Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NOA
A I ' MIAMI-DADE ®�� MIANII-DADS COUNTY File PRODUCT CONTROL SECTION cpa9EE Foos SW 26 Street,Room208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES ® Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION ®®� (�®�r 6 F(786)315-2599 NOTICE OF ACCEPTANCE OA amidade ov/econom PGT Industries,Inc. 3 1070 Technology.Drive, North Venice,FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series"5570/2770"Vinyl Sliding Glass Door(Reinforced)w/wo 901&135°corners-L.M.I. APPROVAL DOCUMENT: Drawing No.MD-5570.0 Rev B,titled"Vinyl Sliding Glass Door NOA(LM)", sheets 1 through 21 of 21,prepared by manufacturer,dated 10/05/15 and last revised on 04/22/20, signed and sealed by A. Lynn Miller,P.E.,bearing the Miami-Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami-Dade County Product Control Section. NIISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitations: 1. See table 1 (sheet 7) and table 2(sheet 8)for applicable SGD unit sizes,design pressures,reinforcements types, glass types,sill riser(see tables B-1 &B-2,sheets 7-8)and anchor layout sheets requirements in 11 thru 16. 2. Rigid White PVC,Tan(Non-white)Rigid PVC and Brown coated(Painted or laminated)white Rigid PVC to be labeled per referenced NOA's requirements. 3. Egress operable doors must comply with min clear width or height per FBC requirement, as applicable. 4. Pocket walls under separate approval,to be reviewed by Building official LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and series and following statement: "Miami-Dade County Product Control Approved",noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County,Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA#17-0420.06 and consists of this page 1 and evidence pages E-1,E-2,E-3,E-4&E-5 as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I.Chanda,P.E. NOA No.20-0429.05 MIAMI-DARE COUNTY Expiration Date: April 14,2021 ' s�G� L�ryn�k Approval Date: October 08, 020 Pagel PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBNHTTED 1. Evidence submitted under previous NOA A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 11-010 7.04) 2. Drawing No. NID-5570.0,titled"Vinyl Sliding Glass Door NOA(LM)", sheets 1 through 21 of 21,prepared by manufacturer, dated 10105115,with revision A dated 04/05/17, signed and sealed by A. Lynn Miller,P.E. B. TESTS 1. Test report on 1)Uniform Static Air Pressure Test,per FBC,TAS 202-94 2)Large Missile Impact Test per FBC,.TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab,Inc.,Test Report No. FTL 8717, dated 12/07/15, signed and sealed by Idahnis Ortega,P.E. (Test report revised on 02/15/16 and 02/24/16) 2. Test report on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,per FBC, TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94. 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC,TAS 202-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab,Inc.,Test Report No. FTL 8546, dated 11/06/15, signed and sealed by Idahnis Ortega,P. E. (Test report revised on 01/04/16 and 02/11/2016) 3. Test report on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,per FBC, TAS 202-94 3)Water Resistance Test,per FBC, TAS 202-94 4)Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6)Forced Entry Test,per FBC,TAS 202-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab,Inc.,Test Report No. FTL 8547, dated 12/04/15, signed and sealed by Idalmis Ortega,P.E. (Test report revised on 02/15/16) 4. Test report on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,per FBC, TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC,TAS 202-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab,Inc., Test Report No. FTL 8548, dated 12/04/15, signed and sealed by Idalmis Ortega, P.E. (Test report revised on 01/04/16 and 02/11/1<' 1st,-7 I. L��h Ishaq I.Chanda,P.E. Product Control Unit Supervisor NOA No.20-0429.02 Expiration Date: April 14,2021 Approval Date: October 08,2020 E-1 I PGT Industries,Inca NOTICE OF ACCEPTANCE: EVIDENCE SUBAUTTED B. TESTS (continued) 5. Test report on 1)Air Infiltration Test,per FBC,TAS 202-94 2 Uniform Static Air Pressure Test,per FBC,TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94. 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 6)Forced Entry Test,per FBC, TAS 202-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab, Inc.,Test Report No. FTL 8549, dated 11106115, signed and sealed by Idahnis Ortega,P. E. (Test report revised on 12/04/15 and 02/11/16) 6. Test report on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,per FBC,TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94. 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab, Inc.,Test Report No. FTL 8552, dated 12/04/15, signed and sealed by Idalmis Ortega, P. E. (Test report revised on 02/15/2016) 7. Test report on 1)Uniform Static Air Pressure Test,per FBC, TAS 202-94 2)Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab,Inc., Test Report No. FTL 6638 (samples A-1 thru A-22), dated 11/19/10, signed and sealed by Jorge A. Causo,P. E.(Submitted under NOA No. 11- 0107.04) 8 Test report on 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,per FBC,TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94. 4)Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-9.4 6)Forced Entry Test,per FBC, TAS 202-94 along with marked-up drawings and installation diagram of vinyl sliding glass door,prepared by Fenestration Testing Lab, Inc.,Test Report No. FTL 6337(samples A-1 thru A-5), dated 12/06/10, signed and sealed by Jorge A. Causo,P. E.(Submitted under NOA No. I1-0107.09) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-2014, prepared by PGT, dated 12/09/15and last revised on 02/15/16, signed and sealed by Anthony L.Miller,P.E. (Submitted under NOA No. 15-1210.01). 2. Glazing complies with ASTME-1300-09. 15t"7 Ishaq I.Chanda,P.E. Product Control Unit Supervisor NOA No.20-0429.02 Expiration Date: April 14,2021 Approval Date: October 08,2020 E-2 r PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBNIITTED D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 15-0528.14 issued to Vision Extrusion Limited for their "White Rigid PVC Exterior Extrusions for Windows and Doors", dated 08/13/15, expiring on 09/30/19. 2. Notice of Acceptance No. 16-0920.08 issued to Vision Extrusion Limited for their"VE 1000 Tan 202 and lighter Shades (Non-White)Rigid PVC Exterior Extrusions for Windows and Doors", dated 12/08/16, expiring on 12/29/21. 3. Notice of Acceptance No. 15-0528.15 issued to Vision Extrusion Limited for their "Brown Coated(Painted or Laminated)White Rigid PVC Exterior Extrusions for Windows and Doors", dated 08/13/15, expiring on 09/30/19. 4. Notice of Acceptance No. 16-0712.02 issued to ENERGI Fenestration Solutions USA, Inc. for their"TAN 3040 and Lighter Shades (Non-White)Rigid PVC Exterior Extrusions for Windows and Doors" dated 09/15/16, expiring on 02/04/21. 5. Notice of Acceptance No. 16-0712.04 issued to ENERGI Fenestration Solutions USA, Inc. for their"Bronze and Lighter Shades of Cap Coated Rigid PVC Exterior Extrusions for Windows and Doors" dated 09/15/16, expiring on 04/16/20. 6. Notice of Acceptance No. 16-0712.03 issued to ENERGI Fenestration Solutions USA, Inc. for their"White Rigid PVC Exterior Extrusions for Windows and Doors" dated 08/10/17, expiring on 02/28/18. 7. Test reports No(s). 10-002-792(A), 10-06-M0527, 535753-09,per ASTME-84, ASTMD1929 and ASTMD-635,issued by EXOVA to Vision Extrusion for cellulosic composite material. (Submitted under NOA No. 11-0107..04) 8. Notice of Acceptance No. 14-0916.11 issued to Kuraray America.,Inc. for their "SentryGlas® (Clear and White)Interlayer", expiring on 07/04/18. 9. Notice of Acceptance No.16-1117.01 issued to Kuraray America, Inc. for their "Trosifol®Ultraclear, Clear and Color PVB Interlayers", expiring on 07/08/19. F. STATEMENTS 1. Statement letter of conformance with FBC-511 Edition (2014) and FBC-6th Edition (2017), issued by manufacturer, dated 08/14/17, signed&sealed by Lynn Miller,P.E. 2. Statement letter of no financial interest, dated 04/18/17, issued by manufacturer, signed &sealed by Lynn Miller,P.E. 3. Letter of lab compliance,part of the above test reports. 4. RER Test Proposal No. 17-0387, dated 05/05/17, signed by Ishaq Chanda,P.E. G. OTHER 1. Notice of Acceptance No. 15-1210.01, issued to PGT Industries, for their Series "5570/2770"Vinyl Sliding Glass Door(Reinforced)—L.- -- - 1/14/21. I s�G� f• L�tgn� Ishaq I.Chanda,P.E. Product Control Unit Supervisor NOA No.20-0429.02 Expiration Date: Apri114,2021 Approval Date: October 08,2020 E-3 PGT Industries,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. New Evidence Submitted A. DRAWINGS 1. Drawing No. MD-5570.0 Rev B,titled"Vinyl Sliding Glass Door NOA(LM)", sheets 1 through 21 of 21,prepared by manufacturer, dated 10/05/15 and last revised on 04/22/20, signed and sealed by A. Lynn Miller,P.E. B. TESTS 1. Test reports on: 1)Air Infiltration Test,per FBC,TAS 202-94 2)Uniform Static Air Pressure Test,Loading per FBC,TAS 202-94 3)Water Resistance Test,per FBC,TAS 202-94 4) Large Missile Impact Test per FBC,TAS 201-94 5) Cyclic Wind Pressure Loading per FBC,TAS 203-94 along with marked-up drawings and installation diagram of all PGT Industries, Inc. representative units listed below and tested to qualify Dowsi1791 and Dowsi1983 silicones, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: FTL-7897,PGT PW5520 PVC Fixed Window(unit 6 in proposal), dated 09/03/14 FTL-20-2107.1,PGT SGD780 Aluminum Sliding Glass Door(unit 7 in proposal)FTL-20- 2107.2,PGT CA740 Alum. Outswing Casement Window(unit 8 in proposal)FTL-20- 2107.3,PGT PW7620A Aluminum Fixed Window(unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window(unit 10 in proposal) dated 07/13/20, all signed and sealed by Idalmis Ortega,P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 71 Edition (2020), dated 04/22/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller,P.E. 2. Glazing complies with ASTM E1300-04,-09,-12 and-16. D. QUALITY ASSURANCE Miami-Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America,Inc. for their "Trosifol® Ultraclear, Clear, and Color PVB Glass Interlayers", expiring on 07/08/24. 