dominic Montano on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. The in -place density tests were performed within the foundation/building pad footprint of the referenced residential lot. The test results either meet or exceed the requirements of the FHA/HUD manual and the current edition of the Florida Building Code for soil compaction. The Contractor is responsible for maintaining the tested soil sub grade in the same condition that existed at the time UES performed the referenced density tests. UES is not responsible if the tested area is altered from the approved condition at the time of testing. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1