Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Melville Residence Project Address: 7827 Saba] Lake Drive, Port St, Lucie, Florida 34986 Permit #: Occupancy Type: R-3 Construction Type: III B unprotetced INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) Seventh 1. DESIGN CODE: Florida 2020 Code -Sixth -Edition with 20 20 Supplements using ASCE fir} 7-16 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: I X II III IV Exposure Category: B X C D 4. Design Wind Velocity . 160 (ult) mph 124 ASD LRFD End Zone Width: 4 ft 5. Mean Roof Height <20 ft Roof Pitch: 6 :12 Parapet: n/a ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +22/-51 Zone 2: +22/-81 Zone 3: +22/-104 Zone 4: +36/-39 Zone 5: +36/-48 Garage: +30/-37 7. Design Loads: Floor: n/a PSF Roof/Dead: 30 PSF Roof/Live: 20 Balcony: n/a PSF Dock: n/a PSF Deck: n/a PSF Stairs: n/a PSF Fence: n/a PSF Railings: n/a PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2,500 PSF Soil Test Reports Submitted? x Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie •ern;ee, County. I also certify ta�tl..st�rycty� 4lements depicted on these plans provide adequate resistance to the design forces specified•F ° d Michael Lue •0'O� print Name Cert # & Co. Cert Auth. ® ° a L j n FL Certification#: PE 47520/ SI# 1061 - COA # 8662 Signature, D °d eal- i - ,; M. L Engineering, Inc., 203tnMfe).Vel7Beach, FL 32960 ^ rL � Company Name & Ad eeeee Revised 12/07/20 8 poea"•��®