2. Notice of Acceptance No. 17-0808.02 issued to Kuraray America,Inc. for their "SentryGlas® (Clear and White) Glass Interlayers", expiring on 07/04/23. 3. Notice of Acceptance No. 18-1106.10 issued to Vision Extrusions Limited for their "Brown Coated (Painted or Laminated) White Rigid PVC Exterior Extrusions for Windows and Doors", expiring on 09/30/24. 4. Notice of Acceptance No. 18-1106.11 issued to Vision Extrusions Limited for their series "VE 1000 Tan 202 and lighter shades (Non—White)Rigid Cellular PVC Exterior Extrusions for Windows and Doors", expiring on 12/29/21. Ishaq I.Chanda,P.E. Product Control Unit Supervisor NOA No.20-0429.02 Expiration Date: April 14,2021 Approval Date: October 08,2020 E-4 i� I f CGI Windows and Doors,Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED E. MATERIAL CERTIFICATIONS (continue) 5. Quanex Part Super Spacer Standard complying with ASTM C518 Thermal Conductivity 0.881 BTU-in/hr.-ft2-OF,ASTM F 1249 WVTR-Pass,ASTM D3985 Oxygen—Pass,ASTM E 2190 I.G. Durability-No Fog-Pass.(Submitted under previous NOA No. 15-0409.05) 6. Quanex Part Duraseal complying with ASTM C518 Thermal Conductivity 2.22 BTU-in/ hr.-ft2-'F, ASTM F 1249 WVTR-Pass, ASTM D 1434 Argon Permeance-Pass, ASTM E 2189 I.G. Durability-No Fog, ASTM E 546 Dew Point Development -20OF in 48 hrs.(Submitted under NOA No. 15-0409.05). 7. Vision Extrusions, Ltd. Parts complying with PVC-AAMA 303-13, Voluntary Specification for Rigid Polyvinyl Chloride (PVC) Exterior Profiles for Vision Extrusions, Ltd.-VEX-1 by AAMA Fenestration Exterior Profile Certification Program. (Submitted under NOA No. 15- 0409.05) 8. Vision Extrusions, Ltd.Parts complying with PVC-AAMA 303-13. (Submitted under NOA No. 15-0409.05) 9. PVC-AAMA 303-13, Voluntary Specification for Rigid Polyvinyl Chloride (PVC) Exterior Profiles for Vision Extrusions, Ltd.-VEX-1 by AAMA Fenestration Exterior Profile Certification Program. 10. Notice of Acceptance No. 18-1217.14 issued to Energi Fenestration Solution, USA, Inc. for their "Tan 3040 & light shade (non-white) White Rigid PVC Exterior Extrusions for Windows and Doors", expiring on 02/04/21. 11. Notice of Acceptance No. 18-0122.02 issued to Energi Fenestration Solution, USA, Inc, for their series "White Rigid PVC Exterior Extrusions for Windows and Doors", expiring on 02/28/23. 12. Notice of Acceptance No. 20-0203.03 issued to Energi Fenestration Solution, USA, Inc. for their "Bronze & light shade cap coated White Rigid PVC Exterior Extrusions for Windows.and Doors", expiring on 04/16/25. F. STATEMENTS 1. Statement letter of conformance to FBC 7" Edition (2020), dated 04/22/20, issued by manufacturer,-signed and sealed by Anthony Lynn Miller,P.E. 2. Statement letter of no financial interest and of independent, issued by manufacturer, dated 04/18/20, signed and sealed by Anthony Lynn Miller,P.E. 3. Private Labeling Agreement document in conformance with the Product Control guidelines, dated 03/30/15 and signed by all involved parties (Submitted under NOA No. 15-0409.05). G. OTHERS 1. This NOA revises NOA#17-0420.06(PVT w/PGT) and updates to FBC2020 (7th Edition), expiring 04/21/21. 2. RER Test proposals #19-1155 dated 01/10/20 approved by Ishaq I. Chanda,RE, expiring 04/14/21. 1s�G� l• L�hn�. Ishaq I.Chanda,P.E. Product Control Unit Supervisor NOA No.20-0429.05 Expiration Date: April 14,2021 Approval Date: October 08,2020 E-5 SERIES 5570 IMPACT RESISTANT SLIDING GLASS DOOR IMPACT RATING DESIGN PRESSURE RATING RATED FOR LARGE&SMALL SEE TABLES 1,2&61,B2 GENERAL NOTES: INCLUDING POCKETS & 900/1350 CORNERS TABLE A: MISSILE IMPACT RESISTANCE ON SHEETS 7&8 1)GLAZING TYPE OPTIONS:SEE GLAZING DETAILS ON SHEET 10. Min:Edge Min. 2)DESIGN PRESSURES: Group Anchor Substrate Frame Member Distance Embedment A.NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS PER ASTM E1300. P.T.Southern Pine,(SG=0.55) Head/SIIIIJamb/P-hook 9/16" 1-3/8" B.POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE AND GLASS PER ASTM E1300. #12,steel SMS(G5)or Aluminum,6063-T5"(0.125"min.) Heed/SIIUJamb/P-hook 3J8" 1/B" C.DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN,ASD. 410 S.S.SMS Steel,A36%(0.060"min.) Head/Sill/JamblP-hook 318" 0.060" 3)ANCHORAGE:THE 33-1/3%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT.MATERIALS, A (min.11 threada/ln) Steel Stud,A653 Gr.33•, 0.071"min.) Head/Sill/Jamb/P-hook 3/8" 0.071" 14 Ga. INCLUDING BUT NOT LIMITED TO STEEL SCREWS,THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS 1/4"Elco Ultracon Head/SIIUJamb1P-hook 1" 1-3W SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE(FBC). 1/4"DeWalt Ultracon+ P.T.southern Pine,(SG=0.55) Jamb 1" 1-3/8" 4)SHUTTERS ARE NOT REQUIRED PER FBC REQUIREMENTS,AS APPLICABLE. 1/4"Elea 410 S.S.CreteFlex Head/Sill/JamblP-hook 1" 1-3/8" 5)INSTALLATION SCREWS&FRAME SPLICES TO BE SEALED WITH NARROW JOINT SEALANT.OVERALL a 1 #12.steel wood screw G5 P.T.Southern Pine, SG=0.55 Head/Sill/Jamb/P-hook 9116, 1-3/8" SEALING/FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS Concrete,(min.2.85 ksl) P-hook 1" 1-318" BEYOND THE SCOPE OF THESE INSTRUCTIONS. 1/4"Elco Ult acon Headb/P-hook 1 Tp 1-3/8" 6 REFERENCES(NOA'S):ELCO ULTRACON,DEWALT ULTRACON+,DEWALT/ELCO CRETEFLEX&AGGRE-GATOR Ungrouted CMU,(ASTM C-9D) Jamb/P•ham 1" 1-1/4" Concrete,(min.3 ksl) Head/Sill/Jamb 1-V 1-3/8" ANCHOR NOA'S,ENERGI FENESTRATION SOLUTIONS USA,INC.OR VISION EXTRUSION,LTD.WHITE RIGID PVC NOA,VE 1l4"DeWalt Ultracon+ P-hook 1" 1-3/8" 1000 TAN 202 AND LIGHTER SHADES(NON-WHITE)RIGID PVC NOA AND BROWN COATED(PAINTED OR LAMINATED) C Ungrouted CMU, ASTM C-90 JamblP-hook 1" 1-1/4" WHITE RIGID PVC NOA 1/4"DeWaIVEIco 410 S.S. Ungrouted CMU,(ASTM C-90) JamblP-hook 1-3/4" 1-1/4" REFERENCES(TEST REPORTS):FTL-6337,6338,8646-8649.8652&8717;EXOVA-10-002-792(A)&10-006-10231; Head/SiIUJamb 1-3/16" 1.314" CAMBRIDGE 535753-09; CreteFlex Concrete,(min.3.35 ksi) P-hook 1" 1-314" 7)THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FBC, INCLUDING THE 14'DeWall/Elco 16-e S.S. Core a,(min.2.22 ksi) Head/SIIUJamb/P-hook 1-112" 1-3/8" HIGH VELOCITY HURRICANE ZONE(HVHZ).THE RIGID WHITE,BROWN&TAN PVC MANUFACTURED BY ENERGI Aggre-Gator Ungrouted CMU,(ASTM C-90) JamblP-hook 2" 1-1/4" FENESTRATION SOLUTIONS USA,INC.OR VISION EXTRUSION,LTD.HAS BEEN TESTED TO COMPLY WITH THE FLORIDA P.T.Southern Pine, SG=0.55) Head/Sill/JamblP-hook 1" 1-3/6' BUILDING CODE FOR PLASTICS, COMPONENT REQUIREMENTS). 1/4':Elco Ultracon Concrete,(min.2.85 ksl) HBad/S111/Jamb/P-hook 2-1/2" 1-3/9' ( ) Ungrouted CMU,(ASTM C-90) Jamb/P-hook 2-1/2" 1-1/4" 8)DOOR SIZES MUST BE VERIFIED FOR COMPLIANCE WITH EGRESS REQUIREMENTS OF THE FBC,AS APPLICABLE, Concrete,(min.3 ksl) Head/Sill/Jamb/P-hook 2-1/2" 1-3l8" 9)DRAWINGS DEPICT EXTERIOR-GLAZING,HOWEVER INTERIOR-GLAZING MAY BE SUBSTITUTED. D 1/4"DeWalt Ultracon+ Ungrouted CMU,(ASTM C-90) Jamb/P-hook 2-112" 1-114" 10)THE 5570 SERIES SLIDING GLASS DOOR MAY ALSO BE KNOWN AS THE 570/2770 SERIES. Head/SIIUJamb 2-1/2' 1-3/4" 114"DeWalt/Elco 410 S.S. Concrete,(min.3.35 ksi) p-hook 2-1l2" 1-31B" ANCHOR NOTES: CreteFlex Un routed CMU,(ASTM C-90) JamblP-hook 2-112" 1-114" 1)FOR CONCRETE/CMU SUBSTRATE APPLICATIONS IN MIAMI-DADE COUNTY,USE ONLY MIAMI-DADE COUNTY •MIN.OF 3 THREADS BEYOND THE METAL SUBSTRATE.METAL SUBSTRATE TO APPROVED ELCO ANCHORS.SEE TABLE A ON THIS SHEET FOR EMBEDMENT,EDGE DISTANCE AND SUBSTRATE MEET MIN.STRENGTH AND THICKNESS REQUIREMENTS PER CURRENT FLORIDA PRODUCT REVISED REQUIREMENTS. BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. as complying with the Florida 2 FOR OTHER SUBSTRATE APPLICATIONS SEE TABLE A ON THIS SHEET. Building Coda NOA-No. 20-0429.05 3)WOOD BUCKS DEPICTED AS 1X ARE LESS THAN 1-1/2"THICK PROPERLY SECURED,1X WOOD BUCKS ARE OPTIONAL "UNGROUTED CMU"VALUES MAY BE USED FOR GROUTED CMU APPLICATIONS. Expiration Date:04114/2021 IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE OR CMU.WOOD BUCKS DEPICTED AS 2X ARE 1-1/2"THICK OR GREATER.1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE FOR THE MINIMUM STRENGTHS OF BY: STRUCTURE.BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD ANCHORS AND SUBSTRATES,SEE TABLE GENERAL NOTES.............1 Miami-Dade Product Control &TO BE REVIEWED BY THE BUILDING OFFICIAL. F,SHEET 21. EXAMPLE CONFIGS..........2 4)METAL SUBSTRATE TO MEET MIN.STRENGTH AND THICKNESS REQUIREMENTS PER THE FBC AND TO BE REVIEWED INSTALL DETAILS..............3-6 BY THE AUTHORITY HAVING JURISDICTION. DP/ANCHOR TABLES........7-8 5)IF SILL IS TIGHT TO SUBSTRATE,GROUT OR OTHER MATERIAL IS NOT REQUIRED.IF USED,NON-SHRINK, EXAMPLE............................9 NON-METALLIC GROUT,MAX.1/4"THICK&3400 PSI MIN.,(DONE BY OTHERS)MUST FULLY SUPPORT THE ENTIRE CODES/STANDARDS USED: GLAZING DETAILS............10 LENGTH OF THE SILL THAT IS NOT TIGHT TO THE SUBSTRATE,AND TRANSFER SHEAR LOAD TO SUBSTRATE.IF •2020 FLORIDA BUILDING CODE(FBC),TTH EDITION ANCHOR LOCATIONS.......11-16 SUBSTRATE IS WOOD,30#FELT PAPER OR MASTIC IS REQUIRED BETWEEN THE GROUT AND WOOD SUBSTRATE,OR 'AST E1300-A BUILDING CODE(FBC),sTH EDITION PANEL TYPES...................17 •ASTM E1300-09 EXTRUSIONS.....................18 AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. •ANSI/AF&PA NDS-2018 FOR WOOD CONSTRUCTION ACCESSORIES..................19 •ALUMINUM DESIGN MANUAL,ADM-2015 INSTRUCTIONS: AISI S100.16 SCREEN DETAILS.............20 .