HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Langel Residence
Builder Name:
Street: 10610 Pine Needle Drive
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34945
Permit Number:
Owner. Langel Residence
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New constriction or existing New (From Plans)
10. Wall Type$2502.7 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 2260.00 ft2
b. Frame - Wood, Adjacent
R=11.0 242.67 ftz
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2540.5 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2419.00 ft2
6. Conditioned floor area above grade (ft2) 2419
b. Knee Wall (Unvented)
R=19.0 121.50 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(296.1 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ft2
6 85
a. U-Factor. Sgl, U=0.32 213.50 ft2
SHGC: SHGC=0.22
b. U-Factor: Sgl, U=0.32 74.58 ft2
13. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.19
a. Central Unit
36.2 SEER:16.00
c. U-Factor. Sgl, U=0.29 8.00 ft2
SHGC: SHGC=0.23
Area Weighted Average Overhang Depth: 4.301 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.213
a. Electric Strip Heat
27.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (2419.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 2419.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
CF. Pstat
Glass/Floor Area: 0.122 Total Proposed Modified Loads: 73.84
PASS
Total Baseline Loads: 74.66
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
r
Code.
calculation indicates compliance
��,;,''% = _ �',;.�� .►+.
with the Florida Energy Code.
ti unr,�+�% `,••�`=';, �O
PREPARED BY:
Before construction is completed
DATE: 1a-28-2021
this building will be inspected for
compliance with Section 553.908
" y
hereby certify that this building, as de ' ned, is in compliance
Florida Statutes.
with the Florida Energy Co
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH60 (R402A.1.2).
6/28/2021 10:35 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Langel Residence
Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2419
Lot #
Owner Name:
Langel Residence
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
10610 Pine Needle Driv
Permit Office:
St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
St. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34945
New/Existing:
New (From Plans)
Comment:
CLIMATE
V
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design
Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2419
22738.6
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
Master Bedroom
312
2932.8 No
2
1
1
Yes
Yes
Yes
2
M WIC 1
50
470 No
0
1
Yes
Yes
Yes
3
M WIC 2
60
564 No
0
1
No
Yes
Yes
4
M Toilet
40
376 No
0
1
Yes
Yes
Yes
5
Master Bath
140
1316 No
1
1
Yes
Yes
Yes
6
Laundry
121
1137.4 No
1
1
Yes
Yes
Yes
7
Hall
45
423 No
0
1
No
Yes
Yes
8
Family
399
3750.6 No
2
1
Yes
Yes
Yes
9
Office
143
1344.2 No
1
1
Yes
Yes
Yes
10
Foyer
72
676.8 No
0
1
Yes
Yes
Yes
11
Dining
156
1466.4 No
2
1
Yes
Yes
Yes
12
Kitchen
252
2368.8 Yes
1
1
Yes
Yes
Yes
13
Bedroom 2
204
1917.6 No
1
1
1
Yes
Yes
Yes
14
WIC 2
28
263.2 No
0
1
Yes
Yes
Yes
15
Toilet
24
225.6 No
0
1
Yes
Yes
Yes
16
Bath 2
78
733.2 No
0
1
No
Yes
Yes
17
Bedroom 3
187
1757.8 No
1
1
1
Yes
Yes
Yes
18
Hall
108
1015.2 No
0
1
No
Yes
Yes
6/28/2021 10:35 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Siab-On-Grade Edge Insulatio
Master Bedroom 45 ft
312 ft2
1
0
0
2 Slab -On -Grade Edge Insulatio
M WIC 1
loft
50 ft2
e
1
0
0
3 Slab -On -Grade Edge Insulatio
M WIC 2
1 ft
60 ft2
1
0
0
4 Slab -On -Grade Edge Insulatio
M Toilet
8 ft
40 ft2
e
1
0
0
5 Slab -On -Grade Edge Insulatio
Master Bath
loft
140 ft2
—
1
0
0
6 Slab -On -Grade Edge Insulatio
Laundry
31 ft
121 ft2
1
0
0
7 Slab -On -Grade Edge Insulatio
Hall 2
1 ft
45 ft2
—
1
0
0
8 Slab -On -Grade Edge Insulatio
Family
19 ft
399 1`12
—
1
0
0
9 Slab -On -Grade Edge Insulatio
Office
15 ft
143 ft2
—
1
0
0
10SIab-On-Grade Edge Insulatio
Foyer
8 It
72 ft2
—
1
0
0
11Slab-On-Grade Edge Insulatio
Dining
16 ft
156 ft2
s
1
0
0
12SIab-On-Grade Edge Insulatio
Kitchen
12 ft
252 ft2
s
1
0
0
13SIab-On-Grade Edge Insulatio
Bedroom 2
41 ft
204 ft2
—
1
0
0
14SIab-On-Grade Edge Insulatio
WIC 2
4 It
28 ft2
r
1
0
0
15SIab-On-Grade Edge Insulatio
Toilet
6 It
24 ft2
—
1
0
0
16SIab-On-Grade Edge Insulatio
Bath 2
1 ft
78 ft2
e
1
0
0
17SIab-On-Grade Edge Insulatio
Bedroom 3
15 ft
187 ft2
1
0
0
18SIab-On-Grade Edge Insulatio
Hall 1
1 ft
108 ft2
e
1
0
0
ROOF
/
Roof
Gable Roof
Rad
Solar SA Emitt
Emitt
Deck
Pitch
V # Type Materials
Area
Area Color
Barr
Absor. Tested
Tested
Insul.