`'ONY LYN/V���•, • 1) KNOWING THE REQUIRED DESIGN PRESSURE OF THE OPENING,THE ANCHOR REQUIREMENTS FOR THE •AISC 360.16 PARTS LIST........................21 ���.• �tccNse �(�'; SLIDING GLASS DOORS MAY BE DETERMINED FROM DESIGN PRESSURE TABLES 1 OR 2,DEPENDING ON THE GLASS/REINFORCEMENT. No.5B705 VINYL SLIDING GLASS DOOR NOA(LM) 8 10/05/15 2)LOCATE THE SLIDING GLASS DOOR SIZE ON THE TABLE,USING THE FRAME HEIGHT AND THE NOMINAL PANEL = WIDTH IF YOUR EXACT SIZE IS NOT LISTED,ROUND UP TO THE NEXT GREATER LISTED WIDTH AND/OR HEIGHT. GENERAL NOTESm J ROSOWSKI l '•, �y 0O; 3)CHOOSE WHICH ANCHOR GROUP(A-D)IS MOST APPLICABLE.ANCHORS ARE DEFINED IN TABLE A,THIS ® p •, S fATr e dF C(/ SHEET,ALONG WITH THE CORRESPONDING SUBSTRATE,MINIMUM EMBEDMENTAND MINIMUM EDGE DISTANCE. z B)UPDATED TO FBC 2020,ANCHOR TYPES 03/23/204)FROM THE DESIGN PRESSURE TABLES(TABLES 1 OR 2),VERIFY THAT 'i��` '-.�LORIDP.•'''G?� PRESSURES MET OR EXCEEDED.USE THE ANCHOR QUANTITIES SHOWN.HE OPENING'S REQUIRED DESIGN 1070 TECHNOLOGY DR /,S//j0NA1-1� 5)INSTALL AS PER THE GUIDELINES OF THIS SHEET-SET. N.VENICE,FL 34275 6)ADDITIONALLY,SEE THE EXAMPLE ON SHEET 9. (941)-480-1600 SGD-5570 NITS 111 1 OF 21 3 MD-5570.0 �$ B A LYNN MILLER,RE REGISTRATION#29296 P.E.#58705 MAX.UNIT WIDTH MAX.UNIT WIDTH MAX.UNIT WIDTH MAX.UNIT WIDTH NOM.PANEL WIDTH NOM.PANEL WIDTH NOM.PANEL WIDTH +� NOM.PANEL WIDTH q PER TABLES 1&2 +� PER TABLES 1&2 PER TABLES 1&2 , PER TABLES 1&2 MAX..UNI IT , / �� MAX..UNII T 3 / s / a �� MAX.UNIT a ' a HEIGHT HEIGHT ID HEIGHT /R / 6 I HEIGHT 6 I PER 3 3 3 PER TABLES 1&2 PER TABLES I&2 / / I2 PER TABLES I&2 h � �g TABLES 1; &2 PoCKEf I PoCNET I I / I POCKET POCI�TIN J _I -tom J .J 1-PANEL + 2-PANEL 3-PANEL CONFIGURATIONS 4-PANEL CONFIGURATIONS CONFIGURATIONS CONFIGURATIONS 4 + MAX.UNIT WIDTH MAX.UNIT WIDTH MAX.UNIT WIDTH NOM.PANEL WIDTH NOM.PANEL WIDTH NOM.PANEL WIDTH PER TABLES 1&2 PER TABLES 1&2 + ] PER TABLES 1&2 MAX.UNIT111P 3 I ] IHEIGHT NOTE3 3 3 3 8 3 ] 3 3 3 6 g N,TEMAX.UNIT MAX.UNIT IW PSEE ER HEIGHT 3 0 HEIGHT 3 3 3 6 �" TABLES 1&2SHEET. PER TABLES 1&2 / PER TABLES 1&2 / I C 5-PANEL CONFIGURATIONS + 6-PANEL CONFIGURATIONS + OUTSIDE CORNER SHOWN,INSIDE CORNER SIMILAR MAX.UNIT WIDTH MAX.UNIT WIDTH PRODUCT REVISED as comp ngg with the Florlde Buliding odu NOM.PANEL WIDTH NOM.PANEL WIDTH Non-No. 20-0429.05 PER TABLES '[ 1&2&2 PER TABLES 1&2 Expiration Date:04/14/2021 T D I I BY:_1 s-7 3 3 I 3 3 MIamLDado Product Control MAX.UNIT 9 3 3 3 7 / 6 Ig MAX.UNIT HEIGHT 3 3 3 3 3 J / IL^ HEIGHT PER TABLES I&2 / / / / / / / I? PER TABLES I&2 Fv t I I ,/ PoCMEr Ci 7t 7-PANEL CONFIGURATIONS L 8-PANEL CONFIGURATIONS 4 CONFIGURATIONS NOTES: DTH_ NOM"O"=INOPERABLE EAPANEL NOM.NEL DLO WIDTH PANELANEL WIDTH+11311611 ���NAN L NIv 1)ALL CONFIGURATIONS SHOWN ARE ALSO AVAILABLE AS POCKET CONFIGURATIONS AT EITHER OR BOTH JAMB ��V LYN LOCATIONS.EXAMPLE:4-PANEL XXXX IN POCKET(p)CONFIGURATION CAN BE pXXXXp,pXXXX OR XXXXp.OXXX IN „p,=POCKET DLO HEIGHT=DOOR HEIGHT-11-1/16" ;` ��0.•``.�NSN�I/e PANEL �•' F ��� POCKET CONFIGURATION CAN BE OXXXp. 2)90+&135-CORNER CONFIGURATIONS ARE A COMBINATION OF ANY 2 STRAIGHT CONFIGURATIONS. VINYL SLIDING GLASS DOOR NOA(LM) 8 10/05/15 _ No.58705 x EXAMPLE CONFIGURATIONS t- J ROSOWSKI = o rc_ 3)POCKET WALL OR CAVITY IS NOT PART OF THIS APPROVAL AND IS TO BE DESIGNED BY OTHERS AND %?1 '. REVIEWED BY THE AUTHORITY HAVING JURISDICTION. ® O�'., ATE OF ((7 DETAIL LETTER B)NO CHANGES THIS SHEET. �� 03/23/20 �s•.,F(ORIOF.•''�\� 4)FOR NOM.PANEL WIDTH,SEE TABLES I&2. 1 070 N.VENICEO OGY DR a�g 11 �ONALIE 5)MAX.ALLOWABLE FRAME SQUARE FOOTAGE=472.656 FT1 )---SHEET NUMBER (941)-480-1600 SGD-5570 NTS 2 OF 21 g MD-5570,0 � B A.LYNN MILLER,P.E. REGISTRATION g29286 P.E#58705 DETAIL Al DETAIL 81 METAL TYP.,SEE ANCHOR THRU IX WOOD ASTRAGAL DETAIL CII DETAIL D1 NOTE 4,SHEET 1;MIN.OF 3 INTO MASONRY FACING EXT. INTERLOCK INTO METAL CONCRETEJCMU PER THREADS BEYOND THEMETAL ANCHOR REQUIREMENT FRAME WIDTH SUBSTRATE --.•{I 1/4"MAX. REQUIRED IF DOOR TYP.ANCHOR TYPE, .'. I HEIGHT IS OVER 96" J 21 18 EMBEDMENT AND 94 MAX 28"O.C. / 91 EDGE DISTANCE PER . 22 EDGE SUBSTRATE,SEE +' �0 71 a q DISTANCE TABLE A,SHEET 1& ���JJJJ 4 so NOTE 3,BELOW DAYLIGHT 10 INTERIOR OPENING zs a WIDTH 33 o d b e EMBEDMENT o a p a P 31 EDGE (4)THRU KEEPER @ MAX o� EDGE DISTANCES• . ' zs o 2e 80 I B2 EXTERIOR 3.5"O.C.,SEE SHEET 19 98 DISTANCE NOTE S, 94 I I 25 0 26 Tl 27 0Re SEE NOTE 6, • •, 1X OR 2X WOOD THIS SHEET I SEE NOTE , v THIS SHEET 5 / BUCKSTRIP,SEE SEE NOTE 6,THIS SHEET 29 I 32 THIS SHEET EMBEDMENT ANCHOR / / NOTE 3,SHEET 1 L —————. #8 X 3/4"SMS REINFORCEMENT SCREW;7 PLATE AT / 63 PER STILE,LOCATED AT CENTERLINE AND 6", TYP.ANCHOR TYPE, E EVERY / HORIZONTAL SECTION(XXX SHOWN) _ 9"&12"FROM ENDS(FACTORY INSTALLED). EMBEDMENT AND ANCHOR �� EDGE DISTANCE PER LOCATION DETAIL C2 DETAIL D2 ,, __ DETAIL B2 TABLE A,,SHEET E& DETAIL A2 INTERLOCK INTO MASONRY ASTRAGAL NOTE 3,BELOW INTO 2X WOOD 1 2X WOOD BUCKSTRIP OR REQUIRED IF DOOR EMBEDMENT FACING INT. FRAMING,SEE ANCHOR 19 DAYLIGHT 21 HEIGHT IS OVER 98" ———--- NOTE 3,SHEET 1 OPENING 91 1/4'MAX' -�( l Q WIDTH 22 EDGE II INTERIOR I .aa comptylPRODUCng REVISED 1 DISTANCE BuildingCode TYP.ANCHOR TYPE, 1Jo P SEE NOTE s,THIS SHEET 7 I I Non-N. 20-0429.0S EMBEDMENT AND 28 R 27 zr R 25 L� I Expiration Date:0411412021 EDGE DISTANCE PER cJ o 0 93 23 a TYP.ANCHOR TYPE, I I Dy SUBSTRATE,SEE e ab =::EMBEDMENTAND P q Miami-Dads Product Control TABLE A,SHEET 1& 31 p�l c o p EDGE•DISTANCE NOTE 3,BELOW I un PER SUBSTRATE, SEE TABLE A,SHEET I a Q d I EDGE q THRU KEEPER @MAX v d 1$NOTE 3,BELOW DISTANCE ( �0 99 ) EXTERIOR 3.5"O.C.,SEE SHEET 19 �1 I PANELWIDTH L-v----J - 1/4"MAX. CONCRETE/CMU PER ASTRAGAL MAY BE EMBEDMENT HORIZONTAL SECTION(XO SHOWN) ANCHOR REQUIREMENT INSTALLED IN EITHER FIXED PANEL OR NOTES ANCHORS,SEELIP& EXTERI OR OR DIRECTION. �����Q��ILY(1JIV 1)DETAILS APPLY TO 2,3 AND 4 TRACK CONFIGURATIONS. REINFORCEMENT TYPES(SEE NOTE 6,THIS SHEET) DETAIL SHEET 19 ALL PARTS IDENTICAL. �` �� ••L.CENg'' �1' 2)REFER TO ANCHOR NOTES,SHEET 1. FORALL LOCKSTILES,3)SEE SHEET 13 FOR ANCHOR LOCATION$SPACING,FOR ASTRAGALS,F1XE0 ANCHOR QUANTITIES,SEE TABLES 1&2. STILES AN a VINYL SLIDING GLASS DOOR NOA(LM) 10/05/15 =tr:' No.58705 D 0 4)CONTINUOUS ANCHOR PLATE,ITEM#8,IS REQUIRED AT ALL HORIZONTAL RAILS 2zs INSTALLATION,HORIZONTAL X-SECT. m J ROSOWSKI —� ' �U FRAME ANCHOR LOCATIONS. O aTE F , -� 5)PANEL WIDTH DOES NOT INCLUDE INTERLOCK OR ASTRAGAL ADD ON / 6)SEE TABLES 1&2 FOR REINFORCEMENT REQUIREMENTS.ALL FOR I B)NO CHANGES THIS SHEET. .03123/20 'i�� F<ORIDP,..•-N REINFORCEMENTS ARE APPROXIMATELY THE FULL LENGTH OF INTERLOCKS/7` 27 za iSS� NAL ����` ONLY 1070 TECHNOLOGY DR � //1/1",I I l I \\ THE EXTRUSION.REFER TO TEST REPORTS FOR EXACT DIMENSIONS. N.VENICE,FL 34275 7)SEE SHEET 20 FOR SCREEN DETAILS, srarlDaRD HD (941)480-1600 rjLSG,-,,70jjj NTS 1"13 OF 21 MD-5570.0 c B A LYNN MILLER,RE REGISTRATION 029286 a P.Ei158705 DETAIL E1 TYP.ANCHOR TYPE,EMBEDMENT DETAIL E2 DETAIL E3 DETAIL E4 INTO MAsoNRY AND EDGE DISTANCE PER INTO WOOD INTO MASONRY INTO METAL DADE APPROVED MULLION,FBC 1X BUCKSTRIP SUBSTRATE,SEE TABLE A,SHEET COMPLIANT ALUMINUMISTEEL 1&NOTE 3,THIS SHEET 2X WOOD BUCKSTRIP OR TYP ANCHOR TYPE,EMBEDMENT FRAMING OR STEEL STUD.MAY FRAMING,SEE ANCHOR CONCRETE/CMU EDGE AND EDGE DISTANCE PER CONCRETEICMU PER BE VERTICAL OR HORIZONTAL. NOTE 3,SHEET 1 PER ANCHOR DISTANCE SUBSTRATE,SEE TABLE A,SHEET ANCHOR REQUIREMENT SEE SUBSTRATE PROPERTIES, REQUIREMENT EDGE 1&NOTE 3,THIS SHEET EDGE TABLE A,SHEET 1 ' DISTANCE DISTANCE EMBED- •• EDGE DISTANCE a MENT EMBEDMENT ° EMBEDMENT EMBEDMENT 114"MAX. e n iX OR 2X WOOD nn 1/4"MAX. 9 �1/4"MAX. 9 �1/4'MAX. 1 9 Q so BUCKS TRIP,SEE Q CJ ANCHOR NOTE 3, 9 TYP.ANCHOR TYPE,EMBEDMENT AND TYP.ANCHOR TYPE,EMBEDMENT AND / ea SHEET 1 9 EDGE DISTANCE PER SUBSTRATE,SEE EDGE DISTANCE PER SUBSTRATE;SEE / TABLE A,SHEET 1&NOTE 3,THIS SHEET TABLE A,SHEET 1&NOTE 3,THIS SHEET 9 9G 33 NOTES FOR 1)DETAILS APPLY TO 2,3 AND 4 TRACK CONFIGURATIONS. LA CKSTILE ASTRAGALS,S, 2)REFER TO ANCHOR NOTES,SHEET 1. FIXED STILES 3)SEE SHEETS 11&12 FOR ANCHOR LOCATION&SPACING, AND #8 X 3/4"SMS REINFORCEMENT FOR ANCHOR QUANTITIES,SEE TABLES 1&2. DLO WIDTH=NOM.PANEL WIDTH-8-9/16" HORIZONTAL SCREW,3 PER RAIL,LOCATED AT 4)CONTINUOUS ANCHOR PLATE,ITEM#8,IS REQUIRED AT DLO HEIGHT=DOOR HEIGHT-11-1/16" ANCHOR PLATE AT RAILS EVERY ANCHOR CENTERLINE AND 9"FROM ENDS ALL FRAME ANCHOR LOCATIONS. PANEL HEIGHT=DOOR HEIGHT-2-112" LOCATION (FACTORY INSTALLED) 5)SEE SHEET 20 FOR SCREEN DETAILS. DAYLIGHT z5 6)SEE TABLES 1&2 FOR REINFORCEMENT REQUIREMENTS. OPENING PANEL ALL REINFORCEMENTS ARE APPROXIMATELY THE FULL FRAME SEE HEIGHT LENGTH OF THE EXTRUSION.REFER TO TEST REPORTS FOR HEIGHT HEIGHT NOTES, SILL RISER 'PRODUCT REVISED THIS SHEET VARIES WITH EXACT DIMENSIONS. .as complying with the Florida REQUIRED Bullding Code NOA-No. 20.0429.05 EXTERIOR POSITIVE Expiration Date-0 411 4/2 0 21 DESIGN z9 a PRESSURE, .390—•-1 1-+ By;_15 -Z r.[,....� ez sz 91 OR SEE SHEETS .390—r I I-�- Miami-Dade Product Control EXTERIOR 7&8. .390 -1 1-- z9 — a Y9 OR 390 2.3� 2.947 1/4"MAX. as #42 SHOWN 1.7193 4.041 GROUT AS 9 4z #43-45 ALSO APPLY .823 Lui-a 7 3.464 NEEDED,SEE 1.917 ANCHOR NOTE 1a so 0 060 .060 — 060 5,SHEET 1 9 Q z 12 P 2-1/2"=TOTAL .060—_+_— ED 1/4"MAX. 9 8 SILL HEIGHT SILL RISER SILL RISER SILL RISER SILL RISER 42(2-1/2"TOTAL 4a (3-112"TOTAL 44 (4-1116"TOTAL 45 (4-518"TOTAL ,` � {NN SILL HEIGHT) SILL HEIGHT) SILL HEIGHT) SILL HEIGHT) \:`1�N.OENSc?1��( EMBED- ,'`; .' E EMBEDMENT EDGE MENT (STANCE VINYL SLIDING GLASS DOOR NOA(LM) 10/05/15 No.58705 •. i:= EDGE TYP.ANCHOR TYPE, TYP.ANCHOR TYPE, INSTALLATION,VERTICAL X-SECT. - J ROSOWSKI _ DISTANCE EMBEDMENTAND 2X WOOD BUCKSTRIP OR EMBEDMENTANDj�G_T �f0 TAT E41:� 0 ��/` EDGE DISTANCE FRAMING,SEE ANCHOR EDGE DISTANCE B)NO CHANGES THIS SHEET. x� 03/23120 " T.�''.,FtOR1OP.•' -\��` CONCRETEICMU PER SUBSTRATE, NOTE 3,SHEET 1 PER SUBSTRATE, '��s •••....... PERANCHOR DETAILF1 SEETABLEA, DETAILF2 SEE TABLE A, 1070 TECH ,OPL013YD �� /'/ 91ONAL�C�` REQUIREMENT SHEET 1&NOTE 3, SHEET 1&NOTE 3, 3,275 INTO MASONRY INTO WOOD (941)-480-1600 ® A.LYNN MILLER,P.E. THIS SHEET THIS SHEET REGISTRATION p2B299 S SGD-5570 NTS 4 OF 21 cg MD-5570.0 A� 13 p.E#58705 4 71 P�O�OIo tb-- INTERIOR 35 O 71 19 ((44)THRU KEEPER 9 - INTERIOR 25 OR 28 25 OR 28 37 98 MAX 18.5"O.C. INTERIOR 33 Be 98 SEE SHEET 19 + DETAIL H2 8 INTERIOR98 (4)THRU KEEPER Q MAXoEXTOR3.B'O.C.,SEE SHEET 19so° 69 u 33 INTERIOR Q 94 OR 8.5"O.C. -Duo 25 OR 28 ❑� EXTERIOR EXTERIOR D D 41 IIIIId, v 135° O V 90° 33 39 � c DETAIL G1 \ DETAIL HII MAX 18.5"O.C.94 �0 90° d INSIDE CORNER OO INSIDE CORNER 40 EXTERIOR C�J INTERIOR 41 �� (4)THRU KEEPER B9 EXTERIOR 98 Qa MAX 3.5"O.C., 1 SEE SHEET 19 19 O 2 O o PRODUCT REVISED as complyyi1ngg Buil ding Cod with the Florida e NOA-No. 20-0429.05 �OO 135° 4 Expiration Date:0411412021 -- INTERIOR By:_1L -2 I•Z/—n 111IamHDade Product Control NOTES q o 1)DETAILS APPLY TO 2,3 AND 4 TRACK CONFIGURATIONS. 2)SEE SHEETS 14&15 FOR ANCHOR LOCATION&SPACING,FOR ANCHOR 25 OR 26 OD QUANTITIES,SEE TABLES 1&2. �`�`� Y LYN 33 38 - 3)CORNER ASTRAGAL MAY BE EITHER TO THE INTERIOR OR EXTERIOR, \�` ON.......!�41 35 DEPENDING ON CONFIGURATION. �_�•'•��c-N$F �!!� d MAX 18.5"O.C.68 NO.58705 +9 69 VINYL SLIDING GLASS DOOR NOA(LM) A 10/05/15 (4)THRU KEEPER @ MAX 9a EXTERIOR —'� '• 3.5"O.C.,SEE SHEET 19 *DETAIL G2 nV CORNER ASTRAGAL HORIZ.X SECT. m J ROSOWSKI �0; tAqTEF�� (V 135° '•F.OR10P..•'•..\��. OUTSIDE CORNER 1070 TECHNOLOGY DR B)NO CHANGES THIS SHEET. m 03I23/20 S�O1JAI N.VENICE,FL 34275 (941)-460-1600 SGD-5570 NTS � 5 OF 21 0 MD-5570.0 B a LYNN MILLER,P.E REGISTRATION p29208 y RE.fl 58705 DETAIL 11 DETAIL 12 OPTIONAL NOW STRUCTURAL INTO MASONRY INTO MASONRY ANCHORS FOR EDGE t �o CONCRETEICMU Q tl INTERIOR POCKET 21 INTERIOR TYP.ANCHOR TYPE,EMBEDMENT DISTANCEPER ANCHOR REQUIREMENT JAMB ,' 33 91 2 z7 AND EDGE DISTANCE PER SEE FIG 1, SUBSTRATE,SEE TABLE A, INTERIOR POCKETS MUST 30 FIGURE I,INTERLOCKS AT POCKETS: INCLUDE A NON-STRUCTURAL, THIS SHEET ml SHEET 1 8 NOTE 3,BELOW :.'w..'; (: `'' FOR DOOR HEIGHTS 96"AND LESS: FRAME JAMB TO REDUCE THE 10 ' POSSIBILITY OF WATER ". :.. OPT. e INFILTRATION. 21 `=, . .�• ANCHOR 31 �q 104"MAX. 19 EMBEDMENT POCKET BY OTHERS,SEE 17 OPT y, t t '• 17 OPT. NOTE 6 BELOW. s d .. :EIVTBEp: y MENT'.:"' OPT EXTERIOR pq o FOR DOOR HEIGHTS OVER 96" 1/4"MAX. I] 21.9" ANCHOR 10 e7 MAX.O.C. SEE G I TYP.ANCHOR TYPE,EMBEDMENT' ExrERIOR CONCRETE/CMU THIS SHEET ET 31 `� 30 q AND EDGE DISTANCE PER nn EDGE PER ANCHOR 26 R z7 SUBSTRATE,SEE TABLE A,SHEET 1 V DISTANCE REQUIREMENT d &NOTE 3,BELOW INTERIOR POCKET EXTERIOR POCKET zz 91 21 TYP.ANCHOR TYPE,EMBEDMENT METAL TYP.,SEE ANCHOR NOTE AND EDGE DISTANCE PER 4,SHEET 1;ANCHOR LENGTH TO SUBSTRATE,SEE TABLE A,SHEET 1 BE A MIN.OF 3 THREADS BEYOND &NOTE 3,BELOPRODUCT REVISED 2X WOOD BUCKSTRIP OR THE METAL SUBSTRATE EDGE as eomplyln with the Florida DISTANCE FRAMING,SEE ANCHOR Dalldine Core EDGE NOTE 3,SHEET 1 NOA-No. 20-0429.05 DISTANCE OPT.ANCHOR Expiration Data:04/1412021 DETAIL 13 OPT.ANCHOR INTO METAL. EMBEDMENT By:_1 s-Z I.L/,+., 17 OPT. 0 17 OPT. Mlami-Bade Product Contra] EMBEDMENT 1/4„ J ppp��� o DETAIL 14 1/4"MAX. o MAX. INTO wood �I EXTERIOR to a SEE FIG 1, 9 e d THIS SHEET 31 SEE FIG 1, c� THIS SHEET 30 29 R 27 EXTERIOR 22 fl 21 91 17 \Ill]lllll/� EXTERIOR POCKET EXTERIOR POCKET !1Jle1�' NOTES VINYL SLIDING GLASS DOOR NOA(LM) 10105/15 _x� : No.53705 1)DETAILS APPLY TO 2,3 AND 4 TRACK CONFIGURATIONS.2)REFER TO ANCHOR NOTES,SHEET 1, P-HOOK EXAMPLES,HORIZ.X-SECT. m` J ROSOWSKI = /� <L 3 SEE SHEET 13 FOR ANCHOR LOCATION&SPACING,FOR ANCHOR QUANTITIES,SEE TABLES 1&2. ® i STATE of 4)SEE TABLES 1&2 FOR REINFORCEMENT REQUIREMENTS. a B)NO CHANGES THIS SHEET. z� 03/23/20 ��T�'•,,FC OR{iJ?•.•"U� 5)INTERIOR OR EXTERIOR POCKETS APPLICABLE FOR ALL INSTALLATION METHODS. 1070 TECHNOLOGY DR 6)POCKET WALL OR CAVITY IS NOT PART OF THIS APPROVAL AND IS TO BE DESIGNED BY OTHERS N.VENICE,FL 34275 _ ��I I' I 11\\\ AND REVIEWED BY THE AUTHORITY HAVING JURISDICTION. (941)-480-1600 SGD-5570 NTS 6 OF 21 k MD-5570.0 � B A LYp,E#59795 P E REGISTRATION429266 TABLE 1; Design Pressure(DP)and Anchor Quantities Required, (fir all approved configurations on Sheet 2) Use this table for: Door Unit Height ANCHORAGE TYPE PER SUBSTRATE REQUIRED TO ACHIEVE THE DESIGN PRESSURE,USING THE ANCHOR QUANTIES LISTED BELOW.SEE TABLE A, Glass Types 1,`IA,3 or3A BEV 96" SHEET 1 FOR COMPLETE ANCHOR LIMITATIONS. Astragal Reinforcement 429 68-15116"DLO Height 72-15/16"DLO Height 84-15/16"DLO Height THE MAXIMUM DP AT THESE ANCHOR QUANTITIES.ADDITIONALLY,THE Lockstile Reinforcement 025 or#26 Anchor Group Anchor Group Anchor Group MAXIMUM POSITIVE DP DUE TO THE SILL HEIGHT MUST ALSO BE Std.Interlock Reinforcement#27 A 8 C D A 13 1 C i D A B C D CONSIDERED,SEE TABLE B1,THIS SHEET. Design Pressure +60/-60 psf +601-60 psf +60/-60 psf #OF ANCHORS THROUGH THE HEAD&SILL.(EX:FOR C3+1,3 ANCHORS 163I8" Head/Sill C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 CLUSTERED AT PANEL MEETING POINT AND 1 ANCHOR REQUIRED AT 24" DLO Jamb P-hook 7 7 5 5 5 5 7 7 7 7 8 8 8 8 5 5 5 5 5 5 5 5 MIDSPAN OF PANEL). W ldth TOTAL#OF ANCHORS THROUGH THE JAMB. 7 7 Design Pressure +60/-60 psf +601-60 psf +60/-60 psf THE#OF ANCHORS REQUIRED THROUGH THE P-HOOK, 22-5/8" Head/Sill C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 PERPENDICULAR TO THE GLASS. 30" DLO Jamb 5 5 5 5 5 5 5 5 5 5 5 5 L Width g P-hook 7 7 7 7 7 7 7 7 8 1 8 1 8 18 i Design Pressure +60 f-60 psf +60/-60 psf +60/-60 psf ' 28-516" Head/Sill C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+i C3+1 C3+1 C3+1 C3+1 C3+1 PRODUCT REVISED o_ 36" DLO Jamb 5 5 5 5 5 5 5 5 5 5 5 5 Width as comp Ing with the Florida � P-hook 7 7 7 7 7 7 7 7 8 8 8 8 Building ode NOA No. 20.0429.05 a Design Pressure +60/-60 psf +601-60 psf +601-60 psf Expiration Date:(1411412021 34-518" Head/Sill C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 42" DLO TABLE 81: gy_1 wZ r•�i„a Width Jamb 5 5 5 5 5 5 5 5 5 5 5 5 Water-Limited Mla: mF-Dade Product control G 1 P-hook T 7 7 7 T T 7 7 FI 8 8 8 8 (+)Design Pressure OH LENGTH Design Pressure +60/-60 psf +601-60psf +60l-60 psf Sill Nom.Sill Max.(+)DP 40-5/B" HeadiSill C3+2 C3+1 C3+1 C3+1 C3+2 C3+1P7T 3+1 C5+2 C3+1 C3+1 C3+1 Riser Height Allowed DOOR ASSEMBLIES 48" DLO Jamb 5 5 5 5 5 55 5 5 6 5 INSTALLED WHERE THE Width None 1-11/16" See Note 2 P-hook 7 7 7 7 7 77 8 8 8 e 42 2-1/2" +38.7 psf = OVERHANG(OH)LENGTH EQUAL 70 OR GREATER THAN 43 3-1/2" +60.0 psf p THE OVERHANG HEIGHT IS USED IN EXAMPLE ON SHEET 9 44 ¢1fi6" t60.0 psf EXEMPTED FROM WATER 45 4-5/6" +60.0 psf INFILTRATION RESISTANCE. DLO WIDTH=NOM.PANEL WIDTH-7-3/8" HEIGHTDLO PANEL EIGHTDOD OREHEGHT-12`1/2" N � 11V LYN ..........Ali TABLE NOTES: �`•••• �1G6rJSF -.11F �, VINYL SLIDING GLASS DOOR NOA LM 10/05/15 1)IF WATER INFILTRATION RESISTANCE IS REQUIRED,THE LESSER VALUES OF EITHER TABLE 1 AND TABLE 131 DETERMINES THE WATER LIMITED(+)DP. DP&ANCHOR QUANTITY TABLE 4 J ROSOWSKI ;-C 2)IF WATER INFILTRATION RESISTANCE IS NOT REQUIRED OR OVERHANG IS PER FIG i,A SILL ® t� RISER IS NOT REQUIRED.IF SO,+DP'S SHOWN IN TABLE 1 MAY BE USED. B)CORRECTED DLO WIDTH, z� 03123120 '��v ""TE ��•' 3)SEE SILL RISER TYPES ON SHEET 4. ;F'S'•::f or Iol,•'��_� 4)SHEET APPLIES TO 2,3 AND 4 TRACK CONFIGURATIONS. 1070 TECHNOLOGY 5 a `S/OIVAL.�N 5)REFER TO ANCHOR NOTES,SHEET 1. N.VENICE,FL 34275 6)SEE SHEETS 11-16 FOR ANCHOR LOCATION&SPACING (941)-460-1600 SGD-5570 NTS 7 OF 21 MD-5570.0 B A L�r�j MILIEtR P,E REGISTRATION 029296 O P,E.IS Sfl765 TABLE 2: Design Pressure(DP)and Anchor Quantities Required, (for all appro%ed configurations an Sheet 2) ANCHORAGE TYPE PER SUBSTRATE REQUIRED TO ACHIEVE THE DESIGN Use this table for. Door Unit Height PRESSURE,USING THE ANCHOR QUANTIES LISTED BELOW.SEE TABLE A, Glass Types 2 or 4 80" 84" 96" 108" 120" SHEET 1 FOR COMPLETE ANCHOR LIMITATIONS. Astragal Reinforcement#29 68-15/16"DLO Height 72-15116"DLO Height 84-15116"DLO Height 96-15/16"DLO Height 1 08-1 511 6"DLO Height THE MAXIMUM DP AT THESE ANCHOR QUANTITIES.ADDITIONALLY,THE Lockstile Reinforcement#25 Anchor Group Anchor Group Anchor Group Anchor Group Anchor Group MAXIMUM POSITIVE DP DUE TO THE SILL HEIGHT MUST ALSO BE CONSIDERED,SEE TABLE B2,THIS SHEET. HD Interlock Reinforcement#28 A I B I C I D A I B I C I D A I B C D A B I C I D Aj B C D Design Pressure +100/400 psi +100/-100 psf +100/-100 psf +60/-65 psf +60/-65ps( #OF ANCHORS THROUGH THE HEAD&SILL.