(deg)
1 Hip
Metal 2705 ft2
0 ft2 Light
N
0.6 No 0.9
No
20
26.57
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0 2419 ft2
N N
6/28/2021 10:35 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT 5UMMAKY C HLUKLIS I KtPUK I
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) Master Bedroom 0
Blown
312 ft2
0.1
Wood
2
Under Attic (Unvented) M WIC 1
0
Blown
50 ft2
0.1
Wood
3
Under Attic (Unvented) M WIC 2
0
Blown
60 ft2
0.1
Wood
4
Under Attic (Unvented) M Toilet
0
Blown
40 ft2
0.1
Wood
5
Under Attic (Unvented) Master Bath
0
Blown
140 ft2
0.1
Wood
6
Under Attic (Unvented) Laundry
0
Blown
121 ft2
0.1
Wood
7
Under Attic (Unvented) Hall 2
0
Blown
45 ft2
0.1
Wood
8
Under Attic (Unvented) Family
0
Blown
399 ft2
0.1
Wood
9
Under Attic (Unvented) Office
0
Blown
143 ft2
0.1
Wood
10
Under Attic (Unvented) Foyer
0
Blown
72 ft2
0.1
Wood
11
Under Attic (Unvented) Dining
0
Blown
156 ft2
0.1
Wood
12
Under Attic (Unvented) Kitchen
0
Blown
252 ft2
0.1
Wood
13
Under Attic (Unvented) Bedroom 2
0
Blown
204 ft2
0.1
Wood
14
Under Attic (Unvented) WIC 2
0
Blown
28 ft2
0.1
Wood
15
Under Attic (Unvented) Toilet
0
Blown
24 ft2
0.1
Wood
16
Under Attic (Unvented) Bath 2
0
Blown
78 ft2
0.1
Wood
17
Under Attic (Unvented) Bedroom 3
0
Blown
187 ft2
0.1
Wood
18
Under Attic (Unvented) Hall 1
0
Blown
108 ft2
0.1
Wood
19
Knee Wall (Unvented) Family
19
Batt
82.5 ft2
0.11
Wood
20
Knee Wall (Unvented) Bedroom 3
19
Batt
39 ft2
0.11
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
9
Ornt
Space
TO Wall Type1
N
Exterior Concrete Block - Int InsMaster Bedro
4.1
14
0 9
5
131.8 ft2
0
0
0.3
0
2
E
Exterior Concrete Block - Int InsMaster Bedro
4.1
12
0 9
5
113.0 ft2
0
0
0.3
0
3
W
Exterior Concrete Block - Int InsMaster Bedro
4.1
19
0 9
5
178.9 ft2
0
0
0.3
0
4
W
Exterior Concrete Block - Int Insul M WIC 1
4.1
10
0 9
5
94.2 ft2
0
0
0.3
0
5
W
Exterior Concrete Block - Int Insul M Toilet
4.1
8
0 9
5
75.3 ft2
0
0
0.3
0
6
W
Exterior Concrete Block - Int InstMaster Bath
4.1
10
0 9
5
94.2 ft2
0
0
0.3
0
_ 7
E
Exterior Concrete Block - Int Insul Laundry
4.1
9
0 9
5
84.8 ft2
0
0
0.3
0
8
S
Exterior Concrete Block - Int Insul Laundry
4.1
14
0 9
5
131.8 ft2
0
0
0.3
0
9
W
Exterior Concrete Block - Int Insul Laundry
4.1
8
0 9
5
75.3 ft2
0
0
0.3
0
10
N
Exterior Concrete Block - Int Insul Family
4.1
19
0 9
5
178.9 ft2
0
0
0.3
0
11
E
Exterior Concrete Block - Int Insul Office
4.1
4
0 9
5
37.7 112
0
0
0.3
0
12
S
Exterior Concrete Block - Int Insul Office
4.1
11
0 9
5
103.6 ft2
0
0
0.3
0
_ 13
S
Exterior Concrete Block - Int Insul Foyer
4.1
8
0 9
5
75.3 ft2
0
0
0.3
0
14
S
Exterior Concrete Block - Int Insul Dining
4.1
12
0 9
5
113.0 ft2
0
0
0.3
0
15
W
Exterior Concrete Block - Int Insul Dining
4.1
4
0 9
5
37.7 ft2
0
0
0.3
0
16
N
Exterior Concrete Block - Int Insul Kitchen
4.1
12
0 9
5
113.0 ft2
0
0
0.3
0
17
N
Exterior Concrete Block - Int InsuBedroom 2
4.1
17
0 9
5
160.1 ft2
0
0
0.3
0
18
E
Exterior Concrete Block - Int InsuBedroom 2
4.1
12
0 9
5
113.0 ft2
0
0
0.3
0
19
W
Exterior Concrete Block - Int InsuBedroom 2
4.1
12
0 9
5
113.0 ft2
0
0
0.3
0
20
E
Exterior Concrete Block - Int Insul WIC 2
4.1
4
0 9
5
37.7 ft2
0
0
0.3
0
6/28/2021 10:35 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7
•: u : � � � � I�I1�����li�li�iT17��3:IXa:/���i7�1�7��
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
21
E
Exterior
Concrete Block - Int Insul Toilet
4.1 6
0
9 5
56.5 ft2
0
0
0.3
0
22
E
Exterior
Concrete Block - Int InsuBedroom 3
4.1 15
0
9 5
141.3 ft2
0
0
0.3
0
_23
S
Garage
Frame - Wood
Bedroom 3
11 11
9 4
102.7 ft2
0.23
0.3
0
24
S
Garage
Frame - Wood
Hall 1
11 6
9 4
56.0 ft2
0.23
0.3
0
_ 25
E
Garage
Frame - Wood
Dining
11 9
9 4
84.0 ft2
0.23
0.3
0
DOORS
#
Omt
Door Type
Space
Storms
U Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated
Family
None
.39
5
11
8
47.3 ft2
2
S
Insulated
Foyer
None
.39
5
11
8
47.3 ft2
3
S
Insulated
Hall 1
None
.39
2
8
8
21.3 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
N 1
Vinyl
Low-E Single
Yes
0.32 0.22
Y
30.8 ft2
1 ft 7 in
1 ft 4 in
None
None
2
E 2
Vinyl
Low-E Single
Yes
0.32 0.22
Y
40.0 ft2
3 ft 0 in
1 ft 4 in
None
None
3
W 3
Vinyl
Low-E Single
Yes
0.32 0.22
Y
10.0 ft2
1 ft 7 in
1 ft 4 in
None
None
4
W 6
Vinyl
Low-E Single
Yes
0.29 0.23
Y
8.0 ft2
1 ft 7 in
1 ft 4 in
None
None
5
S 8
Vinyl
Low-E Single
Yes
0.32 0.19
Y
15.0 ft2
1 ft 7 in
1 ft 4 in
None
None
6
N 10
Vinyl
Low-E Single
Yes
0.32 0.22
Y
24.0 ft2
10 ft 0 in
1 ft 4 in
None
None
7
N 10
Vinyl
Low-E Single
Yes
0.32 0.22
Y
24.7 ft2
10 ft 0 in
1 ft 4 in
None
None
8
S 12
Vinyl
Low-E Single
Yes
0.32 0.19
Y
30.0 ft2
5 ft 0 in
1 ft 4 in
None
None
9
S 14
Vinyl
Low-E Single
Yes
0.32 0.19
Y
14.6 ft2
5 ft 0 in
1 ft 4 in
None
None
10
S 14
Vinyl
Low-E Single
Yes
0.32 0.19
Y
15.0 ft2
5 ft 0 in
1 ft 4 in
None
None
11
N 16
Vinyl
Low-E Single
Yes
0.32 0.22
Y
16.0 ft2
10 ft 0 in
1 ft 4 in
None
None
12
N 17
Vinyl
Low-E Single
Yes
0.32 0.22
Y
30.0 ft2
1 ft 7 in
1 ft 4 in
None
None
13
E 18
Vinyl
Low-E Single
Yes
0.32 0.22
Y
15.0 ft2
1 ft 7 in
1 ft 4 in
None
None
14
E 21
Vinyl
Low-E Single
Yes
0.32 0.22
Y
8.0 ft2
1 ft 7 in
1 ft 4 in
None
None
15
E 22
Vinyl
Low-E Single
Yes
0.32 0.22
Y
15.0 ft2
1 ft 7 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
696 ft2
696 ft2
26 ft
9.4 ft
11
6/28/2021 10:35 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000298
1894.9 103.96 195.17 .0963
5
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
None
COPA 27 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 16 36.2 kBtu/hr cfm
0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
— Supply —
\/ # Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1 Attic 6 85 ftz
Attic
20 ftz Default Leakage Attic (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb Mar
HeatinJan Feb Mar
Vent in Jan Feb Mar
Ceiling Fans:
Apr May Jun Jul Auge
f Apr I I May rl Jun n Jul ri Augn Sep f
[X] Apr May Jun Jul Aug Se [X]
Oct Nov
Oct Nov
Oct Nov
Dec
Dec
Dec
6/28/2021 10:35 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Master Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M Toilet
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 lbs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
Family
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Office
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining
Default(8 lbs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Toilet
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(8lbs/s .ft.
ft2
ft
0.3
Hall 1
6/28/2021 10:35 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7