(EX:FOR C3+1,3 ANCHORS 16-5/8�� CLUSTERED AT PANEL MEETING POINT AND 1 ANCHOR REQUIRED AT 24" DLO Head/Sill C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C5+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 C3+1 MIDSPAN OF PANEL). Width Jamb 5 1 5 1 5 1 5 5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 TOTAL#OF ANCHORS THROUGH THE JAMB. P-hook 7 1 7 1 7 1 7 7 7 1 7 1 7 8 8 8 8 9 9 9 9 10 10 10 10 THE#OF ANCHORS REQUIRED THROUGH THE P-HOOK, Design Pressure +100/-100psf +100/-100psf +100/-100psf +60/-65Psi` +60/-65psf PERPENDICULAR TO THE GLASS. 22-5/8' Head/Sill C5+1 C3+1 C3+1 C3+1 C5+1 C3+1 I C3+1 I C3+1 C5+1 C3+1 C5+1 C3+1 C3+1 C3+1 C3+1 C3+1 C5+1 I C3+1 C3+1 1 C3+1 PRODUCT REVISED 30" DLO as compylng with the Florida Width Jamb 5 5 5 5 5 5 6 5 5 5 7 5 6 6 6 6 6 6 6 6 Buliding Coda P-hook 7 7 7 7 7 7 7 7 8 8 6 e 9 9 9 9 10 10 10 10 NOA-No. 20-0429.05 Design Pressure +100/-100psf +100/400psf +100/-100psf +60/-65psf +60/-65psf Expiration Data:04/1412021 26-5/8" FIG 1: gy;-_115-2 r.Z/,. Head/Sill C5+2 C3+1 C5+1 C3+1 C5+2 C3+1 C5+1 C3+1 C5+2 C5+1 C5+1 C3+1 C5+1 C3+1 C3+1 C3+1 C5+1 C3+1 C5+1 C3+1 OH LENGTH 36" DLO Jamb 5 5 6 5 5 5 6 5 5 5 7 5 6 6 6 6 6 6 6 6 Mlamt-Dade Product control Width v P-hook 7 7 7 7 7 7 7 7 8 8 8 8 9 9 9 9 10 10 10 10 F- DOORASSEMBLIES Design Pressure +100/-100 ps( +100/-100 psf +100/-100 psf +60/-65 psf +60/-65 psf INSTALLED WHERE THE c 34 5/8" Head/Sill C5+2 C3+2 C5+2 C3+1 C5+2 C5+2 C5+2 C3+1 C5+2 C5+2 C5+2 C3+1 C5+1 C3+1 C5+1 C3+1 C5+1 C5+1 C5+1 C3+1 W OVERHANG(OH)LENGTH IS 0- 42" DLO Jamb 5 5 7 5 5 5 7 5 5 5 8 5 6 6 6 6 6 6 7 6 = EQUAL TO OR GREATER THAN Width p THE OVERHANG HEIGHT IS P-hook 7 7 7 7 7 7 7 7 6 B B 8 9 9 9 9 10 10 10 10 EXEMPTED FROM WATER E Design Pressure +100/-f00psf +100/400psf +92/-92 psf' +60/-65psf +60/-65ps( INFILTRATION RESISTANCE. z 40-5/8" Head/Sill C5+2 C5+2 C5+2 C3+2 C5+2 C5+2 C5+2 C3+2 C5+2 C5+2 C5+2 C5+2 C5+2 C3+1 C5+2 C3+1 C5+2 C5+1 C5+2 C3+1 48" DLO Width Jamb 5 5 7 5 5 5 8 5 5 5 9 5 6 6 7 6 6 6 8 6 P-hook 7 7 7 7 7 7 8 8 8 1 8 9 9 9 9 9 9 10 10 10 10 TABLE 62: Design Pressure +80/-80psf +60/-80psf +80/-80PSI` +60165ps( +54.1/-58.7psf Water-Limited 46-5/8 Head/Sill C5+2 C3+2 C5+2 C3+2 C5+2 C3+2 C5+2 C3+2 C5+2 C5+2 C5+2 C3+2 C5+2 C5+2 C5+2 C5+2 C5+2 C5+2 C5+2 CS+2 (+)Design Pressure 54" DLO Width Jamb 5 5 6 1 5 5 5 7 1 5 5 1 5 81 5 6 6 8 6 6 6 1 8 1 6 Sill Nom.Sill Max.(+)DP P-hook 7 7 7 1 7 7 7 7 1 7 8 1 8 8 18 9 9 9 9 10 10 1 10 1 10 Riser Height Allowed Design Pressure +80/-80psf - +80/-80psf +80/-80psf +59.1/-64psf +49.6/-53.7 psf None 1-11/16" See Note 2 52-5/8" Head/SIII C5+3 C3+2 C5+3 C3+2 C5+3 C3+2 C5+3 C3+2 C5+3 C5+2 C5+3 C3+2 C5+2 C5+2 C5+2 C5+2 C5+2 C5+2 C5+2 C5+2 42 2-1/2" +38.7 psf 60" DLO Width Jamb 5 1 5 1 6 5 5 5 1 7 5 5 1 5 8 5 6 6 8 6 6 6 8 6 43 3.1/2" +60.0 psf P-hook 1 7 7 7 7 7 7 7 1 7 1 8 1 8 8 8 9 9 9 9 10 10 10 10 44 4-1/16" +80.0 psf +/-100.0 PSF FOR ANCHOR GROUPS B,C&D. 45 4-5/8" +100.0 psf DLO WIDTH=NOM.PANEL WIDTH-7-3/8" DLO HEIGHT=DOOR HEIGHT-11-1/16" y LY/V PANEL HEIGHT=DOOR HEIGHT-2-1/2" .` ��\O�......••N2/� .c•,.•'•�,\CENSC•'•�� TABLE NOTES: �r: VINYL SLIDING GLASS DOOR NOA(LM) d 10/05/15 _ No.58705 1)IF WATER INFILTRATION RESISTANCE IS REQUIRED,THE LESSER VALUES OF EITHER TABLE 2 AND TABLE B2 DETERMINES THE WATER LIMITED(+)DP. DP&ANCHOR QUANTITY TABLE 1 a J ROSOWSKI �() ;ram` 2)IF WATER INFILTRATION RESISTANCE IS NOT REQUIRED OR OVERHANG IS PER FIG 1,A SILL ® S �O�. TAPE OF RISER IS NOT REQUIRED.IF SO,+DP'S SHOWN IN TABLE 2 MAY BE USED. B)CORRECTED DLO WIDTH. a 03/23/203)SEE SILL ''•. (ortloP.•'-\�: 4)SHEET APPILIES TO TYPESSER ,3 AND 4 TRACK CONFIGURATIONS, 1070 TECHNOLOGY DR �$ / ' ZOIVAL 5)REFER TO ANCHOR NOTES,SHEET 1. N.VENICE,FL 34275 _ 6)SEE SHEETS 11-16 FOR ANCHOR LOCATION&SPACING (941)ABO-1600 SGD-5570 NTS 8 OF 21 o z MD-5570.0 B A LYNN MILLER,P.E. REGISTRATION N29296 ¢9 P.E.056705 EXAMPLE: Q 3-PANEL,3 TRACK,STRAIGHT CONFIGURATION-PXXX, FRAME JAMB REQUIRED HEAD SPLICE INTERIOR CENTERLINE CENTERLINE SEE FIGURE BELOW FOR ADDITIONAL INTERIOR MOUNT POCKET,48"X 84"NOM.PANELS, @ INTERIOR POCKETS OF INTERLOCK OF INTERLOCK ANCHOR INFORMATION. 6" CENTERLINE CENTERLINE CENTERLINE LAMINATED,IG GLAZING,ANCHOR GROUP A IN WOOD SUBSTRATE, MAX. OF PANEL 1 OF PANEL OF PANEL PROJECT DESIGN PRESSURE REQUIRED:+48.21-58.6 PSF POCKET BY OTHERS,SEE NOTE 6, SHEETS '+2" 25-3/8"MAX. 6" "+2"ANCHORAGE, ANCHORAGE, SHEETI2 "+2"ANCHORAGE, MAX. 6"MAX. SHEET 12 SHEET 12 "C3"CLUSTER, "13"CLUSTER, EXTERIOR SHEET 12 SHEET 12 END ANCHORAGE SEE POCKET JAMB (MIN.1 ANCHOR) li EXTERIOR SPLICE NOTE: INSTALLATIONON HEAD ANCHORAGE DETAILS OPT.ANCHOR � NONSTRUCTURAL ANCHORS MAY SHEET PXXX(3-TRACK) TO AID IN BE ADDED IN-FIELD AS NEEDED TO 4 ALIGNMENT ALIGN THE HEAD OR SILL IF SPLICE OCCURS WITHIN A POCKET. SILL SPLICE INTERIOR CENTERLINE CENTERLINE SEE FIGURE BELOW FOR ADDITIONAL Ir—OF INTERLOCK OF INTERLOCK ANCHOR INFORMATION. 6" CENTERLINE I CENTERLINE CENTERLINE MAX. OF PANEL 1 OF PANEL 2 OF PANEL 3 POCKETBY 0 o o - EXTERIOR INTERIOR OTHERS,SEE NOTES. 0 0 0 0 0 0 SHEET 6 25-3/8"MAX. 6- ANCHORAGE, "+2"ANCHORAGE, "+2"ANCHORAGE, MAX. SHEETII SHEET11 SHEETII "C3"CLUSTER, °C3"CLUSTER, EXTERIOR SHEET 11 SHEET 11 END ANCHORAGE 12"MAX. 216" FRAME JAMB SEE POCKET JAMB (MIN.1 ANCHOR) ri MAX• REQUIRED@ INSTALLATIONON SILL ANCHORAGE DETAILS O.C. INTERIOR POCKETS SHEET6 1)KNOWING THE PRODUCTS REQUIREMENTS,SCAN THROUGH TABLES 1&2 PXXX(3-TRACK) PRODUCT REVISED ea compI�Ing with the Florida FOR A DESIGN PRESSURE THAT MEETS OR EXCEEDS THE REQUIREMENT OF Du11dInB aodD +48.2/-58.6.AT A NOM.PANEL SIZE OF 48"X 841.FROM TABLE 1,SHEET 7,THE END PANEL ANCHOR EXCEPTION: NOA-No. 20-0429.05 DESIGN PRESSURE IS+601-60 WHICH EXCEEDS THE PROJECTDESIGN Expiration Date-04114120211 PRESSURE REQUIREMENTS. DISTANCE TO NEXT CLUSTER 1 s— TO BE 25-3I8"O.C.OR LESS By:_ Z Mlumt-Dade Product Control FOR WOOD INSTALLATION USING ANY I Heed/Sill C3+2 ANCHOR IN GROUP A(SEE TABLE A),TABLE Jamb 5 1 SHOWS ANCHOR REQUIREMENTS OF: P-hook 7 2)ANCHOR LOCATION DETAILS,CAN BE FOUND ON: CENTERLINE OF END PANEL 6"MAX. HEAD(CLUSTER ANCHORS):SHEET 12 FOR THE"CT'CLUSTER ANCHORS AT 6 THE INTERLOCWASTRAGAL. FOR SILL(SHOWN)AND HEAD,ANCHORS ATTHE OPT.ANCHOR TO AID IN HEAD(INTERMEDIATE ANCHORS):SHEET 12 FOR THE"+2 ANCHORS AT THE MIDPOINT OF END PANELS ARE ONLY REQUIRED IF THE ALIGNMENT MIDSPAN OF EACH PANEL. O.C.DISTANCE TO THE NEXT ANCHOR CLUSTER IS OVER P-HOOK JAMB SILL(CLUSTER ANCHORS):SHEET 11 FOR THE"C3"CLUSTER ANCHORS AT 25-3/8",OTHERWISE ANCHORS ARE NOT REQUIRED AS 11'YILI I r�� THE INTERLOCK/ASTRAGAL. PER THE FIGURE ABOVE: ANCHORAGE ANCHORAGE SILL(INTERMEDIATE ANCHORS):SHEET 11 FOR THE"+2 ANCHORS AT THE N�cPN-F DETAILS DETAILS MIDSPAN OF EACH PANEL. Q �� JAMB:5 ANCHORS,SHEET 13 FOR GEN.LAYOUT. VINYL SLIDING GLASS DOOR NOA(LM) 10/05/15 Wo.SB7D5 FOR PRODUCT REFERENCES,ALSO SEE: P-HOOK:7 ANCHORS,SHEET 13 FOR GENERAL A)SHEET 2 FOR ALLOWABLE CONFIGURATIONS AND EXACT LAYOUT. STRAIGHT DOOR EXAMPLE m J ROSOWSKI U ',Uu/ ;L6 G LOCATIONS OF CROSS-SECTION DRAWINGS, J?nT. O�. STATE F B)SHEET 10 FOR SPECIFIC GLAZING TYPES. 3)INSTALLATION DETAILS INTO WOOD CAN B)NO CHANGES THIS SHEET. kM 03/23/20 �p . F40R1Dp C)SHEET 17 FOR ALLOWABLE PANEL TYPES AND CALL NAMES. BE FOUND ON: D)SHEETS 4&18 FOR EXTRUSION CROSS-SECTION DRAWINGS. HEAD&SILL:SHEET 4 1070 TECHNOLOGY DR E SHEET 19 FOR INSTALLATION OF ADDITIONAL ACCESSORIES. N.VENICE,FL 34275 JAMB:SHEET 3 A.LYNN MILLER,P.E. F)SHEET 21 FOR A BILL OF MATERIALS. P-HOOK:SHEET 6 R 941�8ON#292� SGD-5570 NTS 9 OF 21 MD-5570.0 $ B p,E.#58705 1-1116"NOM. 3/16"HS GLASS 7/16"NOM. 7116"NOM. 7/16"NOM. 3/16"HS GLASS 3116"HS GLASS I 3116"HS GLASS 3/16"ANN GLASS 7s 7e .090"PVB .090"PVB .090"SG 7/16"AIR SPACE n 7e 3/16"ANN GLASS PAINTED/ 3/16"HS GLASS PAINTED/ W6"HS GLASS 3116"T GLASS PAINTED/ PAINTED/ LAMINATED LAMINATED LAMINATED Bo OR 81 SURFACE BO OR al SURFACE e6 OR 81 LAMINATED 82 OR 83 _ SURFACE SURFACE O O O aEXTERIOR I- -- a EXTERIOR I- -- � a EXTERIOR I- -- � a EXTERIOR � PRODUCT IS"EXTERIOR- I \I PRODUCT IS"EXTERIOR- I \1 PRODUCT IS"EXTERIOR- I \I PRODUCT IS"EXTERIOR- I \I GLAZED"IF#80-81 IS 7/8"NOM. GLAZED"IF#80-81 IS 7/8"NOM. GLAZED"IF 00-81 IS W8"NOM. GLAZED"IF#82-8315 7/8"NOM. TOWARDS THE EXTERIOR.I I GLASS TOWARDS THE EXTERIOR.I I GLASS TOWARDS THE EXTERIOR.I I GLASS TOWARDS THE EXTERIOR.I I GLASS I I BITE I I BITE I I SITE I I BITE INTERIOR I a INTERIOR I a INTERIOR I a INTERIOR I PRODUCT IS"INTERIOR- I I PRODUCT IS"INTERIOR- I I PRODUCT IS"INTERIOR- I I PRODUCT IS"INTERIOR- GLAZED" I I TORDS THE INT IS ERIOR. i 79 GLAZED"IF TOWARDS THE IN IS TERIOR. i 79 GLAZED"IF#80-81 IS TOWARD THE INTERIOR. i 79 TOWARDS"IFTHE INTERIOR. I 2-83 IS 79 85 86 85 Be SEE NOTE 2, SEE NOTE 2, SEE NOTE 2, SEE NOTE 2, THIS SHEET THIS SHEET THIS SHEET THIS SHEET GLASS TYPE 1 GLASS TYPE 1A GLASS TYPE 2 GLASS TYPE 3 "ANN"=ANNEALED "HS"=HEAT STRENGTHENED "T"=TEMPERED SILICONE STRUCTURAL HOT-MELT BUTYL 1-1116"NOM. 1-1/16"NOM. 'PVB"=.090"TROSIFOLO PVB INTERLAYER. SILICONE 3116"HS GLASS 3/16"HS GLASS BY KURARAY AMERICA,INC. STRUCTURAL 3116"NOM. 0g0"Pve oso"SG "SG"=.090"SENTRYGLASO INTERLAYER POLYISOBUTYLENE 1/4"NOM. FOAM _ WITH DESICCANT WITH 3/16"HS GLASS 76 76 3116"HS GLASS 75 76 BY KURARAY AMERICA,INC. DESICCANT EXT.GLASS EXT.GLASS 7/16"AIR SPACE 77 78 7/16'AIR SPACE T7 7B 3116"T GLASS 3116"T GLASS PRODUCT REVISED PAINTED/ PAINTED/ as comp Ingg with tho Florida LAMINATED LAMINATED Building�odo B2 OR 63 a2 OR 89 NOA-No. 20-0429.05 SURFACE SURFACE INT.GLASS INT.GLASS <D EXTERIOR a EXTERIOR i F�cpirnOon Dale:0411412021 PRODUCT IS"EXTERIOR- I \I PRODUCT IS"EXTERIOR- I By:_1.-.2 1.L—" GLAZED"IF#8'T". 7/8"NOM. GLAZED"IF#82-83IS I 7/8"NOM. Miami-Dade Product Control KODISPACE SUPER TOWARDS THE EXTERIOR.I D I GLA ES TOWARDS THE EXTERIOR.i I GLEES 76 4SG TPS 76 SPACER®NXTT" I I a INTERIOR I INTERIORALUM I I " INTERIOR- REINFORCEMENT GLAZED"IF 82.83 INUM PRODUCT IS S I I 79 GLAZED"IF#82-8PRODUCT IS T3 ISOR UTYLE 0. DESICCANT FILL AREA I I I 79 TOWARDS THE INTERIOR. TOWARDS THE INTERIOR. I BUTYSEFNAL 5/16"NOM. I BUTYL SILICONE SEAL SEE NOTE 2, SEE NOTE 2,DESICCROLL-FORMED THIS SHEET THIS SHEETAINLESS STEEL GLASS TYPE 3A GLASS TYPE 4Ly N .,: o�a�...... M, FEXT.GLAS NOTES: � �,1GL"NXEXT.GLASS 1)BACKBEDDING SURFACES SHALLIJa.58705NOT BE PAINTED OR LAMINATED. VINYL SLIDING GLASS DOOR NOA(LM) d10/05/16 ASS INT.GLASS 2)PRODUCT MAY BE EITHER GLAZING DETAILS l m J ROSOWSKI '•,� H yZ Zp •:441 INTERIOR OR EXTERIOR GLAZED, ® lz �O�., STaTE F [V. DURASEALP XL EDGET" PROVIDED THAT THE"HS"SURFACE c B)NO CHANGES THIS SHEET. 03/23/20 �C '•.;<oRlo?.- -ti�: rr 7B OF A LAMINATED GLAZING UNIT IS ''7�S/ANAL�\N SPACER SPACER ADHERED TO THE GLAZING LEG. 1070 TECHNOLOGY DR $� � N.VENICE,FL34275 rI J/I 1I111111\ (941)-480-1600 SGD-5570 NTS 111 10OF21 24 MD-5570.0 J# B ALYPE#805PE REGISTRATION#29298 SILL CLUSTER ANCHORS LAYOUT: SILL"+"INTERMEDIATE ANCHORS LAYOUT: ASTRAGAL OR ASTRAGAL OR PANEL INTERLOCK INTERLOCK PANEL_ CENTERLINE PANEL CENTERLINE 4„ CENTERLINE 4" CENTERLINE CENTERLINE 4" 4" o EXTERIOR EXTERIOR EXTERIOR EXTERIOR EXTERIOR • 2-TRACK CLUSTER'C3' 2-TRACK CLUSTER"C5" 2-TRACK INTERMEDIATE 2-TRACK INTERMEDIATE 2-TRACK INTERMEDIATE ANCHOR LOCATIONS ANCHOR LOCATIONS ••+1"ANCHOR LOCATION '+2'ANCHOR LOCATIONS '+3"ANCHOR LOCATIONS ASTRAGAL OR ASTRAGAL OR PANEL INTERLOCK INTERLOCK PANEL PANEL .CENTERLINE CENTERLINE 4'' CENTERLINE 4" CENTERLINE CENTERLINE 4" 4„ 0 EXTERIOR I 3.22 EXTERIOR 3.22 EXTERRIDR EXTERIOR 3.22" EXTERIOR —�•-I 3.22" 3-7RACK CLUSTER"C3' I;ul 3-TRACK CLUSTER"C5' v 3-TRACK INTERMEDIATE V 3-TRACK INTERMEDIATE v 3-TRACK INTERMEDIATE ANCHOR LOCATIONS ANCHOR LOCATIONS "+1"ANCHOR LOCATION '+2"ANCHOR LOCATIONS '+3"ANCHOR LOCATIONS , ASTRAGAL OR ASTRAGAL OR PANEL PANEL PANEL INTERLOCK INTERLOCK— CENTERLINE CENTERLINE CENTERLINE CENTERLINE 4" CENTERLINE 4" 4" 0 0 EXTEE�IRIIOR 3.22" EXTERIOR 3.22" EXTERIOR EXT�EE"IRIIOR EXTI RIIOR EXT�TE�RyIOR 3.22" v 4-TRACK CLUSTER v 4-TRACK CLUSTER 4 TRACK INTERMEDIATE `� 4-TRACK INTERMEDIATE 4-TRACK INTERMEDIATE "C3"ANCHOR LOCATIONS 'C5'ANCHOR LOCATIONS '+1"ANCHOR LOCATION "+2"ANCHOR LOCATIONS '+3"ANCHOR LOCATIONS NOTES: FIGURES PERTAW TO THE FOLLOWING SILL 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. NOTES: INTERMEDIATE ANCHOR LOCATIONS: 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED, 2)TRACK-TO-TRACKIS2.375" 5" DISTANCE IS 2.375" 2)TRACK-TO-TRACK FOR ALL SILLS: DISTANCE IS 2.375" W2.375" FOR ALL SILLS: PRODUCT nCing with the Florida 1 Buildipl9oe ', . ,I.I(..I LI.I.I.I. ;P VDEI`IS FJa 5 NOA-No. 20-0429.05 Ph Expiration Data:04/14/2021FIGURES PERTAIN TO THE FOLLOWWG SILL ok Iv I�IL G�(t� ••.��� CLUSTER ANCHOR LOCATIONS: !;�• nn N0.58705 VINYL SLIDING GLASS DOOR NOA(LM) g 10/05/15 By:—1 —.2ade product Control -_ �/I J �_ r —,J ANCHOR LOCATIONS A qe JROSOWSKI �?,�., srnrE r ��� ® B)NO CHANGES THIS SHEET. a 03/23/20 j�2r %�s 'F��?...... C. ��'"S"ONAL 00? ' Head/Sill C3 1 1070 TECHNOLOGY DR � II I I I I I I II Jamb 5 N.VENICE,FL 34275 Phook 7 (941)-480-1600 SGD-5570 NTS 11OF21 MD-5570.0 z° B ALYNN"LLER,.P.E. P.E.115 705 REGISTRATIONN29296 HEAD CLUSTER ANCHORS LAYOUT: HEAD"+"INTERMEDIATE ANCHORS LAYOUT: ASTRAGAL OR ASTRAGAL OR PANEL PANEL_ INTERLOCK q" INTERLOCK q" PANEL CENTERLINE 4" CENTERLINE 4" CENTERLINE CENTERLINE CENTERLINE EXTERIOR 3,22" EXTERIOR 1 1 3,22" EXTERIOR EXT�ERI,IOR 3.22" EXTERIOR 2-TRACK CLUSTER"C3" 2-TRACK CLUSTER'C5 2-TRACK INTERMEDIATE 2-TRACK INTERMEDIATE V 2-TRACK INTERMEDIATE ANCHOR LOCATIONS ANCHOR LOCATIONS "01 ANCHOR LOCATION '+2'ANCHOR LOCATIONS '+3"ANCHOR LOCATIONS ASTRAGAL OR ASTRAGAL OR PANEL PANEL PANEL INTERLOCK INTERLOCK— CENTERLINE CENTERLINE 4„ CENTERLINE q„ CENTERLINE— CENTERLINE 4 75" 4° EXTERIOR 3.22" EXTERIOR 3.22" EXTERIOR EXTERIOR EXTERIOR ID 3-TRACK CLU ,TRACK INTERMEDIATE STER"C3" 3-TRACK INTERMEDIATE 2�Iy 3-TRACK INTERMEDIATE 3 ANCHOR LOCATIONS 3-TRACK CLUSTER v/ `+l"ANCHOR LOCATION v "+2"ANCHOR LOCATIONS ANCHOR LOCATIONS ANCHOR LOCATIONS ASTRAGAL OR ASTRAGAL OR PANEL PANEL PANEL INTERLOCK INTERLOCK—�- 4" CENTERLINE CENTERLINE CENTERUNE 4 CENTERLINE 4� CENTERLINE EXTERIOR 3.22" EXTERIOR 3.22 EXTEE7RIIOR EXTERIOR EXTERIOR 3.22" 15- 4-TRACK CLUSTER v 4-TRACK CLUSTER 4+Tj"AANCHOR CK LOCATION 4 T�ANMEDIATE 15CHORCK ELROCATION5+2" ¢T ANCHOR LOCATIONS"+3' 'C3"ANCHOR LOCATIONS "C5"ANCHOR LOCATIONS NOTES: FIGURES PERTAIN TO THE FOLLOWING HEAD 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. IHiERMEDIATE ANCHOR LOCATIONS: NOTES: 2)TRACK-TO-TRACK 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. DISTANCE IS 2.375" EW2375" FOR ALL HEADS: 2)TRACK-TO-TRACK D(STANCE IS 2.375" J2.375.1 FOR ALL HEADS: PRODUCT REVISED 1y �tll 11 11 ffff HJad)Sill 1 Bn1lding Bong with the Florida0�.� FIGURES PERTAW TO THE FOLLOWING HEAD Jamb $ NOMNO. tl 20-0429�06 ��y,��•••ttGENS• CLUSTERANC THE LOCATIONS: P-hook 7 F ••,��{��� Expiration Data:04/14/2021 Q=;" •,•� NO.58705 ' VINYL SLIDING GLASS DOOR NOA(LM) 10/05/15 MIam1 Dade Product Control ANCHOR LOCATIONS B Vim` J ROSOWSKI =�A'•, 91AI 41= F: l ` B)NO CHANGES THIS SHEET. �d 03/23/20 FS,' a ORIOI.. Head/Sill C3 1 1070 TECHNOLOGY DR �1VAL IE `` Jamb 5 N.VENICE,FL 34275 P-hook 7 941-460-1600 0.LYNN MILLER,RE � ) SGD-5570 NTS 12 OF 21 0� MD-5570.0 �� B P,E.#se7as REGISTRATION fi2929a FIGURES PERTAIN TO THE FOLLOWING JAMB ANCHOR LOCATIONS: P-HOOK ANCHORS LAYOUT: JAMB ANCHORS LAYOUT, (PARTIAL VIEW): —� r— 2.375" —►1 r— 4.75" r--� 7.125" 6" MAX. 21.6" 21.6" 21.6" Head/Sill C3+1 Jamb 5 MAX. MAX. MAX. P-hook 7 O.C. EXTERIOR O.C. EXTERIOR O.C. EXTERIOR OPT.ANCHOR TO AID IN NOTES: ALIGNMENT 1)STANDARD ANCHOR LOCATIONS SHOWN. FOR 3 AND 4-TRACK JAMBS,ANCHORS MAY BE LOCATED IN ANY ADJACENT TRACK 6" fi" 6" (SIMILAR TO THE 2 TRACK JAMB)AS MAX. MAX. MAX. REQUIRED TO MEET MIN.EDGE DISTANCE I 2-TRACK FRAME 3-TRACK FRAME I 4-TRACK FRAME CONSTRAINTS.IN CASE H M ODD JAMB ANCHORS JAMB ANCHORS JAMB ANCHORS NUMBER OF ANCHORS,THE MAJORITY MAY BE TOWARD THE INTERIOR OR EXTERIOR. 12" MAX. JAMB JAMB JAMB (3)WEEP NOTCHES (4)WEEP NOTCHES (5)WEEP NOTCHES PER END @ 1"X.500'! PER END @ 1"X.500" PER END @ 1"X.500" I I- \V'm' SILL \ SILL SILL EXTERIOR EXTERIOR EXTERIOR (3)TRACK WEEP HOLES 6"MAX. EVERY 24"@ 1.125"X.190';1\ (6)TRACK WEEP HOLES\` (10)TRACK WEEP HOLES \ OPT.ANCHOR (1)WEEP NOTCH EVERY EVERY 24"@ 1.125"X.190"; EVERY 24"@ 1.125"X.190';- TO AID IN 24"@ 1.375"X.500" (1)WEEP NOTCH EVERY (1)WEEP NOTCH EVERY ALIGNMENT 24'@ 1.375"X.500" 24"@ 1.375"X.500" NOTES: 1)SEE TABLES 1&2 FOR EXACT QUANTITY SILL WEEPHOLE LAYOUT(2,3&4 TRACKS) PRODUCT REVISED' `�YI �INN/ OF ANCHORS REQUIRED IN THE P-HOOK. B lding Cod with the Florida `�� LY'' Building Code ��,,'�•-• �•10Etd �: � FIGURES PERTAIN TO THE FOING POCKET JAMB HDA-No. 20-0429.05 S• •�� R=;' P•HOOK ANCHOR LOCLLOWATIONS: Expiration Date:04/14/2021 y NO.55705 L/—"I�IA7 I.VINYL SLIDING GLASS DOOR NOA(LM) 10l05115 By,_ = ' MIamHDedo Product Control —� � �J/ •: cYi ANCHOR LOCATIONS Ca J ROSOWSKI �O�.• s ATE ai rc B)NO CHANGES THIS SHEET. 03/23/20S/ONgL I �v\? .� fill vHead/SIII c3+1 1070 TECHNOLOGY DR Jamb 5 N.VENICE,FL 34275 P-hook 7 941 480-1600 A LYNN MILLER.P.E ( ) SGD-5570 NTS 13OF21 MD-5570.0 6£ B p.E.#58705 REGISTRATION 929295 i i FIGURES PERTAIN TO THE P HEAD 90°CORNER CLUSTER ANCHORS LAYOUT: SILL 90°CORNER CLUSTER ANCHORS LAYOUT: FOLLOWWG PD,CORNER SILL ANCHOR LOCATIONS: 90° 4" >4" 4" >4° 4" 4" 4" 4" u HeadlSlll 1 3.22 EXTERIOR 3,22 EXTERIOR ° Jamb 5 2-TRACK 90'CORNER 2-TRACK 90'CORNER P-hook 7 . "C4"ANCHOR LOCATIONS 'C6'ANCHOR LOCATIONS 15 2-TRACK SO'CORNER EXTERIOR 2-TRACK 90'CORNER EXTERIOR (USE WHERE"C3"IS SPECIFIED) (USE WHERE"C5"IS SPECIFIED) "C4"ANCHOR LOCATIONS ---�7 'C6"ANCHOR LOCATIONS n (USE WHERE'C3'IS SPECIFIED) �/ (USE WHERE'CS'IS SPECIFIED) �J 4" q" PRODUCT REVISED4„ &3. But ding Cndewith the Florida NOA-No. 20.0429.05 c Expiration Date.04/14/2021 4„ 4" 4, Miami-Dade Product Control EXTERIOR ERIOR 3.22" 3-TRACK 90°CORNER 3-TRACK 90'CORNER I�1 3-TRACK 90°CORNER EXTERIOR 3-TRACK GO' CORNER EXTERIOR "C4"ANCHORLOCATIONS "C6"ANCHOR LOCATIONS v ^04"ANCHOR LOCATIONS r y "C6"ANCHORLOCATIONS (USE WHERE'C3'IS SPECIFIED) (USE WHERE"C5"IS SPECIFIED) (USE WHERE'CT'IS SPECIFIED) v (USE WHERE"C5"IS SPECIFIED) 4" 4,. 4„ 4" a%�Y..... 4" 4„ 4" u = � N0.58705 3.22 S \ 4" _l EXTERIOR EXTERIOR EXTERIOR 3.�n EXTERIOR /�7�15j/�1VA(- \\��\\ 4-TRACK 90'CORNER 4-TRACK SW CORNER -RACK 90°CORNER 4-TRACK OW CORNER n 1 j I I I I I I I "C4"ANCHOR LOCATIONS 'CO"ANCHOR LOCATIONS "C4"ANCHOR LOCATIONS °C6"ANCHOR LOCATIONS �J (USE WHERE"C3"IS SPECIFIED) (USE WHERE'C5"IS SPECIFIED) (USE WHERE'CS'IS SPECIFIED) (USE WHERE'CS"IS SPECIFIED) A.LYNN MILLER,P.E. .P.E.#58705 NOTES: FIGURES PERTAINTO THE FOLLOWING W CORNER 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. HEAD ANCHOR LOCATIONS: VINYL SLIDING GLASS DOOR NOA(LM) S 10/05/15 90° 2)DETAILS DEPICTANCHOR QUANTITY AND SPACING,AND WOULD BE ANCHOR LOCATIONS Dm J ROSOWSKI SIMILAR FOR OUTSIDE(SHOWN)AND INSIDE CORNER CONFIGURATIONS. db HeadlSlll C 1 Jamb 5 3)TRACK-TO-TRACK B)NO CHANGES THIS SHEET. a 03/23/20 P-hook 7 DISTANCE IS 2.375" 2.375" 2.375" $ 1070 FOR ALL HEADS AND SILLS: N.ENICE,,FLO R 4275 $ (941)-480-1800 REGISTRATION N26--- SGD-5570 I NTS 1 140E 21 11 MD-5570.0 8 HEAD 135' CORNER CLUSTER ANCHORS LAYOUT: SILL 135'CORNER CLUSTER ANCHORS LAYOUT: FOLLOWING 9Y CORNE SILL ANCHOR LOCATIONS: 135° �� 4. 4„ 4„ 4„ 0 � f 4„ o HeadfSlll C31 TERIOR 3 22„ EXTERIOR EXTERIOR EXTERIOR P hook 7 Cn} 13 4" 4„ 2-TRACK 135'CORNER 2-TRACK 135°CORNER 2-TRACK 135'CORNER 2-TRACK 135'CORNER V "C4'ANCHOR LOCATIONS 'C6"ANCHOR LOCATIONS "'ANCHOR LOCATIONS "C6'ANCHOR LOCATIONS (USE WHERE"C3"IS SPECIFIED) (USE WHERE"C5"IS SPECIFIED) (USE WHERE"C3'IS SPECIFIED) (USE WHERE'C5"IS SPECIFIED) X", 4„ 4„ 4„ 4° 4„ PRODUCT REVISED 4„ as complying with the Florida Dullding Code NOA-No. 20-0429.05 4„ Expiration Date:04/1412021 EXTERIOR EXTERIOR EXTERIOR EXTIE"R�IOR gy;_1c1.-2hG/,.,.>•. f-L 3•�„ 3,22„ V MIamHDade Product Control 3-TRACK 135°CORNER V 3-TRACK 135°CORNER 3-TRACK 135'CORNER 3-TRACK 135'CORNER "Ce ANCHOR LOCATIONS CV ANCHOR LOCATIONS "C4"ANCHOR LOCATIONS °C6"ANCHOR LOCATIONS (USE WHERE"C3°IS SPECIFIED) (USE WHERE"C5"IS SPECIFIED) (USE WHERE"C3'IS SPECIFIED) (USE WHERE'C5"IS SPECIFIED) 4 4„ 4, 4„ > `�Y LYIUN& cerasF �EEIXTE�RIOR " 4° No.58705 EXTERIOR %�O •• 7SA4TIE , EXTERIOR I-I EXTERIOR n 3 22„ 1 y �i ^'COF'101^ 4-TRACK 135'CORNER �/ 4-TRACK 135°CORNER v 4-TRACK 135'CORNER `J 4 TRACK 135'CORNERS/O 'C4"ANCHOR LOCATIONS 'C6"ANCHOR LOCATIONS °C4'ANCHOR LOCATIONS 'C6"ANCHOR LOCATIONS //1,0111 NAL j 111� (USE WHERE"CS'IS SPECIFIED) (USE WHERE°C5"IS SPECIFIED) (USE WHERE"C3"IS SPECIFIED) (USE WHERE"C5°IS SPECIFIED) A.LYNN MILLER,P.E. P.E#56705 NOTES: FIGURES PERTAIN TO THE FOLLOWING 136'CORNER 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. HEAD ANCHOR LOCATIONS: " VINYL SLIDING GLASS DOOR NOA(LM) IMI 10/05/16 135' 2)DETAILS DEPICT ANCHOR QUANTITY AND SPACING,AND WOULD BE SIMILAR FOR OUTSIDE(SHOWN)AND INSIDE CORNER CONFIGURATIONS. ANCHOR LOCATIONS E � J ROSOWSKI Head/Sill C31 Jamb 5 3)TRACK-TO-TRACK � B)NO CHANGES THIS SHEET. a�03123120 P-hook 7 DISTANCE IS 2.375" E 2,375" 2.375" 1070 TECHNOLOGY DR �� FOR ALL HEADS AND SILLS: N.VENICE,FL 34275 841-480-1600 ( ) SGD-5570 NTS 15 OF 21 �i MD-5570.0 B REGISTRATION p292Bfi HEAD SPLICE ANCHORS LAYOUT @ INTERLOCK OR ASTRAGAL:_ SILL SPLICE ANCHORS LAYOUT @ INTERLOCK OR ASTRAGAL: F'SricEDs¢�ANNce RLOC TONSS::G SPLICE SPLICE SPLICE SPLICE LOCATION 4" LOCATION 4„ LOCATION LOCATION 4" 4" EXTERIOR 3 22 EXTERIOR 3,22 EXTERIOR EXTERIOR Head/Sill C3 1 n I-1 ID ANCHORLOCAE � "C5"ANTCHHOR LOCATIONS '.mb RACK SPLICE 5 `7 2-TRACK SPLICE `J 2-TRACK SPLICE �/ •C4°ANCHOR LOCATIONS P-h00k 7 "C4"ANCHOR LOCATIONS "CV ANCHOR LOCATIONS (USE WHERE-Cr IS SPECIFIED) (USE WHERE"C5"IS SPECIFIED) (USE WHERE•C3"IS SPECIFIED) (USE WHERE"C5"IS SPECIFIED) SPLICE SPLICE SPLICE LOCATION 4,75" SPLICE LOCATION 4„ LOCATION 4" LOCATION 4" PRODUCT REVISED as complying with the Florida EXTERIOR 4" EXTERIOR 3.22" EXTERIOR 3.22" EXTERIOR 4" Building Code rL 3-TRACK SPLICE 3-TRACK SPLICE J� ANCHORJ-1 RACK SPLICE ANCHO-TRACK SPLICE NOA No. 20-0429.05 °C4"ANCHOR LOCATIONS "C6•ANCHOR LOCATIONS v 'E WHERE LOCATIONS 15 °CWANCHORLOCATIONS (USE WHERE•C3"IS SPECIFIED) (USE WHERE"C5°IS SPECIFIED) (USE WHERE"C3"IS SPECIFIED) (USE WHERE"C5"IS SPECIFIED) Expiration Date.04N4/2021 By:_I u--Z 1.Ll...,y Mlamt-Dade Product Control SPLICE 4.75" SPLICE SPLICE SPLICE LOCATION LOCATION 4" LOCATION LOCATION 4" 0 . \III 1 1111�� EXTERIOR 4„ EXTERIOR, 3.22" EXTERIOR 3.22" EXTIE�IRIOR 3,22" �� \+� I_YIJiv ///// 4-TRACK SPLICE v 4-TRACK SPLICE 4-TRACK SPLICE r y 4-TRACK SPLICE ��,���•''\µ•Lh' /� v / "C4"ANCHOR LOCATIONS °C6'ANCHOR LOCATIONS "C4"ANCHOR LOCATIONS "CS"ANCHOR LOCATIONS (USE WHERE"CW IS SPECIFIED) (USE WHERE"C5•IS SPECIFIED) y '. (USE WHERE"C3"IS SPECIFIED) (USE WHERE"C5"IS SPECIFIED) _,h I'J0.58705 t- O •.• TATE p �4tj�� NOTES: 1)ALL DIMENSIONS SHOWN ARE BASED ON MINIMUM ALLOWED. /"'0 011 , FIGURES PERTAIN TO THE FOLLOWING SPLICED 2)ABOVE FIGURES ARE FOR SPLICES OCCURRING AT THE ASTRAGAL OR INTERLOCK. A.LYNN MILLER,P.E. HEAD ANCHOR LOCATIONS: FOR SPLICES OCCURRING INSIDE OF A POCKET,SEE THE EXAMPLE ON SHEET 9. REN 58705 3)TRACK-TO-TRACK VINYL SLIDING GLASS DOOR NOA(LM) 10/05/15 DISTANCE IS 2.375" 2.375 2.376" j�JT — FOR ALL HEADS AND SILLS: ANCHOR LOCATIONS F Im J ROSOWSKI ® B)NO CHANGES THIS SHEET. Ha03/23/20 4)POCKET WALL OR CAVITY IS NOT PART OF THIS APPROVAL AND IS TO BE DESIGNED 8Y OTHERS AND REVIEWED BY THE AUTHORITY HAVING JURISDICTION. 1070 TECHNOLOGY DR Head/Slll C3 1 zg N.VENICE,FL 34275 Jamb 7 (941)-480-1600 SGD-5570 NTS 16OF21 04 MDP-hDo -5570.0 �� B REGISTRATION gri798 PANEL'S RIGHT STILE TYPE SCREEN PANEL TYPES PANEL OUTSIDE 90' INSIDE 9D° OUTSIDE 135' INSIDE 135' DOUBLE ASTRAGAL TYPES SINGLE SINGLE FIXED LOCKSTILE ASTRAGAL ASTRAGAL ASTRAGAL ASTRAGAL ASTRAGAL ASTRAGAL C INTERLOCK INT �1nnw�.L INTERLOCK INTERLOCK STILE W1 HANDLE BOX OUT BOX IN RECEIVER RECEIVER RECEIVER RECEIVER INTERIOR OR OUT IN M DOUBLE EXTERIOR GLAZED LOCKSTILE IBC] INTERLOCK SINGLE F PP K L L TC TA TV TW '""`""""�""� ASTRAGAL INTERLOCK J LOCKSTILE OUT paxou0 (saxs) SINGLE O P A /� ^ C� /1 C V DOUBLE S w SD INTERLOINGLECK INTERLOCK INTERLOCK B v V LJ /'y V Y Y LU IN lsoxolm (Baxev) DOUBLE a FIXED R [� S C F( - Fp FV FW A INTERLOCK LOCKSTILE R STILE I (1 V V I (eoxolm (saxwl LLJ LOHANDLE D M U ASTRAGAL �wwvw+i_.+ LOCKSTILE J J, DOUBLE SINGLE AS DS INTERLOCK INTERLOCK BOOUT LO T fsaxa00ffioxom LU ASTRAGAL BOX IN N OKIN (soxam) OUTASTRAGAL CT CS CF LU ASTRAGAL Z RECEIVER IN,90' Q ASTRAGAL F a' RECEIVER AT AS D" PRODUCT REVISED as complying with the Florida OUT. Ilding ASTRAIGAL VT VS VF NOA-No.Codo 20-0429.05 RECEIVER Ezpiratlon Dato:04114/2021 IN.RECEIVER 1/1/T WS WF ASTRAGAL 1/1/ By:_1.-7 1•ZA—s RECEIVER Miami-Dade Product Control LEFT RIGHT PANEL PANEL STILE e STILE PANEL TYPE "F"SHOWN. PANEL NOTES: '` 1\11111(11V(T,' l SEEDP/ANCHOR TABLES 1&2,SHEETS 7-8 FOR PANEL SIZES&DESIGN PRESSURE. :\ ���'�cENSF 2)PANEL TYPES NOT SHOWN ARE NOT REQUIRED FOR ANY CONFIGURATIONS AND ARE VINYL SLIDING GLASS DOOR NOA(LM) 10/05/15 _ No.53'705 ' NOTAVAILABLE. - I` r PANEL TYPES J ROSOWSKI _ D: G' 3)MAXIMUM NOMINAL PANEL WIDTH FOR ALL PANEL CONFIGURATIONS IS 60". ® L/ B)CORRECTED"E"PANEL TYPE NAME. 'A 03/23/20 %�� •, R .• 4)PANEL TYPE MAY BE EITHER EXTERIOR(STANDARD)OR INTERIOR GLAZED,BOTH SS •••• TYPES QUALIFIED BY THIS APPROVAL,SEE DETAILS SHEET 10. 1070 TECHNOLOGY DR � N.VENICE,FL34275 ���/�IOI�IAL .`E. (941)-480-1600 SGD-5570 NTS111 17 OF 21 MD-5570.0 �$ B A.LY1 1�I1 LLdR,P.E. P.EN 58705 REGISTRATION IY19298 291 061 762 5.875 -� 10.635 540 .125r'-.550 C� pl INTERLOCK CAP, .100 9 500 930ri .100 2 dQ®H"R���-�® ®� 1.661 062 .301 jp 1.928 �- 7OCOVER{PVC)FRAME W ®ANCHOR PLATE Q TRACK INSERT 10 EXTENDED POCKET 5.178 iO 2 TRACK HEADIJAMB © 4 TRACK SILL 1.000 252 ffl.613 31 .060 2.060 .100 8.250 j 8250 �1 t 1.435� .062 T .080 p 949 1.9B3 El El O 3 I O o.100 �oII Il 6y 1 ���".062 .060 .100 dQ®�-�� Lnl�'�l + 11 BOTTOM RAIL 12 OUTER COVER SILL 13 COVER SILL ACK 17 P-HOOK ADAPTOR 18 P-HOOK SUPPO 3 TRACK HEADMAMB ®3 TRACK SILL 229 .094 125 540 291 .061 2.975 2.141 � 10.625 5.876 540 rI�3.00 0 v--�r, .075 �--�R� .626 .500 [+ 1+2.607_41 1.406 � � �u I o.100 p �� --41--.062 -►11�-.062 329 1.613 p ��pII 1.681 n.100 d�Cn� LeJ� 19 KEEPERED KEEPER BAR GOVERMENT O BAR REINFORCEMENT 0 FIXED PANEL CLIP ®ELATE RCEMENT O5 4 TRACK HEADMAMB (2)2 TRACK SILL 2.511 a I.-2.838 -�{ 1.570 1.625 -.{ 1.595 r 1.595 r 309 2.696 .080 2.EFF-09 9 3.483 .125 .070 .075 4.635 4.279 .100 2.833 2.368 2.768 .400A 2.768 2 0'25 .312 2.210 .090 2.116 1 .300 l q ❑ 34.INTERIOR JAMB COVER - 4I+-.188 �I -2.710 1.875 �- PRODUCT REVISED 110 Imo- 4-, '1 .182 .120 11.182 2.291 .100 as complyln with the Florida Q TOP,BOTTOM TOP,BOTTOM INTERLOCK.3D0 INTERLOCK.400 ASTRAGAL EXTENDED POCKET INTERLOCK PANEL STILE,TOP Building Cote AND STILE © AND STILE REINFORCEMENT, ®REINFORCEMENT, REINFORCEMENT 30 INTERLOCK ADAPTER 31 ADAPTER 32 ASTRAGAL ADD-ON 33 AND BOTTOM RAIL Expirrattlon Date:04114 2021 REINFORCEMENT COMPOSITE STANDARD HEAVY-DUTY REINFORCEMENT gy_I c-Z 3.326 r-3.345 NOTES: MlamHDade Product Control 3.452- 1,472 919 1)SEE SHEET 4 FOR 125 3.209 125 O60 3.713 •090 SILL RISERS. 3.345 �,060 2 175 .046 1.500 3.247 I 2)SEE SHEET 20 070 -1 1 .085 F_ .919 FOR SCREEN PARTS. 1.170 .229 !- 300 3 ALL DIMENSIONS 135°CORNER 135°CORNER 135°CORNER 135°CORNER 90°CORNER 90°CORNER 90°CORNER ) ASTRAGAL 36 PASSIVE MOUNT 37 ASTRAGAL CAP, 38 ASTRAGAL CAP, 39 ASTRAGAL 40 ASTRAGAL CAP, 41 INTERIOR CAP IN INCHES. ``\"Q�,IIIL;I,� � -►1.912 912 .210 252-►�1.261 .173 I+ Pc �P }J VINYL SLIDING GLASS DOOR NOA(LM) 10/05/15 ,•;r NG.58%05 _ .065 1.261 .062 1.261 1.261 1.261 0EXTRUSIONSm J ROSOWSKI -� r�` BD SQUARE D 81 BEVELED BEAD 82 BEVELED BEAD 83 OGE D 84 OGEE B)NO CHANGES THIS SHEET. a� 03/23/20 :�/�t` O0 t�l`f; `��` 1070 TECHNOLOGY DR � 7�rIIIIItI�, N.VENICE.FL 34275 (941)-480-1600 SGD-5570 NTS ] 18 OF 21 �e MD-5570.0 B A LY P.E MILLER,P.E..REGISTRATION 429296 .p S8705 1)INSTALL 2)INSTALL CLIP HEADER BLOCK TO HEAD JAMB TO HEAD INTO FRAME JAMB CLIP INTO ATTACHMENT ASSEMBLY (4)CLIP ANCHOR PANEL &SUBSTRATE, HEADER TYPE AS USED ° USING 4 INSTALL ONE BLOCK AT sa BLOCK STILE IN INSTALLATION, INSTALLATION EACH INTERLOCK. Q TABLE A,SHEET 1 ANCHORS,SEE AT ASTRAGAL,INSTALL 93(3)#10 X ° TABLE 1 ONE BLOCK THAT (3)#8 X 1.5"SMS �/� SPANS BOTH PANELS. I 80 1"SMS O as ° d e za FIXED PANEL CLIP \ za FIXED INSTALL ONE CLIP AT THE B5(2)1/4" PANEL MIDSPAN OF EACH FIXED CLIP PANEL-TO-FRAME JAMB LOCATION. X 2-1/4"SMS \ Q #6 X 1"e9 SMS _/ (4)#10 IBAR COVER X 2"SMS22 REINF.BAR #8 X1-1/4"SMSIlk KEEPER is (4)THRU KEEPER @ MAX \�a 3.5"O.C.,SEE SHEET 19 a N,p JAMB TO KEEPER TO JAMB c� SILL ASSEMBLY ATTACHMENT ® \\\ ( LOCKING JAMB d o / PRODUCT REVISED complyingg with the Florida REINFORCEMENT PLATE Bu ❑� as co g Codo ATTACH WITH#8 X 1-1X' 4-PANEL,2-TRACK KEEPER is No"o. 20-0429.0 3 @ 34-1/2"MAX O.C. OXXX SHOWN Expiration Onto:0411412021, 6y' Z ® Miami-Dade Product Control (a)#t0x 2"SMS so INTERLOCK INTERIOR CLIP COVER INTERLOCK NOTES EXTERIOR 24 1)DETAILS APPLY TO 2,3 AND 4 TRACK CONFIGURATIONS. ++ REINF.PLATE 2)SEE SHEETS 11-16 FOR ANCHOR LOCATION&SPACING. \ `�O(aY LYIJIV�f'�i, BOTTOM RAIL °� Ba#10 X 3)SEE TABLES 1&2 FOR REINFORCEMENT REQUIREMENTS. ��•.•'�IGENSF'��( '' SUPPORT 2-1/2"SMS 4)CONTINUOUS ANCHOR PLATE,ITEM#8,IS REQUIRED ATALL FRAME ANCHOR LOCATIONS. Qz•' :�P No.58705 (2)#10 X V SMS VINYL SLIDING GLASS DOOR NOA(LM) a 10/05/15 =:i THROUGH SUPPORT, ez G INTO PANEL f PANEL ACCESSORIES INSTALLATION m ATAIE J ROSOWSKI#10X O . � 'tlx: 1-1/2"SMS ASSEMBLYF1GF.ID�..''-\?� INTERLOCK SILL RETAINER a 8)NO CHANGES THIS SHEETEL CORNERS . 03/23/20 ALL CLIP ATTACHMENT WELDED,OA ASSEMBLY 'a �'SdZONfAl ''���\ 1070 TECHNOLOGY DR � �a INSTALL ONE ASSEMBLY AT EACH INTERLOCK FASTENERS N.VENICE,FL 34275 (941)-480.1600 SGD-557D NTS 19OF21 $ MD-5570.0 zI B ALYNN MILLER,P.E REGMTRATIGNH29296 P.E,#5B7B5 BOX SCREEN DETAILS: STANDARD SCREEN DETAILS: ❑O DORO3 OR 5 ,25 ❑O 106 ^ 1�OR 3OOR 5 0� 121 123 0� 1 102 /./r(1vts1 103 133 132 129 t11 105 i 1t5 HORIZONTAL SECTION HORIZONTAL SECTION EXAMPLE 130 EXAMPLE 115 33 102 111 32 131 l 108 a OOROOR 5 121 PU 171 ® ❑O 1 OROORO o n o� 1 ORO3 ORO 122 100 115 ,�e HORIZONTAL SECTION EXAMPLE 112 � 120 104 HORIZONTAL SECTION 117 1oz EXAMPLE 1.081 1.202-r+�yj 1.778 1.778 ;1135 .875 r. 875-�{ I 1.020 r- -�-�0 .00 50 �i 50 •045 fV I tr} I 12o FRAMESCREEN 121 S DESCRERAIL, 1�ASTRAGAL L EN SCREEN O 1 99 I 1. 1.874 RAIL LATCH ADAPTER jL+-lug-.062 - 41-+-.062 L�.062 PRODUCT REVISED BOX SCREEN BOX SCREEN BOX SCREEN as comp Ing with tho Florida too TOP RAIL 101 BOTTOM RAIL 102 SIDE RAIL 1.435 Bullding M, r-.725 NOA-No. 20-0429.05 iz7 .765 .782 Expiration Date:04l74l2021 _11+ 113 ORS1.020 r-- 1.593 �1 101 1.373 121 120 i ,062 MIamF-Dade Product Control 040 0 2 OROa oR( 1 872 T!� 063 0 129 SCREEN VINYL t24 FRAME SILL .055 2 oROoROs ASTRAGAL SCREEN yj 1.833 ADAPTER ADD-ON 0 L .062 '-'� I+'•372 124 107 [� BOX BOX BOX SCREEN d to3 SCREEN 704 SCREEN 105 OXO INTERLOCK SNAP-ON ASTRAGAL VERTICAL SECTION BUG FLAP ADAPTER EXAMPLE VERTICAL SECTION `�` OS�`; EXAMPLE NOTES: �� ��. �1cCra�.:'•.C�� r050 306343 .055 -"1 1.487 r- 1)ALL DIMENSIONS IN INCHES. 1.487 — _�r; No.5R705� 1.510 060 VINYL SLIDING GLASS DOOR NOA(LM) 10/05/15 �— SCREEN DETAILS J ROSOWSKI � '•, (� 0 • STATE'•• BOX SCREEN BOX SCREEN BOX SCREEN HEAD ® I 105 ASTRAGAL 707 SILL ADD-ON 108 AND JAMB ADD-ON rc B)NO CHANGES THIS SHEET. � 03l23l20 . CAS.•........ ADAPTER 1070 TECHNOLOGY DR /",�i0/0NAL i'�`0" N.VENICE,FL 34275 (941)-480-1600 SGD-5570 NTS A LYNN MLLER,P.E REGISTRATION - . P•E.#68705 TABLE C: TABLE D:BOX SCREEN # Part# Description Material # Part# Description Material # Part# Description Material 1 1 19001 2-Track Head/Jamb Rigid PVC 42 19085 Sill Riser-(2-1/2") 6063-TS Alum. too 12256 Box Screen Top Rail 6063 T5 At 2 1 19002 2-Track Sill Rigid PVC 43 19022A Sill Riser-(31/2") 606346 Alum. 101 12257 Box Screen Bottom Rail 6063 T5 Al 3 1 19026 3-Track Head/Jamb Rigid PVC 44 19023A Sill Riser-(4-1/16") 6063T6 Alum. 102 12258 Box Screen Side Rail 6063 75 At 4 1 19026 3-Track Sill Rigid PVC 45 19024A Sill Riser-(4-5/8") 606YM Alum. 103 64428 Box Screen Interlock 60M T5 At 5 1 19027 4-Track Head/Jamb Rigid PVC 50 718609W. .187"x.320"Finseel(Stile) 104 17347A Box Screen Snepon Bug Flop 6063 T6 Al 6 1 19028 4-Track Sill Rigid PVC 51 71695K 1-117'x 1"x 3/4"Fin Seal Dust Plug 106 64345 Box Screen OXA Astragal Adapter 6063 T6 At 106 17349 Box Screen Astragal Adapter 6063 T5 Al 7 1 19009 IFrame Screw Cover Rigid PVC 52 71696 Dust Plug 107 19039 jBox Screen Frame SIII Add-on 6063 TS Al 8 1 19031 jAnuhcr Plate 6063T6 Alum. 60 419041 Interlock Clip Cover PVC PTI 10038 Box Screen Head/Jamb Add-on 6063 76 Al 9 19007 Track Insert 6063T6 Alum. 61 76153X Tandem Roller Assembly SS 720XiX #14-20 x V MS @ Top Rail SS 10 19084 Interlock Cap-Extended Pocket Rigid PVC 62 78153N Tandem Roller Assembly Nylon 720X112X #14-20 x 1-1/2'MS @ Bottom Rail SS 11 19036 Bottom Rail Support 6063.1E Alum. 63 70X75FPTX #8 x 3/4"Ph.FH SMS @ Roller&Reint SS 71793G Wstp•.27U'x.150'-Fin Seal 12 19006A Outer Sill Cover 6063TB Alum. 64 419042 Frame Header Block Nylon 61805K Wstp,.167'x.500"@ Bug Flap 13 19011 Sill Track Cover Rigid PVC 65 48052 Roller Adj.Hale Plug PVC 78RAZ Standard Roller Nylon 17 19032 P-Hook Adapter 6063-TS Alum. 66 44385 4 Hole Bumper Stop PVC 7SRAX HD Roller Ss 18 19020 P-Hook 6063-TS Alum. 67 76X114FPTX 96 x 1-1/4"Ph.FH SMS @Bumper Stop SS varies Screen Locking Hardware Steel 19 19047M Extended Keeper 6063-TS Alum. 68 71696G Sill Plug PVC 116 419063 Screen Keeper Steel 20 19029M Keeper 6063-TS Alum. 69 78185X Gemini Mortise Lock wllong Trim plate Stasyss 117 76X1PPA #6 x 1"Ph.PH SMS steel 21 19014 Reinforcement Bar Cover Rigid PVC 70 71032XIFPFX 10-32x 1"Ph.FH MS @ Lock SS 118 1692/14 Screen Spline-.150"&.169' Vinyl 22 19030 Reinforcement Bar SODS•T'5 Alum. 71 varies Handle Kit Cast Zino 119 1816C20 Screen Cloth Fibogtass 23 19037M Fixed Panel Gip 6063T6 Alum. 72 19054 Interlock Retainer Clip Nylon TABLE E:STANDARD SCREEN 24 19035M Reinforcement Plate 6063-TGAlum. 75 Kommerling4SGTPS Spacer System See Sheet # Part# Description Material 25 19017M Top Rail,Bottom Roll and Lockstlle 6005-T6 Alum. 76 Quanex Super Spacer nXl'with Hot Melt Butyl 10 for 120 12033 screen Frame Rail 6083 T5 Al 26 19046 Reinforcement Composite 77 Quanex Duraseal Materials 121 12026A Screen Frame-Side Rail(Latch) 6063 T5 At Z7 19018M Interlock.300 Reinforcement,Sid. 6005•75 Alum. 78 Cardinal XL Edge Spacer 122 17363 Screen OXO Astragal Adapter 6053 T6 At 20 19013M Interlock.400 Reinforcement,HD 6005-T5 Alum, 79 Dow 791,983,995 or GE-7700 Backbedding Silicone 123 4853K Screen Vinyl Astragal Adapter Rigid PVC 29 19019M Astragal Reinforcement 6005•T5 Alum. 80 19090 7116"Square Bead Rigid PVC 124 19012B Frame Sill Screen Add-on 6063 T6 At 30 19083 Extended Pocket interlock Adaptor 6063-TS Alum. 81 7116"Beveled Bead Rigid PVC 125 I12PS Bug Flap,85 . 5 duro. Vinyl 31 19005 Interlock Adaptor Rigid PVC 82 19044 1-1/16"Beveled Bead Rigid PVC 127 78X712027 ke x 1-Ke Ph.PH SMS Assembly (Standard) SS 32 19008 Astragal Add-on Rigid PVC 83 19045 1-1116"Ogee Bead Rigid PVC 126 712027 Comer Key Wheel Assembly(Slendard) Nylon 126 712027SS Comer Key Wheel Assembly(HD) SS 33 19004 Panel Stile,Top/Bottom Rail Rigid PVC 84 19016 1-3116"Ogee Bead Rigid PVC 129 varies Screen Locking Hardware Steel 34 1 19040 lintedor Jamb Cover 6063-TB Alum. 85 71725K Setting Block 1/2"x 4"x 1116'.85+/-5 duro. Neoprene 130 710x34PPSDAX #10 x 314"Ph.PH SMS.@ Screen Asl. sS 35 19076 135'Comer Astragal 6063-T6 Alum. 86 71726K Setting Block 1"x 4"x 1/16",85+/-5 duro. Neoprene 131 78X12PPSMSX #8 x 112"Ph.PH SMS @ DoorAst. SS 36 19077 135-Comer Astragal Passive Mount 6063-76 Alum. 90 781 PSTX #8 x 1"Ph.PH SMS @ Frame Assembly Ss 132 1692I3/4 Screen Spline-.145" Vinyl 37 19079 135'Corner Astragal Cap-Ext. Rigid PVC 91 70X114PHPT41OX #8 x 1-1/4"Ph,PH SMS @ Relnt Bar SS 133 1616c20 screen Cloth Fibe glass 38 19080 135'Comer Astragal Cep-int. Rigid PVC 92 710X1PHPT18-8X #10 x 1"Ph.PH SMS @ Rail Support Ss NOTES: 39 19078 90'Comer Astragal 6063T6 Atum. 93 71OX115PPX M0 x 1-1/2"Ph.PH SMS @ Fxd.Pnl.Gip SS 1)ITEMS#14-16,46-49,53-59,73,74&87-89&99 ARE NOT USED AND ARE 40 1 19081 90'Comer Astragal Cap-Ext R g d PVC 94 71OX25PHPT18.BX #10 x 2-1/2"Ph.PH SMS @ Reinf.PlatelAst. SS NOT PART OF THIS APPROVAL. 41 1 19082 90'Comer Astragal Cap-Int. Rigid PVC 95 71420X2.25FPFX #12 x 2-1/4"Ph.PH SMS @ Hdr.Block SS 96 710X1.75PPX #10 x 1-3/4'Ph.FH SMS @ Ast.Mount SS as complying with the Florida wvv O 1Y LYNN Building code N,••..,.. 97 71OX34PPX #10 x 3W'Ph.PH SMS @ Ext.Pkt.Int. SS NOA-No. 20-0429.05 :� t�• iCEly q )��{ TABLE F: a• F ' Material Min.Fy Min.F 98 710X2PPX #10 x 2"Ph.FH SMS @ Keeper SS Expiration Dato:04/74/2021 #12 Steel Screw 92 ksl 120 ksl By,_I s t.C6+" = No.587o5 #12 410 Screw so ksi 110 ksi ViNYL SLIDING GLASS DOOR NOR(LM) B 10/D5/15 MlamHDada Product Control _-D 114"DeWalt/Elco Aggre-Gator® 57 ksi 96 ksl �, X 1/4"Elco UltraCorl® 155 ksi 177 ksi 'PARTS LIST b J ROSOWSKi �O . Tn ��� 1/4"DeWalt UltreCon+® 148 ksi 164 ksi ® �S •F�ORIDP,,• _�C�� 1!4"410 SS DeWaluElco CreteFlex® 127.4 ksi 189.7 ksi B ADDED BCKBDG.TYPES&TABLE F. 03/23/20 ,�'riS7 NAL ��vv 6083-T5 Aluminum 16 ksi 22 ksi 1070 TECHNOLOGY DR ) �10 I I I I t 1�Jv A35 Steel 36 ksl 58 ksi N.VENICE,FL 34275 A.LYNN MILLER,P.E. Gr.33 Steel Stud 33 ksi 45 ksi (941)480-1600 SGD-5570 NTS 21 OF 21 b MD-5570.0 B REGISTRATION g29266 P.E#68706